HPLC Columns
- (3)
- (8)
- (2)
- (2)
- (2)
- (4)
- (76)
- (52)
- (3)
- (53)
- (1)
- (43)
- (27)
- (71)
- (1)
- (29)
- (1)
- (1)
- (2)
- (1)
- (26)
- (3)
- (1)
- (11)
- (25)
- (95)
- (1)
- (73)
- (1)
- (22)
- (1)
- (147)
- (15)
- (20)
- (184)
- (21)
Filtered Search Results
Thermo Scientific™ Acclaim™ C30 HPLC Columns
Use for superior separation of hydrophobic structural isomers.
| Pore Size | 200 Å |
|---|---|
| Carbon Load | 13% |
| Stationary Phase | C30 |
| Temperature | 60°C |
| Phase | Reversed Phase |
| Column Type | Reversed Phase |
| pH | 2 to 8 |
| Surface Area | 200 m²/g |
| Product Line | Acclaim |
Thermo Scientific™ Acclaim™ Carbamate HPLC Columns
Achieve baseline separation of carbamate specified in U.S. EPA Method 531.2 with high-efficiency Thermo Scientific™ Acclaim™ Carbamate LC Columns.
| Pore Size | 120 Å |
|---|---|
| Stationary Phase | Proprietary |
| Temperature | 60°C |
| Endcapped | Yes |
| Column Type | Specialty/Application Specific |
| pH | 3 to 7 |
| Surface Area | 300 m²/g |
| Product Line | Acclaim |
Thermo Scientific™ Acclaim™ 120 C18 Columns
Use these high-efficiency reversed phase C18 columns for maximum resolution in a wide variety of applications.
| Pore Size | 120 Å |
|---|---|
| Carbon Load | 18% |
| Stationary Phase | C18 |
| Temperature | 60°C |
| Endcapped | Yes |
| Column Type | Reversed Phase |
| pH | 2 to 8 |
| Surface Area | 300 m²/g |
| USP Type | L1 |
Thermo Scientific™ Acclaim™ Surfactant HPLC Columns
Use for outstanding separation of anionic, nonionic, and cationic surfactants with ELSD and RI detectors.
| Pore Size | 120 Å |
|---|---|
| Carbon Load | 12% |
| Stationary Phase | Proprietary |
| Temperature | 60°C |
| Endcapped | Yes |
| Column Type | Specialty/Application Specific |
| pH | 2.5 to 7.5 |
| Green Features | Responsibly packaged |
| Surface Area | 300 m²/g |
| Product Line | Acclaim |
Thermo Scientific™ Acclaim™ Trinity Q1 LC Columns
Use to separate the herbicides diquat and paraquat.
Thermo Scientific™ Acclaim™ Polar Advantage HPLC Columns
Use for reversed-phase separation of basic or pharmaceutical compounds using highly aqueous mobile phases.
| Pore Size | 120 Å |
|---|---|
| Carbon Load | 17% |
| Stationary Phase | Polar Embedded |
| Temperature | 60°C |
| Endcapped | Yes |
| Column Type | Reversed Phase |
| pH | 2 to 8 |
| Surface Area | 300 m²/g |
| USP Type | L60 |
Thermo Scientific™ Acclaim™ Phenyl-1 HPLC Columns
Use for high-resolution analysis of aromatic analytes, including glucocorticosteroids, estrogens, fat-soluble vitamins, and phospholipids.
| Pore Size | 120 Å |
|---|---|
| Carbon Load | 13% |
| Temperature | 60°C |
| Phase | Reversed Phase |
| Endcapped | Yes |
| Packing Material | Spherical, Fully Porous, Ultrapure Silica |
| Column Type | Reversed Phase |
| pH | 2 to 8 |
| Surface Area | 300 m²/g |
| USP Type | L11 |
Thermo Scientific™ Acclaim™ AmG C18 HPLC Columns
Meet today’s demands for aminoglycoside antibiotic analyses, including drug purity characterization & quantification. They have unique tolerance to harsh conditions.
| Pore Size | 120 Å |
|---|---|
| Particle Size | 3 μm |
| Stationary Phase | C18 |
| Temperature | <80°C |
| Phase | Reversed Phase |
| Packing Material | Spherical, High Purity Silica |
| Column Type | Aminoglycoside Analysis |
| pH | 0.5 to 10 |
| Green Features | Responsibly packaged |
| Max. Pressure | 8000 psi (550 bar) |
| Product Line | Acclaim |
| USP Type | L1 |
Thermo Scientific™ Acclaim™ Trinity P2 HPLC Columns
Use these mixed-mode columns for separation of multivalent cations or anions and pharmaceuticals.
