Cytiva HiTrap™ Benzamidine FF (high sub) Columns
Remove or purify serine proteases such as thrombin. Cytiva Life Sciences™ HiTrap™ Benzamidine FF (high sub) Columns are prepacked with Benzamidine Sepharose 4 Fast Flow (high sub).
| Particle Size | 90 μm |
|---|---|
| Ligand Type | >12μM p-aminobenzamidine/mL medium |
| Height (Metric) | 2.5cm |
| Content And Storage | 2° to 8°C |
| pH Range | 2 to 8 |
| Product Type | Benzamidine FF Column |
| For Use With (Equipment) | Syringe, peristaltic pump or liquid chromato graphy system such as AKTA™ design or FPLC system |
| Sample Type | Serine Proteases such as Thrombin |
| Material | Polypropylene |
| For Use With (Application) | Removal or purification of Serine Proteases such as Thrombin |
| Support Type | 4% Highly Cross-linked Agarose |
| Max. Pressure | 42psi |
| Height (English) | 0.98 in. |
Cytiva HiTrap™ Streptavidin HP Column
Use for fast and easy preparative purifications either alone or connected in series. HiTrap™ Streptavidin HP Column are convenient and reliable prepacked columns.
| Particle Size | 100 to 300 μm in wet form, 50 to 150 μm in dry form |
|---|---|
| Height (Metric) | 10cm |
| Bed Volume | 9 to 11mg/g |
| Format | Solid Bead |
| pH Range | 2 to 10 |
| Product Type | Sephadex G50 Media |
| Sample Type | DNA |
| Diameter (Metric) Inner | 5cm |
| Support Type | Cross-linked Dextran |
| Height (English) | 3.93 in. |
Cytiva Sephadex™ G10 Media
Gel filtration medium for desalting and buffer exchange of peptides and small biomolecules
| Height (Metric) | 30cm |
|---|---|
| Content And Storage | 4 to 30°C |
| Bed Volume | 2 to 3mL/g in Distilled Water |
| pH Range | 2 to 13 |
| Diameter (Metric) Inner | 2.6cm |
| For Use With (Application) | Desalting and Buffer exchange of Peptides and small biomolecules >700 M.W. |
| Max. Pressure | 24-49 cm/h, pressure drop cm H2O/bed height = 2, bed height 30 cm, 2.6 cm i.d |
| Particle Size | 55 to 165 μm in wet form, 40 to 120 μm in dry form |
| Flow Rate | < Darcy´s Law |
| Format | Solid Bead |
| Product Type | Sephadex G10 Media |
| Sample Type | Peptides, Small Biomolecules |
| Support Type | Cross-linked Dextran |
| Height (English) | 11.81 in. |
| Height (Metric) | 5 to 15cm |
|---|---|
| Content And Storage | 4° to 30°C |
| Format | Solid Spherical Bead |
| Product Type | Sephadex Ion Exchange Media |
| For Use With (Equipment) | Column or Batch Techniques |
| For Use With (Application) | Separating and purifying Proteins, Polypeptides, Nucleic Acids and other charged biomolecules by using column or batch techniques |
| Support Type | Cross-linked Dextran |
| Height (English) | 2 to 5.9 in. |
Cytiva Sephadex G-50 Medium, 500g
Suitable for large scale separation. Cytiva Sephadex G-50 Medium, 500g is a well-established gel filtration medium for desalting and buffer exchange of biomolecules >30 000 molecular weight.
Cytiva Superdex 30 Increase Tricon™ 10/300 GL Prepacked SEC Column
Designed for high resolution in small-scale preparative purification and analysis for sample volumes up to 500μL
Cytiva Gel Filtration Calibration Kits
Calibrate gel filtration columns simply, reliably. Cytiva Life Sciences™ Gel Filtration Calibration Kits contain a well-defined series of protein standards.
