Transfection Reagents
- (71)
- (15)
- (5)
- (62)
- (2)
- (14)
- (1)
- (31)
- (5)
- (1)
- (59)
- (9)
- (53)
- (2)
- (10)
- (28)
- (5)
- (1)
- (3)
- (57)
- (50)
- (39)
- (1)
- (1)
- (12)
- (8)
- (28)
- (58)
- (2)
- (6)
- (2)
- (2)
- (76)
- (3)
- (9)
- (6)
- (3)
- (3)
- (10)
- (2)
- (49)
- (3)
- (3)
- (6)
- (17)
- (3)
- (21)
- (1)
- (5)
- (7)
- (8)
Filtered Search Results
Invitrogen™ Neon™ NxT Electroporation System 100-μL Kit with 1-Channel Tubes
The Neon NxT Electroporation System 100-μL Kit is designed specifically for use with the Neon NxT Electroporation System.
| Volume (Metric) Sample | 100 μL |
|---|---|
| Format | Electroporation Pipette Tip |
| Product Type | Pipette Tip |
| For Use With (Equipment) | Neon™ NxT Electroporation System |
| Transfection Technique | Electroporation |
| For Use With (Application) | Transfection |
| Cell Type | Stem Cells,Primary Cells,Hard-to-Transfect Cells |
Invitrogen™ Neon™ NxT Electroporation System 10-μL Kit with 1-Channel Tubes
The Neon NxT Electroporation System 10-μL Kit is designed specifically for use with the Neon NxT Electroporation System.
| Volume (Metric) Sample | 10 μL |
|---|---|
| Format | Electroporation Pipette Tip |
| Product Type | Pipette Tip |
| For Use With (Equipment) | Neon™ NxT Electroporation System |
| Transfection Technique | Electroporation |
| For Use With (Application) | Transfection |
| Cell Type | Stem Cells,Primary Cells,Hard-to-Transfect Cells |
Invitrogen™ Lipofectamine™ MessengerMAX™ Transfection Reagent
Maximize mRNA transfection with Lipofectamine MessengerMAX Transfection Reagent. This optimized lipid-based mRNA transfection reagent enables efficient mRNA delivery with a simple and scalable protocol for a wide variety of cell lines.
| Content And Storage | Store in refrigerator (2–8°C). |
|---|---|
| Format | 6-well Plate, 12-well Plate, 24-well Plate, 48-well Plate, 96-well Plate, Flasks |
| Product Type | Transfection Reagent |
| Sample Type | mRNA |
| Serum Compatible | Yes |
| For Use With (Application) | Transfection |
| Cell Type | Established Cell Lines,Neuronal Cells,Stem Cells,Primary Cells,Hard-to-Transfect Cells |
Invitrogen™ Neon™ NxT Electroporation System 10 μL Kit with 8-Channel Tubes
The Neon NxT Electroporation System 10-μL Kit with 8-Channel Tubes is designed specifically for use with the Neon NxT Electroporation System with 8-channel pipette and pipette station.
| Volume (Metric) Sample | 10 μL |
|---|---|
| Cell Line | Stem Cell, Primary Cell, Hard-to-Transfect Cell |
| Format | Electroporation Pipette Tip |
| For Use With (Equipment) | Neon™ NxT Electroporation System |
| Transfection Technique | Electroporation |
| For Use With (Application) | Transfection |
MilliporeSigma™ Novagen™ GeneJuice™, Transfection Reagent
Enables efficient DNA transfer in both stable transient transfections of eukaryotic cells.
| Content And Storage | 2°C to 8°C |
|---|
Invitrogen™ BLOCK-iT™ Transfection Optimization Kit
BLOCK-iT™ Transfection Optimization Kit
Invitrogen™ BLOCK-iT™ Alexa Fluor™ Red Fluorescent Control
BLOCK-iT™ Alexa Fluor™ Red Fluorescent Control
Invitrogen™ Lipofectamine™ 3000 Transfection Reagent
Lipofectamine™ 3000 Transfection Reagent leverages our most advanced lipid nanoparticle technology to provide superior transfection performance with improved application outcomes and reproducible results.
