Industrial Hygiene and Environmental Monitoring
Résultats de la recherche filtrée
| Longueur (métrique) | 20cm |
|---|---|
| Hauteur (impériale) | 2.25 in. |
| Type de produit | Beta sample box |
| Capacité | 36 Tubes |
| Matériau | Acrylic |
| Dimensions (L x l x H) | 8 x 4 x 2.25 in. (20 x 10 x 5.7cm) |
| À utiliser avec (application) | To allow icing of samples if desired, store and transport samples |
| Longueur (impériale) | 8 in. |
| Couleur | Clear |
| Largeur (métrique) | 10cm |
| Hauteur (métrique) | 5.7cm |
| Épaisseur (impériale) | 0.37 in. |
| Comprend | Radiation label, non-skid feet |
| Largeur (impériale) | 4 in. |
Fisherbrand™ Mobile Beta Storage Container
Suitable for beta protection and industrial mobile storage.
Fisherbrand™ Traceable™ Sound Level Meter
Meter receives sound through a 1/2 in. condenser microphone.
PDM3700 Personal Dust Monitor
This personal dust monitor is a real-time portable respirable dust monitor designed to alert mine workers to unsafe levels of dust exposure.
Thermo Scientific™ TVA2020 Toxic Vapor Analyzer - Dual FID/PID with Enhanced & Sampling Probes
Quickly detect organic and inorganic compounds in demanding applications such as Method 21 monitoring and site remediation.
| Hauteur (impériale) | 11.5 in. |
|---|---|
| Certifications/Conformité | USA: Class I, Division 1, Groups A,B,C,D T3; Canada: Class I, Zone 1, Ex db ib IIC T3 Gb; ATEX: CE0359 Ex II 2 G Ex db ib IIC T3 Gb; IECEx: Ex db ib IIC T3 Gb |
| Précision | FID Instrument - ±10% of reading or ±1.0 ppm, whichever is greater, from 1.0 to 10,000 ppm; PID Instrument - ±20 % of reading or ±0.5 ppm, whichever is greater, from 0.5 to 500 ppm |
| Garantie | One year from date of shipment |
| Temps de réponse | FID: Less than 3.5 seconds for 90% of final value, using 10,000 ppm of methane; PID: Less than 3.5 seconds for 90% of final value, using 500 ppm of isobutylene |
| Fréquence | 50/60 Hz |
| Type de batterie | Lithium-ion |
| Interface série | USB |
| Profondeur (impériale) | 4 in. |
| Tension | 120 V |
| Largeur (impériale) | 9 in. |
| Reproductibilité | FID: ±2% at 500 ppm of methane; PID: ±1% at 100 ppm of isobutylene |
| Points de données | Auto mode - 1 per second to 1 per 999 minutes, user selectable; VOC or FE Mode - 2 to 30 seconds, user selectable |
| Composants mesurés | Most Organic and Inorganic Compounds |
| Débit | 1 L/min., nominal at sample probe inlet |
| Contraintes informatiques | USB port, Windows XP operating system or higher |
| Limites de détection | FID: 0.5 ppm of methane; PID: 0.5 ppm of isobutylene |
| Concentration | FID: 0 to 30,000 ppm (methane); PID: 0 to 2000 ppm (isobutylene) |
| Largeur (métrique) | 22.9 cm |
| Hauteur (métrique) | 29.2 cm |
| Combustible | 99.99% H2 for FID |
| Autonomie en mode portable | Minimum 10 hours |
| Plage de températures (métrique) | -10°C to 45°C |
| Autonomie de la batterie | 10 hours at 0°C |
| Plage de températures (impériale) | 14°F to 113°F |
| Type de détecteur | Dual Configured with FID and PID |
| Profondeur (métrique) | 10.2 cm |
Thermo Scientific™ TVA2020 Toxic Vapor Analyzer - Dual FID/PID with Sampling Probe
Quickly detect organic and inorganic compounds in demanding applications such as Method 21 monitoring and site remediation.
