HPLC Columns
- (4)
- (10)
- (7)
- (1)
- (5)
- (13)
- (1)
- (1)
- (3)
- (62)
- (1)
- (2)
- (15)
- (71)
- (10)
- (2)
- (2)
- (1)
- (1)
- (112)
- (963)
- (3)
- (43)
- (1)
- (28)
- (20)
- (4)
- (11)
- (612)
- (12)
- (2)
- (29)
- (12)
- (4)
- (285)
- (16)
- (1,239)
- (2)
- (7)
- (1)
- (7)
- (7)
- (35)
- (9)
- (30)
- (9)
- (99)
- (1)
- (8)
- (9)
- (6)
- (11)
- (5)
- (322)
- (166)
- (325)
- (7)
- (1)
- (1)
- (60)
- (1)
- (488)
- (431)
- (1)
- (55)
- (1)
- (2)
- (10)
- (13)
- (1)
- (381)
- (12)
- (335)
- (126)
- (1)
- (21)
- (156)
- (1)
- (47)
- (18)
- (1)
- (2)
- (10)
- (4)
- (2)
- (12)
- (11)
- (2)
- (313)
- (17)
- (292)
- (10)
- (1)
- (3)
- (15)
- (2)
- (3)
- (129)
- (1)
- (6)
- (2)
- (2)
- (2)
- (32)
- (5)
- (66)
- (320)
- (7)
- (1)
- (33)
- (3)
- (13)
- (157)
- (25)
- (15)
- (7)
- (6)
- (133)
- (403)
- (46)
- (686)
- (30)
- (21)
- (5)
- (1)
- (68)
- (24)
- (1,540)
- (8)
- (5)
- (22)
- (17)
- (17)
- (24)
- (4)
- (64)
- (84)
- (411)
- (41)
- (63)
- (11)
- (28)
- (102)
- (11)
- (2)
- (12)
- (56)
- (17)
- (12)
- (1)
- (31)
- (1)
- (2)
- (45)
- (2,189)
- (32)
- (11)
- (1)
- (9)
- (8)
- (10)
- (47)
- (6)
- (2)
- (4)
- (125)
- (1)
- (1)
- (4)
- (1)
- (1)
- (4)
- (7)
- (551)
- (3)
- (1)
- (2)
- (456)
- (11)
- (497)
- (18)
- (35)
- (2)
- (11)
- (2)
- (24)
- (2)
- (5)
- (83)
- (2)
- (11)
- (141)
- (236)
- (46)
- (39)
- (5)
- (70)
- (3)
- (16)
- (3)
- (35)
- (5)
- (140)
- (11)
- (14)
- (7)
- (11)
- (54)
- (3)
- (5)
- (126)
- (1)
- (1)
- (509)
- (22)
- (201)
- (6)
Filtered Search Results
MilliporeSigma™ Supelco™ Discovery™ C18 HPLC Column, 5 μm Particle Size
Use Discovery™ C18 for any method that specifies a C18. The exceptional peak shape, reproducibility, and stability make it the column of choice for all C18 methods from demanding to routine.
| Pore Size | 180 Å |
|---|---|
| Particle Size | 5 μm |
| Stationary Phase | C18 (Octadecyl) |
| Phase | Reversed Phase |
| Matrix | C18 (Octadecyl) Phase/Silica Gel, High Purity, Spherical Particle Platform |
| Endcapped | Yes |
| pH | 2 to 8 |
| Material | Stainless Steel |
| Surface Area | 200 m2/g |
| Product Line | Discovery |
MilliporeSigma™ Supelco™ Discovery™ BIO Wide Pore C5 HPLC Column, 10 μm Particle Size
Discovery™ BIO Wide Pore C5 was designed for the efficient and reliable separation of proteins and peptides, especially hydrophobic peptides, by RP- HPLC.
| Pore Size | 300 Å |
|---|---|
| Particle Size | 10 μm |
| Stationary Phase | C5 (pentyl) |
| Phase | Reversed Phase |
| Matrix | C5 (pentyl) Phase/Silica Particle Platform |
| Endcapped | Yes |
| Technique | Wide Pore HPLC |
| Surface Area | 100 m2/g |
| Product Line | Discovery |
Thermo Scientific™ Syncronis™ C18 Columns
Use for hydrophobic interaction reversed-phase separations.
