Electrochemistry Meters
Résultats de la recherche filtrée
Fisherbrand™ accumet™ AP125 Portable pH/Ion/mV/Temperature Meter
Accurate measurements any time, anywhere
| Précision | Multiple |
|---|---|
| Type de produit | Meter Only |
| Garantie | 3 Years |
| Résolution (pH) | Adjustable |
| Measurement Modes | pH,Ion,mV,Temperature |
| Points d’étalonnage | 10 |
| Résolution | Multiple |
| Gamme (mV) | 0 to ±2000 mV |
| À utiliser avec (application) | pH, Ion concentration, mV, Temperature |
| Type d’affichage | LCD |
| Précision (mV) | 0 to ±2000mV |
| Plage de températures (métrique) | -5°C to +100°C |
| Indice IP | IP67 |
| Plage | -2 to +20pH |
| Comprend | Meter, 9V battery, manual |
| Gamme (pH) | 2 to 20 |
| Plage de températures (impériale) | 23°F to 212°F |
| Points de données | 200 |
Fisherbrand™ accumet™ Basic AB330 Benchtop Laboratory Conductivity Meter
Ideal for daily conductivity, TDS and salinity testing of your routine laboratory samples, the accumet™ Basic AB330 Benchtop Meter provides essential functions needed without complicated functions at a budget-friendly price.
| Compensation thermique | Linear |
|---|---|
| Garantie | 3 Years |
| Adaptateur secteur | Universal Power Adapter |
| Résolution (TDS) | 0.01, 0.1, 1 ppm; 0.01, 0.1 ppt |
| Measurement Modes | Conductivity with Temperature,TDS with Temperature,Salinity with Temperature |
| Points d’étalonnage (conductivité) | 84 μS, 1413 μS, 12.88 mS, 111.8 mS |
| Modèle | AB330 |
| Option de rétro-éclairage | Yes |
| Gamme (salinité) | 0 to 80 ppt |
| Fréquence | 50/60 Hz |
| Sorties | Port for Computer or Printer |
| Stabilité | Indicator Icons |
| Détails de la gestion des données | Printed or CSV Format |
| Indice IP | IP54 |
| Gamme de facteurs TDS | 0.4 to 1 |
| Tension | 100/240 V |
| Coefficient thermique | 0 to 10 %/°C |
| Points de données | 500 |
| Précision (conductivité) | ±1% Full Scale |
| Constante de cellule | 0.1 to 10 |
| Résolution (salinité) | 0.01, 0.1 ppt |
| Précision (température) | ±0.3°C (±0.5°F) |
| Points d’étalonnage | 1 to 5 (Conductivity), 1 to 5 (TDS), 1 (Salinity), 1 (Temperature) |
| Entrées | Conductivity, ATC |
| Étalonnage | Conductivity, TDS, Salinity, Temperature |
| Température (métrique) de référence | 15, 20, 25 or 30°C |
| Enregistrement des données | Automatic with Auto-read and Timed Modes, Manual with Continuous Mode |
| Type d’affichage | 5 in. LCD |
| Résolution (conductivité) | 0.01, 0.1, 1 μS; 0.01, 0.1 mS |
| Mémoire | Non-volatile |
| Plage de températures (métrique) | -5°C to +105°C |
| Précision (TDS) | ±1% Full Scale |
| Résolution (température) | 0.1°C (0.1°F) |
| Précision (salinité) | ±1% Full Scale |
| Gamme (conductivité) | 0 μS to 500 mS |
Fisherbrand™ accumet™ AP125 Portable pH/Ion/mV/Temperature Meter Kit
Accurate measurements any time, anywhere
Fisherbrand™ Traceable™ Portable Dissolved Oxygen Meter
Traceable™ Portable Dissolved Oxygen Meter is traceable to NIST™ standards.
Fisherbrand™ Traceable™ Dual-Display Conductivity Meter
Measures conductivity and temperature; includes NIST™ traceability certificate.