| Hauteur (impériale) | 11.5 in. |
|---|---|
| Certifications/Conformité | USA: Class I, Division 1, Groups A,B,C,D T3; Canada: Class I, Zone 1, Ex db ib IIC T3 Gb; ATEX: CE0359 Ex II 2 G Ex db ib IIC T3 Gb; IECEx: Ex db ib IIC T3 Gb |
| Précision | FID Instrument - ±10% of reading or ±1.0 ppm, whichever is greater, from 1.0 to 10,000 ppm; PID Instrument - ±20 % of reading or ±0.5 ppm, whichever is greater, from 0.5 to 500 ppm |
| Garantie | One year from date of shipment |
| Temps de réponse | FID: Less than 3.5 seconds for 90% of final value, using 10,000 ppm of methane; PID: Less than 3.5 seconds for 90% of final value, using 500 ppm of isobutylene |
| Fréquence | 50/60 Hz |
| Type de batterie | Lithium-ion |
| Interface série | USB |
| Profondeur (impériale) | 4 in. |
| Tension | 120 V |
| Largeur (impériale) | 9 in. |
| Reproductibilité | FID: ±2% at 500 ppm of methane; PID: ±1% at 100 ppm of isobutylene |
| Points de données | Auto mode - 1 per second to 1 per 999 minutes, user selectable; VOC or FE Mode - 2 to 30 seconds, user selectable |
| Composants mesurés | Most Organic and Inorganic Compounds |
| Débit | 1 L/min., nominal at sample probe inlet |
| Contraintes informatiques | USB port, Windows XP operating system or higher |
| Limites de détection | FID: 0.5 ppm of methane; PID: 0.5 ppm of isobutylene |
| Concentration | FID: 0 to 30,000 ppm (methane); PID: 0 to 2000 ppm (isobutylene) |
| Largeur (métrique) | 22.9 cm |
| Hauteur (métrique) | 29.2 cm |
| Combustible | 99.99% H2 for FID |
| Autonomie en mode portable | Minimum 10 hours |
| Plage de températures (métrique) | -10°C to 45°C |
| Autonomie de la batterie | 10 hours at 0°C |
| Plage de températures (impériale) | 14°F to 113°F |
| Type de détecteur | Dual Configured with FID and PID |
| Profondeur (métrique) | 10.2 cm |
Thermo Scientific™ TVA2020 Toxic Vapor Analyzer - Dual FID/PID (No Probes)
Quickly detect organic and inorganic compounds in demanding applications such as Method 21 monitoring and site remediation.
| Hauteur (impériale) | 11.5 in. |
|---|---|
| Certifications/Conformité | USA: Class I, Division 1, Groups A,B,C,D T3; Canada: Class I, Zone 1, Ex db ib IIC T3 Gb; ATEX: CE0359 Ex II 2 G Ex db ib IIC T3 Gb; IECEx: Ex db ib IIC T3 Gb |
| Précision | FID Instrument - ±10% of reading or ±1.0 ppm, whichever is greater, from 1.0 to 10,000 ppm; PID Instrument - ±20 % of reading or ±0.5 ppm, whichever is greater, from 0.5 to 500 ppm |
| Garantie | One year from date of shipment |
| Temps de réponse | FID: Less than 3.5 seconds for 90% of final value, using 10,000 ppm of methane; PID: Less than 3.5 seconds for 90% of final value, using 500 ppm of isobutylene |
| Fréquence | 50/60 Hz |
| Type de batterie | Lithium-ion |
| Interface série | USB |
| Profondeur (impériale) | 4 in. |
| Tension | 120 V |
| Largeur (impériale) | 9 in. |
| Reproductibilité | FID: ±2% at 500 ppm of methane; PID: ±1% at 100 ppm of isobutylene |
| Points de données | Auto mode - 1 per second to 1 per 999 minutes, user selectable; VOC or FE Mode - 2 to 30 seconds, user selectable |
| Composants mesurés | Most Organic and Inorganic Compounds |
| Débit | 1 L/min., nominal at sample probe inlet |
| Contraintes informatiques | USB port, Windows XP operating system or higher |
| Limites de détection | FID: 0.5 ppm of methane; PID: 0.5 ppm of isobutylene |
| Concentration | FID: 0 to 30,000 ppm (methane); PID: 0 to 2000 ppm (isobutylene) |
| Largeur (métrique) | 22.9 cm |
| Hauteur (métrique) | 29.2 cm |
| Combustible | 99.99% H2 for FID |
| Autonomie en mode portable | Minimum 10 hours |
| Plage de températures (métrique) | -10°C to 45°C |
| Autonomie de la batterie | 10 hours at 0°C |
| Plage de températures (impériale) | 14°F to 113°F |
| Type de détecteur | Dual Configured with FID and PID |
| Profondeur (métrique) | 10.2 cm |
Thermo Scientific™ TVA2020 Toxic Vapor Analyzer - Dual FID/PID with Enhanced Probe
Quickly detect organic and inorganic compounds in demanding applications such as Method 21 monitoring and site remediation.
