Thermo Scientific™ Maxima Probe qPCR Master Mixes
Optimize qPCR with probe chemistry using standard cycling protocols with these ready-to-use qPCR master mixes.
Applied Biosystems™ TaqMan™ Fast Virus 1-Step Multiplex Master Mix for qPCR (No ROX)
TaqMan Fast Virus 1-Step Multiplex Master Mix (No ROX) is designed to enable dye flexibility for multiplexing up to four different RNA/DNA targets for high-throughput RT-qPCR.
| Shipping Condition | Dry Ice |
|---|---|
| InhibitorToleranceSimple | High |
| Concentration | 4X |
| For Use With (Application) | Microbial Detection,Gene Expression,DNA Quantitation,Presence/Absence |
| PCR Method | 1-step RT-qPCR |
| Multiplex Capability | Up to 4-plex |
| Detection Method | Primer-probe |
| Thermostability | Not Applicable |
| Passive Reference Dye | None |
| For Use With (Equipment) | 7500 Fast System, 7500 System, 7900HT System, QuantStudio™ 12k Flex, QuantStudio™ 3, QuantStudio™ 5, QuantStudio™ 6 Flex, QuantStudio™ 6 Pro, QuantStudio™ 7 Flex, QuantStudio™ 7 Pro, StepOne™, StepOnePlus™, ViiA™ 7 System |
| Sample Type | RNA, DNA |
| Reaction Speed | Fast or Standard |
| Target Specificity | RNA only, Both RNA and DNA |
| Hot Start | Built-In Hot Start |
Applied Biosystems™ TaqMan™ Universal PCR Master Mix, no AmpErase™ UNG
TaqMan™ Universal PCR Master Mix, No AmpErase™ UNG is the ideal reagent solution when you need a Master Mix for multiple 5' nuclease DNA applications.
| Shipping Condition | Wet Ice |
|---|---|
| Polymerase | AmpliTaq Gold DNA Polymerase |
| GC-Rich PCR Performance | High |
| Product Type | Universal PCR Master Mix |
| Passive Reference Dye | ROX (Pre-mixed) |
| For Use With (Equipment) | 7000 System, 7300 System, 7500 System, 7700 System, 7900HT System,Applied Biosystems StepOnePlus™ Fast Real-Time PCR System, GeneAmp 9600, StepOne™, Standard Mode, StepOnePlus™, Standard Mode |
| Sample Type | DNA (Genomic), cDNA |
| Reaction Speed | Standard |
| For Use With (Application) | Gene Expression,Genotyping,miRNA analysis |
| PCR Method | qPCR |
| Product Line | TaqMan™ |
| Detection Method | Primer-probe |
Applied Biosystems™ TaqMan™ Fast Universal PCR Master Mix (2X), no AmpErase™ UNG
TaqMan™ Fast Universal PCR Master Mix contains all of the components, excluding the template and primers, for superior real-time qPCR.
| GC-Rich PCR Performance | High |
|---|---|
| Fidelity (vs. Taq) | 2 X |
| Concentration | 2X |
| For Use With (Application) | Gene Expression,Genotyping,miRNA analysis |
| PCR Method | qPCR |
| Detection Method | Primer-probe |
| Polymerase | AmpliTaq DNA Polymerase |
| Format | Tube |
| Product Type | Fast Universal PCR Master Mix |
| Passive Reference Dye | ROX (Pre-mixed) |
| For Use With (Equipment) | 7500 Fast System, 7900HT Fast System, StepOne™, Fast Mode, StepOnePlus™, Fast Mode |
| Sample Type | DNA (Genomic), cDNA |
| Reaction Speed | Fast |
| Product Line | AmpErase™, TaqMan™ |
Applied Biosystems™ TaqMan™ Gene Expression Master Mix
Precise and reliable real-time qPCR quantification over 9 logs of linear dynamic range with Applied Biosystems™ TaqMan™ Gene Expression Master Mix.