Fisherbrand™ accumet™ XL600 Benchtop Dual pH/ISE, Conductivity and Dissolved Oxygen Meters
Provide advanced measurements with simple operation and offer a large, vivid color touch-screen display. Fisherbrand accumet XL600 pH/ISE/conductivity/DO benchtop meters offer advanced features with simple operation to help ensure your measurements are reliable and your laboratory processes are efficient.
| Certifications/Conformité | NIST, ISO, FDA, USDA, EPA |
|---|---|
| Précision (résistivité) | ± 1% full scale |
| Longueur (impériale) | 9.68 in. |
| Détails de la gestion des données | 3 to 86400 sec. |
| Tension | 100/240 V |
| Précision de la température | ±0.2°C (±0.3°F) |
| Gamme de détection | Multiple |
| Points d’étalonnage (pH) | Up to 6 preset or 5 custom |
| Poids (métrique) | 1.13 kg |
| Gamme (OD) | 0 to 20mg/L (0 to 1272mbar), 0 to 200% saturation with 13-620-SSP electrode |
| Résolution (pH) | 0.1/0.01/0.001 |
| Entrées | 2 BNC, 2 ATC |
| Résolution (conductivité) | 0.001/0.01/0.1mS |
| Type d’affichage | LCD |
| Précision (DO) | 0.1 +1 LSD |
| Poids (impériale) | 2.5 lb. |
| Résolution (mV) | 0.1mV |
| Précision (TDS) | ± 1% full scale |
| Précision (salinité) | ± 1% full scale |
| Hauteur (impériale) | 3.89 in. |
| Précision | Multiple |
| Résolution de la température | 0.1°C |
| Résolution (ionométrie) | 2/3/4 Digits |
| Précision (pH) | ±0.002 |
| Dimensions (L x l x H) | 24.6 x 17.3 x 9.9cm (9.7 x 6.8 x 3.9 in.) |
| Garantie | 3 Years |
| Résolution (TDS) | 0.01/0.1ppm, 0.001/0.01/0.1ppt |
| Gamme (ions spécifiques) | ±2000 mV |
| Points d’étalonnage (conductivité) | Automatic (4 points), maximum 1/range, manual (5 points), maximum 1/range |
| Résolution (OD) | 0.01mg/L (0.1mbar), 0.1% saturation |
| Gamme (salinité) | 0 to 80 ppt |
| Fréquence | 50/60Hz |
| Sorties | RS232, USB-A, Mini-B USB, RJ45, stirrer port (2) |
| Gamme (résistivité) | 3 W to 100 MW over 4 ranges: 0 to 20 kW, 20 to 200 kW, 200 kW to 2 MW, 2 to 100 MW |
| Points de données | 2000 |
| Points d’étalonnage (ionométrie) | 2 to 6 |
| Précision (conductivité) | ±1% FS |
| Longueur (métrique) | 24.6 cm |
| Constante de cellule | 0.01 to 10 |
| Résolution (salinité) | 0.01/0.1ppm, 0.001/0.01/0.1ppt |
| Résolution (résistivité) | 0.01/0.1W, 0.001/0.1kW, 0.01MW |
| Gamme (TDS) | 0.050 ppm to 500 ppt (at TDS factor 1.00) |
| Résolution | Multiple |
| Gamme (mV) | ±2000 mV |
| Hauteur (métrique) | 9.9 cm |
| Largeur (métrique) | 17.3 cm |
| Précision (mV) | ±0.2 mV |
| Gamme (pH) | -2 to 20 |
| Gamme (conductivité) | 0 to 500 mS |
| Précision (ions spécifiques) | 0.5% full scale (monovalent ion), 1% full scale (divalent ion) |
Fisherbrand™ accumet™ XL200 Benchtop pH/Conductivity Meters
Provide advanced measurements with simple operation and offer a large, vivid color touch-screen display that allows for dynamic functionality. Fisherbrand accumet XL200 pH/Conductivity benchtop meters offer advanced features with simple operation to help ensure your measurements are reliable and your laboratory processes are efficient.
