UserName
High Quality & Purity Lab Chemicals
Advance your workflows for oligo synthesis, chromatography, water determination, and trace analysis with solvents, reagents, and standards from the industry’s recognized brands.
Catalog Number 6002652
Catalog Number 6001144
CAS: 100-66-3 Molecular Formula: C7H8O Molecular Weight (g/mol): 108.14 MDL Number: MFCD00007941 InChI Key: RDOXTESZEPMUJZ-UHFFFAOYSA-N Synonym: Methoxybenzene,Methyl phenyl ether PubChem CID: 7519 ChEBI: CHEBI:16579 IUPAC Name: anisole SMILES: COC1=CC=CC=C1
PubChem CID | 7519 |
---|---|
CAS | 100-66-3 |
Molecular Weight (g/mol) | 108.14 |
ChEBI | CHEBI:16579 |
MDL Number | MFCD00007941 |
SMILES | COC1=CC=CC=C1 |
Synonym | Methoxybenzene,Methyl phenyl ether |
IUPAC Name | anisole |
InChI Key | RDOXTESZEPMUJZ-UHFFFAOYSA-N |
Molecular Formula | C7H8O |
CAS: 95-47-6 Molecular Formula: C8H10 Molecular Weight (g/mol): 106.17 MDL Number: MFCD00008519 InChI Key: CTQNGGLPUBDAKN-UHFFFAOYSA-N IUPAC Name: 1,2-xylene SMILES: CC1=CC=CC=C1C
CAS | 95-47-6 |
---|---|
Molecular Weight (g/mol) | 106.17 |
MDL Number | MFCD00008519 |
SMILES | CC1=CC=CC=C1C |
IUPAC Name | 1,2-xylene |
InChI Key | CTQNGGLPUBDAKN-UHFFFAOYSA-N |
Molecular Formula | C8H10 |
Anolyte for coulometric Karl Fischer titration in oils (chloroform-methanol-xylene-based), preferred for cells with diaphragm
UN Number | UN1992 |
---|
CAS: 108-32-7 Molecular Formula: C8H10 Molecular Weight (g/mol): 106.17 MDL Number: MFCD00008519 InChI Key: CTQNGGLPUBDAKN-UHFFFAOYSA-N Synonym: 1,2-Propanediol cyclic carbonate,4-Methyl-1,3-dioxolan-2-one PubChem CID: 962 ChEBI: CHEBI:15377 IUPAC Name: 1,2-xylene SMILES: CC1=CC=CC=C1C
PubChem CID | 962 |
---|---|
CAS | 108-32-7 |
Molecular Weight (g/mol) | 106.17 |
ChEBI | CHEBI:15377 |
MDL Number | MFCD00008519 |
SMILES | CC1=CC=CC=C1C |
Synonym | 1,2-Propanediol cyclic carbonate,4-Methyl-1,3-dioxolan-2-one |
IUPAC Name | 1,2-xylene |
InChI Key | CTQNGGLPUBDAKN-UHFFFAOYSA-N |
Molecular Formula | C8H10 |
UN Number | UN1992 |
---|
CAS | 68007-08-9 |
---|---|
UN Number | UN1230 |
Boiling Point | 64°C |
---|---|
CAS Min % | ≥5.0000% |
UN Number | UN1230 |
Chemical Name or Material | HYDRANALâ„¢ - Coulomat AG-Oven |
Grade | Karl Fischer |
Density | 0.980 g/cm3 |
Name Note | Reagent for coulometric KF titration with oven (anolyte solution), for cells with and without diaphragm |
CAS | 68007-08-9 |
Packaging | Glass Bottle |
Flash Point | 13°C |
DOT Information | Transport Hazard Class: 3; Packing Group:3: II; Proper Shipping Name: Methanol Solution |
Recommended Storage | Room Temp |
Shelf Life | 1800 days from date of manufacture |
CAS Max % | <10.0000% |
Medium for volumetric one- and two-component Karl Fischer titration in oils (chloroform-methanol-xylene-based)
CAS | 7446-09-5 |
---|---|
Health Hazard 2 | P201-P210-P280-P308 + P311-P370 + P378-P403 + P235 |
Flash Point | 6°C (42.8°F) |
UN Number | UN1992 |
Chemical Name or Material | HYDRANALâ„¢-Solver (Crude) oil |
Density | 1.01g/mL |
CAS: 64-18-6 Molecular Formula: CH2O2 Molecular Weight (g/mol): 46.025 MDL Number: MFCD00003297 InChI Key: BDAGIHXWWSANSR-UHFFFAOYSA-N Synonym: methanoic acid,formylic acid,aminic acid,bilorin,hydrogen carboxylic acid,formisoton,myrmicyl,formira,acide formique,collo-bueglatt PubChem CID: 284 ChEBI: CHEBI:30751 IUPAC Name: formic acid SMILES: C(=O)O
PubChem CID | 284 |
---|---|
CAS | 64-18-6 |
Molecular Weight (g/mol) | 46.025 |
ChEBI | CHEBI:30751 |
MDL Number | MFCD00003297 |
SMILES | C(=O)O |
Synonym | methanoic acid,formylic acid,aminic acid,bilorin,hydrogen carboxylic acid,formisoton,myrmicyl,formira,acide formique,collo-bueglatt |
IUPAC Name | formic acid |
InChI Key | BDAGIHXWWSANSR-UHFFFAOYSA-N |
Molecular Formula | CH2O2 |
UN Number | UN1230 |
---|
CAS | 7446-09-5 |
---|---|
Health Hazard 2 | P210-P280-P304 + P340 + P312-P305 + P351 + P338 + P310-P370 + P378-P403 + P235 |
UN Number | UN1230 |
Anolyte for coulometric Karl Fischer titration (ethanol-based), for cells with and without diaphragm
CAS | 67-56-1 |
---|---|
Health Hazard 2 | P201-P210-P280-P308 + P313-P370 + P378-P403 + P235 |
CAS: 1336-21-6 Molecular Formula: H5NO Molecular Weight (g/mol): 35.05 MDL Number: MFCD00066650 InChI Key: VHUUQVKOLVNVRT-UHFFFAOYSA-N Synonym: ammonium hydroxide,ammonia water,ammonia aqueous,aquammonia,aqua ammonia,ammonia, aqua,household ammonia,ammonium hydroxide solution,ammonia, monohydrate,ammonium hydroxide nh4 oh PubChem CID: 14923 ChEBI: CHEBI:18219 IUPAC Name: azanium;hydroxide SMILES: N.O
PubChem CID | 14923 |
---|---|
CAS | 1336-21-6 |
Molecular Weight (g/mol) | 35.05 |
ChEBI | CHEBI:18219 |
MDL Number | MFCD00066650 |