| Pore Size | 100 Å |
|---|---|
| Carbon Load | 16% |
| Stationary Phase | C18 |
| Temperature | 60°C |
| Phase | Reversed Phase |
| Endcapped | Yes |
| Column Type | Reversed Phase |
| pH | 2 to 9 |
| Surface Area | 320 m²/g |
| USP Type | L1 |
TSKgel™ Butyl-NPR HPLC Column, 2.5 μm Particle Size, Sold by MilliporeSigma™ Supelco™
TSKgel™ Butyl-NPR columns are not as hydrophobic, i.e., less retentive, than Phenyl-5PW and Ether-5PW HIC columns. They are the best choice for high speed separations and provide excellent recovery even for more hydrophobic proteins.
MilliporeSigma Ascentis™ Express PCS-C18 HPLC Column
Ascentis™ Express PCS-C18 columns are specifically engineered to provide efficient separation of basic, acidic, or neutral compounds under low ionic strength (formic acid) mobile phase conditions.
| Pore Size | 90 Å |
|---|---|
| Particle Size | 2.7 μm |
| Type | HPLC Column |
| Phase | Positively Charged Surface (PCS) |
| Material | Stainless Steel |
| Technique | HPLC |
Thermo Scientific™ Acclaim™ C30 HPLC Columns
Use for superior separation of hydrophobic structural isomers.
| Pore Size | 200 Å |
|---|---|
| Carbon Load | 13% |
| Stationary Phase | C30 |
| Temperature | 60°C |
| Phase | Reversed Phase |
| Column Type | Reversed Phase |
| pH | 2 to 8 |
| Surface Area | 200 m²/g |
| Product Line | Acclaim |
MilliporeSigma™ Supelco™ Discovery™ BIO Wide Pore C18 HPLC Column, 10 μm Particle Size
The Discovery™ BIO Wide Pore C18 column has the ability to analyze peptides without TFA in the mobile phase, thereby increasing the LC-MS signal.
| Pore Size | 300 Å |
|---|---|
| Particle Size | 10 μm |
| Stationary Phase | C18 (octadecyl) |
| Phase | Reversed Phase |
| Matrix | C18 (octadecyl) Phase/silica particle platform |
| Endcapped | Yes |
| Technique | Wide Pore HPLC |
| Surface Area | 100 m2/g |
| Product Line | Discovery |
Thermo Scientific™ Accucore™ 150-C4 HPLC Columns
Use this specially designed solid core column with a C4 functionality for biomolecules that bind too tightly to C8 or C18 columns.
| Pore Size | 150 Å |
|---|---|
| Particle Size | 2.6 μm |
| Carbon Load | 2% |
| Stationary Phase | C4 |
| Temperature | 60°C |
| Phase | Reversed Phase |
| For Use With | HPLC |
| Endcapped | Yes |
| Packing Material | Spherical, Solid Core, Ultrapure Silica |
| Column Type | Reversed Phase |
| pH | 2 to 9 |
| Surface Area | 80 m²/g |
| USP Type | L26 |
Thermo Scientific™ Accucore™ Phenyl-Hexyl HPLC Columns
Use this solid core column for fast, high-resolution separations of aromatic and moderately polar compounds.
| Pore Size | 80 Å |
|---|---|
| Temperature | 70°C |
| Phase | Reversed Phase |
| Endcapped | Yes |
| Column Type | Reversed Phase |
| Surface Area | 130 m²/g |
| Max. Pressure | 14500 psi (1000 bar) |
| Particle Size | 2.6 μm |
| Carbon Load | 5% |
| Packing Material | Spherical, Solid Core, Ultrapure Silica |
| pH | 2 to 8 |
| Particle Shape | Spherical Solid Core |
| Product Line | Accucore |
| USP Type | L11 |
Restek™ Pinnacle™ DB C8 Specialty/Application Specific HPLC Column, 5 μm
Base-deactivated spherical silica optimized for UHPLC stability.