| Polymerase | AmpliTaq Gold DNA Polymerase |
|---|---|
| Purity or Quality Grade | UP (Ultra Pure) |
| Passive Reference Dye | ROX (Pre-mixed) |
| For Use With (Equipment) | 7000 System, 7300 System, 7500 System, 7900HT System, Applied Biosystems StepOnePlus™ Fast Real-Time PCR SystemStepOne™, Standard Mode, StepOnePlus™, Standard Mode |
| Sample Type | DNA (Genomic), cDNA |
| Reaction Speed | Standard |
| For Use With (Application) | Gene Expression |
| PCR Method | qPCR |
| Product Line | TaqMan™ |
| Detection Method | Primer-probe |
Applied Biosystems™ SYBR™ Green Universal Master Mix
Everything needed for SYBR™ Green dye-based PCR amplification and detection in a convenient, single-tube format.
| Polymerase | AmpliTaq Gold DNA Polymerase |
|---|---|
| GC-Rich PCR Performance | High |
| Format | Tube |
| Product Type | Real Time PCR SYBR Master Mix |
| Passive Reference Dye | ROX (Pre-mixed) |
| Reaction Speed | Standard |
| Label or Dye | SYBR Green |
| Concentration | 2X |
| For Use With (Application) | Gene Expression |
| PCR Method | qPCR |
| Product Line | SYBR™ |
| Detection Method | SYBR |
Applied Biosystems™ TaqMan™ Genotyping Master Mix
Optimized for end-point fluorescence detection in SNP genotyping applications.
| GC-Rich PCR Performance | High |
|---|---|
| Fidelity (vs. Taq) | 2 X |
| Purity or Quality Grade | UP (Ultra Pure) |
| Concentration | 2X |
| For Use With (Application) | Genotyping |
| PCR Method | qPCR |
| Detection Method | Primer-probe |
| Polymerase | AmpliTaq Gold DNA Polymerase |
| Genotyping Target | Copy Number Variants, SNPs (Unknown or Numerous), Drug Metabolizing Enzymes, SNPs (Known) |
| Product Type | Genotyping Master Mix |
| Passive Reference Dye | ROX (Pre-mixed) |
| For Use With (Equipment) | Applied Biosystems StepOnePlus™ Fast Real-Time PCR System, QuantStudio™ 12k Flex, QuantStudio™ 3, QuantStudio™ 5, QuantStudio™ 6 Flex, QuantStudio™ 7 |
| Sample Type | DNA (Genomic) |
| Reaction Speed | Standard |
| Technique | SNP Genotyping (Real-Time PCR-Based), CNV (Copy Number Variation) |
| Product Line | TaqMan™ |
Applied Biosystems™ Path-ID™ qPCR Master Mix with Manual
Ambion™ Path-ID™ qPCR Master Mix is a convenient enzyme, buffer, and dNTP mix for TaqMan™ probe-based, real-time PCR detection of DNA targets.
| Content And Storage | 2X qPCR Master Mix is stored at –20°C. Nuclease-free water may be stored at any temperature. |
|---|---|
| Purity or Quality Grade | UP (Ultra Pure) |
| Form | Liquid |
| Concentration | 2X |
| For Use With (Application) | Animal Health,Pathogen Detection |
| PCR Method | qPCR |
| Detection Method | Primer-probe |
| Polymerase | AmpliTaq Gold DNA Polymerase |
| Format | Tube |
| Product Type | qPCR Master Mix |
| Passive Reference Dye | ROX (Pre-mixed) |
| Reaction Speed | Fast or Standard |
| Hot Start | Built-In Hot Start |
| Product Line | Ambion™, Path-ID™ |
Applied Biosystems™ TaqMan™ Environmental Master Mix 2.0
Accurate, real-time PCR-based pathogen detection in the presence of high levels of inhibitors.
