Direct PCR Reagents and Kits

Direct PCR Reagents and Kits
- (3)
- (11)
- (3)
- (21)
- (13)
- (5)
- (2)
- (8)
- (1)
- (2)
- (2)
- (15)
- (6)
- (1)
- (1)
- (7)
- (1)
- (4)
- (3)
- (14)
- (1)
- (1)
- (23)
- (4)
- (9)
- (3)
- (22)
- (11)
- (12)
- (32)
- (2)
- (6)
- (6)
- (19)
- (12)
- (2)
- (1)

Thermo Scientific™ Phire Plant Direct PCR Master Mix
Thermo Scientific Phire Plant Direct PCR Master Mix is designed to amplify DNA directly from plant samples.
Shipping Condition | Wet or Dry Ice |
---|---|
Polymerase | Phire Hot Start II DNA Polymerase |
GC-Rich PCR Performance | Medium |
Reaction Format | SuperMix or Master Mix |
Product Type | Direct PCR Master Mix |
Sample Type | Plant |
Reaction Speed | Fast |
Hot Start | Built-In Hot Start |
Overhang | Blunt |
Concentration | 2X |
Starting Material | DNA |
For Use With (Application) | Genotyping,Hot-start PCR |
PCR Method | Direct PCR |
Invitrogen™ SYBR™ Green Fast Advanced Cells-to-CT™ Kit
Greener Choice
Offers one or more environmental benefits itemized in the U.S. FTC “Green Guides.”
Learn More

Offers one or more environmental benefits itemized in the U.S. FTC “Green Guides.”
Learn More
The SYBR Green Fast Advanced Cells-to-Ct Kit is a complete cell lysate system designed for gene expression analysis directly from cultured cells without RNA purification.
Shipping Condition | Dry Ice |
---|---|
GC-Rich PCR Performance | High |
Fidelity (vs. Taq) | 2X |
Green Features | Fewer resources used and less waste, Less hazardous |
Concentration | 2X |
For Use With (Application) | Gene Expression |
High-throughput Compatibility | High-throughput Compatible |
PCR Method | 2-step RT-qPCR |
Detection Method | SYBR |
Format | Tube |
Product Type | Fast Advanced Cells-to-Ct Kit |
Sample Type | Mammalian Cells |
Reaction Speed | 7 min. |
Reagent Type | Cell Lysis |
Purification Target | Lysate |
Starting Material | 10-100,000 Cells |
Product Line | Cells-to-CT™ |
Thermo Scientific™ Phire Plant Direct PCR Kit (without sampling tools)
Thermo Scientific Phire Plant Direct PCR Kit is designed to amplify DNA directly from plant samples. No DNA purification is required prior to PCR.
Thermo Scientific™ Phire Tissue Direct PCR Master Mix
Thermo Scientific Phire Tissue Direct PCR Master Mix has been developed for amplification of DNA directly from a wide variety of tissues obtained from mice, human, fish, birds and insects.
Shipping Condition | Wet or Dry Ice |
---|---|
GC-Rich PCR Performance | Medium |
Includes Label or Dye | Yes |
Overhang | Blunt |
Concentration | 2X |
For Use With (Application) | Genotyping,Hot-start PCR |
PCR Method | Direct PCR |
Polymerase | Phire Hot Start II DNA Polymerase |
Reaction Format | SuperMix or Master Mix |
Product Type | Direct PCR Master Mix |
Sample Type | Tissue |
Reaction Speed | Fast |
Hot Start | Built-In Hot Start |
Starting Material | DNA |
Applied Biosystems™ SequalPrep™ Normalization Plate Kit, 96-well
SequalPrep™ Normalization Plate Kit, 96-well
Invitrogen™ CellsDirect Resuspension & Lysis Buffers includes 10 ml Resuspension Buffer & 1 ml Lysis Buffer
These two buffers are to be used only as a complement to the SuperScript™ III Platinum™ CellsDirect Kits when large number of samples are processed.
Invitrogen™ TaqMan™ Cells-to-CT™ Express Lysis Reagents
Greener Choice
Offers one or more environmental benefits itemized in the U.S. FTC “Green Guides.”
Learn More