| Format | 6-well Plate, 12-well Plate, 24-well Plate, 48-well Plate, 96-well Plate, Flasks |
|---|---|
| Product Type | Transfection Reagent |
| Transfection Technique | Lipid-based Transfection |
| Sample Type | Plasmid DNA,Synthetic siRNA,RNAi Plasmids (shRNA, miR) |
| Classification | Animal Origin-Free |
| Serum Compatible | Yes |
| For Use With (Application) | Transfection |
| Product Line | Lipofectamine |
| Cell Type | Established Cell Lines,Stem Cells,Primary Cells,Hard-to-Transfect Cells |
Invitrogen™ Lipofectamine™ RNAiMAX Transfection Reagent
Achieve effective RNAi transfection with Lipofectamine RNAiMAX Transfection Reagent across a wide range of cell types. This lipid-based transfection reagent is optimized for siRNA and miRNA transfection, offering high delivery efficiency and low cellular toxicity, enabling effective gene silencing.
| Shipping Condition | Approved for shipment at Room Temperature or on Wet Ice |
|---|---|
| Format | 6-well Plate, 12-well Plate, 24-well Plate, 48-well Plate, 96-well Plate, Flasks |
| Product Type | Transfection Reagent |
| Transfection Technique | Lipid-based Transfection |
| Serum Compatible | Yes |
| High-throughput Compatibility | High-throughput Compatible |
| For Use With (Application) | Transfection |
| Product Line | Lipofectamine |
| Cell Type | Established Cell Lines,Stem Cells,Primary Cells,Hard-to-Transfect Cells |
Invitrogen™ Lipofectamine™ 2000 Transfection Reagent
Versatile transfection reagent that has been shown to effectively transfect the widest variety of adherent and suspension cell lines
Invitrogen™ Lipofectamine™ LTX Reagent with PLUS™ Reagent
Lipofectamine™ LTX Reagent with PLUS™ Reagent
| Shipping Condition | Wet Ice |
|---|---|
| Format | 6-well Plate, 12-well Plate, 24-well Plate, 48-well Plate, 96-well Plate, Flasks |
| Transfection Technique | Lipid-based Transfection |
| Sample Type | Plasmid DNA,RNAi Plasmids (shRNA, miR) |
| Classification | Animal Origin-Free |
| Serum Compatible | Yes |
| High-throughput Compatibility | High-throughput Compatible |
| For Use With (Application) | Transfection |
| Product Line | Lipofectamine |
| Cell Type | Established Cell Lines,Stem Cells,Primary Cells,Hard-to-Transfect Cells |
Gibco™ Expi293™ Expression System Kit
Designed with transient expression technology for rapid and ultra high-yield protein production from mammalian cells.
MilliporeSigma™ Novagen™ 293-Free™,Core Transfection Reagent
Designed for transfection of HEK293 cells grown in suspension culture
| Content And Storage | 2°C to -8°C |
|---|---|
| Form | Liquid |
Thermo Scientific™ Jump In™ T-REx™ HEK 293 Kit
The Jump-In™ T-REx™ HEK293 Kit allows the targeted integration of genetic material into a specific pre-engineered R4 site in the Jump-In™ HEK293 cell line, to create an inducible isogenic stable cell line with less effort and in less time than traditional cell engineering methods.
Thermo Scientific™ Jump In™ T-REx™ CHO-K1 Kit
The Jump-In™ T-REx™ CHO-K1 Kit allows the targeted integration of genetic material into a specific pre-engineered R4 site in the Jump-In™ CHO-K1 cell line, to create an inducible isogenic stable cell line with less effort and in less time than traditional cell engineering methods.