Protein Purification Reagents and Kits
- (2)
- (24)
- (21)
- (2)
- (2)
- (12)
- (2)
- (1)
- (6)
- (11)
- (10)
- (50)
- (4)
- (4)
- (44)
- (1)
- (1)
- (3)
- (1)
- (2)
- (2)
- (1)
- (2)
- (8)
- (11)
- (2)
- (3)
- (4)
- (5)
- (1)
- (1)
- (1)
- (1)
- (37)
- (2)
- (3)
- (1)
- (2)
- (1)
- (3)
- (1)
- (1)
- (27)
- (13)
- (6)
- (2)
- (3)
- (1)
- (1)
- (1)
- (4)
- (4)
- (7)
- (1)
- (8)
- (148)
- (2)
- (2)
- (3)
- (2)
- (3)
- (27)
- (1)
- (1)
- (2)
- (27)
- (66)
- (1)
- (1)
- (5)
- (10)
- (4)
- (2)
- (12)
- (3)
- (3)
- (8)
- (91)
- (50)
- (2)
- (1)
- (4)
- (7)
- (16)
- (9)
- (4)
- (4)
- (32)
- (12)
- (22)
- (6)
- (3)
- (4)
- (3)
- (33)
- (5)
- (4)
- (2)
- (1)
- (1)
- (1)
- (4)
- (10)
- (2)
- (1)
- (2)
- (1)
- (1)
- (5)
- (1)
- (3)
- (14)
- (3)
- (1)
- (1)
- (1)
- (3)
- (3)
- (1)
- (2)
- (5)
- (1)
- (1)
- (2)
- (1)
- (3)
- (6)
- (2)
- (4)
- (1)
- (2)
- (3)
- (1)
- (4)
- (2)
- (1)
- (1)
- (1)
- (1)
- (1)
- (5)
Filtered Search Results
Thermo Scientific™ His-Tag Magnetic Agarose Purification Bundle
His-Tag Magnetic Agarose Purification Bundle combines optimized reagents for successful purification of His-Tagged proteins from bacterial culture. The bundle includes Pierce Ni-NTA Magnetic Agarose beads, B-PER Complete Bacterial protein extraction reagent and Halt Protease Inhibitor Cocktail
Thermo Scientific™ Pierce™ Anti-DYKDDDDK Affinity Resin
Pierce Anti-DYKDDDDK Spin Columns provide a fast, convenient method for purification of DYKDDDDK-tagged proteins expressed in in vitro protein expression systems, bacteria, yeast, and mammalian cells.
| Shipping Condition | Wet Ice |
|---|---|
| Stationary Phase | Anti-DYKDDDDK monoclonal antibodies |
| Product Type | Affinity Resin |
Thermo Scientific™ Neucode™ Lysine-202
Increase the level of multiplexing achievable with NeuCode™ amino acids for the metabolic labeling of proteins for mass spectrometry analysis.
Thermo Scientific™ HisPur™ Cobalt Spin Columns, 3 mL
Gently purify His-tagged recombinant fusion proteins using cobalt (Co2+) immobilized metal chelate affinity (IMAC) beads, spin columns and plates.
Thermo Scientific™ Nuclear and Cytoplasmic Protein Extraction Bundle
Nuclear and Cytoplasmic Protein Extraction Bundle provides a simple method for extracting nuclear and cytoplasmic proteins and high-precision total protein concentration determination. The bundle includes Thermo Scientific NE-PER Kit, Halt Protease Inhibitor Cocktail and Micro BCA Protein Assay Kit
Thermo Scientific™ HisPur™ Ni-NTA Resin
Purify His-tagged recombinant fusion proteins using high-capacity nickel-NTA (nitrilotriacetic acid) metal-chelate beads, spin columns and plates.
| Stationary Phase | Divalent Nickel, Metal Chelate |
|---|---|
| Type | Resin |
| Target | His-Tagged Protein |
| Content And Storage | Store at 4°C |
| Format | Bottle |
| Description | HisPur Ni-NTA Resin |
| Form | Liquid Suspension |
| Column Type | Affinity, Agarose Resin |
| Capacity (Metric) | Up to 60 mg of 6xHis-Tagged Protein Binding per mL Resin |
| Product Line | HisPur |
Thermo Scientific™ HisPur™ Ni-NTA Spin Columns, 1 mL
Purify His-tagged recombinant fusion proteins using high-capacity nickel-NTA (nitrilotriacetic acid) metal-chelate beads, spin columns and plates.
Thermo Scientific™ Pierce™ Tissue Strainers, 250 μm, 2.5 mL
Rapidly separate cells or cell lysate from tissue debris after mechanical disruption using a 250-micron mesh filter and gravity or gentle centrifugation.
Thermo Scientific™ Detergent Removal Spin Columns & Plates
Rapidly eliminate high concentrations of detergents with minimal sample loss with detergent removal resins. Thermo Scientific HiPPR (High Protein and Peptide Recovery) resin is recommended for protein concentrations up to 100 μg/mL, while Thermo Scientific Pierce resin is suitable for concentrations over 100 μg/mL.
| Stationary Phase | Proprietary Ligand |
|---|---|
| Column Type | Proprietary Resin, Affinity |
| Purification Target | Detergent Removal |
Thermo Scientific™ Pierce™ Crosslink Magnetic IP/Co-IP Kit
Immunoprecipitate target proteins without antibody contamination by crosslinking IP antibodies to Protein A/G magnetic beads.
Thermo Scientific™ Pierce™ Glycoprotein Isolation Kit, WGA
Purify glycoproteins from serum and cell lysates using affinity resins or kits with concanavilin A (ConA) or wheat germ agglutinin (WGA) lectins.
Thermo Scientific™ HisPur™ Ni-NTA Chromatography Cartridges, 1 mL
Purify His-tagged recombinant fusion proteins using high-capacity nickel-NTA (nitrilotriacetic acid) metal-chelate beads, spin columns and plates.
| Stationary Phase | Divalent Nickel, Metal Chelate |
|---|---|
| Type | Chromatography Cartridge |
| Target | His-Tagged Protein |
| Content And Storage | Store between 4°C and 8°C. Do not freeze. |
| Column Type | Affinity, Agarose Resin |
| Product Line | HisPur |
Thermo Scientific™ Pierce™ 3x DYKDDDDK Peptide
Tricosa-peptide for competitively eluting DYKDDDK-tagged fusion proteins from immobilized supports
| Shipping Condition | Wet Ice |
|---|---|
| Format | Lyophilized Powder |
| Form | Lyophilized Powder |
| Protein Form | Recombinant |
| Product Type | Peptides |
| dimMatrix | Affinity Resin |
| For Use With (Application) | Protein Purification and Isolation |
| Product Line | Pierce |
Thermo Scientific™ HisPur™ Cobalt Resin
Gently purify His-tagged recombinant fusion proteins using cobalt (Co2+) immobilized metal chelate affinity (IMAC) beads, spin columns and plates.
| Stationary Phase | Metal Chelate, Divalent Cobalt |
|---|---|
| Type | Resin |
| Target | His-Tagged Protein |
| Content And Storage | Store at 4°C |
| Format | Bottle |
| Protein Form | Recombinant |
| Form | Liquid Suspension |
| Column Type | Affinity, Agarose Resin |
| Product Line | HisPur |
Invitrogen™ Intact Virus Precipitation Reagent
Intact Virus Precipitation Reagent wnables fast and efficient enrichment of intact, live SARS-CoV-2 coronavirus from dilute cell culture and virus transport media.