Electrochemistry Meters
Résultats de la recherche filtrée
Fisherbrand™ Traceable™ Salinity Meter Pen
Easy-to-use and splash-proof salinity meter designed for routine analysis and quality control. Simply turn on, insert, and simultaneously read result and temperature.
Fisherbrand™ Traceable™ Conductivity Meter Pen
Easy-to-use, waterproof conductivity meter designed for routine analysis and quality control. Simply turn on, insert, and simultaneously read result and temperature.
Fisherbrand™ Traceable™ Conductivity/TDS Meter Pen
Easy-to-use, waterproof conductivity/TDS meter designed for routine analysis and quality control. Simply turn on, insert, and simultaneously read result and temperature.
Fisherbrand™ Traceable™ Expanded Range Conductivity Meter
Ideal for checking the purity of water from stills, deionizers, and reverse osmosis, testing laboratory glassware rinsing, measuring total dissolved solids, and making solutions.
Fisherbrand™ accumet™ AP125 Portable pH/Ion/mV/Temperature Meter
Accurate measurements any time, anywhere
| Précision | Multiple |
|---|---|
| Type de produit | Meter Only |
| Garantie | 3 Years |
| Résolution (pH) | Adjustable |
| Measurement Modes | pH,Ion,mV,Temperature |
| Points d’étalonnage | 10 |
| Résolution | Multiple |
| Gamme (mV) | 0 to ±2000 mV |
| À utiliser avec (application) | pH, Ion concentration, mV, Temperature |
| Type d’affichage | LCD |
| Précision (mV) | 0 to ±2000mV |
| Plage de températures (métrique) | -5°C to +100°C |
| Indice IP | IP67 |
| Plage | -2 to +20pH |
| Comprend | Meter, 9V battery, manual |
| Gamme (pH) | 2 to 20 |
| Plage de températures (impériale) | 23°F to 212°F |
| Points de données | 200 |
Fisherbrand™ Traceable™ pH/ORP/Temperature Meter
Measure critical water quality parameters — without the need to carry multiple units.
Fisherbrand™ accumet™ XL600 Benchtop Dual pH/ISE, Conductivity and Dissolved Oxygen Meters
Provide advanced measurements with simple operation and offer a large, vivid color touch-screen display. Fisherbrand accumet XL600 pH/ISE/conductivity/DO benchtop meters offer advanced features with simple operation to help ensure your measurements are reliable and your laboratory processes are efficient.
| Certifications/Conformité | NIST, ISO, FDA, USDA, EPA |
|---|---|
| Précision (résistivité) | ± 1% full scale |
| Longueur (impériale) | 9.68 in. |
| Détails de la gestion des données | 3 to 86400 sec. |
| Tension | 100/240 V |
| Précision de la température | ±0.2°C (±0.3°F) |
| Gamme de détection | Multiple |
| Points d’étalonnage (pH) | Up to 6 preset or 5 custom |
| Poids (métrique) | 1.13 kg |
| Gamme (OD) | 0 to 20mg/L (0 to 1272mbar), 0 to 200% saturation with 13-620-SSP electrode |
| Résolution (pH) | 0.1/0.01/0.001 |
| Entrées | 2 BNC, 2 ATC |
| Résolution (conductivité) | 0.001/0.01/0.1mS |
| Type d’affichage | LCD |
| Précision (DO) | 0.1 +1 LSD |
| Poids (impériale) | 2.5 lb. |
| Résolution (mV) | 0.1mV |
| Précision (TDS) | ± 1% full scale |
| Précision (salinité) | ± 1% full scale |
| Hauteur (impériale) | 3.89 in. |
| Précision | Multiple |
| Résolution de la température | 0.1°C |
| Résolution (ionométrie) | 2/3/4 Digits |
| Précision (pH) | ±0.002 |
| Dimensions (L x l x H) | 24.6 x 17.3 x 9.9cm (9.7 x 6.8 x 3.9 in.) |
| Garantie | 3 Years |
| Résolution (TDS) | 0.01/0.1ppm, 0.001/0.01/0.1ppt |
| Gamme (ions spécifiques) | ±2000 mV |