| Content And Storage | 2° to 8°C |
|---|---|
| Product Type | Calibration Kit |
| For Use With (Equipment) | High-resolution media and prepacked column |
| Quantity | Each |
| For Use With (Application) | Calibration of high-resolution gel filtration media and column such as Superdex™, Superose and Sephacryl |
Cytiva Sephacryl™ S-500 High Resolution Media
Hydrophilic, rigid allyl dextran/bisacrylamide matrix for fast and reproducible purification of proteins, polysaccharides and other macromolecules
| Height (Metric) | 15cm |
|---|---|
| Content And Storage | 4° to 30°C |
| Bed Volume | 19 to 230L |
| pH Range | 3 to 11 |
| Diameter (Metric) Inner | 40 to 140cm |
| For Use With (Application) | Allow fast and reproducible purification of proteins, polysaccharides and other macromolecules by gel filtration at laborato ry and industrial scale |
| Max. Pressure | 100kPa |
| Particle Size | 25 to 75 μm |
| Flow Rate | >125 cm/hr. |
| Format | Solid Spherical Bead |
| Product Type | Sephacryl HR Media |
| Sample Type | Polysaccharides, macromolecules and small plasmids |
| Support Type | Allyl Dextran and N, N'-methylenebisacrylamide |
| Height (English) | 5.9 in. |
Cytiva Superdex™ 200 Increase 3.2/300 Prepacked Precision Column
Used for micro-scale (μg) preparative purification and for characterization and analysis of small volumes (4 to 50μL) of proteins. Cytiva Lifescience™ Superdex™ 200 Increase 3.2/300 Prepacked Precision Column desigened for size exclusion chromatography.
Cytiva HiLoad™ 16/600 Superose™ 6 Prep Grade Preparative SEC Column
A prepacked SEC column for high-resolution purification of large biomolecules and protein complexes with sample volumes up to 5 mL
Cytiva HiTrap™ Blue HP Columns
For purifying albumin, enzymes including NAD+ and NADP+, coagulation factors, interferons and related proteins
| Particle Size | 34 μm |
|---|---|
| Height (Metric) | 2.5cm |
| Content And Storage | 4° to 30°C |
| pH Range | 4 to 12 |
| Product Type | Blue HP Columns |
| For Use With (Equipment) | Syringe, peristaltic pump or liquid chromato graphy system such as AKTA™ design or FPLC system |
| Sample Type | Albumin, Interferon, Nucleotide-dependent Enzymes, a2-macroglobulin, Coagulation Factors and Related Proteins |
| Material | Polypropylene |
| For Use With (Application) | Purifying wide range of biomolecules, including albumin, interferon, a broad range of nucleotide-dependent Enzymes, alpha2-macroglobulin, coagulation facto rs and related Proteins |
| Support Type | 6% Highly Cross-linked Agarose |
| Max. Pressure | 42psi |
| Height (English) | 0.98 in. |
Cytiva HiTrap™ Heparin HP Columns
Purify DNA-binding proteins, coagulation factors, lipoproteins and protein synthesis factors. Cytiva Life Sciences™ HiTrap™ Heparin HP Columns are prepacked with Heparin Sepharose™ High Performance for high-resolution purification.
| Particle Size | 34 μm |
|---|---|
| Ligand Type | 10mg Heparin/mL medium |
| Height (Metric) | 2.5cm |
| Content And Storage | 4° to 30°C |
| pH Range | 5 to 10 |
| Product Type | Heparin HP Column |
| For Use With (Equipment) | Syringe, peristaltic pump or liquid chromato graphy system such as AKTA™ design or FPLC system |
| Material | Polypropylene |
| For Use With (Application) | Purification of Antithrombin III, coagulation facto rs and other Plasma Proteins |
| Support Type | 6% Highly Cross-linked Agarose |
| Max. Pressure | 42psi |
| Height (English) | 0.98 in. |
Cytiva Sephadex™ G-50 and G-100 DNA Grade Agarose Gels
Used for purification of DNA from small molecules. Cytiva illustra™ Sephadex™ G-50 and G-100 DNA Grade Agarose Gels purify DNA by gel filtration.
| Content And Storage | 4° to 30°C |
|---|---|
| Format | Beaded Gel |
| pH Range | 2 to 10 |
| Product Type | G-50 and G-100 DNA Grade Agarose Gels |
| For Use With (Equipment) | Auto Seq G-50 column, ProbeQuant G-50 micro column, MicroSpin G-50 column and NICK column |
| Sample Type | DNA |
| Support Type | Cross-linked Dextran with Epichlorohydrin |