| Hauteur (impériale) | 3.89 in. |
|---|---|
| Certifications/Conformité | NIST, ISO, FDA, USDA, EPA |
| Précision (résistivité) | ± 1% full scale |
| Précision | Multiple |
| Résolution de la température | 0.1°C |
| Précision (pH) | ±0.002 |
| Dimensions (L x l x H) | 24.6 x 17.3 x 9.9cm (9.7 x 6.8 x 3.9 in.) |
| Garantie | 3 Years |
| Résolution (TDS) | 0.01/0.1ppm, 0.001/0.01/0.1ppt |
| Points d’étalonnage (conductivité) | Automatic (4 points), maximum 1/range, manual (5 points), maximum 1/range |
| Gamme (salinité) | 0 to 80 ppt |
| Fréquence | 50/60Hz |
| Longueur (impériale) | 9.68 in. |
| Sorties | RS232, USB-A, Mini-B USB, RJ45, stirrer port (2) |
| Détails de la gestion des données | 3 to 86400 sec. |
| Tension | 100/240 V |
| Précision de la température | ±0.2°C |
| Gamme (résistivité) | 3 W to 100 MW over 4 ranges: 0 to 20 kW, 20 to 200 kW, 200 kW to 2 MW, 2 to 100 MW |
| Gamme de détection | Multiple |
| Points de données | 2000 |
| Points d’étalonnage (pH) | Up to 6 preset or 5 custom |
| Poids (métrique) | 1.13 kg |
| Précision (conductivité) | ±1% FS |
| Longueur (métrique) | 24.6 cm |
| Constante de cellule | 0.01 to 10 |
| Résolution (salinité) | 0.01/0.1ppm, 0.001/0.01/0.1ppt |
| Résolution (résistivité) | 0.01/0.1W, 0.001/0.1kW, 0.01MW |
| Résolution (pH) | 0.1/0.01/0.001 |
| Gamme (TDS) | 0.050 ppm to 500 ppt (at TDS factor 1.00) |
| Résolution | Multiple |
| Entrées | BNC, ATC |
| Gamme (mV) | ±2000 mV |
| Résolution (conductivité) | 0.001/0.01/0.1mS |
| Type d’affichage | LCD |
| Hauteur (métrique) | 9.9 cm |
| Largeur (métrique) | 17.3 cm |
| Poids (impériale) | 2.5 lb. |
| Précision (mV) | ±0.2 mV |
| Résolution (mV) | 0.1mV |
| Gamme (pH) | -2 to 20 |
| Précision (TDS) | ± 1% full scale |
| Gamme (conductivité) | 0 to 500 mS |
| Précision (salinité) | ± 1% full scale |
Fisherbrand™ Traceable™ pH/ORP/Temperature Meter
Measure critical water quality parameters — without the need to carry multiple units.
Fisherbrand™ Traceable™ Conductivity/TDS Meter Pen
Easy-to-use, waterproof conductivity/TDS meter designed for routine analysis and quality control. Simply turn on, insert, and simultaneously read result and temperature.
Fisherbrand™ Traceable™ Salinity Meter Pen
Easy-to-use and splash-proof salinity meter designed for routine analysis and quality control. Simply turn on, insert, and simultaneously read result and temperature.
Fisherbrand™ Traceable™ Expanded Range Conductivity Meter
Ideal for checking the purity of water from stills, deionizers, and reverse osmosis, testing laboratory glassware rinsing, measuring total dissolved solids, and making solutions.
Fisherbrand™ Traceable™ Conductivity Meter Pen
Easy-to-use, waterproof conductivity meter designed for routine analysis and quality control. Simply turn on, insert, and simultaneously read result and temperature.
METTLER TOLEDO™ S600 SevenExcellence™ Dissolved Oxygen Benchtop Meter Kit
The S600 meter kit includes a meter, electrode, and accessories to measure disolved oxygen (DO). The meter can be expanded with additional modules to measure pH, conductivity, and ISE. It has an intuitive touchscreen, measurement shortcuts, and can export data to a printer, Excel, or LIMS system.
