Direct PCR Reagents and Kits
- (2)
- (11)
- (3)
- (20)
- (12)
- (5)
- (2)
- (8)
- (1)
- (2)
- (2)
- (15)
- (5)
- (1)
- (1)
- (7)
- (1)
- (2)
- (14)
- (1)
- (1)
- (22)
- (4)
- (8)
- (2)
- (20)
- (11)
- (12)
- (6)
- (18)
- (12)
- (1)
- (1)
- (25)
- (2)
- (6)
Filtered Search Results
Invitrogen™ Cells-to-CT™ 1-Step Power SYBR™ Green Kit
Greener Choice
Offers one or more environmental benefits itemized in the U.S. FTC Green Guides.
Learn More
Offers one or more environmental benefits itemized in the U.S. FTC Green Guides.
Learn More
Like other members of the Cells-to-CT™ product family, the Cells-to-CT™ 1-Step Power SYBR™ Green Kit makes it possible to perform expression analysis directly from cultured cells without RNA purification.
| GC-Rich PCR Performance | High |
|---|---|
| Format | Tube |
| Product Type | 1-Step qPCR kit |
| For Use With (Equipment) | 7500 Fast System, 7500 System, 7900HT Fast System, 7900HT System, QuantStudio™, ViiA™ 7 System, StepOnePlus™ System, StepOne™ System, Real-Time PCR Systems or Thermal Cyclers, 7500 Fast Dx System, QuantStudio 6 and 7 Pro systems, QuantStudio 7 Flex system, QuantStudio 3 and 5 systems, QuantStudio 12k Flex system, QuantStudio 6 Flex system |
| Sample Type | Mammalian Cells |
| Reaction Speed | 7 min. |
| Reagent Type | Cell Lysis |
| Green Features | Fewer resources used and less waste, less hazardous |
| Starting Material | 10-100,000 Cells |
| For Use With (Application) | Gene Expression |
| PCR Method | 1-step RT-qPCR |
| Product Line | Cells-to-CT™, Power SYBR™ Green |
| Detection Method | SYBR |
Applied Biosystems™ CLA IdentiFiler™ Direct PCR Amplification Kit
The CLA (Cell Line Authentication) IdentiFiler Direct PCR Amplification Kit simplifies the amplification step during authentication of cell lines.
Invitrogen™ GeneArt™ CRISPR Nuclease Vector with CD4 Enrichment Kit (with competent cells)
Simple, ready-to-use, all-in-one expression vector system for CRISPR-based genome editing.
Invitrogen™ GeneArt™ Genomic Cleavage Detection Kit
The GeneArt Genomic Cleavage Detection Kit provides a simple, reliable, and rapid method for the detection of locus-specific double-strand break formation.
Invitrogen™ Cells-to-CT™ 1-Step TaqMan™ Kit
Greener Choice
Offers one or more environmental benefits itemized in the U.S. FTC Green Guides.
Learn More
Offers one or more environmental benefits itemized in the U.S. FTC Green Guides.
Learn More
Like other members of the Cells-to-CT™ product family, the Cells-to-CT™ 1-Step TaqMan™ Kit makes it possible to perform expression analysis directly from cultured cells without RNA purification.
| GC-Rich PCR Performance | High |
|---|---|
| Format | Tube |
| Product Type | 1-Step qPCR kit |
| For Use With (Equipment) | 7500 Fast System, 7500 System, 7900HT Fast System, 7900HT System, QuantStudio™, ViiA™ 7 System, StepOnePlus™ System, StepOne™ System, Real-Time PCR Systems or Thermal Cyclers, 7500 Fast Dx System, QuantStudio 6 and 7 Pro systems, QuantStudio 7 Flex system, QuantStudio 3 and 5 systems, QuantStudio 12k Flex system, QuantStudio 6 Flex system |
| Sample Type | Mammalian Cells |
| Reaction Speed | 7 min. |
| Reagent Type | Cell Lysis |
| Green Features | Fewer resources used and less waste, Less hazardous |
| Starting Material | 10-100,000 Cells |
| For Use With (Application) | Gene Expression |
| PCR Method | 1-step RT-qPCR |
| Product Line | Cells-to-CT, TaqMan |
| Detection Method | TaqMan |
Invitrogen™ Precision gRNA Synthesis Kit
Simple, ready-to-use, all-in-one expression vector system for CRISPR-Cas9. Transfection-ready guide RNA (gRNA) in as little as four hours.
