Real Time PCR Assays and Arrays
- (8)
- (94)
- (1)
- (3)
- (1)
- (1)
- (3)
- (9)
- (76)
- (5)
- (18)
- (3)
- (17)
- (76)
- (30)
- (52)
- (1)
- (1)
- (28)
- (1)
- (1)
- (33)
- (4)
- (1)
- (1)
Filtered Search Results
Applied Biosystems™ TaqMan™ MGB Probe
Greener Choice
Offers one or more environmental benefits itemized in the U.S. FTC Green Guides.
Learn More
Offers one or more environmental benefits itemized in the U.S. FTC Green Guides.
Learn More
Custom TaqMan probes are dual-labeled primers suitable for use in any real-time PCR application. They incorporate a 5' reporter dye and a 3' nonfluorescent quencher/minor groove binder (MGB). Choose among FAM, VIC, ABY, JUN, Cy5, TET, and NED as reporters.
| Purification Method | HPLC |
|---|---|
| Purity or Quality Grade | HPLC |
| Format | Tube |
| Internal Probe Modification | None |
| For Use With (Equipment) | 7500 System, 7500 Fast System, 7900HT System, StepOne™, StepOnePlus™, ViiA™ 7 System, QuantStudio™ 3, QuantStudio™ 5, QuantStudio™ 6 Flex, QuantStudio™ 7 Flex, QuantStudio 6 Pro, QuantStudio 7 Pro, QuantStudio™ 12k Flex, QuantStudio™ Absolute Q Digital PCR System |
| Form | Liquid |
| Green Features | Sustainable packaging |
| 3'Primer Modification | MGB-NFQ |
| For Use With (Application) | Real Time PCR (qPCR) |
| Product Line | TaqMan™ |
Applied Biosystems™ Human TBP (TATA-box binding Protein) Endogenous Control (FAM™/MGB probe, non-primer limited)
Human TBP (TATA-box binding Protein) Endogenous Control (FAM™/MGB probe, non-primer limited)
| For Use With (Application) | Gene Expression |
|---|---|
| PCR Method | 2-step RT-qPCR |
| Detection Method | Primer-probe |
Applied Biosystems™ TaqMan™ Array Human Endogenous Control
TaqMan™ Express Endogenous Control Plates use TaqMan™ probe-based chemistry and are designed for use on the suite of Applied Biosystems™ Real-Time PCR Systems.
Applied Biosystems™ Human RPLPO (Large Ribosomal Protein) Endogenous Control (FAM™/MGB probe, non-primer limited)
Human RPLPO (Large Ribosomal Protein) Endogenous Control (FAM™/MGB probe, non-primer limited)
| Shipping Condition | Room Temperature |
|---|---|
| Content And Storage | Control Primer-Probe Set(s) |
| Gene Symbol | RPLPO |
| Green Features | Sustainable packaging |
| Amplicon Size | 105 |
| Concentration | 20X |
| For Use With (Application) | Gene Expression |
| PCR Method | 2-step RT-qPCR |
| Detection Method | Primer-probe |
| Accession Number | NM_053275.3 |
| Target | RPLPO |
| Format | Tube |
| Label or Dye | FAM |
| Species | Human |
| Product Line | FAM™, TaqMan™ |
Applied Biosystems™ Human B2M (Beta-2-Microglobulin) Endogenous Control (FAM™/MGB probe, non-primer limited)
Greener Choice
Offers one or more environmental benefits itemized in the U.S. FTC Green Guides.
Learn More
Offers one or more environmental benefits itemized in the U.S. FTC Green Guides.
Learn More
Human B2M (Beta-2-Microglobulin) Endogenous Control (FAM™/MGB probe, non-primer limited)
| Shipping Condition | Room Temperature |
|---|---|
| Content And Storage | Control Primer-Probe Set(s) |
| Gene Symbol | B2M |
| Green Features | Sustainable packaging |
| Amplicon Size | 75 |
| Concentration | 20X |
| For Use With (Application) | Gene Expression |
| PCR Method | 2-step RT-qPCR |
| Detection Method | Primer-probe |
| Accession Number | NM_004048.2 |
| Target | B2M |
| Format | Tube |
| Label or Dye | FAM |
| Species | Human |
| Product Line | FAM™, TaqMan™ |
Applied Biosystems™ Mouse ACTB (Actin, Beta) Endogenous Control (VIC™/MGB probe, primer limited)
Greener Choice
Offers one or more environmental benefits itemized in the U.S. FTC Green Guides.