| Hauteur (impériale) | 11.5 in. |
|---|---|
| Certifications/Conformité | USA: Class I, Division 1, Groups A,B,C,D T3; Canada: Class I, Zone 1, Ex db ib IIC T3 Gb; ATEX: CE0359 Ex II 2 G Ex db ib IIC T3 Gb; IECEx: Ex db ib IIC T3 Gb |
| Précision | FID Instrument - ±10% of reading or ±1.0 ppm, whichever is greater, from 1.0 to 10,000 ppm; PID Instrument - ±20 % of reading or ±0.5 ppm, whichever is greater, from 0.5 to 500 ppm |
| Garantie | One year from date of shipment |
| Temps de réponse | FID: Less than 3.5 seconds for 90% of final value, using 10,000 ppm of methane; PID: Less than 3.5 seconds for 90% of final value, using 500 ppm of isobutylene |
| Fréquence | 50/60 Hz |
| Type de batterie | Lithium-ion |
| Interface série | USB |
| Profondeur (impériale) | 4 in. |
| Tension | 120 V |
| Largeur (impériale) | 9 in. |
| Reproductibilité | FID: ±2% at 500 ppm of methane; PID: ±1% at 100 ppm of isobutylene |
| Points de données | Auto mode - 1 per second to 1 per 999 minutes, user selectable; VOC or FE Mode - 2 to 30 seconds, user selectable |
| Composants mesurés | Most Organic and Inorganic Compounds |
| Débit | 1 L/min., nominal at sample probe inlet |
| Contraintes informatiques | USB port, Windows XP operating system or higher |
| Limites de détection | FID: 0.5 ppm of methane; PID: 0.5 ppm of isobutylene |
| Concentration | FID: 0 to 30,000 ppm (methane); PID: 0 to 2000 ppm (isobutylene) |
| Largeur (métrique) | 22.9 cm |
| Hauteur (métrique) | 29.2 cm |
| Combustible | 99.99% H2 for FID |
| Autonomie en mode portable | Minimum 10 hours |
| Plage de températures (métrique) | -10°C to 45°C |
| Autonomie de la batterie | 10 hours at 0°C |
| Plage de températures (impériale) | 14°F to 113°F |
| Type de détecteur | Dual Configured with FID and PID |
| Profondeur (métrique) | 10.2 cm |
Thermo Scientific™ TVA2020 Toxic Vapor Analyzer - FID Only with Enhanced Probe
Quickly detect organic and inorganic compounds in demanding applications such as Method 21 monitoring and site remediation.
| Hauteur (impériale) | 11.5 in. |
|---|---|
| Certifications/Conformité | USA: Class I, Division 1, Groups A,B,C,D T3; Canada: Class I, Zone 1, Ex db ib IIC T3 Gb; ATEX: CE0359 Ex II 2 G Ex db ib IIC T3 Gb; IECEx: Ex db ib IIC T3 Gb |
| Précision | ±10% of reading or ±1.0 ppm, whichever is greater, from 1.0 to 10,000 ppm |
| Garantie | One year from date of shipment |
| Temps de réponse | Less than 3.5 seconds for 90% of final value, using 10,000 ppm of methane |
| Fréquence | 50/60 Hz |
| Type de batterie | Lithium-ion |
| Interface série | USB |
| Profondeur (impériale) | 4 in. |
| Tension | 120 V |
| Largeur (impériale) | 9 in. |
| Reproductibilité | ±2% at 500 ppm of methane |
| Points de données | Auto mode - 1 per second to 1 per 999 minutes, user selectable; VOC or FE Mode - 2 to 30 seconds, user selectable |
| Composants mesurés | Most Organic and Inorganic Compounds |
| Débit | 1 L/min., nominal at sample probe inlet |
| Contraintes informatiques | USB port, Windows XP operating system or higher |
| Limites de détection | 0.5 ppm of methane |
| Concentration | 0 to 30,000 ppm (methane) |
| Largeur (métrique) | 22.9 cm |
| Hauteur (métrique) | 29.2 cm |
| Combustible | 99.99% H2 for FID |
| Autonomie en mode portable | Minimum 10 hours |
| Plage de températures (métrique) | -10°C to 45°C |
| Autonomie de la batterie | 10 hours at 0°C |
| Plage de températures (impériale) | 14°F to 113°F |
| Type de détecteur | Flame Ionization Detector (FID) |
| Profondeur (métrique) | 10.2 cm |
Thermo Scientific™ TVA2020 Toxic Vapor Analyzer - FID Only (No Probes)
Quickly detect organic and inorganic compounds in demanding applications such as Method 21 monitoring and site remediation.