SMILES | N.O |
Synonym | ammonium hydroxide,ammonia water,ammonia aqueous,aquammonia,aqua ammonia,ammonia, aqua,household ammonia,ammonium hydroxide solution,ammonia, monohydrate,ammonium hydroxide nh4 oh |
IUPAC Name | azanium;hydroxide |
InChI Key | VHUUQVKOLVNVRT-UHFFFAOYSA-N |
Molecular Formula | H5NO |
Drying agent for air and gases for Karl Fischer titration
Improve your DNA/RNA yield at each step of the oligonucleotide synthesis cycle with the Honeywell Burdick & Jacksonâ„¢ BioSynâ„¢ line of products that includes a wide range of high-purity solvents and reagents.
Honeywell Research Chemicals Oligo Synthesis Brochure (PDF, 421KB)
Have greater confidence in your demanding liquid or gas chromatography workflows with high-purity Honeywell solvents, blends, eluents, and additives. They help deliver improved chromatography performance and accurate results.
Download the Honeywell Research Chemicals Chromatography Brochure (PDF, 1.3MB)
Ensure your analysis is in the safest hands with expertly manufactured solvents with the purity and consistency required for chromatography (HPLC, LC-MS, UHPLC-MS, GC, and headspace). Join analytical laboratories around the globe by trusting Honeywell Burdick & Jacksonâ„¢ and Honeywell Chromasolvâ„¢ solvents to provide accurate results, because accuracy is non-negotiable.
Eliminate the effort and inaccuracies of manual blending and work more safely and efficiently with Honeywell LabReady™ solvent blends for HPLC and LC-MS workflows. They’re made with closed-loop blending technology that eliminates variation.
Optimize chromatography performance with Honeywell Flukaâ„¢ high-quality buffers/salts and eluents. Tested for LC-MS or UHPLC-MS suitability, they enable analytical labs to adjust eluent pH to improve the robustness of the method regarding retention times and selectivity. They also help improve the analyte signal or suppress unwanted signals.
Karl Fischer titration (KFT) is the preferred technique for water determination due to its superior accuracy, increased speed and selectivity, and practical advantages over other methods. The Honeywell Hydranalâ„¢ product portfolio includes easy-to-use, pyridine-free reagents and reliable standards for accurate Karl Fischer titration.
Hydranal reagents provide the following advantages:
Hydranal NextGen products offer CMR free (imidazole free) formulations for safer volumetric and coulometric KFT and RFID technology for seamless data transfer from Hydranal reagents to the titrator.
Download the Honeywell Research Chemicals Karl Fischer Titration Brochure (PDF, 1MB)
Choose from a broad range of Hydranal one-component or two-component reagents developed for water determination by volumetric Karl Fischer titration, offering high accuracy and the greatest flexibility for media selection.
Shop Hydranal Regents for Volumetric Titration
Find reagents for highly accurate measurements of trace amounts of water in all types of samples with coulometric Karl Fischer titration.
Browse reliable standards (RM) and Certified Reference Materials (CRMs) with verified water content for titer determination, monitoring precision and accuracy, or validation and inspection of Karl Fischer titrators.
Explore products for ensuring accurate water determination when applying Karl Fischer titration to different sample varieties, including solubilizers, buffers, and drying agents.
Enable the detection of impurities in the ppb and ppt detection range with Honeywell TraceSelectâ„¢ and TraceSelectâ„¢ Ultra reagents and solvents for sample preparation and analysis using ICP-OES, ICP-MS, AAS, or GF-AAS.
To ensure high quality and purity for improved reliability and accuracy, the reagents and solvents are:
Download the Honeywell Research Chemicals Trace Analysis Brochure (PDF, 737KB)
Find high-purity reagents for sample preparation for trace analysis and elemental impurity detection, including ultra-pure acids, bases, and salts for smelting and wet digestion for analysis at ppb and ppt levels.
Browse Honeywell TraceSelect solvents for speciation analysis by LC-ICP-MS that undergo rigorous purification procedures followed by UV spectroscopy, IC, and ICP-MS testing to assure high chemical purity and high UV transmittance.
Honeywell Research Chemicals and the Fisher Scientific channel are partners in providing you with high-quality chemicals at great prices. You can count on the extensive Fisher Scientific distribution network to supply you with the solvents and analytical reagents you need, whenever you need them.
The Honeywell Research Chemical business is based upon a rich history of chemical knowledge and manufacturing.