The BioTek ELx405 Select is the first deep well plate washer that aspirates and dispenses into 96- and 384-well deep well and standard height microplates.
Height (Metric) | 25.4 cm |
---|---|
Depth (English) | 17 in. |
Fluid Delivery Type | One positive displacement pump |
Width (English) | 14 in. |
Temperature (English) Operating | 59°F to 86°F |
Width (Metric) | 35.6 cm |
Type | Microplate Washer |
Precision | ≤3% CV |
Depth (Metric) | 43.2 cm |
Wash Cycles | 1 to 10 |
Voltage | 100/240 V |
Humidity | 10 to 80%, noncondensing |
Soak Time | Programmable in minutes and seconds, up to 60 min. |
Amperage | <8 A |
Frequency | 50/60 Hz |
Residual Volume | ≤2 μL/well |
Weight (English) | 30 lb. |
Certifications/Compliance | CE and TUV marked. RoHS compliant. |
Temperature (Metric) Operating | 15°C to 30°C |
Height (English) | 10 in. |
Display | Backlit LCD |
Weight (Metric) | 13.5 kg |
BioTek Synergy Neo2 multi-mode microplate reader features patented Hybrid Technology, with independent optical paths that ensure excellent performance in all detection modes. For Research Use Only. Not for use in diagnostic procedures.
Height (Metric) | 41 cm |
---|---|
Depth (English) | 20.7 in. |
Width (English) | 15.4 in. |
Shaking | Linear, Orbital, Double Orbital |
Software Type | Gen5 Data Analysis Software,Gen5 Secure for 21 CFR Part 11 compliance (option) |
Absorbance Range | 230 to 999 nm, 1 nm increments |
Incubator Temperature | ±0.2°C at 37°C |
Light Source | Xenon Flash |
For Use With (Application) | HTS, biomarker, nucleic acid, protein quantification, rapid kinetics, HTRF, SNP, TR FRET, BRET, Cytokines, ELISA, FP |
Width (Metric) | 39 cm |
Dynamic Range | 0 to 4 OD |
Detector Type | Photodiode,Fluorescence/Alpha: Dual PMT or Single PMT (option) |
Accuracy | Monochromator: ±2 nm; <1% at 2.0 OD, <3% at 3.0 OD |
Dispense Volume | 5 to 1000 μL, 1 μL increments |
Product Type | Multi-Mode Microplate Reader |
Depth (Metric) | 52.5 cm |
Weight (English) | 78 lb. |
Certifications/Compliance | CE and TUV marked. RoHS compliant. |
Power Consumption | 250 W max. |
CO2 Concentration Range | 0 to 20% |
Weight (Metric) | 35 kg |
Resolution | 0.0001 OD |
Height (English) | 16.1 in. |
Cover for use with Lionheart LX
Seahorse Normalization for use with Cytation 1 and Cytation 5.
The 406 FX is a compact instrument offering fast, full plate washing along with up to six reagent dispensers. For Research Use Only.
For use with Synergy 2, Synergy MX, Synergy 4 and Synergy H4 microplate readers.
The BioTek 800 TS absorbance reader is an affordable, high-quality microplate reader for assays in 6- to 384-well formats. For Research Use Only. Not for use in diagnostic procedures.
Detector Type | Photodiode |
---|---|
Reading Options | Endpoint, Kinetic, Well-area Scanning |
Shaking | Linear (except NB configurations) |
Product Type | Microplate Reader |
Voltage | 100/240 V |
Bandwidth | 10 nm |
Software Type | Gen5 Data Analysis Software, Gen5 Secure for 21 CFR Part 11 compliance (option) |
Weight (English) | 18.5 lb. |
Certifications/Compliance | CE and TUV marked. RoHS compliant. |
For Use With (Application) | Measuring absorbance in microplate-based assays |
Light Source | Tungsten Halogen Lamp |
Interface | USB Type B, USB Type A |
Weight (Metric) | 8 kg |
The BioTek 405 LS washer has a well earned reputation as an economical plate washer that offers excellent performance and reliability.