| Hauteur (impériale) | 11.5 in. |
|---|---|
| Certifications/Conformité | USA: Class I, Division 1, Groups A,B,C,D T3; Canada: Class I, Zone 1, Ex db ib IIC T3 Gb; ATEX: CE0359 Ex II 2 G Ex db ib IIC T3 Gb; IECEx: Ex db ib IIC T3 Gb |
| Précision | ±10% of reading or ±1.0 ppm, whichever is greater, from 1.0 to 10,000 ppm |
| Garantie | One year from date of shipment |
| Temps de réponse | Less than 3.5 seconds for 90% of final value, using 10,000 ppm of methane |
| Fréquence | 50/60 Hz |
| Type de batterie | Lithium-ion |
| Interface série | USB |
| Profondeur (impériale) | 4 in. |
| Tension | 120 V |
| Largeur (impériale) | 9 in. |
| Reproductibilité | ±2% at 500 ppm of methane |
| Points de données | Auto mode - 1 per second to 1 per 999 minutes, user selectable; VOC or FE Mode - 2 to 30 seconds, user selectable |
| Composants mesurés | Most Organic and Inorganic Compounds |
| Débit | 1 L/min., nominal at sample probe inlet |
| Contraintes informatiques | USB port, Windows XP operating system or higher |
| Limites de détection | 0.5 ppm of methane |
| Concentration | 0 to 30,000 ppm (methane) |
| Largeur (métrique) | 22.9 cm |
| Hauteur (métrique) | 29.2 cm |
| Combustible | 99.99% H2 for FID |
| Autonomie en mode portable | Minimum 10 hours |
| Plage de températures (métrique) | -10°C to 45°C |
| Autonomie de la batterie | 10 hours at 0°C |
| Plage de températures (impériale) | 14°F to 113°F |
| Type de détecteur | Flame Ionization Detector (FID) |
| Profondeur (métrique) | 10.2 cm |
Thermo Scientific™ TVA2020 Toxic Vapor Analyzer - FID Only with Sampling Probe
Quickly detect organic and inorganic compounds in demanding applications such as Method 21 monitoring and site remediation.
| Hauteur (impériale) | 11.5 in. |
|---|---|
| Certifications/Conformité | USA: Class I, Division 1, Groups A,B,C,D T3; Canada: Class I, Zone 1, Ex db ib IIC T3 Gb; ATEX: CE0359 Ex II 2 G Ex db ib IIC T3 Gb; IECEx: Ex db ib IIC T3 Gb |
| Précision | ±10% of reading or ±1.0 ppm, whichever is greater, from 1.0 to 10,000 ppm |
| Garantie | One year from date of shipment |
| Temps de réponse | Less than 3.5 seconds for 90% of final value, using 10,000 ppm of methane |
| Fréquence | 50/60 Hz |
| Type de batterie | Lithium-ion |
| Interface série | USB |
| Profondeur (impériale) | 4 in. |
| Tension | 120 V |
| Largeur (impériale) | 9 in. |
| Reproductibilité | ±2% at 500 ppm of methane |
| Points de données | Auto mode - 1 per second to 1 per 999 minutes, user selectable; VOC or FE Mode - 2 to 30 seconds, user selectable |
| Composants mesurés | Most Organic and Inorganic Compounds |
| Débit | 1 L/min., nominal at sample probe inlet |
| Contraintes informatiques | USB port, Windows XP operating system or higher |
| Limites de détection | 0.5 ppm of methane |
| Concentration | 0 to 30,000 ppm (methane) |
| Largeur (métrique) | 22.9 cm |
| Hauteur (métrique) | 29.2 cm |
| Combustible | 99.99% H2 for FID |
| Autonomie en mode portable | Minimum 10 hours |
| Plage de températures (métrique) | -10°C to 45°C |
| Autonomie de la batterie | 10 hours at 0°C |
| Plage de températures (impériale) | 14°F to 113°F |
| Type de détecteur | Flame Ionization Detector (FID) |
| Profondeur (métrique) | 10.2 cm |
Thermo Scientific™ TVA2020 Toxic Vapor Analyzer - FID Only with Enhanced & Sampling Probes
Quickly detect organic and inorganic compounds in demanding applications such as Method 21 monitoring and site remediation.
