Direct PCR Reagents and Kits
- (2)
- (11)
- (3)
- (20)
- (12)
- (5)
- (2)
- (8)
- (1)
- (2)
- (2)
- (11)
- (5)
- (1)
- (1)
- (7)
- (1)
- (2)
- (14)
- (1)
- (1)
- (19)
- (4)
- (6)
- (2)
- (19)
- (7)
- (12)
- (6)
- (18)
- (12)
- (1)
- (1)
- (25)
- (2)
- (6)
Filtered Search Results
Invitrogen™ Cells-to-CT™ 1-Step Power SYBR™ Green Kit
Greener Choice
Offers one or more environmental benefits itemized in the U.S. FTC Green Guides.
Learn More
Offers one or more environmental benefits itemized in the U.S. FTC Green Guides.
Learn More
Like other members of the Cells-to-CT™ product family, the Cells-to-CT™ 1-Step Power SYBR™ Green Kit makes it possible to perform expression analysis directly from cultured cells without RNA purification.
| GC-Rich PCR Performance | High |
|---|---|
| Format | Tube |
| Product Type | 1-Step qPCR kit |
| For Use With (Equipment) | 7500 Fast System, 7500 System, 7900HT Fast System, 7900HT System, QuantStudio™, ViiA™ 7 System, StepOnePlus™ System, StepOne™ System, Real-Time PCR Systems or Thermal Cyclers, 7500 Fast Dx System, QuantStudio 6 and 7 Pro systems, QuantStudio 7 Flex system, QuantStudio 3 and 5 systems, QuantStudio 12k Flex system, QuantStudio 6 Flex system |
| Sample Type | Mammalian Cells |
| Reaction Speed | 7 min. |
| Reagent Type | Cell Lysis |
| Green Features | Fewer resources used and less waste, less hazardous |
| Starting Material | 10-100,000 Cells |
| For Use With (Application) | Gene Expression |
| PCR Method | 1-step RT-qPCR |
| Product Line | Cells-to-CT™, Power SYBR™ Green |
| Detection Method | SYBR |
Applied Biosystems™ CLA IdentiFiler™ Direct PCR Amplification Kit
The CLA (Cell Line Authentication) IdentiFiler Direct PCR Amplification Kit simplifies the amplification step during authentication of cell lines.
Thermo Scientific™ Phire Plant Direct PCR Kit (without sampling tools)
Thermo Scientific Phire Plant Direct PCR Kit is designed to amplify DNA directly from plant samples. No DNA purification is required prior to PCR.
Invitrogen™ SYBR™ Green Fast Advanced Cells-to-CT™ Kit
Greener Choice
Offers one or more environmental benefits itemized in the U.S. FTC Green Guides.
Learn More
Offers one or more environmental benefits itemized in the U.S. FTC Green Guides.
Learn More
The SYBR Green Fast Advanced Cells-to-Ct Kit is a complete cell lysate system designed for gene expression analysis directly from cultured cells without RNA purification.
| Shipping Condition | Dry Ice |
|---|---|
| GC-Rich PCR Performance | High |
| Fidelity (vs. Taq) | 2X |
| Green Features | Fewer resources used and less waste, Less hazardous |
| Concentration | 2X |
| For Use With (Application) | Gene Expression |
| High-throughput Compatibility | High-throughput Compatible |
| PCR Method | 2-step RT-qPCR |
| Detection Method | SYBR |
| Format | Tube |
| Product Type | Fast Advanced Cells-to-Ct Kit |
| Sample Type | Mammalian Cells |
| Reaction Speed | 7 min. |
| Reagent Type | Cell Lysis |
| Purification Target | Lysate |
| Starting Material | 10-100,000 Cells |
| Product Line | Cells-to-CT™ |
Invitrogen™ TaqMan™ Cells-to-CT™ Control Kit
Greener Choice
Offers one or more environmental benefits itemized in the U.S. FTC Green Guides.
Learn More
Offers one or more environmental benefits itemized in the U.S. FTC Green Guides.
Learn More
The Invitrogen™ TaqMan™ Cells-to-CT Control Kit is designed for use with the TaqMan™ Gene Expression Cells-to-CT Kit.
Invitrogen™ TaqMan™ PreAmp Cells-to-CT™ Kit
Greener Choice
Offers one or more environmental benefits itemized in the U.S. FTC Green Guides.
Learn More
Offers one or more environmental benefits itemized in the U.S. FTC Green Guides.
Learn More
The TaqMan PreAmp Cells-to-CT Kit makes it possible to perform gene expression analysis directly from limited or small numbers of cultured cells without RNA purification.
Invitrogen™ TaqMan™ Fast Cells-to-CT™ Kit
Greener Choice
Offers one or more environmental benefits itemized in the U.S. FTC Green Guides.
Learn More
Offers one or more environmental benefits itemized in the U.S. FTC Green Guides.