Learn More
Offers one or more environmental benefits itemized in the U.S. FTC Green Guides.
Learn More
Mouse ACTB (Actin, Beta) Endogenous Control (VIC™/MGB probe, primer limited)
Applied Biosystems™ TaqMan™ Array, Format 48
The Custom TaqMan™ Array Card is a 384-well microfluidic card designed to perform 384 simultaneous real-time PCR reactions without using liquid-handling robots or multichannel pipettors.
| Shipping Condition | Room Temperature |
|---|---|
| Content And Storage | 1 tube containing a 40X (S and M sizes) or 80X (L size) mix of pre-formulated assay (2 probes and 2 primers). Store at -15 to -25°C. |
| Purity or Quality Grade | RNase-Free, DNase-Free |
| Description | VIC™ - MGB probe detects Allele 1, FAM - MGB probe detects Allele 2 |
| Internal Probe Modification | VIC™ (5'), FAM (5'), MGB (Minor Groove Binder) (3') |
| Form | Frozen |
| Green Features | Sustainable packaging |
| For Use With (Application) | Genotyping |
| Target | Over 10,000 mouse assays are available |
| Purification Method | Solid Phase Extraction (SPE) |
| Format | Made to Order |
| For Use With (Equipment) | 7500 System, 7500 Fast System, 7900HT System, StepOne™, StepOnePlus™, ViiA™ 7 System, QuantStudio™ 3, QuantStudio™ 5, QuantStudio™ 6 Flex, QuantStudio™ 7 Flex, QuantStudio 6 Pro, QuantStudio 7 Pro, QuantStudio™ 12k Flex ProFlex PCR System*, VeritiPro*, SimpliAmp*, MiniAmp*, Automated Thermal Cycler* * If a thermal cycler is used for PCR amplification, the optional pre-read and the post-read must be performed separately on a real-time PCR system in order to detect and record fluorescent signals. |
| 5'Primer Modification | None |
| Label or Dye | FAM,VIC |
| 3'Primer Modification | None |
| Species | Mouse |
| Product Line | TaqMan™ |
Applied Biosystems™ TaqMan™ SNP Genotyping Assay, human
Greener Choice
Offers one or more environmental benefits itemized in the U.S. FTC Green Guides.
Learn More
Offers one or more environmental benefits itemized in the U.S. FTC Green Guides.
Learn More
5' nuclease assay to discriminate between two alleles of a specific SNP for use in genotyping studies
| For Use With (Application) | Genotyping |
|---|
Applied Biosystems™ Human Alzheimer's Array
Simply pipette a sample (pre-mixed with TaqMan™ Universal PCR Master Mix) into each sample-loading port and briefly centrifuge. Within minutes, the 384-well TaqMan™ array is ready to run on the 7900HT Fast Real-Time PCR System.
Applied Biosystems™ TaqMan™ Copy Number Assay
Greener Choice
Offers one or more environmental benefits itemized in the U.S. FTC Green Guides.
Learn More
Offers one or more environmental benefits itemized in the U.S. FTC Green Guides.
Learn More
Applied Biosystems TaqMan Copy Number Assays use gold-standard TaqMan MGB probe chemistry to evaluate the copy number of genomic DNA targets using Applied Biosystems real-time PCR instruments and software.
| Shipping Condition | Room Temperature |
|---|---|
| Content And Storage | 1 tube containing a 20X (S and M sizes) or 60X (L size) mix of pre-formulated assay (1 probe and 2 primers). Store at -15 to -25°C. |
| Purity or Quality Grade | RNase-Free, DNase-Free |
| Internal Probe Modification | FAM (5'), MGB (Minor Groove Binder) (3') |
| Form | Frozen |
| Green Features | Sustainable packaging |
| PCR Method | qPCR |
| Detection Method | Primer-probe |
| Purification Method | Solid Phase Extraction (SPE) |
| Product Type | Copy Number Assay |
| For Use With (Equipment) | 7500 System, 7500 Fast System, 7900HT System, StepOne™, StepOnePlus™, ViiA™ 7 System, QuantStudio™ 3, QuantStudio™ 5, QuantStudio™ 6 Flex, QuantStudio™ 7 Flex, QuantStudio 6 Pro, QuantStudio 7 Pro, QuantStudio™ 12k Flex, QuantStudio™ Absolute Q Digital PCR System |
| Reaction Speed | Fast |
| 5'Primer Modification | None |
| Label or Dye | FAM |
| 3'Primer Modification | None |
| Species | Human |
| Product Line | TaqMan™ |