UserName
Redox-based viability probe
Formulated and optimized for staining with antibodies against transcription factors and nuclear proteins (e.g. Foxp3 and Ki-67), cytokines and chemokines
Designed for use in compensation with all fluorochromes excited by ultraviolet, violet, blue, green, yellow-green, and red lasers. UltraComp eBeads™ react with antibodies of mouse, rat, and hamster origin, and are immunoglobulin light chain-independent. 1 drop (50μL)/test.
À utiliser avec (équipement) | Flow Cytometer |
---|---|
Type de produit | Compensation Beads |
Gamme de produits | eBeads™ |
Monitor cell proliferation and viability with the resazurin-based PrestoBlue and PrestoBlue HS cell viability reagents. These nontoxic and cell permeable reagents quantitatively measure cell viability in as little as 10 minutes using absorbance- or fluorescence-based microplate readers.
Méthode de détection | Colorimetric, Fluorescence |
---|---|
À utiliser avec (équipement) | Microplate Reader,Spectrophotometer,HTS Reader |
Gamme de produits | PrestoBlue |
Forme | Liquid |
À utiliser avec (application) | Viability Assay |
Contenu et stockage | Store at 2°C to 8°C and protect from light. |
MTT (3-(4,5-Dimethylthiazol-2-yl)-2,5-Diphenyltetrazolium Bromide)
DAPI and Hoechst are classic popular nuclear counterstains for use in all fluorescent cell and tissue techniques. The blue fluorescence is vivid contrast to green, yellow, orange, red, far red and NIR fluorescent probes and labels.
Méthode de détection | Fluorescence |
---|---|
Couleur | Blue |
Type d’étiquette | Fluorescent Dye |
Conditions d’expédition | Room Temperature |
Dynabeads Mouse T-Activator CD3/CD28 beads are 4.5-μm superparamagnetic beads covalently coupled with an optimized combination of anti-mouse CD3 and anti-mouse CD28 antibodies and intended for ex vivo activation and expansion/proliferation of mouse T cells.
Certifications/Conformité | ISO9001 and ISO13485 |
---|---|
À utiliser avec (équipement) | DynaMag™ Magnet |
Description | Monoclonal antibodies covalently bound to DynaBeads magnetic Beads |
Technologie d’isolement | Magnetic Beads |
Type de produit | Cell Expansion and Activation Kit |
Matériau | Magnetic Polystyrene |
Type d’échantillon | Cell Cultures, Lymph Node, Spleen |
Diamètre (métrique) | 4.5 μm |
Espèces cibles | Mouse T-cells |
Concentration | 4 x 10 7 Beads/mL |
Réactivité | Mouse |
Uniformité | Monosized 4.5 μm (CV <5%) |
Conditions d’expédition | Ambient Temperature |
Fonctionnalité de surface | Epoxy |
À utiliser avec (application) | Activation and Expansion of T-cells |
État réglementaire | For Research Use Only |
Couleur | Brown |
Clonalité | Monoclonal |
Gamme de produits | DynaBeads™ |
Espèces hôtes | Hamster |
Type de cellule | Mouse T-cells |
Durée de conservation | 36 months from date of manufacture |
LIVE/DEAD™ BacLight™ Bacterial Viability Kits are easy-to-use fluorescent staining kits commonly used for assessing the viability of bacterial cells. These kits provide a two-color fluorescence assay of bacterial viability using green and red fluorescent dyes for use with imaging, flow, and assays.
Méthode de détection | Fluorescence |
---|---|
Type de produit | Bacterial Viability Kit |
Gamme de produits | BacLight, LIVE/DEAD |
Type de cellule | Bacteria |
Conditions d’expédition | Room Temperature |
Type de colorant | Other Label(s) or Dye(s) |
CountBright™ Absolute Counting Beads, for flow cytometry
Calcein AM is a cell-permeant dye that can be used to determine cell viability in most eukaryotic cells. In live cells, the non-fluorescent Calcein AM is converted to green or blue fluorescent Calcein, after acetoxymethyl ester hydrolysis by intracellular esterases.
Type de réactif | Cell Tracker Compounds, Cell Labeling Reagents |
---|---|
À utiliser avec (équipement) | Fluorescence Microscope |
Conditions d’expédition | Room Temperature |
Type de colorant | Other Label(s) or Dye(s) |
À utiliser avec (application) | Cell Tracing,Cell Tracker |
Contenu et stockage | Store in freezer (-5°C to -30°C) and protect from light. |
Detect early stages of apoptosis with Annexin V stand-alone Alexa Fluor, APC, Pacific Blue, PE, FITC, and biotin conjugates using flow cytometry.
À utiliser avec (équipement) | Flow Cytometer |
---|---|
Type de produit | Annexin V conjugate |
Conditions d’expédition | Wet Ice |
Useful with a variety of fluorescence-detection methodologies
Dynabeads E. coli anti-O157 is a tool for better sample preparation and improved cell culture and immuno-based assays for E. coli O157:H7 in food, feces, water and other environmental samples.
À utiliser avec (équipement) | Dynabeads™ MPC™, KingFisher mL Food Protection Purification System, DynaMag™-2 |
---|---|
Technologie d’isolement | Immunomagnetic Separation |
Type de produit | Anti-E.coli O157 Bead |
Gamme de produits | Dynabeads™ |
Échelle de préparation | Small Volume Microbial Samples |
Conditions d’expédition | Room Temperature |
The LIVE/DEAD™ Fixable Aqua Dead Cell Stain Kit is used to determine the viability of cells prior to the fixation and permeabilization required for intracellular antibody staining, or prior to elimination of biohazardous materials using formaldehyde fixation.
Méthode de détection | Fluorescence |
---|---|
dimExcitationWavelengthRange | 375 nm |
À utiliser avec (équipement) | Flow Cytometer |
Description | LIVE/DEAD™ Fixable Aqua Dead Cell Stain Kit, for 405 nm excitation |
Perméabilité cellulaire | Impermeant |
Type de produit | Stain |
Emission | 526 |
Conditions d’expédition | Room Temperature |
Forme | Solid |
À utiliser avec (application) | Viability Assay |
Couleur | Aqua |
Gamme de produits | LIVE/DEAD |
Type de cellule | Eukaryotic Cells |
Type de colorant | LIVE/DEAD™ Fixable Aqua Dead Cell Stain |
Useful indicator of dead cells within a population