Thermo Scientific™ Orion Star™ A321 pH Portable Meter
Accurately monitor pH, mV, ORP and temperature with our waterproof, portable pH meter for high performance in challenging field locations.
| Certifications/Conformité | CE, TUV 3-1, FCC Class A |
|---|---|
| Sélection de la température | Manual or automatic with ATC temperature probe |
| Clavier | Comprehensive with menu-specific function keys and dual purpose scroll/shortcut keys |
| Résolution de la température | 0.1°C, 0.1°F |
| Gamme (rH) | ±2000.0 mV |
| Précision (pH) | ±0.002 |
| Dimensions (L x l x H) | 24cm x 10cm x 6.5cm (9.5 in. x 3.9 in. x 2.6 in.) |
| Garantie | 3 Year Meter |
| Measurement Modes | pH,mV,Relative mV,ORP with Temperature |
| Adaptateur secteur | Universal 50-60 Hz, 100-240 VAC power adapter (sold separately, Cat. No. 1010003) |
| Langues | English, Spanish, French, Italian, German and Chinese; Portuguese and Korean available with software update |
| Point isopotentiel | 7.000pH |
| Canaux | 1 |
| Modèle | Orion Star A321 pH/mV/RmV/ORP/Temperature Portable Meter |
| Option de rétro-éclairage | Yes (Selectable) |
| Type de batterie | 4 x AA |
| Température (impériale) en fonctionnement | 41°F to 113°F (ambient) |
| Sorties | USB, RS-232 |
| Stabilité | Selectable fast, medium, slow or Smart Stability setting; Selectable off or Automatic Smart averaging setting |
| Méthodes | 10 per channel with password protection |
| Détails de la gestion des données | Transfer single, range or all data points to printer or computer |
| Indice IP | IP67 |
| Précision de la température | ±0.1°C |
| Points de données | 5000 with Date and Time Stamp |
| Poids (métrique) | 0.5 kg |
| Sorties d’alarme | High/low limit alarm, calibration due alarm |
| Étalonnage de la sonde de température | 1 point temperature offset calibration |
| Type de fonction d’enregistrement | Automatic data logging with Auto-Read and Timed measure modes; manual data logging with Continuous m |
| Résolution (pH) | 0.1/0.01/0.001 |
| Points d’étalonnage | 1 to 5 |
| Entrées | BNC (pH or ORP electrode), pin-tip (reference electrode), 8 pin MiniDIN (ATC temperature probe) |
| Étalonnage | pH with calibration editing option, relative mV (RmV), ORP and temperature |
| Gamme (mV) | ±2000.0 mV |
| Type d’affichage | LCD Graphic, Backlit |
| Alimentation électrique | 4 AA batteries (included) or universal AC adapter (sold separately) |
| Gamme (mV relative) | ±2000.0 mV |
| Mémoire | Non-volatile memory preserves data log, calibration log and meter settings |
| Poids (impériale) | 1.2 lb. |
| Température (métrique) en fonctionnement | 5°C to 45°C (ambient) |
| Précision (mV) | ±0.2 mV or ±0.05% of reading whichever is greater |
| Résolution (mV) | 0.1mV |
| Plage de températures (métrique) | -5.0°C to +105.0°C |
| Autonomie de la batterie | 800 hr. |
| Gamme d’humidité relative | 5 to 85%, non-condensing |
| Gamme (pH) | -2 to 20 |
| Plage de températures (impériale) | 22.0°F to 221.0° F |
Thermo Scientific™ Orion™ Pro Star MP218 pH/ion, Conductivity and DO Bench Meter
Designed to provide accurate and reliable pH, ORP, ion, conductivity, TDS, salinity, resistivity, DO, barometric pressure and temperature analysis, the Thermo Scientific™ Orion™ Pro Star MP218 bench meter is well suited for laboratories that desire a modern meter with advance performance.