Learn More
The TaqMan™ Fast Cells-to-CT™ Kit makes it possible to use Fast-cycling, real-time PCR chemistry and instrumentation to perform gene expression analysis directly from cultured cells without RNA purification.
Invitrogen™ TaqMan™ MicroRNA Cells-to-CT™ Kit
Greener Choice
Offers one or more environmental benefits itemized in the U.S. FTC Green Guides.
Learn More
Offers one or more environmental benefits itemized in the U.S. FTC Green Guides.
Learn More
First to offer a simple, complete workflow for miRNA expression analysis from a few samples, or it can easily be incorporated into automated, high throughput applications.
Invitrogen™ SYBR™ Green Cells-to-CT™ Control Kit
Greener Choice
Offers one or more environmental benefits itemized in the U.S. FTC Green Guides.
Learn More
Offers one or more environmental benefits itemized in the U.S. FTC Green Guides.
Learn More
This kit is designed for use with the Power SYBRGreen and Fast SYBRGreen Cells-to-CT™ Kits with sufficient reagents are provided for 100 reactions.
Invitrogen™ Power SYBR™ Green Cells-to-CT™ Kit
Greener Choice
Offers one or more environmental benefits itemized in the U.S. FTC Green Guides.
Learn More
Offers one or more environmental benefits itemized in the U.S. FTC Green Guides.
Learn More
Ambion™ Power SYBR™ Green Cells-to-CT™ Kit is a fast, easy, and robust method to go directly from cultured cells to real-time PCR results.
| Shipping Condition | Dry Ice |
|---|---|
| Purity or Quality Grade | LD (Low DNA) |
| Reverse Transcriptase | M-MLV |
| Purification Time | 5 min. |
| Green Features | Fewer resources used and less waste, Less hazardous |
| Concentration | 20X |
| For Use With (Application) | RT-PCR |
| Detection Method | SYBR |
| Polymerase | AmpliTaq Gold DNA Polymerase |
| Passive Reference Dye | ROX (Pre-mixed) |
| For Use With (Equipment) | 7000 System, 7200 System, 7300 System, 7500 System, 7700 System, 7900HT System,Applied Biosystems StepOnePlus™ Fast Real-Time PCR System, GeneAmp 5700, GeneAmp 9600, StepOnePlus™, Standard Mode, QuantStudio 6 and 7 Pro systems, QuantStudio 7 Flex system, QuantStudio 3 and 5 systems, QuantStudio 12k Flex system, QuantStudio 6 Flex system |
| Sample Type | Cells |
| Reaction Speed | Standard |
| Label or Dye | SYBR Green |
| Hot Start | Built-In Hot Start |
| Product Line | Cells-to-CT™, SYBR™ |
Applied Biosystems™ SNaPshot™ Multiplex Kit
The SNaPshot™ Multiplex Kit is part of the SNaPshot™ Multiplex System. The SNaPshot™ Multiplex System primer extension-based method enables multiplexing up to 10 single nucleotide polymorphisms (SNPs).
| Product Type | Multiplex Kit |
|---|---|
| For Use With (Equipment) | 3500 Series Genetic Analyzers, SeqStudio Flex Series Genetic Analyzers, SeqStudio Genetic Analyzer, 3730/3730xl Genetic Analyzers |
| Sample Type | DNA |
| Technique | SNP Genotyping (Fragment Analysis-Based), Primer Extension |
| Product Line | SNaPshot™ |
| Detection Method | Primer-probe |
Invitrogen™ Cells-to-CT Bulk RT Reagents
Greener Choice
Offers one or more environmental benefits itemized in the U.S. FTC Green Guides.
Learn More
Offers one or more environmental benefits itemized in the U.S. FTC Green Guides.
Learn More
Cells-to-CT Bulk RT Reagents are separately-available, large-quantity versions of the reagents used for reverse transcription in the TaqMan™ Gene Expression Cells-to-CT™ Kit (20X RT enzyme mix and 20X RT buffer).
Invitrogen™ Cells-to-cDNA™ II Kit
The Ambion™ Cells-to-cDNA™ II Kit (patent pending) produces cDNA from cultured mammalian cells in less than 2 hr., no RNA isolation is required.
| Shipping Condition | Dry Ice |
|---|---|
| Content And Storage | 1X PBS, Cell Lysis II Buffer, μL DNase 1, 10X RT Buffer, M-mLV Reverse Transcriptase, RNase Inhibitor, dNTP Mix, Random Decamers, Oligo(dT)18 Primers, Armored RNA™ Control, Armored RNA™ Primer Pair, and Endogenous Primer Pair should be stored at -20°C. Nuclease-free water may be stored at any temperature. |
| Reverse Transcriptase | M-MLV |
| Size (Final Product) | 7 kb or less |
| Final Product Type | cDNA |
| Sample Type | Mammalian Cells |
| Purification Time | 2 hr. |
| Optimal Reaction Temperature | 42°C |
| For Use With (Application) | Real Time PCR (qPCR),RT-PCR |
| Product Line | Ambion™, Cells-to-cDNA™ |