Chromatography Syringes
Syringes for manual or autosampler injections, in a variety of sizes, needle gauges, point styles, and terminations; includes electronic and manual gas tight syringes, HPLC general syringes, and replacement parts and accessories. Choose from leading brands for analytical gas and liquid syringes. Specialty syringes designed for unique applications are also available.
Filtered Search Results
Hamilton™ Needles, 2 in., Sold by MilliporeSigma™ Supelco™
For use with Removable Needle (RN) Syringes
| For Use With (Equipment) | Removable Needle Syringe |
|---|---|
| Product Type | Needle |
| Volume (Metric) | 250 to 10,000 μL |
| Quantity | 6 Pk. |
| Material | Stainless Steel (Tip) |
| Length (English) Needle | 2 in. |
| Length (Metric) Needle | 51 mm |
Hamilton™ Gastight™ Digital Syringe, Sold by MilliporeSigma™ Supelco™
This N.I.S.T. traceable, calibrated syringe device provides constant injection rate and includes a removable, 2 in. (51 mm) bevel tip needle.
| Needle Point Number | 2 |
|---|---|
| Product Type | N.I.S.T. Traceable Calibrated Syringe |
| Needle Point Style | Bevel |
| Quantity | 1 Ea. |
| Min. Temperature (English) | 50°F |
| Length (English) Needle | 2 in. |
| Length (Metric) Needle | 51 mm |
| Min. Temperature (Metric) | 10°C |
| Product Line | Hamilton |
MilliporeSigma™ Supelco™ SGE Guided Plunger Syringes
Extended barrel guides plunger during injection
| Needle Point Number | 2 |
|---|---|
| Product Type | SGE Guided Plunger Syringe |
| Needle Point Style | Bevel |
| Quantity | 1 Ea. |
| Diameter (Metric) Outer Needle | 0.47 mm |
| Material | Stainless Steel (Tip) |
| Length (Metric) Needle | 50 mm |
| Needle Gauge | 26 G |
MilliporeSigma™ Supelco™ SGE MicroVolume Syringes, Standard Plunger
Equipped with bevel tip needles, designed for optimum septum penetration and to prevent septum coring
| Needle Point Number | 2 |
|---|---|
| Description | Standard Plunger |
| Product Type | SGE Microvolume Syringe |
| Connection Type | Fixed |
| Needle Point Style | Bevel |
| Quantity | 1 Ea. |
| Material | Stainless Steel (Tip) |
| Length (Metric) Needle | 50 mm |
| Needle Gauge | 25 G |
MilliporeSigma™ Supelco™ SGE Plunger-Protected Syringe, Removable Needle (RN)
With a Bevel Tip, Stainless Steel Needle
| Needle Point Number | 2 |
|---|---|
| Product Type | SGE Plunger-Protected Syringe |
| Connection Type | Removable |
| Needle Point Style | Bevel |
| Quantity | 1 Ea. |
| Material | Stainless Steel (Tip) |
| Length (Metric) Needle | 50 mm |
| Needle Gauge | 26 G |
SGE Gastight™ Syringe, Fixed Needle (LTN), Sold by MilliporeSigma™ Supelco™
Suitable for manual dispenser/diluter applications. Maximum inertness for liquid or gas samples.
| Needle Point Number | 2 |
|---|---|
| Needle Point Style | Bevel |
| Quantity | 1 Ea. |
| Material | Borosilicate Glass (Barrel),PTFE (Plunger),Stainless Steel (Tip) |
| Length (Metric) Needle | 50 mm |
Hamilton™ Gastight™ Syringe, 10 μL, Sold by MilliporeSigma™ Supelco™
Gas-tight design minimizes gas exchange during GC analysis. Syringes provide accurate volume delivery with a plunger that is mostly unsurpassed.
| Product Type | Gastight™ Syringe |
|---|---|
| Volume (Metric) | 10 μL |
| Quantity | 1 Ea. |
| Min. Temperature (English) | 50°F |
| Min. Temperature (Metric) | 10°C |
| Max. Pressure | 1000 psig (68.9 bar) |
| Product Line | Hamilton |
Hamilton™ 1000 Series Syringe, Sold by MilliporeSigma™ Supelco™
Gas-tight design minimizes the gas exchange in GC analysis. Syringes provide accurate volume delivery with a plunger that is mostly unsurpassed.