| Points d’étalonnage (conductivité) | Automatic (4 points), maximum 1/range, manual (5 points), maximum 1/range |
| Résolution (OD) | 0.01mg/L (0.1mbar), 0.1% saturation |
| Gamme (salinité) | 0 to 80 ppt |
| Fréquence | 50/60Hz |
| Sorties | RS232, USB-A, Mini-B USB, RJ45, stirrer port (2) |
| Gamme (résistivité) | 3 W to 100 MW over 4 ranges: 0 to 20 kW, 20 to 200 kW, 200 kW to 2 MW, 2 to 100 MW |
| Points de données | 2000 |
| Points d’étalonnage (ionométrie) | 2 to 6 |
| Précision (conductivité) | ±1% FS |
| Longueur (métrique) | 24.6 cm |
| Constante de cellule | 0.01 to 10 |
| Résolution (salinité) | 0.01/0.1ppm, 0.001/0.01/0.1ppt |
| Résolution (résistivité) | 0.01/0.1W, 0.001/0.1kW, 0.01MW |
| Gamme (TDS) | 0.050 ppm to 500 ppt (at TDS factor 1.00) |
| Résolution | Multiple |
| Gamme (mV) | ±2000 mV |
| Hauteur (métrique) | 9.9 cm |
| Largeur (métrique) | 17.3 cm |
| Précision (mV) | ±0.2 mV |
| Gamme (pH) | -2 to 20 |
| Gamme (conductivité) | 0 to 500 mS |
| Précision (ions spécifiques) | 0.5% full scale (monovalent ion), 1% full scale (divalent ion) |
Fisherbrand™ accumet™ XL200 Benchtop pH/Conductivity Meters
Provide advanced measurements with simple operation and offer a large, vivid color touch-screen display that allows for dynamic functionality. Fisherbrand accumet XL200 pH/Conductivity benchtop meters offer advanced features with simple operation to help ensure your measurements are reliable and your laboratory processes are efficient.
| Hauteur (impériale) | 3.89 in. |
|---|---|
| Certifications/Conformité | NIST, ISO, FDA, USDA, EPA |
| Précision (résistivité) | ± 1% full scale |
| Précision | Multiple |
| Résolution de la température | 0.1°C |
| Précision (pH) | ±0.002 |
| Dimensions (L x l x H) | 24.6 x 17.3 x 9.9cm (9.7 x 6.8 x 3.9 in.) |
| Garantie | 3 Years |
| Résolution (TDS) | 0.01/0.1ppm, 0.001/0.01/0.1ppt |
| Points d’étalonnage (conductivité) | Automatic (4 points), maximum 1/range, manual (5 points), maximum 1/range |
| Gamme (salinité) | 0 to 80 ppt |
| Fréquence | 50/60Hz |
| Longueur (impériale) | 9.68 in. |
| Sorties | RS232, USB-A, Mini-B USB, RJ45, stirrer port (2) |
| Détails de la gestion des données | 3 to 86400 sec. |
| Tension | 100/240 V |
| Précision de la température | ±0.2°C |
| Gamme (résistivité) | 3 W to 100 MW over 4 ranges: 0 to 20 kW, 20 to 200 kW, 200 kW to 2 MW, 2 to 100 MW |
| Gamme de détection | Multiple |
| Points de données | 2000 |
| Points d’étalonnage (pH) | Up to 6 preset or 5 custom |
| Poids (métrique) | 1.13 kg |
| Précision (conductivité) | ±1% FS |
| Longueur (métrique) | 24.6 cm |
| Constante de cellule | 0.01 to 10 |
| Résolution (salinité) | 0.01/0.1ppm, 0.001/0.01/0.1ppt |
| Résolution (résistivité) | 0.01/0.1W, 0.001/0.1kW, 0.01MW |
| Résolution (pH) | 0.1/0.01/0.001 |
| Gamme (TDS) | 0.050 ppm to 500 ppt (at TDS factor 1.00) |
| Résolution | Multiple |
| Entrées | BNC, ATC |
| Gamme (mV) | ±2000 mV |
| Résolution (conductivité) | 0.001/0.01/0.1mS |
| Type d’affichage | LCD |
| Hauteur (métrique) | 9.9 cm |
| Largeur (métrique) | 17.3 cm |
| Poids (impériale) | 2.5 lb. |
| Précision (mV) | ±0.2 mV |
| Résolution (mV) | 0.1mV |
| Gamme (pH) | -2 to 20 |
| Précision (TDS) | ± 1% full scale |
| Gamme (conductivité) | 0 to 500 mS |
| Précision (salinité) | ± 1% full scale |
Fisherbrand™ Traceable™ Portable Dissolved Oxygen Meter
Traceable™ Portable Dissolved Oxygen Meter is traceable to NIST™ standards.
