Western Blot and Nucleic Acid Membranes and Filter Paper
- (1)
- (22)
- (69)
- (19)
- (109)
- (33)
- (6)
- (74)
- (12)
- (7)
- (144)
- (1)
- (1)
- (18)
- (10)
- (5)
- (9)
- (6)
- (14)
- (15)
- (42)
- (9)
- (9)
- (6)
- (3)
- (4)
- (71)
- (5)
- (10)
- (1)
- (16)
- (1)
- (1)
- (1)
- (1)
- (2)
- (3)
- (4)
- (3)
- (1)
- (20)
- (2)
- (1)
- (2)
- (27)
- (1)
- (2)
- (2)
- (2)
- (30)
- (2)
- (15)
- (1)
- (1)
- (1)
- (2)
- (1)
- (1)
- (2)
- (2)
- (7)
- (2)
- (32)
- (7)
- (6)
- (7)
- (1)
- (12)
- (1)
- (12)
- (4)
- (1)
- (2)
- (1)
- (4)
- (6)
- (16)
- (1)
- (2)
- (20)
- (2)
- (3)
- (28)
- (1)
- (1)
- (2)
- (4)
- (2)
- (1)
- (2)
- (21)
- (1)
- (21)
- (1)
- (2)
- (4)
- (8)
- (34)
- (6)
- (5)
- (1)
- (6)
Filtered Search Results
| Pore Size | 0.45 μm |
|---|---|
| Material | PVDF |
Cytiva Amersham™ Protran™ NC Nitrocellulose Membranes: Rolls
Use this versatile nitrocellulose membrane for excellent binding affinity for small proteins and peptides, as well as nucleic acids. Cytiva Amersham™ Protran™ NC Nitrocellulose Membranes: Rolls offer excellent sensitivity, resolution, and low background.
| Format | Roll |
|---|---|
| Length (Metric) | 4 m |
| Material | 100% Pure Nitrocellulose |
| For Use With (Application) | Western blots, dot-blot assays, and other protein or nucleic acid methods |
Cytiva Amersham™ Protran™ Premium NC Nitrocellulose Membranes: Rolls
Use for the best results with fluorescence Western blotting detection applications. Cytiva Life Sciences™ Amersham™ Protran™ Premium NC Nitrocellulose Membranes: Rolls offer excellent sensitivity, resolution, and low background.
| Format | Roll |
|---|---|
| Length (Metric) | 4 m |
| Material | 100% Pure Nitrocellulose |
| For Use With (Application) | Western blots, dot-blot assays, and other protein or nucleic acid methods |
Cytiva Whatman™ Grade GB003 Blotting Paper
Ensures that no contamination will occur during the transfer steps. Whatman™ Grade GB003 Blotting Paper eliminates sheet to sheet variations with precisely cut membrane sizes.
| Thickness | 0.8 mm |
|---|---|
| Format | Sheet |
| Grade | GB003 |
| Material | Pure Cellulose |
| For Use With (Application) | General purpose paper used as membrane gel support |
MilliporeSigma™ Immobilon™-E Transfer Membrane
Immobilon™-E provides the a PVDF blotting membrane that wets in transfer buffer or water and eliminates the need for the alcohol pre-wet step.
| Pore Size | 0.45 μm |
|---|---|
| Description | Easily wetted with water |
| Color | White |
| Material | PVDF |
| Code | IEVH |
| Surface | Plain |
Invitrogen™ Power Blotter Pre-cut Membranes and Filters, PVDF, regular size
Precut, preassembled PVDF membrane and filter paper sandwiches for midi sized gels
| Pore Size | 0.45 μm |
|---|---|
| Material | PVDF |
Invitrogen™ Power Blotter Pre-cut Membranes and Filters, PVDF mini
Precut, preassembled PVDF membrane and filter paper sandwiches for midi sized gels
| Shipping Condition | Room Temperature |
|---|---|
| Pore Size | 0.45 μm |
| Material | PVDF |
Invitrogen™ Nylon membranes, 0.45 μm pore size, 8 x 7.3 cm
Pre-cut, pre-assembled membrane/filter-paper sandwiches
Invitrogen™ iBlot™ 3 Transfer Stacks, mini, PVDF
Online Exclusive Price
Offer valid exclusively on orders placed through fishersci.com.
Offer valid exclusively on orders placed through fishersci.com.
iBlot 3 Transfer Stacks are used with iBlot 3 Western Blot Transfer Device for the transfer of proteins from an SDS-PAGE gel to a membrane support when performing western blot experiments.
| Pore Size | 0.2 μm |
|---|---|
| Format | Transfer Stack |
| Length (Metric) | 8 cm |
| Dimensions (LxW) | 8 x 8 cm (Mini) |
| Material | PVDF |
| Width (Metric) | 8 cm |
| Product Line | iBlot |
Invitrogen™ Power Blotter Select Transfer Stacks, nitrocellulose, regular size
Transfer proteins rapidly and efficiently with these ready-to-use high performance transfer stacks for Invitrogen Power Blotter.
| Shipping Condition | Room Temperature |
|---|---|
| Pore Size | 0.2 μm |
| Format | Transfer Stack |
| Length (Metric) | 13 cm |
| Dimensions (LxW) | Regular, 13 cm x 8.3 cm |
| Material | Nitrocellulose |
| Width (Metric) | 8.3 cm |
| Product Line | Power Blotter |
Thermo Scientific™ Nitrocellulose Membranes, 0.45 μm
Nitrocellulose is a popular binding matrix for western blotting because of its high affinity for proteins and compatibility with a variety of detection methods (western blotting, dot-blot assays, and other protein or nucleic acid methods).
| Shipping Condition | Room Temperature |
|---|---|
| Pore Size | 0.45 μm |
| Material | Nitrocellulose |
MilliporeSigma™ Immobilon Signal Enhancer for Immunodetection
MilliporeSigma™ Immobilon™ Signal Enhancer for Immunodetection combines signal amplification and blocking in one ready-to-use reagent. Amplifies low signal intensity Western blots without amplifying the noise
Invitrogen™ Bolt™ Western Pack A (Nitrocellulose)
A wet transfer device used exclusively with the Mini Gel Tank
Invitrogen™ iBlot™ Transfer Stack, nitrocellulose, mini
Online Exclusive Price
Offer valid exclusively on orders placed through fishersci.com.
Offer valid exclusively on orders placed through fishersci.com.
iBlot Transfer Stacks are used to transfer proteins
| Pore Size | 0.2 μm |
|---|---|
| Format | Transfer Stack |
| Length (Metric) | 8 cm |
| Dimensions (LxW) | Mini, 8 cm x 8 cm |
| Material | Nitrocellulose |
| Width (Metric) | 8 cm |
| Product Line | iBlot |
Invitrogen™ iBlot™ 3 Transfer Stacks, mini, low-fluorescence PVDF
Online Exclusive Price
Offer valid exclusively on orders placed through fishersci.com.
Offer valid exclusively on orders placed through fishersci.com.
Invitrogen Low Fluorescence PVDF Membranes exhibit exceptionally low autofluorescence across all commonly used fluorescent imaging channels. Low fluorescent background enhances signal-to-noise ratios, resulting in more sensitive, higher quality and more reliable western blot data.