ISE Concentration Meters
Benchtop or portable instruments that use an ion-selective electrode to measure the specific ionic concentration of an aqueous solution; used in chemical analysis and research; membranes may be glass, crystalline, ion-exchange resins or enzymes.
Points d’étalonnage (ionométrie)
- (1)
- (1)
- (11)
Gamme (ionométrie)
- (1)
- (1)
- (11)
Gamme (mV)
- (1)
- (1)
- (11)
Gamme (pH)
- (11)
- (1)
- (1)
Résolution (ionométrie)
- (1)
- (11)
- (1)

1
–
4
de
4
résultats
Connectez-vous ou
enregistrez-vous pour vérifier votre prix et la disponibilité.
YSI™ TruLab™ pH/ISE 1320 Dual Channel Laboratory ISE Benchtop Meter
Easy-to-use meter for dual measurement of pH, mV (ORP) or ISE and temperature
Thermo Scientific™ Orion™ Pro Star PI214 pH/ion Bench Meter
Designed to provide accurate and reliable pH, ORP, ion concentration and temperature analysis, the Thermo Scientific™ Orion™ Pro Star PI214 bench meter is well suited for laboratories that desire a modern meter with advance performance.
Certifications/Conformité | CE, TUV 3-1, FCC Class A |
---|---|
Sélection de la température | Automatic with ATC temperature sensor, ambient or manual |
Clavier | Capacitive touchscreen user interface |
Gamme (rH) | -2000 to 2000 mV |
Résolution (ionométrie) | 0.0001 minimum, 1 to 5 digits |
Précision (pH) | ±0.002 pH |
Dimensions (L x l x H) | 218.9 x 153.2 x 91.33 mm; 8.62 x 6.03 x 3.60 in. |
Garantie | 2 year meter warranty |
Measurement Modes | pH with mV and Temperature,ORP with mV and Temperature,Ion Concentration (ISE) with Temperature |
Adaptateur secteur | Universal 100-240 V 50/60 Hz power supply with wall plugs for US/Japan, Euro, UK/Singapore, Australia/New Zealand and China outlets |
Langues | Chinese, English, French, German, Italian, Japanese, Korean, Portuguese, Spanish |
Point isopotentiel | 7.000 pH; 1.000 ion concentration |
Canaux | 1 |
Modèle | PI214 |
Option de rétro-éclairage | Yes |
Sorties | USB flash drive, computer or printer (STARA-106) |
Fonctions d’ionométrie avancées | Single known addition, single known subtraction, double known addition, double known subtraction, analyte addition and analyte subtraction |
Méthodes | 10 |
Gamme (ionométrie) | 0.0001 to 19999 |
Points de données | 10,000 with Date and Time Stamp |
Points d’étalonnage (pH) | 1 to 5 points |
Poids (métrique) | 1.00 kg |
Points d’étalonnage (ionométrie) | Up to 5 |
Sorties d’alarme | Calibration reminder alarm, high and low limit alarm per parameter |
Étalonnage de la sonde de température | 1 or 2 point temperature offset calibration |
Type de fonction d’enregistrement | Automatic with Auto-Read and Timed Read Modes, Manual with Continuous Read Mode |
Résolution (pH) | 0.1, 0.01 or 0.001 pH |
Points d’étalonnage | 1 to 5 (pH), 1 (ORP), 1 to 5 (ion), 1 to 2 (temperature) |
Précision (température) | ±0.3°C, ±0.5°F |
Entrées | BNC for pH, ORP or ion selective electrode (ISE), 8-pin MiniDIN for ATC, pin-tip for reference |
Étalonnage | pH, ORP, Ion Concentration, Temperature |
Gamme (mV) | -2000 to 2000 mV |
Type d’affichage | 7-in. High-resolution Color Graphic LCD |
Gamme (mV relative) | -2000 to 2000 mV |
Mémoire | Non-volatile |
Plage (métrique) de températures | -30.0°C to +130.0°C |
Poids (impériale) | 2.20 lbs. |
Précision (mV) | ±0.2 mV or ±0.05% of the reading, whichever is greater |
Résolution (mV) | 0.1 mV |
Gamme (pH) | -2 to 20 |
Résolution (température) | 0.1°C, 0.1°F |
Précision (ions spécifiques) | ±0.2 mV or ±0.05% of the reading, whichever is greater |
Thermo Scientific™ Orion™ Pro Star PI217 Dual Channel pH/Ion Bench Meter
Designed to provide accurate and reliable pH, ORP, ion concentration and temperature analysis, the Thermo Scientific™ Orion™ Pro Star PI217 dual channel bench meter is well suited for laboratories that desire a modern meter with advance performance.
