Low to Medium Pressure LC Columns
- (19)
- (10)
- (7)
- (1)
- (5)
- (1)
- (1)
- (14)
- (1)
- (15)
- (32)
- (1)
- (12)
- (31)
- (3)
- (36)
- (44)
- (2)
- (5)
- (2)
- (9)
- (1)
- (41)
- (9)
- (5)
- (20)
- (1)
- (9)
- (6)
- (1)
- (4)
- (1)
- (3)
- (6)
- (23)
- (9)
- (2)
- (29)
- (24)
- (7)
- (5)
- (6)
- (35)
- (17)
- (27)
- (32)
- (4)
- (3)
- (5)
- (28)
- (3)
- (1)
- (4)
- (1)
- (6)
- (2)
- (2)
- (20)
- (12)
- (8)
- (2)
- (6)
- (3)
- (8)
- (3)
- (131)
- (3)
- (6)
- (1)
- (1)
- (8)
- (55)
- (2)
- (1)
- (24)
- (2)
- (4)
- (1)
- (18)
- (5)
- (1)
- (2)
- (5)
- (3)
- (2)
- (14)
- (3)
- (2)
- (70)
- (3)
- (29)
- (18)
- (24)
- (8)
- (6)
- (2)
- (5)
Filtered Search Results
DWK Life Sciences Kimble™ Kontes™ Chromatography Column with Joint
General purpose gravity chromatography columns
DWK Life Sciences Kimble™ Kontes™ Disposaflex™ Glass Columns
Multipurpose glass column with polypropylene reservoir
| Includes | 9mL Polypropylene reservoir, lower column fitting with luer outlet, Polyethylene bed supports |
|---|---|
| Type | Chromatography Column Set |
| Length (Metric) | 150 mm |
| Support Material | Polyethylene |
| Diameter (Metric) Inner | 8 mm |
| Material | Glass |
| Column Capacity | 6 mL |
MilliporeSigma™ Supelco™ Multi-Layer Silica Gel Dioxin Column
For use with Dioxin Sample Preparation Kit
DWK Life Sciences Kimble™ Kontes™ Cadmium Reduction Chromatography Column Only
Replacement Cadmium Reduction Column with PTFE BEVEL-SEAL for use with Kimble™l 419000-8505.
MilliporeSigma™ Supelco™ Specialty Glass Column
Fill columns with appropriate adsorbents when cleaning or drying environmental samples for pesticide or priority pollutant analyses
| Type | Specialty Column |
|---|---|
| Description | Drying Column with Reservoir |
| Length (Metric) | 200 mm |
| Quantity | 1 Ea. |
| Material | Glass |
| For Use With (Application) | US EPA Protocol |
Thermo Scientific™ CaptureSelect™ LambdaXP RoboColumn™ Pre-packed Columns
CaptureSelect RoboColumns are small chromatography columns used for fully automated and parallel chromatographic separations on robotic liquid handling workstations.
| Product Line | CaptureSelect |
|---|
DWK Life Sciences Kimble™ Kontes™ FlexColumn™ Economy Columns
Ideal for use with FPLC™ systems, peristaltic pumps, or gravity flow to 15psi
| Pore Size | 20 μm |
|---|---|
| Type | Economy Chromatography Column |
| Sterilization Method | 2N NaOH or 100% Ethanol |
| Temperature (Metric) Range | 0 to 50°C |
| Endcapped | Yes |
| Support Material | HDPE |
| Diameter (Metric) Inner | 15 mm |
| Material | Borosilicate Glass Type I Class A |
| For Use With (Application) | Ion exchange, affinity, gel filtration and hydrophobic interaction media |
| Cross Sectional Area | 1.77cm3 |
| Connector Types | Male luer lock |
| Max. Pressure | 14.5 psi |
Thermo Scientific™ POROS™ GoPure™ Caprylate Pre-packed Column, 0.5 x 5 cm, 1 mL
Greener Choice
Offers one or more environmental benefits itemized in the U.S. FTC Green Guides.
Learn More
Offers one or more environmental benefits itemized in the U.S. FTC Green Guides.
Learn More
Thermo Scientific™ POROS™ GoPure™ pre-packed columns are intended for the screening of POROS chromatography resins or for small scale purification.
Thermo Scientific™ POROS™ GoPure™ Caprylate Pre-packed Column, 0.8 x 10 cm, 5 mL
Greener Choice
Offers one or more environmental benefits itemized in the U.S. FTC Green Guides.
Learn More
Offers one or more environmental benefits itemized in the U.S. FTC Green Guides.
Learn More
Thermo Scientific™ POROS™ GoPure™ pre-packed columns are intended for the screening of POROS chromatography resins or for small scale purification.
Thermo Scientific™ POROS™ Caprylate RoboColumn™ Pre-packed columns
Greener Choice
Offers one or more environmental benefits itemized in the U.S. FTC Green Guides.
Learn More
Offers one or more environmental benefits itemized in the U.S. FTC Green Guides.
Learn More
These Thermo Scientific™ POROS™ Caprylate RoboColumn™ are pre-packed with POROS Caprylate Mixed-Mode Chromatography Resin to remove moderate to high levels of aggregates during downstream processing of therapeutic antibodies in flow-through mode.
| Stationary Phase | Caprylic Acid |
|---|---|
| Type | Pre-packed Column |
| Target | Monoclonal Antibodies |
| Content And Storage | Store at 2–30°C. |
| Product Line | POROS |
Thermo Scientific™ CaptureSelect™ KappaXP RoboColumn™ Pre-packed columns
Thermo Scientific™ CaptureSelect™ RoboColumn™ are small chromatography columns used for fully automated and parallel chromatographic separations on robotic liquid handling workstations.
Thermo Scientific™ CaptureSelect™ C-tagXL RoboColumn™ Pre-packed columns
Thermo Scientific™ CaptureSelect™ RoboColumn™ are small chromatography columns used for fully automated and parallel chromatographic separations on robotic liquid handling workstations.
Thermo Scientific™ CaptureSelect™ AAT-XL RoboColumn™ Pre-packed columns
Thermo Scientific™ CaptureSelect™ RoboColumn™ are small chromatography columns used for fully automated and parallel chromatographic separations on robotic liquid handling workstations.
Thermo Scientific™ CaptureSelect™ CH1-XL RoboColumn™ Pre-packed Column
Thermo Scientific™ CaptureSelect™ RoboColumn™ small chromatography columns are used for fully automated and parallel chromatographic separations on robotic liquid handling workstations.
| Shipping Condition | Room temperature, or on wet ice |
|---|---|
| Ligand Type | CH1-XL affinity ligand |
| Flow Rate | 16 to 150 cm/hr. |
| Stationary Phase | CH1-XL affinity ligand on agarose bead |
| Type | RoboColumn |
| Content And Storage | Store in refrigerator (2°C to 8°C) |
| Matrix | Agarose-based, Epoxide-activated |
| Binding Capacity | >15 mg/mL human Fab fragment |
| For Use With (Application) | Chromatography |
| Product Line | CaptureSelect |