UserName
Reservoir sizes from 200 to 500mL
Numéro de bouchon | 2 |
---|---|
Type | Chromatography Column |
Matériau | Borosilicate Glass |
Use for predictable HPLC separations of compounds in highly aqueous mobile phases.
For flash chromatography
Taille du joint | 24/40 |
---|
Prepacked columns for high-resolution purification of proteins and other biomolecules by ion exchange chromatography. They are well-suited for the preparation of highly pure proteins for structural studies and protein analysis.
Débit | 0.5 to 2 mL/min. |
---|---|
Forme des particules | Spherical |
Température (métrique) | 4°C to 40°C |
Matériau | Tricorn™ Glass |
pH | 2 to 12 |
Gamme de produits | Capto |
Quantité | 1 Ea. |
Granulométrie | ∼9μm |
Pression max. | 4 MPa (40 bar) |
Matériau de remplissage | Highly Cross-Linked Agarose |
Type de colonne | Ion Exchange Column |
À utiliser avec (application) | Anaylsis or Purification of Proteins and Nucleic Acids |
Offer convenient, easy to use protection for analytical HPLC columns
Longueur (métrique) | 10 mm |
---|---|
Phase stationnaire | C18 |
Use these endcapped, ultrapure, silica-based columns to generate exceptional peak shape and resolution for HPLC and LC/MS analyses using generic gradients
Achieve exceptional peak shape and resolution for your HPLC and LC/MS applications.
Phase | Reversed Phase |
---|---|
Taux de carbone | 10% |
“End-capped” | Yes |
Type d’USP | L1 |
pH | 1 to 11 |
Surface spécifique | 220 m²/g |
Granulométrie | 5 μm |
Porosité | 175 Å |
Type de colonne | Reversed Phase |
Matériau de remplissage | Silica |
Phase stationnaire | C18 |
Format de colonne | Analytical Column |
Featuring a lower hydrophobicity than C18 or C8 columns, Thermo Scientific™ Hypersil GOLD™ C4 columns provide outstanding sensitivity and high efficiency.
Phase | Reversed Phase |
---|---|
Température | 60°C |
Taux de carbone | 5% |
“End-capped” | Yes |
Type d’USP | L26 |
pH | 2 to 8 |
Surface spécifique | 220 m²/g |
Porosité | 175 Å |
Type de colonne | Reversed Phase |
Phase stationnaire | C4 |
Choose the nonpolar Thermo Scientific™ TraceGOLD™ TG-1MS GC column for optimal signal-to-noise ratio, sensitivity, and MS integrity. Achieve consistent results with this low-bleed, stable column.
Polarité | Non-Polar |
---|
Analyze common drugs of abuse with these GC columns and achieve high performance, sensitivity and reproducibility.
Longueur (métrique) | 15 m |
---|---|
Type d’USP | G42 |
Gamme de produits | TRACE |
Température max. | 360/370°C |
Phase stationnaire | Trace™ TR-DoA 35 MS |
À utiliser avec (application) | GC/MS for Amphetamines, Codeine, and Morphine |
Retain highly polar and hydrophilic analytes, which are difficult to analyze with conventional C18 columns, using Hypersil GOLD PEI HILIC LC Columns.
Phase | HILIC |
---|---|
Température | 60°C |
Taux de carbone | 6% |
“End-capped” | No |
pH | 2 to 8 |
Surface spécifique | 220 m²/g |
Porosité | 175 Å |
Type de colonne | HILIC |
Phase stationnaire | Polyethyleneimine |
Provides protection to the analytical column.
Type | GC Guard Column |
---|---|
Diamètre (métrique) interne | 0.53 mm |
Quantité | 1 |
A good choice for QA/QC labs as a robust, general-purpose column in applications where reproducibility and long column lifetimes are required
Phase | Reversed Phase |
---|---|
Taux de carbone | 11% |
“End-capped” | Yes |
Type d’USP | L1 |
Surface spécifique | 170 m²/g |
Granulométrie | 3 μm |
Porosité | 130 Å |
Type de colonne | Reversed Phase |
Phase stationnaire | C18 |
Use as a robust, general-purpose column for a wide range of applications in QC/QA labs.
Phase | Reversed Phase |
---|---|
Taux de carbone | 11% |
“End-capped” | Yes |
Type d’USP | L1 |
Surface spécifique | 170 m²/g |
Type de colonne | Reversed Phase |
Phase stationnaire | C18 |
Get the performance you need with ProPac™ 3R SAX HPLC columns. Suitable for charge variant separations and recommended for therapeutic proteins, mAbs, ADCs, and AAVs.
Phase | Strong Anion Exchange |
---|---|
Température | Ambient to 60°C |
Gamme de produits | ProPac |
pH | 2 to 12 |
Granulométrie | 3 μm |
Technique | Bio-LC |
Porosité | Nonporous |
Pression max. | 4500 psi (310 bar) |
Type de colonne | Ion Exchange |
Matériau de remplissage | Monodisperse Polymer Resin |
Phase stationnaire | Proprietary |
Format de colonne | Analytical Column |