Certifications/Conformité | CE, TUV 3-1, FCC Class A |
---|---|
Sélection de la température | Automatic with ATC temperature sensor, ambient or manual |
Clavier | Capacitive touchscreen user interface |
Gamme (rH) | -2000 to 2000 mV |
Résolution (ionométrie) | 0.0001 minimum, 1 to 5 digits |
Précision (pH) | ±0.002 pH |
Dimensions (L x l x H) | 218.9 x 153.2 x 91.33 mm; 8.62 x 6.03 x 3.60 in. |
Garantie | 2 year meter warranty |
Measurement Modes | pH,ORP with mV and Temperature,Ion Concentration (ISE) with Temperature |
Adaptateur secteur | Universal 100-240 V 50/60 Hz power supply with wall plugs for US/Japan, Euro, UK/Singapore, Australia/New Zealand and China outlets |
Langues | Chinese, English, French, German, Italian, Japanese, Korean, Portuguese, Spanish |
Point isopotentiel | 7.000 pH; 1.000 ion concentration |
Canaux | 2 |
Modèle | PI217 |
Option de rétro-éclairage | Yes |
Sorties | USB flash drive, computer or printer (STARA-106) |
Fonctions d’ionométrie avancées | Single known addition, single known subtraction, double known addition, double known subtraction, analyte addition and analyte subtraction |
Méthodes | 10 per channel (20 total) |
Gamme (ionométrie) | 0.0001 to 19999 |
Points de données | 10,000 with Date and Time Stamp |
Points d’étalonnage (pH) | 1 to 5 points |
Poids (métrique) | 1.00 kg |
Points d’étalonnage (ionométrie) | Up to 5 |
Sorties d’alarme | Calibration reminder alarm, high and low limit alarm per parameter |
Étalonnage de la sonde de température | 1 or 2 point temperature offset calibration |
Type de fonction d’enregistrement | Automatic with Auto-Read and Timed Read Modes, Manual with Continuous Read Mode |
Résolution (pH) | 0.1, 0.01 or 0.001 pH |
Points d’étalonnage | 1 to 5 (pH), 1 (ORP), 1 to 5 (ion), 1 to 2 (temperature) |
Précision (température) | ±0.3°C, ±0.5°F |
Entrées | Channel 1: BNC for pH, ORP or ISE, 8-pin MiniDIN for ATC, pin-tip for reference; Channel 2: BNC for pH, ORP or ISE, 8-pin MiniDIN for ATC, pin-tip for reference |
Étalonnage | pH, ORP, Ion Concentration, Temperature |
Gamme (mV) | -2000 to 2000 mV |
Type d’affichage | 7-in. High-resolution Color Graphic LCD |
Gamme (mV relative) | -2000 to 2000 mV |
Mémoire | Non-volatile |
Plage (métrique) de températures | -30.0°C to +130.0°C |
Poids (impériale) | 2.20 lbs. |
Précision (mV) | ±0.2 mV or ±0.05% of the reading, whichever is greater |
Résolution (mV) | 0.1 mV |
Gamme (pH) | -2 to 20 |
Résolution (température) | 0.1°C, 0.1°F |
Précision (ions spécifiques) | ±0.2 mV or ±0.05% of the reading, whichever is greater |
Thermo Scientific™ Orion™ Dual Star™ pH, ISE, mV, ORP and Temperature Dual Channel Benchtop Meter
Accurately monitor pH, ion concentration, mV, ORP and temperature on two channels with our pH/ISE benchtop meter for advanced lab analysis.