Applied Biosystems™ SequalPrep™ Normalization Plate Kit, 96-well
SequalPrep™ Normalization Plate Kit, 96-well
Invitrogen™ TaqMan™ Cells-to-CT™ Express Kit
Greener Choice
Offers one or more environmental benefits itemized in the U.S. FTC Green Guides.
Learn More
Offers one or more environmental benefits itemized in the U.S. FTC Green Guides.
Learn More
The TaqMan Cells-to-CT Express Kit is a complete cell lysate system designed for gene expression analysis directly from cultured cells without RNA purification.
| Shipping Condition | Frozen, Dry Ice |
|---|---|
| Content And Storage | Express Lysis Solution (room temperature or 4°C), Express ezDNase (-20°C), SuperScript IV VILO Master Mix (-20°C), SuperScript IV VILO No RT Control (-20°C), TaqMan Fast Advanced Master Mix (4°C) |
| Isolation Technology | Direct cell lysis |
| Kit Type | Direct Cell Lysis RT-qPCR |
| Green Features | REACH compliant, less waste |
| For Use With (Application) | Gene Expression |
| High-throughput Compatibility | Yes |
| PCR Method | 2-step RT-qPCR |
| Detection Method | TaqMan |
| Target | cDNA |
| Format | Kit |
| Sample Type | Mammalian Cells |
| Purification Target | RNA |
| Starting Material | 10-100,000 Cells |
Applied Biosystems™ CLA GlobalFiler™ PCR Amplification Kit
The CLA (Cell Line Authentication) GlobalFiler PCR Amplification Kit simplifies the amplification step during authentication of cell lines.
Invitrogen™ SYBR™ Green Fast Advanced Cells-to-CT™ Kit
Greener Choice
Offers one or more environmental benefits itemized in the U.S. FTC Green Guides.
Learn More
Offers one or more environmental benefits itemized in the U.S. FTC Green Guides.
Learn More
The SYBR Green Fast Advanced Cells-to-Ct Kit is a complete cell lysate system designed for gene expression analysis directly from cultured cells without RNA purification.
| Shipping Condition | Dry Ice |
|---|---|
| GC-Rich PCR Performance | High |
| Fidelity (vs. Taq) | 2X |
| Green Features | Fewer resources used and less waste, Less hazardous |
| Concentration | 2X |
| For Use With (Application) | Gene Expression |
| High-throughput Compatibility | High-throughput Compatible |
| PCR Method | 2-step RT-qPCR |
| Detection Method | SYBR |
| Format | Tube |
| Product Type | Fast Advanced Cells-to-Ct Kit |
| Sample Type | Mammalian Cells |
| Reaction Speed | 7 min. |
| Reagent Type | Cell Lysis |
| Purification Target | Lysate |
| Starting Material | 10-100,000 Cells |
| Product Line | Cells-to-CT |
Invitrogen™ TaqMan™ Fast Advanced Cells-to-CT™ Kit
Greener Choice
Offers one or more environmental benefits itemized in the U.S. FTC Green Guides.
Learn More
Offers one or more environmental benefits itemized in the U.S. FTC Green Guides.