| Certifications/Conformité | CE, TUV 3-1, FCC Class A |
|---|---|
| Clavier | Capacitive touchscreen user interface |
| Précision (résistivité) | ±0.5% reading |
| Measurement Modes | pH,ORP,mV,Ion Concentration (ISE),Conductivity,Dissolved Oxygen (mg/L),Temperature,Barometric Pressure |
| Langues | Chinese, English, French, German, Italian, Japanese, Korean, Portuguese, Spanish |
| Option de rétro-éclairage | Yes |
| Fonctions d’ionométrie avancées | Single known addition, single known subtraction, double known addition, double known subtraction, analyte addition and analyte subtraction |
| Précision de la température | ±0.3°C, ±0.5°F |
| Points d’étalonnage (pH) | 1 to 5 points |
| Poids (métrique) | 1.00 kg |
| Gamme (OD) | 0.0 to 600.0% saturation; 0.01 to 90.0 mg/L or ppm |
| Sorties d’alarme | Calibration reminder alarm, high and low limit alarm per parameter |
| Type de fonction d’enregistrement | Automatic with Auto-Read and Timed Read Modes, Manual with Continuous Read Mode |
| Résolution (pH) | 0.1, 0.01 or 0.001 pH |
| Percent Saturation Range Polarographic DO | 0.0 to 600.0% saturation |
| Résolution (rH) | 0.1 mV |
| Entrées | Channel 1: BNC for pH, ORP or ISE, 8-pin MiniDIN for ATC, pin-tip for reference; Channel 2: 8-pin MiniDIN for conductivity with ATC; Channel 3: 9-pin MiniDIN for dissolved oxygen with ATC |
| Étalonnage | pH, ORP, Ion Concentration, Conductivity, TDS, Salinity, DO, Barometric Pressure, Temperature |
| Température (métrique) de référence | 5, 10, 15, 20, 25 or 30°C |
| Résolution (conductivité) | 0.001 μS/cm minimum, auto-ranging, up to 4 digits |
| Type d’affichage | 7-in. High-resolution Color Graphic LCD |
| Gamme (RDO) | 0.0 to 600.0% saturation; 0.01 to 90.0 mg/L or ppm |
| Gamme (mV relative) | -2000 to 2000 mV |
| Mémoire | Non-volatile |
| Précision (DO) | ±2% saturation; ±0.02 mg/L or ppm |
| Poids (impériale) | 2.20 lbs. |
| Précision (baromètre) | ±6.0 mmHg; ±0.008 bar |
| Résolution (mV) | 0.1 mV |
| Plage de températures (métrique) | -30.0°C to +130.0°C |
| Facteur de salinité | 0.0 to 50.0 ppt; automatic with conductivity measurement or manual entry |
| Plage de saturation en pourcentage (RDO) | 0.0 to 600.0% saturation |
| Percent Saturation Relative Accuracy (RDO) | ±2% saturation |
| Précision (TDS) | ±0.5% reading |
| Précision (salinité) | ±0.5% reading |
| Sélection de la température | Automatic with ATC temperature sensor, ambient or manual |
| Compensation thermique | Linear (0.00 to 10.00 %/°C), nLFn (non-linear natural water), nLFu (non-linear ultra-pure water), EP/USP or off |
| Type de sonde | Polarographic or optical DO electrode |
| Résolution de la température | 0.1°C, 0.1°F |
| Gamme (rH) | -2000 to 2000 mV |
| Résolution (ionométrie) | 0.0001 minimum, 1 to 5 digits |
| Résolution du coefficient de saturation (RDO) | 0.1, 1% saturation |
| Correction de la pression barométrique | Yes, automatic with built-in barometer or manual |
| Résolution (ion) | 0.0001 minimum, 1 to 5 digits |
| Précision (pH) | ±0.002 pH |