| Pore Size | 300 Å |
|---|---|
| Solvents | Compatible with most common HPLC organic solvents except for alcohols |
| Stationary Phase | Spherical, Nanopolymer Hybrid Silica |
| Temperature | 45°C |
| Phase | HILIC and Ion Exchange |
| Endcapped | Proprietary |
| Column Type | Mixed Mode |
| Green Features | Responsibly packaged |
| Surface Area | 100 m²/g |
| Max. Pressure | 6000 psi (415 bar) |
| Particle Size | 3 μm |
| Mobile Phase Compatibility | 0 to 100% aqueous mobile phase |
| pH | 2.5 to 7 |
| Particle Shape | Spherical silica |
| Product Line | Acclaim |
Thermo Scientific™ Acclaim™ Explosives E2 HPLC Columns
Use for baseline resolution of all 14 explosives listed in EPA Method 531.2.
| Pore Size | 120 Å |
|---|---|
| Stationary Phase | Proprietary |
| Temperature | 50°C |
| Phase | Reversed Phase |
| For Use With | LC/MS |
| Endcapped | Yes |
| Column Type | Specialty/Application Specific |
| pH | 2.5 to 7.5 |
| Green Features | Responsibly packaged |
| Surface Area | 300 m²/g |
| Product Line | Acclaim |
Thermo Scientific™ Acclaim™ 120 C8 HPLC Columns
Achieve exceptional performance and maximum resolution for reversed-phase separation of analytes with moderate hydrophobicity.
| Pore Size | 120 Å |
|---|---|
| Carbon Load | 11% |
| Stationary Phase | C8 |
| Temperature | 60°C |
| Phase | Reversed Phase |
| Endcapped | Yes |
| Column Type | Reversed Phase |
| pH | 2 to 8 |
| Surface Area | 300 m²/g |
| USP Type | L7 |
Thermo Scientific™ Acclaim™ Organic Acid HPLC Columns
Use for separation of hydrophilic, aliphatic, and aromatic organic acids.
| Pore Size | 120 Å |
|---|---|
| Carbon Load | 17% |
| Stationary Phase | Proprietary |
| Temperature | 60°C |
| Phase | Reversed Phase |
| Endcapped | Yes |
| Column Type | Specialty/Application Specific |
| pH | 2 to 8 |
| Green Features | Responsibly packaged |
| Surface Area | 300 m²/g |
| Product Line | Acclaim |
Thermo Scientific™ Acclaim™ 300 C18 HPLC Columns
Use these wide-pore C18 columns to achieve high-resolution protein separations.
| Pore Size | 300 Å |
|---|---|
| Stationary Phase | C18 |
| Temperature | 60°C |
| For Use With | LC/MS |
| Endcapped | Yes |
| Column Type | Reversed Phase |
| Green Features | Responsibly packaged |
| Surface Area | 100 m²/g |
| Particle Size | 3 μm |
| Flow Rate | 1 mL/min |
| Carbon Load | 8% |
| pH | 2.5 to 7.5 |
| Product Line | Acclaim |
| USP Type | L1 |
Thermo Scientific™ Acclaim™ HILIC-10 HPLC Columns
Use this HILIC column to retain and separate highly polar molecules that are unretained by reversed-phase chromatography.
| Pore Size | 120 Å |
|---|---|
| Carbon Load | 8% |
| Stationary Phase | Proprietary |
| Temperature | 70°C |
| Phase | HILIC |
| For Use With | LC/MS |
| Endcapped | Yes |
| Column Type | HILIC |
| pH | 2 to 8 |
| Surface Area | 300 m²/g |
| Product Line | Acclaim |
Thermo Scientific™ Acclaim™ Carbonyl C18 HPLC Columns
Use for superior resolution and high-throughput separation of carbonyls, dinitrophenylhydrazine (DNPH) derivatives of aldehydes and ketones.
| Pore Size | 120 Å |
|---|---|
| Temperature | 50°C |
| Phase | Reversed Phase |
| Endcapped | Yes |
| pH | 2.5 to 7.5 |
| Surface Area | 300 m²/g |