Height (Metric) | 25.4 cm |
---|---|
Depth (English) | 17 in. |
Width (English) | 14 in. |
Width (Metric) | 35.6 cm |
Flow Rate | High to Low Flow; Optimized rates for cell assays |
Type | Microplate Washer |
Bottles | Optional (4 or 10 L) |
Washing Speed | 96-wells: 300 μL/well, 3 cycles: <30 s; 384-wells: 100 μL/well, 3 cycles: <80 s; 384-wells: 400 μL/well, 1 cycle: <20 s |
Dispense Volume | 25 to 3000 μL/well |
Precision | <3% CV: 300 μL/well (96-well washing); <4% CV: 80 μL/well (384-well washing) |
Depth (Metric) | 43.2 cm |
Wash Cycles | 1 to 250 |
Voltage | 100/240 V |
Humidity | 10 to 85%, noncondensing |
Soak Time | Programmable in minutes and seconds, up to 60 min. |
Increments | 1 μL |
Frequency | 50/60 Hz |
Residual Volume | <2 μL/well (96- and 384-well plates), 96-tube manifold for 96 wells, 192-tube for 384 wells |
Weight (English) | With internal buffer switching - 36 lb.; Without - 30 lb. |
Certifications/Compliance | CE and TUV marked. RoHS compliant. |
Height (English) | 10 in. |
Weight (Metric) | With internal buffer switching - 16.5 kg; Without - 13.5 kg |
Plate Type | 96- and 384-well, Low Profile and Standard, Solid and Filter Bottom (Pore Sizes 0.45 to 1.2 μm) Plates |
The BioTek EL406 washer dispenser is a compact instrument offering fast, full plate washing along with three reagent dispensers. For In Vitro Diagnostic Use.
Height (Metric) | 31.8 cm |
---|---|
Depth (English) | 18 in. |
Width (English) | 16.5 in. |
Width (Metric) | 42 cm |
Flow Rate | High to Low Flow; Optimized rates for cell assays |
Type | Microplate Washer/Dispenser |
Accuracy | ±3%; Dispensing: ±1 μL at 5 μL, +1 μL at 20 μL, ±1% at 100 μL |
Bottles | Optional (1 or 2 L) |
Dispense Volume | 500 nL to 3000 μL/well |
Precision | Wash: <3% CV (model dependent); Dispense (Syringe Pump): ≤5% CV at 5 μL, ≤2.5% CV at 20 μL, ≤1% CV at 100 μL |
Depth (Metric) | 46 cm |
Wash Cycles | 1 to 250 |
Voltage | 100/240 V |
Soak Time | Programmable in minutes and seconds, up to 60 min. |
Increments | 1 μL |
Frequency | 50/60 Hz |
Residual Volume | ≤2 μL/well |
Weight (English) | 32 lb. |
Certifications/Compliance | CE and TUV marked. RoHS compliant. |
Height (English) | 12.5 in. |
Weight (Metric) | 14.5 kg |
Plate Type | 96-, 384- and 1536-well; Low profile and standard height; Solid and filter bottom (option) plates |
The BioTek 50 TS washer offers excellent microplate washing performance. For In Vitro Diagnostic Use.
Wash Volume | 25 to 3000 μL/well |
---|---|
Connections | USB (1) |
Fluid Delivery Type | One positive displacement syringe drive |
Automation Interface | 4.3 in. Color LCD Touch Screen Display |
Flow Rate | 150 to 1000 μL/well/sec. (manifold dependent) |
Type | Microplate Washer |
Bottles | Optional (2 to 4 L) |
Wash Cycles | 1 to 10 |
Soak Time | Programmable in minutes and seconds, up to 30 min. |
Weight (English) | 22 lb. |
Certifications/Compliance | CE and TUV marked. RoHS compliant. |
Display | 4.3 in. LCD Color Touch Screen |
Weight (Metric) | 9.8 kg |
Plate Type | 24-, 96-, 384-well Plates (96- and 384-well: Standard and Low Profile Plates, Solid and Filter Bottom (Option), 24-well Plates with 4-well Manifold) |
For use with PowerWave HT and PowerWave XS microplate spectrophotometers.