| Pore Size | 140 Å |
|---|---|
| Stationary Phase | C8 |
| Temperature | 80°C |
| Phase | Reversed Phase |
| For Use With | Analysis of Basic Compounds or Bases Mixed with Acids/Neutrals |
| Endcapped | Yes |
| Column Type | Specialty/Application Specific |
| Quantity | 5 g |
| Material | Stainless Steel |
| Max. Pressure | 4000 psi (275 bar) |
| Particle Size | 5 μm |
| Ligand Type | Monomeric C8 |
| Carbon Load | 6% |
| Packing Material | Silica |
| pH | 2.5 to 10 |
| Technique | UHPLC |
| Particle Shape | Spherical |
| Film Thickness | 5 μm |
| USP Type | L7 |
Restek™ Viva™ HPLC Columns with C18 Column Packing, 5μm Particle Size
Wide bore silica columns excellent for general-purpose applications and separating peptides or proteins
| Pore Size | 300 Å |
|---|---|
| Stationary Phase | C18 |
| Temperature | 80°C |
| Phase | Reversed Phase |
| For Use With | Analyzing Large Molecules and Biomolecules |
| Endcapped | Yes |
| Column Type | Reversed Phase |
| Particle Size | 5 μm |
| Type | Column |
| Carbon Load | 9% |
| Packing Material | Silica |
| pH | 2.5 to 10 |
| Particle Shape | Spherical |
| Film Thickness | 5 μm |
| USP Type | L1 |
| Pore Size | 100 Å |
|---|---|
| Type | Cartridge |
| Stationary Phase | C18 |
| Phase | Reversed Phase |
| Endcapped | Yes |
| Packing Material | Silica |
| Column Type | Reversed Phase |
| Material | Stainless Steel |
| USP Type | L1 |
Hamilton™ PRP-1 Reversed Phase HPLC Columns, 10um Particle Size: PEEK
Stable alternative to C8 or C18 Columns
| Pore Size | 100 Å |
|---|---|
| Stationary Phase | PRP-1 |
| Temperature | 5°C to 85°C |
| Phase | Reversed Phase |
| Column Type | Reversed Phase |
| Material | PEEK |
| Max. Pressure | 5000 psi (345 bar) |
| Column Format | Analytical Column |
| Particle Size | 10 μm |
| Flow Rate | 1.0 mL/min |
| Type | Column |
| Packing Material | PSDVB (Polystyrene Divinylbenzene) |
| Mobile Phase Compatibility | pH 1 to 13, 0 to 100% aqueous, organic modifier |
| Diameter (Metric) | 4.6 mm |
| pH | 1 to 13 |
| USP Type | L21 |
Hamilton™ PRP™-3 Reversed Phase HPLC Columns
PRP-3 polymeric 300 Å columns for gradient separations of peptides and proteins
| Pore Size | 300 Å |
|---|---|
| Particle Size | 10 μm |
| Stationary Phase | PRP-3 |
| Temperature | 5°C to 85°C |
| Phase | Reversed Phase |
| Packing Material | PSDVB (Polystyrene Divinylbenzene) |
| Column Type | Reversed Phase |
| pH | 1 to 13 |
| Max. Pressure | 5000 psi (345 bar) |
| USP Type | L21 |
Hamilton™ PRP-1 Reversed Phase HPLC Columns, 10um Particle Size: Stainless Steel
Stable alternative to C8 or C18 Columns
| Pore Size | 100 Å |
|---|---|
| Type | Column |
| Stationary Phase | PRP-1 |
| Temperature | 5°C to 85°C |
| Phase | Reversed Phase |
| Packing Material | PSDVB (Polystyrene Divinylbenzene) |
| Column Type | Reversed Phase |
| Mobile Phase Compatibility | pH 1 to 13, 0 to 100% aqueous, organic modifier |
| pH | 1 to 13 |
| Material | Stainless Steel |
| Max. Pressure | 5000 psi (345 bar) |
| USP Type | L21 |
| Column Format | Analytical Column |