Real Time PCR Products
Filtered Search Results
Applied Biosystems™ SYBR™ Select Master Mix for CFX
A cost-effective solution for real-time PCR applications.
| GC-Rich PCR Performance | High |
|---|---|
| Purity or Quality Grade | UP (Ultra Pure) |
| Form | Liquid |
| Concentration | 2X |
| For Use With (Application) | Gene Expression |
| PCR Method | qPCR |
| Detection Method | SYBR |
| Polymerase | AmpliTaq DNA Polymerase |
| Format | Vial |
| Product Type | Real Time PCR SYBR Master Mix |
| Passive Reference Dye | ROX (Pre-mixed) |
| For Use With (Equipment) | AB 7900HT, Standard Mode, AB StepOne™, Fast Mode, AB 7500, Standard Mode, AB 7500, Fast Mode, Bio-Rad CFX96 Touch™, AB StepOnePlus™, Fast Mode, AB 7900HT, Fast Mode, AB StepOne™, Standard Mode, Bio-Rad CFX Connect™, AB 7900 HT 384-Well System, Bio-Rad CFX384 Touch™, AB StepOnePlus™, Standard Mode |
| Sample Type | DNA (Genomic), cDNA |
| Reaction Speed | Fast or Standard |
| Label or Dye | SYBR GreenER |
| Hot Start | Built-In Hot Start |
| Product Line | SYBR |
Applied Biosystems™ TaqMan™ PreAmp Master Mix (cDNA pre-amplification for qPCR)
TaqMan™ PreAmp Master Mix pre-amplifies small amounts of cDNA without introducing amplification bias to the sample.
| GC-Rich PCR Performance | High |
|---|---|
| Product Type | PreAmp Master Mix |
| For Use With (Equipment) | 7500 Fast System, 7500 System, 7900HT System, QuantStudio™ 12k Flex, QuantStudio™ 3, QuantStudio™ 5, QuantStudio™ 6 Flex, QuantStudio™ 7, StepOne™, StepOnePlus™, ViiA™ 7 System |
| Sample Type | cDNA |
| For Use With (Application) | Pre-amplification |
| PCR Method | qPCR |
| Product Line | TaqMan |
| Detection Method | Primer-probe |
Applied Biosystems™ SYBR™ Select Master Mix
Cost-effective solution for real-time PCR applications.
| GC-Rich PCR Performance | High |
|---|---|
| Content And Storage | The 2x mix contains SYBR™ GreenER™ dye, AmpliTaq™ DNA Polymerase UP, dNTPs with dUTP/dTTP blend, heat-labile UDG, ROX passive reference dye and optimized buffer components. Contains 1 X 1 mL tube, sufficient for 100, 20 μL reactions (10 μL Master Mix per reaction). Store at 2–8°C. Guaranteed minimum shelf life is 60 days (exact expiry date printed on product and CofA). See user guide for primer concentration recommendations for the StepOne and StepOnePlus systems. |
| Purity or Quality Grade | UP (Ultra Pure) |
| Form | Liquid |
| Concentration | 2X |
| For Use With (Application) | Gene Expression |
| PCR Method | qPCR |
| Detection Method | SYBR |
| Polymerase | AmpliTaq DNA Polymerase |
| Format | Vial |
| Product Type | Real Time PCR SYBR Master Mix |
| Passive Reference Dye | ROX (Pre-mixed) |
| Sample Type | DNA (Genomic), cDNA |
| Reaction Speed | Fast or Standard |
| Label or Dye | SYBR GreenER |
| Hot Start | Built-In Hot Start |
| Sufficient For | 100 Reactions of 20 μL |
| Product Line | SYBR |
VetMAX™-Gold AIV Detection Kit
The VetMAX™-Gold AIV Detection Kit (Avian Influenza Virus RNA Test Kit) is a highly sensitive, qualitative, one-step, real-time RT-PCR assay to detect Avian Influenza Virus (AIV) RNA isolated from poultry (chicken/turkey) oropharyngeal/tracheal swab samples.
Applied Biosystems™ TaqMan™ hPSC Scorecard™ Kit, Fast 96-well
TaqMan™ hPSC Scorecard™ Kit, Fast 96-well
Applied Biosystems™ TaqPath™ qPCR Master Mix, CG
TaqPath qPCR Master Mix, CG, is a 2X formulation designed for gene expression and miRNA analysis. It contains thermostable Fast DNA polymerase, uracil-N-glycosylase (UNG), dNTPs with dUTP, ROX dye (passive reference), and optimized buffer components for maximum robustness and reproducibility.
