HPLC Guard Columns and Cartridges
- (30)
- (1)
- (72)
- (14)
- (1)
- (4)
- (59)
- (1)
- (119)
- (3)
- (1)
- (14)
- (3)
- (3)
- (1)
- (10)
- (2)
- (13)
- (2)
- (78)
- (3)
- (75)
- (13)
- (3)
- (3)
- (3)
- (3)
- (5)
- (4)
- (40)
- (2)
- (95)
- (3)
- (1)
- (4)
- (3)
- (57)
- (1)
- (14)
- (122)
- (3)
- (105)
- (11)
- (1)
- (7)
- (17)
- (2)
- (2)
- (10)
- (2)
- (33)
- (2)
- (6)
- (9)
- (2)
- (24)
- (3)
- (1)
- (2)
- (53)
- (2)
- (73)
- (4)
- (5)
- (4)
- (6)
- (245)
- (3)
- (2)
- (5)
- (1)
- (7)
- (2)
- (8)
- (74)
- (18)
- (4)
- (3)
- (2)
- (22)
- (10)
- (7)
- (4)
- (1)
- (35)
- (9)
- (2)
- (4)
- (1)
- (3)
- (1)
- (1)
- (1)
- (3)
- (35)
- (36)
- (6)
- (1)
- (42)
- (2)
- (3)
- (44)
- (3)
- (2)
- (22)
- (4)
Filtered Search Results
Thermo Scientific™ Hypersil GOLD™ aQ Javelin™ Guard HPLC Columns
Javelin guard columns offer convenient, easy to use protection for analytical HPLC columns
MilliporeSigma™ Supelco™ OPTI-GUARD™ C18, Biocompatible 1 mm Guard Column
OPTI-GUARD™ sets the standard for low-impact, easy to use pre-column protection.
Thermo Scientific™ BetaBasic™ 8 Guard Cartridges, 5μm Particle Size
Thermo Scientific™ BetaBasic™ 8 Guard Cartridges are available in limited dimensions. Please contact Customer Service for more details.
| Pore Size | 150Å |
|---|---|
| Particle Size | 5 μm |
| Carbon Load | 7% |
| Length (Metric) | 10 mm |
| Endcapped | Yes |
| For Use With (Equipment) | Uniguard Direct-connection and Stand Alone Holder |
| pH | 2 to 9 |
| Surface Area | 200 m2/g |
| USP Type | L7 |
| Pore Size | 140Å |
|---|---|
| Particle Size | 5 μm |
| Stationary Phase | C18 |
| Carbon Load | 11% |
| Phase | Monomeric |
| Endcapped | Yes |
| Packing Material | Silica |
| pH | 2.5 to 8 |
| Temperature (Metric) Maximum | 80°C |
| Particle Shape | Spherical |
| USP Type | L1 |
Thermo Scientific™ GuardGOLD™ Capillary Columns
Protect your analytical column from damage and contamination from nonvolatile materials.
MilliporeSigma™ Supelco™ Ascentis™ Express HILIC Guard Cartridge, 2.7 μm Particle Size
Ascentis™ Express Guard Columns provide physical (filtration) and chemical protection for costly analytical columns without compromising the very high performance of Ascentis™ Express columns.
| Pore Size | 90 Å |
|---|---|
| Particle Size | 2.7 μm |
| Type | Fused-Core HPLC Guard Cartridge |
| Phase | HILIC |
| Length (Metric) | 5 mm |
| Quantity | 3/Pk. |
| For Use With (Application) | HPLC |
| Product Line | Ascentis |
MilliporeSigma™ Supelco™ Ascentis™ Express Biphenyl Guard Column, 2.7 μm Particle Size
Ascentis™ Express 90 Å Biphenyl columns can be used for basic, acidic, or neutral compounds with alternate selectivity from C18 and is especially useful for separating peaks that elute early on C18 and other phenyl phases.
| Pore Size | 90 Å |
|---|---|
| Particle Size | 2.7 μm |
| Type | Fused-Core HPLC Guard Cartridge |
| Phase | Reversed Phase |
| Length (Metric) | 5 cm |
| Endcapped | Yes |
| Quantity | 3/Pk. |
| Material | Stainless Steel Hardware |
| For Use With (Application) | HPLC |
| Product Line | Ascentis |
MilliporeSigma™ Supelco™ SRT™-C SEC-300 Gel Filtration Guard Column, 5 μm Particle Size, Stainless Steel
The bonded phase in SRT™-C SEC columns is more polar than the hydrophilic phase used in SRT™ columns, making SRT™-C columns better suited for the gel filtration analysis of more hydrophobic bioopolymers such as membrane proteins and pegylated antibodies.
| Pore Size | 300 Å |
|---|---|
| Particle Size | 5 μm |
| Type | SEC HPLC Guard Column |
| Phase | Size Exclusion |
| Length (Metric) | 5 cm |
| pH | 2.0 to 8.5 |
| Material | Stainless Steel |
| For Use With (Application) | HPLC |
| Product Line | SRT |
TSKgel™ SuperMPHZ-N Guard Column, 3 μm Particle Size, Sold by MilliporeSigma™ Supelco™
Tosoh′s innovative multi-pore technology is now also available in 3, 4 and 6 μm TSKgel™ SuperMultiporeHZ Columns and Guard Columns.
MilliporeSigma™ Supelco™ SUPELCOGEL™ K Guard Column, 9 μm Particle Size
5 cm x 4.6 mm guard column, does not include tubing, nuts or ferrules.
MilliporeSigma™ Supelco™ SUPELCOSIL™ ABZ+Plus Supelguard Cartridge, 5 μm Particle Size
Offer both high deactivation and unique selectivity.
| Pore Size | 120 Å |
|---|---|
| Particle Size | 5 μm |
| Type | Guard Cartridge |
| Phase | Reversed Phase |
| Length (Metric) | 2 cm |
| Quantity | 2/Pk. |
| For Use With (Application) | HPLC |
| Product Line | SUPELCOSIL Supelguard |
MilliporeSigma™ Supelco™ SUPELCOSIL™ LC-1 Supelguard Cartridge, 5 μm Particle Size
Due to a mixed retention mechanism, selectivity differences for polar groups are more pronounced than on C8 and C18 columns. C1 columns require 20-30% less organic modifier to provide retention similar to C18 columns.
MilliporeSigma™ Supelco™ Ascentis™ Express C18 Guard Cartridge, 2 μm Particle Size
Ascentis™ Express Guard Columns provide physical (filtration) and chemical protection for costly analytical columns without compromising the very high performance of Ascentis™ Express columns.
MilliporeSigma™ Supelco™ Ascentis™ Express RP-Amide Guard Cartridge, 2.7 μm Particle Size
Ascentis™ Express Guard Columns provide physical (filtration) and chemical protection for costly analytical columns without compromising the very high performance of Ascentis™ Express columns.
| Pore Size | 90 Å |
|---|---|
| Particle Size | 2.7 μm |
| Type | Fused-Core HPLC Guard Cartridge |
| Phase | Reversed Phase |
| Length (Metric) | 5 mm |
| Quantity | 3/Pk. |
| For Use With (Application) | HPLC |
| Product Line | Ascentis |
MilliporeSigma™ Supelco™ SUPELCOGEL™ 8H, 8% Crosslinked HPLC Guard Column, 9 μm Particle Size
Offers excellent separation of many common samples.