Learn More
The TaqMan Fast Advanced Cells-to-Ct Kit is a complete cell lysate system designed for gene expression analysis directly from cultured cells without RNA purification.
| Shipping Condition | Dry Ice |
|---|---|
| GC-Rich PCR Performance | High |
| Fidelity (vs. Taq) | 2X |
| Green Features | Fewer resources used, less waste, less hazardous |
| Concentration | 2X |
| For Use With (Application) | Gene Expression |
| High-throughput Compatibility | High-throughput Compatible |
| PCR Method | 2-step RT-qPCR |
| Detection Method | TaqMan |
| Format | Tube |
| Product Type | Fast Advanced Cells-to-Ct Kit |
| Sample Type | Mammalian cells |
| Reaction Speed | 7 min. |
| Reagent Type | Cell Lysis |
| Purification Target | Lysate |
| Starting Material | 10-100,000 Cells |
| Product Line | Cells-to-CT |
Invitrogen™ ChargeSwitch™ PCR Clean-Up Kit
ChargeSwitch PCR Clean-Up Kit is the fastest and most effective method of removing primers, unincorporated dNTPs, thermostable polymerases and salts.
| Shipping Condition | Room Temperature |
|---|---|
| Target | DNA from Enzymatic Reactions (e.g. PCR) |
| Content And Storage | The ChargeSwitch™ PCR Clean-Up Kit is shipped at room temperature. Upon receipt, store all components at room temperature. All components are guaranteed stable for 6 months when stored properly. |
| Format | Kit |
| Product Type | PCR Clean-Up Kit |
| Sample Type | PCR Products |
| Isolation Technology | ChargeSwitch™ Chemistry |
| Run Time | 5 min |
| For Use With (Application) | Next-Generation Sequencing (NGS),Cloning,Standard PCR |
| High-throughput Compatibility | High-throughput Compatible |
| Product Line | ChargeSwitch |
Invitrogen™ ChargeSwitch™-Pro PCR Clean-Up Kit
Greener Choice
Offers one or more environmental benefits itemized in the U.S. FTC Green Guides.
Learn More
Offers one or more environmental benefits itemized in the U.S. FTC Green Guides.
Learn More
The ChargeSwitch™-Pro PCR Clean-up Kit purifies high-quality DNA fragments without the use of ethanol or harsh salts known to interfere with enzymatic reactions.
| Shipping Condition | Room Temperature |
|---|---|
| Target | DNA from Enzymatic Reactions (e.g. PCR) |
| Content And Storage | The ChargeSwitch™-Pro PCR Clean-up Kit contains columns, collection tubes, recovery tubes, binding buffer, wash buffer, and elution buffer. |
| Format | Kit |
| Product Type | PCR Clean-Up Kit |
| Sample Type | PCR Products |
| Isolation Technology | ChargeSwitch™ Chemistry |
| Green Features | Fewer resources used and less waste, Less hazardous |
| For Use With (Application) | Next-Generation Sequencing (NGS),Cloning,Standard PCR |
| High-throughput Compatibility | Not High-throughput Compatible (Manual) |
| Product Line | ChargeSwitch |
Invitrogen™ TaqMan™ Gene Expression Cells-to-CT™ Kit
Greener Choice
Offers one or more environmental benefits itemized in the U.S. FTC Green Guides.
Learn More
Offers one or more environmental benefits itemized in the U.S. FTC Green Guides.
Learn More
The TaqMan™ Gene Expression Cells-to-CT™ Kit makes it possible to perform expression analysis directly from cultured cells without RNA purification.
| Shipping Condition | Dry Ice |
|---|---|
| GC-Rich PCR Performance | High |
| Purity or Quality Grade | UP (Ultra Pure) |
| Reverse Transcriptase | M-MLV |
| Green Features | Fewer resources used and less waste, Less hazardous |
| PCR Method | 2-step RT-qPCR |
| Detection Method | Primer-probe |
| Polymerase | DNA Polymerase |
| Format | Tube |
| Product Type | Gene Expression Cells-to-C Kit |
| Passive Reference Dye | ROX (Pre-mixed) |
| For Use With (Equipment) | 7000 System, 7300 System, 7500 System, 7900HT System, Applied Biosystems StepOnePlus™ Fast Real-Time PCR System, StepOne™, Standard Mode, StepOnePlus™, Standard Mode, QuantStudio 6 and 7 Pro systems, QuantStudio 7 Flex system, QuantStudio 3 and 5 systems, QuantStudio 12k Flex system, QuantStudio 6 Flex system |
| Sample Type | Cell |
| Reaction Speed | Standard |
| Product Line | Ambion, Cells-to-CT, TaqMan |