UserName
Thermo ScientificTM HyPURITYTM C18 HPLC Columns are available in limited dimensions. Please contact Customer Service for more details.
High quality, highly pure silica columns
Phase | Reversed Phase |
---|---|
Taux de carbone | 13% |
“End-capped” | Yes |
Type d’USP | L1 |
pH | 1 to 9 |
Surface spécifique | 200 m²/g |
Granulométrie | 5 μm |
Porosité | 190 Å |
Type de colonne | Reversed Phase |
Matériau de remplissage | Silica |
Phase stationnaire | C18 |
Use for enhanced retention of polar compounds and separation of structurally related analytes with stability at pH extremes and high temperature.
Use these endcapped, ultrapure, silica-based columns to generate exceptional peak shape and resolution for HPLC and LC/MS analyses using generic gradients
Use for superior separation of hydrophobic structural isomers.
Phase | Reversed Phase |
---|---|
Température | 60°C |
Taux de carbone | 13% |
Gamme de produits | Acclaim |
pH | 2 to 8 |
Surface spécifique | 200 m²/g |
Porosité | 200 Å |
Type de colonne | Reversed Phase |
Phase stationnaire | C30 |
Use the new Thermo Scientific™ MAbPac™ RP columns for high-performance reversed-phase (RP) HPLC and LC/MS characterization of monoclonal antibodies (mAbs), fragments, variants, antibody drug conjugates (ADCs), PEGylated proteins, and bispecific proteins.
Phase | Reversed Phase |
---|---|
Granulométrie | 4 μm |
Porosité | 1500 Å |
Pression max. | 4000 psi (275 bar) |
Thermo Scientific™ POROS™ HQ is based on a quaternized polyethyleneimine functional group yielding a high capacity, High Performance Chromatography™ resins designed for the separation and purification of biomolecules.
Thermo Scientific™ POROS™ Prepacked Weak Anion Exchange Column. POROS PI is based on a polyethyleneimine functional group yielding a high capacity, High Performance Chromatography™ resins designed for the separation and purification of biomolecules.
TSKgel HT (High Temperature) Columns for the analysis of organic-soluble polymers at temperatures up to 140°C.
Highly cross-linked polymethacrylate base material provides excellent stability in high pH buffer systems. Withstands rigorous cleaning with either acid or base, 125 Å pores allow for analysis of peptides up to 8,000 Da.
Longueur (métrique) | 15 cm |
---|---|
Matrice | C18 (octadecyl) Phase/Polymer Particle Platform |
Température | 4°C to 50°C |
Type de ligand | 1 meq/mL (Estimated Ligand Density) |
Matériau | Stainless Steel Hardware |
Granulométrie | 5 μm |
Porosité | 125 Å |
Conditions d’expédition | Shipped in 55% Acetonitrile, 45% Water |
Phase stationnaire | C18 (octadecyl) |
Solvants | 0-100% Organic Solvent |
Use TSKgel™ G2500PW for the analysis of water-soluble polymers with molecular weights of less than 3,000 Da.
Hypersil GOLD™ Peptide performance is assured by our dual quality confirmation, which is performed on both neutrals compounds as well as on a Cytochrome C digest.
À utiliser avec | LC/MS |
---|---|
Phase | Reversed Phase |
Forme des particules | 1.9 μm |
Matériau | Silica |
Type d’USP | L1 |
Surface spécifique | 220 m²/g |
Porosité | 175 Å |
Diamètre (métrique) | 2.1 mm |
Matériau de remplissage | Spherical, Fully Porous, Ultrapure Silica |
À utiliser avec (application) | Peptide |
Type | Analytical Column |
Température | 60°C |
Taux de carbone | 11% |
“End-capped” | Yes |
Gamme de produits | Hypersil GOLD |
pH | 2 to 11 |
Quantité | 1 Each |
Technique | Reversed Phase HPLC |
Type de colonne | Reversed Phase |
Column Format: Guard Column; Carbon Load: 13%; Pore Size: 150 Å; Column Phase: Reversed Phase
Learn more about your proteome, metabolome, and lipidome samples with Thermo Scientific™ μPAC™ HPLC columns.
Phase | Reversed Phase |
---|---|
Température | 60°C |
“End-capped” | Yes |
pH | 1.5 to 7 |
Interpillar Distance | 2.5 μm |
Porosité | 59% |
Pression max. | 350 bar (5076 psi) |
Pillar Diameter | 5 μm |
Type de colonne | Micro Pillar Array |
Matériau de remplissage | Silicon Chip |
Phase stationnaire | C18 |
Perform large volume (>5 μL) sample injections on capillary and nano-columns with μPAC™ Trapping Columns.