| Dimensions (L x l x H) | 218.9 x 153.2 x 91.33 mm; 8.62 x 6.03 x 3.60 in. |
| Garantie | 2 year meter warranty |
| Précision (rH) | ±0.2 mV or ±0.05% of the reading, whichever is greater |
| Résolution (TDS) | 0.001 ppm or mg/L minimum, auto-ranging, up to 4 digits |
| Gamme (ions spécifiques) | 0.0001 to 19999 |
| Précision (OD par mesure polarographique) | ±2% saturation; ±0.02 mg/L or ppm |
| Adaptateur secteur | Universal 100-240 V 50/60 Hz power supply with wall plugs for US/Japan, Euro, UK/Singapore, Australia/New Zealand and China outlets |
| Point isopotentiel | 7.000 pH; 1.000 ion concentration |
| Canaux | 3 |
| Points d’étalonnage (conductivité) | 1 to 5 points |
| Résolution (OD) | 0.1, 1% saturation; 0.01, 0.1 mg/L or ppm |
| Modes de mesure de la salinité | Natural Seawater (ppt), Practical Salinity Units (PSU), or % NaCl |
| Gamme (salinité) | 0.010 to 80.00 ppt; 0.01 to 42.00 PSU; or 0.01 to 400.0% NaCl |
| Sorties | USB flash drive, computer or printer (STARA-106) |
| Méthodes | 10 per channel (30 total) |
| Gamme de facteurs TDS | Linear (0.01 to 10.00), ISO/EN 27888, 442, NaCl |
| Gamme (OD par mesure polarographique) | 0.0 to 600.0% saturation; 0.01 to 90.0 mg/L or ppm |
| Indice IP | IP54 |
| Percent Saturation Relative Accuracy (Polarographic DO) | ±2% saturation |
| Gamme (résistivité) | 1.0Ω to 100.0 MΩ |
| Points de données | 10,000 with Date and Time Stamp |
| Points d’étalonnage (ionométrie) | Up to 5 |
| Précision (conductivité) | ±0.5% reading |
| Gamme de pression | 400.0 to 850.0 mmHg; 0.533 to 1.133 bar |
| Étalonnage de la sonde de température | 1 or 2 point temperature offset calibration |
| Constante de cellule | 0.100 cm-1, 0.475 cm-1, 0.550 cm-1, 1.000 cm-1, 10.00 cm-1 or user-defined from 0.001 to 199.9 cm-1 |
| Résolution (salinité) | 0.001 ppt minimum; 0.01 PSU minimum; or 0.01% NaCl minimum, auto-ranging |
| Résolution (résistivité) | 0.1 Ωminimum, auto-ranging |
| Gamme (TDS) | 0.010 ppm to 500.0 ppt (TDS factor of 1.00); or 0.010 mg/L to 500.0 g/L (TDS factor of 1.00) |
| Résolution (OD par mesure polarographique) | 0.1, 1% saturation; 0.01, 0.1 mg/L or ppm |
| Points d’étalonnage | 1 to 5 (pH), 1 (ORP), 1 to 5 (ion), 1 to 5 (conductivity), 1 to 5 (TDS), 1 (salinity), 1 to 2 (DO), 1 (barometer), 1 to 2 (temperature) |
| Modes d’étalonnage | Water-saturated air (100% and 0% saturation), air-saturated water (100% and 0% saturation) or custom concentration value (Winkler) |
| Gamme (ion) | 0.0001 to 19999 |
| Gamme (mV) | -2000 to 2000 mV |
| Percent Saturation Resolution (Polarographic DO) | 0.1, 1% saturation |
| Précision (mV) | ±0.2 mV or ±0.05% of the reading, whichever is greater |
| Résolution (RDO) | 0.1, 1% saturation; 0.01, 0.1 mg/L or ppm |
| Gamme (pH) | -2 to 20 |
| Plage de températures (impériale) | -22.0°F to +266.0°F |
| Gamme (conductivité) | 0.010 μS/cm to 3000 mS/cm |
| Précision (RDO) | ±2% saturation; ±0.02 mg/L or ppm |
| Précision (ions spécifiques) | ±0.2 mV or ±0.05% of the reading, whichever is greater |