Certifications/Conformité | CE, TUV 3-1, FCC Class A |
---|---|
Sélection de la température | Manual or automatic with ATC temperature probe |
Clavier | Numeric with menu-specific function keys and dual purpose scroll/shortcut keys |
Gamme (rH) | ±1999.9 mV |
Résolution (ionométrie) | 0.0001 minimum, 1 to 3 significant digits (user selectable) |
Précision (pH) | ±0.002 |
Dimensions (L x l x H) | 24 x 17 x 9 cm (9.5 x 6.7 x 3.5 in.) |
Garantie | 3 Year Meter Warranty |
Measurement Modes | pH,mV,Relative mV,ORP,Ion Concentration (ISE) with Temperature |
Adaptateur secteur | Universal 50 to 60 Hz, 100 to 240 VAC power adapter (Cat. No. 1010003) |
Langues | English, Spanish, French, Italian and German |
Point isopotentiel | 7.000 pH (adjustable), 1.000 ISE (adjustable) |
Canaux | 2 |
Modèle | Orion Dual Star pH/ISE/mV/RmV/ORP/Temperature Dual Channel Benchtop Meter |
Option de rétro-éclairage | Yes, adjustable |
Température (impériale) en fonctionnement | 41°F to 113°F (ambient) |
Sorties | USB, RS232 |
Stabilité | Smart Stability and Smart Averaging |
Fonctions d’ionométrie avancées | Segmented (point-to-point) slope, non-linear selectable auto-blank, low concentration range stabilit |
Méthodes | 10 per channel with password protection |
Détails de la gestion des données | Transfer single, range or all data points to printer or computer |
Gamme (ionométrie) | 0.0001 to 19,900 in ppm, M, mg/L, % or unit-less |
Points de données | 1000 with Date and Time Stamp |
Points d’étalonnage (pH) | 1 to 6 |
Poids (métrique) | 0.9 kg |
Points d’étalonnage (ionométrie) | 2 to 6 |
Sorties d’alarme | High/low limit alarm |
Étalonnage de la sonde de température | 1 point temperature offset calibration |
Type de fonction d’enregistrement | Automatic data logging with Auto-Read, On Ready, At Timed Intervals, Value Change In Measurement and |
Résolution (pH) | 0.1, 0.01, 0.001 |
Points d’étalonnage | 1 point relative mV (RmV) mode, 1 point ORP mode |
Précision (température) | ±0.1°C |
Entrées | Two BNC (pH, ORP or ion selective electrode), two pin-tip (reference electrode), two 8 pin MiniDIN (ATC temperature probe), stirrer input (stirrer probe) |
Étalonnage | pH with calibration editing option, ion concentration (ISE) with calibration editing option, relativ |
Gamme (mV) | ±1999.9 mV |
Type d’affichage | Graphic LCD with Backlight |
Alimentation électrique | 90 to 260 VAC 50/60 Hz |
Gamme (mV relative) | ±1999.9 mV |
Mémoire | Non-volatile memory preserves data log, calibration log and meter settings |
Plage (métrique) de températures | -5.0°C to +105.0°C |
Poids (impériale) | 2 lb. |
Température (métrique) en fonctionnement | 5°C to 45°C (ambient) |
Précision (mV) | ±0.2 mV or ±0.05% of reading whichever is greater |
Résolution (mV) | 0.1 mV |
Gamme d’humidité relative | 5 to 85 %, non-condensing |
Gamme (pH) | -2.000 to 19.999 |
Résolution (température) | 0.1°C, 0.1°F |
Précision (ions spécifiques) | ±0.2 mV or ±0.05% of reading whichever is greater |