| Purity or Quality Grade | UP (Ultra Pure) |
|---|---|
| Concentration | 2X |
| For Use With (Application) | Gene Expression,Genotyping,Pathogen Detection,Virus Detection |
| PCR Method | qPCR |
| Detection Method | Primer-probe |
| Polymerase | AmpliTaq Gold DNA Polymerase |
| Format | Bottle |
| Product Type | qPCR Master Mix |
| Passive Reference Dye | ROX (Pre-mixed) |
| For Use With (Equipment) | 7000 System, 7300 System, 7500 Fast System, 7500 System, 7900HT Fast System, 7900HT System, StepOne™, Standard Mode |
| Sample Type | Environmental Sample, Food |
| Reaction Speed | Standard |
| Hot Start | Built-In Hot Start |
| Product Line | TaqMan™ |
Applied Biosystems™ TaqMan™ GTXpress™ Master Mix
Combines AmpliTaq™ Fast DNA Polymerase, UP, dNTPs, Tracking Dye, and ROX™ dye in a convenient single vial format.
| GC-Rich PCR Performance | High |
|---|---|
| Concentration | 2X |
| For Use With (Application) | Genotyping |
| PCR Method | qPCR |
Applied Biosystems™ MeltDoctor™ HRM Master Mix
Contains all components (excluding template and primers) formulated for superior HRM performance across a wide range of genomic targets.
| GC-Rich PCR Performance | High |
|---|---|
| Form | Liquid |
| For Use With (Application) | Genotyping |
| PCR Method | qPCR |
| Detection Method | HRM |
| Polymerase | AmpliTaq Gold 360 DNA Polymerase |
| Genotyping Target | SNPs (Unknown or Numerous), Epigenetic Targets |
| Product Type | HRM Master Mix |
| For Use With (Equipment) | 7500 Fast System, 7900HT Fast System, QuantStudio™ 12k Flex, QuantStudio™ 3, QuantStudio™ 5, QuantStudio™ 6 Flex, QuantStudio™ 7, StepOne™, StepOnePlus™, ViiA™ 7 System |
| Sample Type | DNA (Genomic), cDNA |
| Reaction Speed | Fast |
| Label or Dye | High Resolution Melting (HRM),SYTO 9 |
| Technique | HRM (High Resolution Melting) Analysis, Mutation Scanning |
| Product Line | MeltDoctor™ |
Applied Biosystems™ TaqMan™ Universal Master Mix II, with UNG
TaqMan Universal Master Mix II is a convenient mix of components (except primers, probes, template, and water) necessary to perform a real-time polymerase chain reaction (PCR).
| GC-Rich PCR Performance | High |
|---|---|
| Content And Storage | Store at 2°C to 8°C in the dark. Guaranteed minimum shelf life is 60 days (exact expiry date printed on product and CofA). |
| Fidelity (vs. Taq) | 2 X |
| Purity or Quality Grade | UP (Ultra Pure) |
| Concentration | 2X |
| For Use With (Application) | Gene Expression,Genotyping,miRNA analysis |
| PCR Method | qPCR |
| Detection Method | Primer-probe |
| Polymerase | AmpliTaq Gold DNA Polymerase |
| Product Type | Universal Master Mix II |
| Passive Reference Dye | ROX (Pre-mixed) |
| For Use With (Equipment) | 7300 System, 7500 System, 7900HT System,Applied Biosystems StepOnePlus™ Fast Real-Time PCR System, StepOne™, Standard Mode, StepOnePlus™, Standard Mode, ViiA™ 7 System |
| Sample Type | DNA (Genomic), cDNA |
| Reaction Speed | Standard |
| Product Line | TaqMan™ |
Applied Biosystems™ TaqMan™ Universal Master Mix II, no UNG
TaqMan Universal Master Mix II is a convenient mix of components (except primers, probes, template, and water) necessary to perform a real-time polymerase chain reaction (PCR).