The BioTek BioSpa live cell analysis system offers unique benefits for a wide variety of live cell imaging applications in up to 8 microplates or other labware. For In Vitro Diagnostic Use.
Height (Metric) | 48 cm |
---|---|
Depth (English) | 20.1 in. |
Width (English) | 27.2 in. |
Product Type | Automated Microplate Incubator |
Depth (Metric) | 51 cm |
Humidity | 80 to 95% |
Certifications/Compliance | CE and TUV marked. RoHS compliant. |
Width (Metric) | 69 cm |
Operating Temperature Range (Metric) | Ambient to 45°C |
Height (English) | 18.9 in. |
BioTek Cytation 1 cell imaging multi-mode reader combines fluorescence and high contrast brightfield imaging with conventional multi-mode detection. For Research Use Only. Not for use in diagnostic procedures.
Height (Metric) | 44.5 cm |
---|---|
Depth (English) | 20 in. |
Width (English) | 16.5 in. |
Shaking | Linear, Orbital, Double Orbital |
Light Source | Xenon Flash |
Width (Metric) | 41.9 cm |
Reading Options | Endpoint, kinetic, area scanning, plate mode inject/read process and well mode inject/read process |
Type | Cell Imaging Multi-Mode Microplate Reader |
Depth (Metric) | 50.8 cm |
Software | Gen5 Microplate Reader and Imager Software |
Certifications/Compliance | CE and TUV marked. RoHS compliant. |
Temperature Range (Metric) | Incubation to 45°C |
O2 Concentration Range | 0 to 19% |
CO2 Concentration Range | 0 to 20% |
Height (English) | 17.5 in. |
Resolution | 0.3 μm/pixel at 20X |
Plate Type | 6-well to 384-well plates |
The BioTek 405 TS washer has an excellent reputation in life science research for outstanding results in many applications.
Wash Volume | 25 to 3000 μL/well |
---|---|
Connections | USB (2) |
Height (Metric) | 25.4 cm |
Depth (English) | 17 in. |
Fluid Delivery Type | Internal positive displacement pump |
Automation Interface | High Resolution LED Backlit Touch Screen |
Width (English) | 14 in. |
Width (Metric) | 35.6 cm |
Type | Microplate Washer |
Bottles | Optional (4 or 10 L) |
Dispense Volume | 25 to 3000 μL/well (192-pin manifold); 50 to 3000 μL/well (96-pin manifold) |
Depth (Metric) | 43.2 cm |
Wash Cycles | 1 to 250 |
Voltage | 100/240 V |
Soak Time | Programmable in minutes and seconds, up to 60 min. |
Frequency | 50/60 Hz |
Residual Volume | ≤2 μL/well |
Weight (English) | With internal buffer switching - 36 lb.; Without - 30 lb. |
Certifications/Compliance | CE and TUV marked. RoHS compliant. |
Height (English) | 10 in. |
Display | LED |
Weight (Metric) | With internal buffer switching - 16.5 kg; Without - 13.5 kg |
Plate Type | 96- and 384-well, Low Profile and Standard, Solid and Filter Bottom (Option) Plates |
Save 25% when you purchase a qualifying Agilent BioTek Cytation C10 Confocal Imaging Reader.
Save up to 25% when you buy an Agilent BioTek MultiFlo FX Multimode Dispenser.
Agilent Cell Analysis products aim to help you improve our world with solutions that enable more effective treatments and a higher quality of life. Agilent’s diverse portfolio is designed to help you uncover unique cell biology insights, discover novel drug targets, improve preclinical toxicology, and pioneer the next generation of immunotherapies.
While cell analysis can help you understand, predict, and influence the factors that determine cell health, proliferation, function, and death, conducting investigations and compiling data sets can be complicated and taxing on your lab resources.
By choosing Agilent products, you can simplify and enhance your workflows while enabling both beginners and experts to generate meaningful results and insights.