| Content And Storage | Store at 2°C to 8°C in the dark. |
|---|---|
| Form | Liquid |
| InhibitorToleranceSimple | High |
| Concentration | 2X |
| For Use With (Application) | Gene Expression,Microbial Detection,DNA Quantitation,Presence/Absence,miRNA analysis |
| PCR Method | qPCR |
| Multiplex Capability | Duplex |
| Detection Method | Primer-probe |
| Includes | dUTP, UNG/UDG |
| Thermostability | 48 hr., Assembled Reaction |
| Polymerase | Fast DNA Polymerase |
| Sensitivity | Down to 10 copies |
| Format | Bottle |
| Product Type | qPCR Master Mix |
| Passive Reference Dye | ROX (Pre-mixed) |
| For Use With (Equipment) | QuantStudio Dx, 7500 Fast Dx |
| Sample Type | cDNA, DNA |
| Reaction Speed | Fast or Standard |
| Target Specificity | cDNA or gDNA only |
| Hot Start | Built-In Hot Start |
| Product Line | TaqPath |
Applied Biosystems™ TaqMan™ Advanced miRNA Assay
Applied Biosystems TaqMan Advanced miRNA Assays enable highly sensitive and specific quantification of mature miRNAs using qPCR.
Applied Biosystems™ resDNASEQ™ Human Residual DNA Quantitation Kits
Greener Choice
Offers one or more environmental benefits itemized in the U.S. FTC Green Guides.
Learn More
Offers one or more environmental benefits itemized in the U.S. FTC Green Guides.
Learn More
The resDNASEQ Human Residual DNA Quantitation Kit is a quantitative PCR (qPCR)-based system for the detection of host cell DNA from human cell lines used as expression systems for recombinant proteins.
| No. of Reactions | 100 Reactions |
|---|---|
| Format | Kit |
| Label or Dye | FAM |
| Quantity | 100 reactions |
| Host Cell | Human DNA |
| PCR Method | qPCR |
| Product Line | resDNASEQ |
| Detection Method | Primer-probe |
Applied Biosystems™ TaqMan™ RNase P Assay, VIC™ dye/QSY™ probe
TaqMan™ RNase P Assay, VIC™ dye/QSY™ probe
Applied Biosystems™ TaqPath™ ProAmp™ Master Mix
TaqPath ProAmp Master Mix is for high-throughput genotyping and copy number variation protocols requiring uncompromising reliability and accuracy, even in the presence of inhibitors commonly found in clinical samples.
| Shipping Condition | Wet Ice |
|---|---|
| Content And Storage | Store at 2°C to 8°C in the dark. |
| InhibitorToleranceSimple | Very High |
| For Use With (Application) | Genotyping |
| PCR Method | qPCR |
| Multiplex Capability | Up to 3-plex, Up to 4-plex |
| Detection Method | Primer-probe |
| Includes | dUTP, UNG/UDG |
| Thermostability | 72 hr., Assembled Reaction |
| Polymerase | Taq DNA Polymerase |
| Product Type | qPCR Master Mix |
| Passive Reference Dye | ROX (Pre-mixed) |
| For Use With (Equipment) | 7500 Fast System, QuantStudio 12k Flex, QuantStudio 3, QuantStudio 5, QuantStudio 6 Flex, QuantStudio 7 Flex, ViiA 7 System, ViiA 7 Dx, QuantStudio Dx, StepOnePlus System, StepOne System |
| Reaction Speed | Fast or Standard |
| Target Specificity | cDNA or gDNA only |
| Product Line | TaqPath |
Applied Biosystems™ TaqPath™ ProAmp™ Multiplex Master Mix
TaqPath ProAmp Multiplex Master Mix is for higher multiplexing (up to four targets) in high-throughput genotyping and copy number variation protocols requiring uncompromising reliability and accuracy, even in the presence of inhibitors commonly found in clinical samples.
| Shipping Condition | Wet Ice |
|---|---|
| Content And Storage | Store at 2°C to 8°C in the dark. |
| InhibitorToleranceSimple | Very High |
| For Use With (Application) | Genotyping,Pharmacogenomics |
| PCR Method | qPCR |
| Multiplex Capability | Up to 4-plex |
| Detection Method | Primer-probe |
| Includes | dUTP, UNG/UDG |
| Thermostability | 72 hr., Assembled Reaction |
| Polymerase | Taq DNA Polymerase |
| Product Type | qPCR Master Mix |
| Passive Reference Dye | Mustang Purple |
| For Use With (Equipment) | QuantStudio 3 or 5, QuantStudio 6/QuantStudio 7 Flex, QuantStudio 12K Flex, QuantStudio Dx, ViiA 7 Real-Time PCR System ViiA 7 Dx, 7500 Fast, StepOne or StepOnePlus |
| Reaction Speed | Fast or Standard |
| Target Specificity | cDNA or gDNA only |
| Product Line | TaqPath |
Applied Biosystems™ TaqMan™ Arbovirus Triplex Kit (ZIKV/DENV/CHIKV), 0.2 mL
A simple solution for dengue, chikungunya, and Zika virus RNA detection: just add RNA.
Applied Biosystems™ QuantStudio™ 12K Flex OpenArray™ Vaginal Microbiota Starter Kit
The QuantStudio™ 12K Flex OpenArray™ Vaginal Microbiota Starter Kit contains two training plates and a synthetic amplification control to serve as a sample for experiments.