MilliporeSigma™ Supelco™ Discovery™ BIO Wide Pore C5 HPLC Column, 10 μm Particle Size
Discovery™ BIO Wide Pore C5 was designed for the efficient and reliable separation of proteins and peptides, especially hydrophobic peptides, by RP- HPLC.
| Phase | Reversed Phase |
|---|---|
| Matrice | C5 (pentyl) Phase/Silica Particle Platform |
| “End-capped” | Yes |
| Gamme de produits | Discovery |
| Surface spécifique | 100 m2/g |
| Granulométrie | 10 μm |
| Technique | Wide Pore HPLC |
| Porosité | 300 Å |
| Phase stationnaire | C5 (pentyl) |
Thermo Scientific™ Syncronis™ C18 Columns
Use for hydrophobic interaction reversed-phase separations.
| Phase | Reversed Phase |
|---|---|
| Température | 60°C |
| Taux de carbone | 16% |
| “End-capped” | Yes |
| Type d’USP | L1 |
| pH | 2 to 9 |
| Surface spécifique | 320 m²/g |
| Porosité | 100 Å |
| Type de colonne | Reversed Phase |
| Phase stationnaire | C18 |
TSKgel™ Butyl-NPR HPLC Column, 2.5 μm Particle Size, Sold by MilliporeSigma™ Supelco™
TSKgel™ Butyl-NPR columns are not as hydrophobic, i.e., less retentive, than Phenyl-5PW and Ether-5PW HIC columns. They are the best choice for high speed separations and provide excellent recovery even for more hydrophobic proteins.
MilliporeSigma Ascentis™ Express PCS-C18 HPLC Column
Ascentis™ Express PCS-C18 columns are specifically engineered to provide efficient separation of basic, acidic, or neutral compounds under low ionic strength (formic acid) mobile phase conditions.
| Type | HPLC Column |
|---|---|
| Phase | Positively Charged Surface (PCS) |
| Matériau | Stainless Steel |
| Granulométrie | 2.7 μm |
| Technique | HPLC |
| Porosité | 90 Å |
MilliporeSigma™ Supelco™ Discovery™ C18 HPLC Column, 5 μm Particle Size
Use Discovery™ C18 for any method that specifies a C18. The exceptional peak shape, reproducibility, and stability make it the column of choice for all C18 methods from demanding to routine.
| Phase | Reversed Phase |
|---|---|
| Matrice | C18 (Octadecyl) Phase/Silica Gel, High Purity, Spherical Particle Platform |
| Matériau | Stainless Steel |
| “End-capped” | Yes |
| Gamme de produits | Discovery |
| pH | 2 to 8 |
| Surface spécifique | 200 m2/g |
| Granulométrie | 5 μm |
| Porosité | 180 Å |
| Phase stationnaire | C18 (Octadecyl) |
Thermo Scientific™ Acclaim™ C30 HPLC Columns
Greener Choice
Offers one or more environmental benefits itemized in the U.S. FTC Green Guides.
Learn More
Offers one or more environmental benefits itemized in the U.S. FTC Green Guides.
Learn More
Use for superior separation of hydrophobic structural isomers.
| Phase | Reversed Phase |
|---|---|
| Température | 60°C |
| Taux de carbone | 13% |
| Gamme de produits | Acclaim |
| pH | 2 to 8 |
| Surface spécifique | 200 m²/g |
| Porosité | 200 Å |
| Type de colonne | Reversed Phase |
| Phase stationnaire | C30 |
MilliporeSigma™ Supelco™ Discovery™ BIO Wide Pore C18 HPLC Column, 10 μm Particle Size
The Discovery™ BIO Wide Pore C18 column has the ability to analyze peptides without TFA in the mobile phase, thereby increasing the LC-MS signal.
| Phase | Reversed Phase |
|---|---|
| Matrice | C18 (octadecyl) Phase/silica particle platform |
| “End-capped” | Yes |
| Gamme de produits | Discovery |
| Surface spécifique | 100 m2/g |
| Granulométrie | 10 μm |
| Technique | Wide Pore HPLC |
| Porosité | 300 Å |
| Phase stationnaire | C18 (octadecyl) |
Restek™ Pinnacle™ DB C8 Specialty/Application Specific HPLC Column, 5 μm
Base-deactivated spherical silica optimized for UHPLC stability.
