Conductivity and TDS Standards
- (213)
- (13)
- (15)
- (1)
- (1)
- (18)
- (3)
- (109)
- (10)
- (15)
- (1)
- (33)
- (9)
- (28)
- (4)
- (1)
- (3)
- (2)
- (8)
- (3)
- (3)
- (3)
- (3)
- (3)
- (18)
- (29)
Résultats de la recherche filtrée
Traceable™ Conductivity Calibration Standards Certified Reference Material (CRM), NIST tested, Fisherbrand™
Use NIST-traceable reference materials for the highest accuracy available. Traceable™ Conductivity Calibration Standards Certified Reference Material (CRM) offer easy calibration with included instructions and temperature chart.
| Couleur | Clear |
|---|---|
| Certifications/Conformité | ISO 17034 |
| Type | Conductivity Standard |
| Nom chimique ou matériau | Conductivity Standard |
| À utiliser avec (équipement) | Conductivity Meter |
| Conditionnement | Bottle |
| Solubilité | Soluble in water |
| Type de solution | Calibration Solution |
| Technique | Calibration of Conductivity Instrument |
Traceable™ One-Shot™ Conductivity Calibration Standards Certified Reference Material Producer (CRM), Fisherbrand™
Ideal for lab or field applications
| Couleur | Clear |
|---|---|
| Nom chimique ou matériau | Conductivity Standard |
| À utiliser avec (équipement) | Conductivity Meter |
| Conditionnement | 6/Pk. |
| Solubilité | Soluble in water |
Traceable™ Conductivity Calibration Standards Certified Reference Material (CRM), Fisherbrand™
Use NIST-traceable reference materials for the highest accuracy available. TraceableTM Conductivity Calibration Standards Certified Reference Material (CRM) offer easy calibration with included instructions and temperature chart.
Traceable™ One-Shot Conductivity Standards, Fisherbrand™
Eliminates contamination with calibration within disposable container. Traceable™ One-Shot Conductivity Standards are 100% compatible with all conductivity meters.
| Poids moléculaire (g/mol) | 74.548 |
|---|---|
| À utiliser avec (équipement) | Conductivity Meters and Probes |
| Conditionnement | Bottle |
| ChEBI | CHEBI:32588 |
| SMILES | [Cl-].[K+] |
| Formule moléculaire | ClK |
| Couleur | Clear |
| Type | Conductivity Standard |
| Numéro MDL | MFCD00011360 |
| Nom chimique ou matériau | One-Shot Conductivity Standards |
| CAS | 7447-40-7 |
| CID PubChem | 4873 |
| Solubilité | Soluble in water |
| Quantité | 6 x 100 mL |
| Clé InChI | WCUXLLCKKVVCTQ-UHFFFAOYSA-M |
| Technique | Calibration of Conductivity Instrument |
Conductivity Standards for METTLER TOLEDO Conductivity Probes, METTLER TOLEDO™
Greener Choice
Offers one or more environmental benefits itemized in the U.S. FTC Green Guides.
Learn More
Offers one or more environmental benefits itemized in the U.S. FTC Green Guides.
Learn More
Recommended NIST traceable solutions for calibrating or verifying METTLER TOLEDO conductivity electrodes.
| Type | Conductivity Standard |
|---|---|
| À utiliser avec (équipement) | Conductivity Electrodes |
| Type de solution | Conductivity Standard |
| Température de stockage | Ambient |
Ricca VeriSpec™ KCl Conductivity Standard, Certified Reference Material
ISO 17025/17034 KCl Conductivity Standard Certified Reference Materials provide the highest level of quality assurance. A certificate of analysis providing the specified property value, uncertainty, and traceability is available with every bottle.