| Needle Point Number | 2 |
|---|---|
| Quantity | 1 Ea. |
| Min. Temperature (English) | 50°F |
| Material | Borosilicate Glass (Barrel),PTFE (Plunger),Stainless Steel (Tip) |
| Max. Temperature (Metric) | 50°C |
| Length (Metric) Needle | 51 mm |
| Max. Pressure | 200 psig (13.8 bar) |
| Diameter (Metric) Inner Needle | 0.41 mm |
| Product Type | Gastight™ Syringe |
| Connection Type | Luer Tip, Cemented |
| Max. Temperature (English) | 122°F |
| Needle Point Style | Bevel |
| Diameter (Metric) Outer Needle | 0.72 mm |
| Length (English) Needle | 2 in. |
| Autoclavable | Not Autoclavable |
| Min. Temperature (Metric) | 10°C |
| Needle Gauge | 22 G |
| Diameter (English) Outer Needle | 0.0283 in. |
| Diameter (English) Inner Needle | 0.0161 in. |
| Product Line | Hamilton |
Hamilton™ HPLC Syringes, Sold by MilliporeSigma™ Supelco™
May be used for extraction and injection of sample material
| Needle Point Number | 3 |
|---|---|
| Quantity | 1 Ea. |
| Min. Temperature (English) | 50°F |
| Material | Borosilicate Glass (Barrel),PTFE (Plunger),Stainless Steel (Tip) |
| Max. Temperature (Metric) | 115°C |
| Length (Metric) Needle | 51 mm |
| For Use With (Equipment) | Rheodyne, SSI, and Valco VISF-2 |
| Product Type | Gastight™ Syringe |
| Connection Type | Removable |
| Max. Temperature (English) | 239°F |
| Needle Point Style | Blunt |
| Diameter (Metric) Outer Needle | 0.72 mm |
| Length (English) Needle | 2 in. |
| Autoclavable | Autoclavable |
| Min. Temperature (Metric) | 10°C |
| Diameter (English) Outer Needle | 0.0283 in. |
| Product Line | Hamilton |
Hamilton™ 1000 Series Syringe, Without Needle, Sold by MilliporeSigma™ Supelco™
Gas-tight design minimizes the gas exchange in GC analysis. Syringes provide accurate volume delivery with a plunger that is mostly unsurpassed. Tip is threaded in a luer lock syringe which allows the needle to be tightly screwed to the tip.
| Product Type | Gastight™ Syringe |
|---|---|
| Quantity | 1 Ea. |
| Product Line | Hamilton |
SGE Autosampler Syringe, SuperfleX™ Syringe, Sold by MilliporeSigma™ Supelco™
For use with Agilent/HP 7673 and 7683 Autosamplers
Hamilton™ 700 Series Syringe, 10 μL, Sold by MilliporeSigma™ Supelco™
Includes a 2 in. Stainless Steel, Removable Needle
| Needle Point Number | 2 |
|---|---|
| Description | 700 Series |
| Product Type | Syringe |
| Volume (Metric) | 10 μL |
| Needle Point Style | Bevel |
| Material | Stainless Steel (Tip) |
| Length (English) Needle | 2 in. |
| Length (Metric) Needle | 51 mm |
| Product Line | Hamilton |
MilliporeSigma™ Supelco™ Syringes with Removable Needle Valve
Feature an interference fit between the plunger tip and the barrel, which enhances the gas sealing properties of the syringe
| Needle Point Number | 2 |
|---|---|
| Description | Needle Valve in Hub |
| Product Type | Syringe |
| Needle Point Style | Bevel |
| Quantity | 1 Ea. |
| Diameter (Metric) Outer Needle | 0.63 mm |
| Autoclavable | Autoclavable |
| Length (Metric) Needle | 50 mm |
| Needle Gauge | 23 G |
MilliporeSigma™ Supelco™ SGE Syringes, Cone Tip
For use with Agilent/HP 7673, 7683 and 6850 ALS Autosamplers
| Needle Point Number | 1 |
|---|---|
| For Use With (Equipment) | Agilent 7673, 7683, 6850 ALS Autosampler |
| Product Type | SGE Syringe |
| Needle Point Style | Cone |
| Material | Stainless Steel (Tip) |
| Length (Metric) Needle | 42 mm |