| À utiliser avec | Analysis of Basic Compounds or Bases Mixed with Acids/Neutrals |
|---|---|
| Épaisseur du film | 5 μm |
| Phase | Reversed Phase |
| Forme des particules | Spherical |
| Matériau | Stainless Steel |
| Type d’USP | L7 |
| Porosité | 140 Å |
| Matériau de remplissage | Silica |
| Phase stationnaire | C8 |
| Température | 80°C |
| Type de ligand | Monomeric C8 |
| Taux de carbone | 6% |
| “End-capped” | Yes |
| pH | 2.5 to 10 |
| Quantité | 5 g |
| Granulométrie | 5 μm |
| Technique | UHPLC |
| Pression max. | 4000 psi (275 bar) |
| Type de colonne | Specialty/Application Specific |
Restek™ Viva™ HPLC Columns with C18 Column Packing, 5μm Particle Size
Wide bore silica columns excellent for general-purpose applications and separating peptides or proteins
| À utiliser avec | Analyzing Large Molecules and Biomolecules |
|---|---|
| Épaisseur du film | 5 μm |
| Phase | Reversed Phase |
| Forme des particules | Spherical |
| Type d’USP | L1 |
| Porosité | 300 Å |
| Matériau de remplissage | Silica |
| Phase stationnaire | C18 |
| Type | Column |
| Température | 80°C |
| Taux de carbone | 9% |
| “End-capped” | Yes |
| pH | 2.5 to 10 |
| Granulométrie | 5 μm |
| Type de colonne | Reversed Phase |
Hamilton™ PRP-1 Reversed Phase HPLC Columns, 10um Particle Size: PEEK
Stable alternative to C8 or C18 Columns
| Débit | 1.0 mL/min |
|---|---|
| Phase | Reversed Phase |
| Matériau | PEEK |
| Type d’USP | L21 |
| Porosité | 100 Å |
| Diamètre (métrique) | 4.6 mm |
| Matériau de remplissage | PSDVB (Polystyrene Divinylbenzene) |
| Phase stationnaire | PRP-1 |
| Compatibilité de phase mobile | pH 1 to 13, 0 to 100% aqueous, organic modifier |
| Type | Column |
| Température | 5°C to 85°C |
| pH | 1 to 13 |
| Granulométrie | 10 μm |
| Pression max. | 5000 psi (345 bar) |
| Type de colonne | Reversed Phase |
| Format de colonne | Analytical Column |
Hamilton™ PRP-1 Reversed Phase HPLC Columns, 10um Particle Size: Stainless Steel
Stable alternative to C8 or C18 Columns
| Compatibilité de phase mobile | pH 1 to 13, 0 to 100% aqueous, organic modifier |
|---|---|
| Type | Column |
| Phase | Reversed Phase |
| Température | 5°C to 85°C |
| Matériau | Stainless Steel |
| Type d’USP | L21 |
| pH | 1 to 13 |
| Porosité | 100 Å |
| Pression max. | 5000 psi (345 bar) |
| Type de colonne | Reversed Phase |
| Matériau de remplissage | PSDVB (Polystyrene Divinylbenzene) |
| Phase stationnaire | PRP-1 |
| Format de colonne | Analytical Column |
Hamilton™ PRP™-3 Reversed Phase HPLC Columns
PRP-3 polymeric 300 Å columns for gradient separations of peptides and proteins
| Phase | Reversed Phase |
|---|---|
| Température | 5°C to 85°C |
| Type d’USP | L21 |
| pH | 1 to 13 |
| Granulométrie | 10 μm |
| Porosité | 300 Å |
| Pression max. | 5000 psi (345 bar) |
| Type de colonne | Reversed Phase |
| Matériau de remplissage | PSDVB (Polystyrene Divinylbenzene) |
| Phase stationnaire | PRP-3 |
| Type | Cartridge |
|---|---|
| Phase | Reversed Phase |
| Matériau | Stainless Steel |
| “End-capped” | Yes |
| Type d’USP | L1 |
| Porosité | 100 Å |
| Type de colonne | Reversed Phase |
| Matériau de remplissage | Silica |
| Phase stationnaire | C18 |
Thermo Scientific™ BetaSil™ C18 HPLC Columns, 5μm Particle Size
High surface area with high bonded phase coverage
| Phase | Reversed Phase |
|---|---|
| Taux de carbone | 20% |
| “End-capped” | Yes |
| Type d’USP | L1 |
| Surface spécifique | 310 m²/g |
| Granulométrie | 5 μm |
| Porosité | 100 Å |
| Type de colonne | Reversed Phase |
| Phase stationnaire | C18 |
Thermo Scientific™ BetaSil™ C18 HPLC Columns, 3μm Particle Size
High surface area with high bonded phase coverage
| Phase | Reversed Phase |
|---|---|
| Taux de carbone | 20% |
| Type d’USP | L1 |
| Granulométrie | 3 μm |
| Porosité | 100 Å |
| Type de colonne | Reversed Phase |
| Phase stationnaire | C18 |