| Couleur | Colorless |
|---|---|
| Qualité | Certified |
| pH | Approximately 7 |
| Quantité | 500 mL |
| Type de solution | Conductivity Standard |
| Point d’ébullition | 100°C |
Thermo Scientific™ Orion™ Conductivity Standards and Solutions
Perform virtually any electrochemistry analysis with these conductivity standards and solutions. All conductivity standards are traceable to NIST™ standard reference materials.
| Couleur | Clear |
|---|---|
| Type | Conductivity Standard |
| Description | Conductivity Standard |
| Solubilité | Soluble |
| Type de solution | Standard Solution |
| Point d’ébullition | 100°C |
| Traçabilité au NIST | Yes |
| Note relative au nom | 100μS/cm (100μmho/cm) at 25°C |
|---|---|
| % min. CAS | 0.0046 |
| Point d’ébullition | 100°C |
| Forme physique | Liquid |
| Couleur | Colorless |
| Type | Conductivity Standard |
| Nom chimique ou matériau | Conductivity/TDS Standard |
| Concentration or Composition (by Analyte or Components) | 47.2ppm as NaCl |
| CAS | 7732-18-5 |
| Solubilité | Completely miscible |
| Point de fusion | 0°C |
| pH | 6.7 to 7.3 |
| Informations DOT | Not Regulated by DOT |
| Type de solution | Conductivity Standard |
| Durée de conservation | 24 months |
| % max. CAS | 0.0048 |
Conductivity Solution, Oakton™
Use this conductivity solution for accurate test results in the field or lab. Oakton™ Conductivity Solutions have KCl, NaCl and 442 conversions printed on the bottle for ease of use.
| Couleur | Clear |
|---|---|
| Type | Conductivity Standard |
| Nom chimique ou matériau | Cole-Parmer Conductivity Standards |
| À utiliser avec (équipement) | Conductivity Meter |
| Conditionnement | Bottle |
| Solubilité | Soluble |
| pH | 4.7 to 7.8 |
| Quantité | 500 mL |
| Type de solution | Conductivity Standard |
| Technique | Calibration of Conductivity Instrument |
| Point d’ébullition | 100°C (212°F) |
Conductivity and TDS Standard, Oakton™
CAS: 7447-40-7 Formule moléculaire: ClK Poids moléculaire (g/mol): 74.548 Numéro MDL: MFCD00011360 Clé InChI: WCUXLLCKKVVCTQ-UHFFFAOYSA-M CID PubChem: 4873 ChEBI: CHEBI:32588 Nom IUPAC: potassium;chloride SMILES: [Cl-].[K+]
| Poids moléculaire (g/mol) | 74.548 |
|---|---|
| Numéro MDL | MFCD00011360 |
| CAS | 7447-40-7 |
| CID PubChem | 4873 |
| ChEBI | CHEBI:32588 |
| Nom IUPAC | potassium;chloride |
| Clé InChI | WCUXLLCKKVVCTQ-UHFFFAOYSA-M |
| SMILES | [Cl-].[K+] |
| Formule moléculaire | ClK |
Conductivity Solution Standard, Hanna Instruments
A storage solution prepared with reagent grade chemicals that can be used to ensure optimum performance of your pH and ORP electrodes.
Thermo Scientific™ Orion™ Conductivity Conditioning Solution; 5 x 60 mL bottles
Perform virtually any electrochemistry analysis with these conductivity standards and solutions. All conductivity standards are traceable to NIST™ standard reference materials.
Conductivity Standard - 25 μmhos/cm, MilliporeSigma™ Supelco™
This Certified Reference Material (CRM) is produced and certified in accordance with ISO 17034 and ISO/IEC 17025. All information regarding the use of this CRM can be found on the certificate of analysis.
| Couleur | Colorless |
|---|---|
| Type | Conductivity Standard |
| Nom chimique ou matériau | Conductivity Standard |
| Odeur | Odorless |
| pH | 6.7 to 7.3 |
| Type de solution | Conductivity Standard |
| Point d’ébullition | 100°C |
| Forme physique | Liquid |