| Hauteur (impériale) | 11.5 in. |
|---|---|
| Certifications/Conformité | USA: Class I, Division 1, Groups A,B,C,D T3; Canada: Class I, Zone 1, Ex db ib IIC T3 Gb; ATEX: CE0359 Ex II 2 G Ex db ib IIC T3 Gb; IECEx: Ex db ib IIC T3 Gb |
| Précision | ±10% of reading or ±1.0 ppm, whichever is greater, from 1.0 to 10,000 ppm |
| Garantie | One year from date of shipment |
| Temps de réponse | Less than 3.5 seconds for 90% of final value, using 10,000 ppm of methane |
| Fréquence | 50/60 Hz |
| Type de batterie | Lithium-ion |
| Interface série | USB |
| Profondeur (impériale) | 4 in. |
| Tension | 120 V |
| Largeur (impériale) | 9 in. |
| Reproductibilité | ±2% at 500 ppm of methane |
| Points de données | Auto mode - 1 per second to 1 per 999 minutes, user selectable; VOC or FE Mode - 2 to 30 seconds, user selectable |
| Composants mesurés | Most Organic and Inorganic Compounds |
| Débit | 1 L/min., nominal at sample probe inlet |
| Contraintes informatiques | USB port, Windows XP operating system or higher |
| Limites de détection | 0.5 ppm of methane |
| Concentration | 0 to 30,000 ppm (methane) |
| Largeur (métrique) | 22.9 cm |
| Hauteur (métrique) | 29.2 cm |
| Combustible | 99.99% H2 for FID |
| Autonomie en mode portable | Minimum 10 hours |
| Plage de températures (métrique) | -10°C to 45°C |
| Autonomie de la batterie | 10 hours at 0°C |
| Plage de températures (impériale) | 14°F to 113°F |
| Type de détecteur | Flame Ionization Detector (FID) |
| Profondeur (métrique) | 10.2 cm |
MilliporeSigma™ Supelco™ Replacement Parts and Accessories for MSA Tube Holders
For use with MSA Tube Holders
| À utiliser avec (équipement) | MSA Tube Holder |
|---|---|
| À utiliser avec (application) | Industrial Hygiene |
Thermo Scientific™ TruNarc™ Handheld Narcotics Analyzer
Quickly identify narcotics and controlled substances, including key drugs of abuse and emerging threats like synthetic cathinones (bath salts) and cannabinoids.
| Type de batterie | Rechargeable internal 3.7 V battery pack (10 hr.); DC wall adapter, 5 V DC, 1.5 A; optional car charger |
|---|---|
| Formats d’exportation de données | CSV, Excel™ spreadsheet, SPC file, PDF, SCN, SCZ |
| Description | Includes factory repair, loaner units when available, and 24/7 technical support. Companion PC TruNarc admin software, unlimited access to TruNarc eLearning course and free basic software updates to core narcotics library are provided for the life of the instrument. Includes TruNarc on-site instructor led training for up to 12 students within the Continental United States (CONUS) - expires 9 months after date of purchase. |
| Type de produit | Handheld Raman Spectrometer |
| Poids (impériale) | 1.25 lb. |
| Plage de températures (métrique) | -10°C to +50°C |
| Dimensions (L x l x H) | 6.4 x 4.1 x 2 in. (16.26 x 10.41 x 5.1 cm) |
| Tension | 3.7 V |
| Bibliothèques | Controlled substances, cutting agents, and precursors including: heroin, synthetic drugs on leaf materials or blotter paper |
| Langues | English, Arabic, Chinese, Czech, Dutch, French, Japanese, Polish, Russian, Spanish |
| Plage de températures (impériale) | 14°F to 122°F |
| Poids (métrique) | 0.57 kg |