Omegawaxâ„¢ capillary GC column may be used for herbicide determination using In-tube Solid-phase microextraction (SPME).
Capillary GC column is also known as open tubular column. The carrier gas flows through the central aperture and is unrestricted throughout the length of the column.
Polar column that is suitable for the analyses of solvents, fatty acid methyl esters (FAMEs), food, flavor and fragrance compounds, alcohols, and aromatics.
Type | Capillary GC |
---|---|
Packing Material | Poly(ethylene glycol) |
Material | Fused Silica |
For Use With (Application) | Gas Chromatography (GC) |
Film Thickness | 1 μm |
Product Line | SUPELCOWAX |
Max. Temperature | 240°C |
---|---|
Stationary Phase | Rtxâ„¢-624 |
Temperature Range | -20°C to +240°C |
Coating | Fused Silica |
For Use With (Application) | Volatile Organic Pollutants Analysis |
USP Type | G43 |
Separate ethane, ethylene and acetylene consistently with the intermediate polarity PLOT column with essentially no particle release.
Max. Temperature | Up to 250°C |
---|---|
Stationary Phase | TracePLOTâ„¢ TG-BOND Q+ |
Polarity | Mid-Polar |
For Use With (Application) | GC for the Separation of Ethane, Ethylene, and Acetylene to Baseline |
Use Thermo Scientificâ„¢ TracePLOT TG-BOND Alumina GC Columns for linear and quantitative analysis of polar unsaturated hydrocarbons.
Max. Temperature | Up to 200°C |
---|---|
Stationary Phase | TracePLOTâ„¢ TG-BOND Alumina |
For Use With (Application) | Polar Unsaturated Hydrocarbons Analysis,GC for Unsaturated Hydrocarbon Isomers,Linear and Quantitative Analysis of Polar Unsaturated Hydrocarbons |
Analyze toxic dioxins and furan congeners with unsurpassed performance and reproducibility.
Stationary Phase | TraceGOLD TG-Dioxin |
---|---|
Description | TG-Dioxin GC Columns |
Product Line | TraceGOLD |
Utilizes a chemically altered tubing surface to reduce peak tailing and eliminates the need for column priming when analysing amines and other basic compounds.
Max. Temperature | 220°C |
---|---|
Stationary Phase | TraceGOLDâ„¢ TG-35 MS Amine |
Polarity | Mid-Polar |
For Use With (Application) | GC/MS Amines Including Alkylamines, Diamines, Triamines and Ethanolamines,GC/MS for Nitrogen-Containing Heterocyclics |
Employ the most widely used MS phase in gas chromatography with the Thermo Scientificâ„¢ TraceGOLDâ„¢ TG-1MS GC Column.
Protect your analytical column from damage and contamination from nonvolatile materials.
Redefine your expectations for high-polarity GC columns with the Thermo Scientific TraceGold TG-POLAR Columns
Max. Temperature | 260/275°C |
---|---|
Stationary Phase | TraceGOLDâ„¢ TG-Polar |
Polarity | Highly Polar |
USP Type | G8, G48 |
Resolve compounds that phenyl and cyano phases cannot using a low-bleed GC column with an exceptionally inert phase.
Max. Temperature | 320/340°C |
---|---|
Stationary Phase | TraceGOLDâ„¢ TG-200 MS |
Polarity | Mid-Polar |
USP Type | G6 |
Use this non-polar GC column for method development and analysis of chlorinated and nitroaromatic compounds and environmental samples.
Stationary Phase | TR-1 |
---|
Use this low bleed nonpolar column for GC/MS environmental analyses that require high temperature and an inert phase.
Max. Temperature | 340/360°C |
---|---|
Stationary Phase | Traceâ„¢ TR-1 MS |
Polarity | Non-Polar |
USP Type | G1, G2, G38 |
Product Line | TRACE |
Porous-layer open-tubular (PLOT) columns are a powerful tool used in gas chromatography for analysis of fixed gases, light hydrocarbons and volatile solvents. They are mostly preferred over traditional columns.