Offers one or more environmental benefits itemized in the U.S. FTC “Green Guides.”
Learn More
This TaqMan Cells-to-CT Express Lysis Reagents product is a convenient, large volume offering of the cell lysis reagents used in our TaqMan Cells-to-CT Express Kit.
Invitrogen™ Single Cell Lysis Kit
Greener Choice
Offers one or more environmental benefits itemized in the U.S. FTC “Green Guides.”
Learn More

Offers one or more environmental benefits itemized in the U.S. FTC “Green Guides.”
Learn More
Single-cell analysis has the potential to transform life science research. However, detecting and quantitating the minute amounts of RNA contained in single cells remains a significant challenge.
Thermo Scientific™ GeneJET PCR Purification Kit
Thermo Scientific GeneJET PCR Purification Kit utilizes a proprietary silica-based membrane technology in the form of a convenient spin column, eliminating the need for tedious resin manipulations or toxic phenol-chloroform extractions.
Content And Storage | For better long-term performance, it is recommended to store the purification columns at 2°C to 8°C. |
---|---|
Format | Spin Column |
Run Time | 5 min. |
High-throughput Compatibility | Not High-throughput Compatible (Manual) |
Invitrogen™ CellsDirect™ One-Step qRT-PCR Kit
The CellsDirect™ One-Step qRT-PCR Kit delivers highly sensitive and specific real-time qPCR results directly from cells, without the need for an RNA purification step.
For Use With (Equipment) | 7500 Fast System, 7500 System, BioRad iQ5, BioRad MyiQ, Corbett RotorGene, MJ Opticon, Stratagene Mx3000P, Stratagene Mx3005P, Stratagene Mx4000, BioRad iCycler iQ, Cepheid SmartCycler, MJ Chromo4, QuantStudio 3 and 5 systems, QuantStudio 6 and 7 Pro systems, QuantStudio 7 Flex system, QuantStudio 12k Flex system, QuantStudio 6 Flex system |
---|---|
Sample Type | Cells |
Reaction Speed | Fast or Standard |
Concentration | 2X |
For Use With (Application) | RT-PCR |
Product Line | CellsDirect™, Platinum™, SuperScript™ |
Detection Method | Primer-probe |
Invitrogen™ CellsDirect™ One-Step qRT-PCR Kit with ROX, for ABI 7000, 7300, 7700, and 7900(HT) instruments
The CellsDirect One-Step qRT-PCR Kit delivers highly sensitive and specific real-time qPCR results directly from cells, without the need for an RNA purification step.
For Use With (Equipment) | 7000 System, 7300 System, 7700 System, 7900HT Fast System, 7900HT System, Eppendorf™ MasterCycler™ RealPlex, QuantStudio 3 and 5 systems, QuantStudio 6 and 7 Pro systems, QuantStudio 7 Flex system, QuantStudio 12k Flex system, QuantStudio 6 Flex system |
---|---|
Sample Type | Cells |
Reaction Speed | Fast or Standard |
Concentration | 2X |
For Use With (Application) | RT-PCR |
Product Line | CellsDirect™, Platinum™, SuperScript™ |
Detection Method | Primer-probe |
Invitrogen™ TaqMan™ Cells-to-CT™ Control Kit
Greener Choice
Offers one or more environmental benefits itemized in the U.S. FTC “Green Guides.”
Learn More

Offers one or more environmental benefits itemized in the U.S. FTC “Green Guides.”
Learn More
The Invitrogen™ TaqMan™ Cells-to-CT Control Kit is designed for use with the TaqMan™ Gene Expression Cells-to-CT Kit.
Invitrogen™ TaqMan™ PreAmp Cells-to-CT™ Kit
Greener Choice
Offers one or more environmental benefits itemized in the U.S. FTC “Green Guides.”
Learn More

Offers one or more environmental benefits itemized in the U.S. FTC “Green Guides.”
Learn More
The TaqMan PreAmp Cells-to-CT Kit makes it possible to perform gene expression analysis directly from limited or small numbers of cultured cells without RNA purification.
Invitrogen™ Cells-to-CT Bulk RT Reagents
Greener Choice
Offers one or more environmental benefits itemized in the U.S. FTC “Green Guides.”
Learn More

Offers one or more environmental benefits itemized in the U.S. FTC “Green Guides.”
Learn More
Cells-to-CT Bulk RT Reagents are separately-available, large-quantity versions of the reagents used for reverse transcription in the TaqMan™ Gene Expression Cells-to-CT™ Kit (20X RT enzyme mix and 20X RT buffer).