| GC-Rich PCR Performance | High |
|---|---|
| Content And Storage | Store at 2°C to 8°C in the dark. Guaranteed minimum shelf life is 60 days (exact expiry date printed on product and CofA). |
| Fidelity (vs. Taq) | 2 X |
| Purity or Quality Grade | UP (Ultra Pure) |
| Concentration | 2X |
| For Use With (Application) | Gene Expression,Genotyping,miRNA analysis |
| PCR Method | qPCR |
| Detection Method | Primer-probe |
| Polymerase | AmpliTaq Gold DNA Polymerase |
| Product Type | Universal Master Mix II |
| Passive Reference Dye | ROX (Pre-mixed) |
| For Use With (Equipment) | 7300 System, 7500 System, 7900HT System,Applied Biosystems StepOnePlus™ Fast Real-Time PCR System, StepOne™, Standard Mode, StepOnePlus™, Standard Mode, ViiA™ 7 System |
| Sample Type | DNA (Genomic), cDNA |
| Reaction Speed | Standard |
| Product Line | TaqMan™ |
Applied Biosystems™ TaqMan™ Fast Advanced Master Mix for qPCR
TaqMan Fast Advanced Master Mix delivers accurate quantification and dependability in less time on an array of qPCR instrument platforms.
| Shipping Condition | Wet Ice |
|---|---|
| GC-Rich PCR Performance | High |
| Fidelity (vs. Taq) | 2 X |
| Form | Liquid |
| InhibitorToleranceSimple | High |
| Concentration | 2X |
| For Use With (Application) | Gene Expression,DNA Quantitation,Presence/Absence,miRNA analysis |
| PCR Method | qPCR |
| Multiplex Capability | Duplex |
| Detection Method | Primer-probe |
| Includes | dUTP, UNG/UDG |
| Thermostability | 72 hr., Assembled Reaction |
| Polymerase | AmpliTaq Fast DNA Polymerase |
| Product Type | Fast Advanced Master Mix |
| Passive Reference Dye | ROX (Pre-mixed) |
| For Use With (Equipment) | 7500 Fast System, 7500 System, 7900HT System, QuantStudio 12k Flex, QuantStudio 3, QuantStudio 5, QuantStudio 6 Flex, QuantStudio 6 Pro, QuantStudio 7 Flex, QuantStudio 7 Pro, StepOne, StepOnePlus, ViiA 7 System |
| Sample Type | DNA (Genomic), cDNA |
| Reaction Speed | Fast |
| Target Specificity | cDNA or gDNA only |
| Product Line | TaqMan™ |
Applied Biosystems™ SYBR™ Select Master Mix for CFX
A cost-effective solution for real-time PCR applications.
| GC-Rich PCR Performance | High |
|---|---|
| Purity or Quality Grade | UP (Ultra Pure) |
| Form | Liquid |
| Concentration | 2X |
| For Use With (Application) | Gene Expression |
| PCR Method | qPCR |
| Detection Method | SYBR |
| Polymerase | AmpliTaq DNA Polymerase |
| Format | Vial |
| Product Type | Real Time PCR SYBR Master Mix |
| Passive Reference Dye | ROX (Pre-mixed) |
| For Use With (Equipment) | AB 7900HT, Standard Mode, AB StepOne™, Fast Mode, AB 7500, Standard Mode, AB 7500, Fast Mode, Bio-Rad CFX96 Touch™, AB StepOnePlus™, Fast Mode, AB 7900HT, Fast Mode, AB StepOne™, Standard Mode, Bio-Rad CFX Connect™, AB 7900 HT 384-Well System, Bio-Rad CFX384 Touch™, AB StepOnePlus™, Standard Mode |
| Sample Type | DNA (Genomic), cDNA |
| Reaction Speed | Fast or Standard |
| Label or Dye | SYBR GreenER |
| Hot Start | Built-In Hot Start |
| Product Line | SYBR™ |