Fisherbrand™ accumet™ AP125 Portable pH/Ion/mV/Temperature Meter Kit
Accurate measurements any time, anywhere
Fisherbrand™ accumet™ Basic AB330 Benchtop Laboratory Conductivity Meter
Ideal for daily conductivity, TDS and salinity testing of your routine laboratory samples, the accumet™ Basic AB330 Benchtop Meter provides essential functions needed without complicated functions at a budget-friendly price.
| Compensation thermique | Linear |
|---|---|
| Garantie | 3 Years |
| Adaptateur secteur | Universal Power Adapter |
| Résolution (TDS) | 0.01, 0.1, 1 ppm; 0.01, 0.1 ppt |
| Measurement Modes | Conductivity with Temperature,TDS with Temperature,Salinity with Temperature |
| Points d’étalonnage (conductivité) | 84 μS, 1413 μS, 12.88 mS, 111.8 mS |
| Modèle | AB330 |
| Option de rétro-éclairage | Yes |
| Gamme (salinité) | 0 to 80 ppt |
| Fréquence | 50/60 Hz |
| Sorties | Port for Computer or Printer |
| Stabilité | Indicator Icons |
| Détails de la gestion des données | Printed or CSV Format |
| Indice IP | IP54 |
| Gamme de facteurs TDS | 0.4 to 1 |
| Tension | 100/240 V |
| Coefficient thermique | 0 to 10 %/°C |
| Points de données | 500 |
| Précision (conductivité) | ±1% Full Scale |
| Constante de cellule | 0.1 to 10 |
| Résolution (salinité) | 0.01, 0.1 ppt |
| Précision (température) | ±0.3°C (±0.5°F) |
| Points d’étalonnage | 1 to 5 (Conductivity), 1 to 5 (TDS), 1 (Salinity), 1 (Temperature) |
| Entrées | Conductivity, ATC |
| Étalonnage | Conductivity, TDS, Salinity, Temperature |
| Température (métrique) de référence | 15, 20, 25 or 30°C |
| Enregistrement des données | Automatic with Auto-read and Timed Modes, Manual with Continuous Mode |
| Type d’affichage | 5 in. LCD |
| Résolution (conductivité) | 0.01, 0.1, 1 μS; 0.01, 0.1 mS |
| Mémoire | Non-volatile |
| Plage de températures (métrique) | -5°C to +105°C |
| Précision (TDS) | ±1% Full Scale |
| Résolution (température) | 0.1°C (0.1°F) |
| Précision (salinité) | ±1% Full Scale |
| Gamme (conductivité) | 0 μS to 500 mS |
Fisherbrand™ Traceable™ Dual-Display Conductivity Meter
Measures conductivity and temperature; includes NIST™ traceability certificate.
Thermo Scientific™ Elite CTS Conductivity / TDS / Salinity Pin-sensor Pocket Testers and Replacement Sensors
Flexible on-the-go conductivity, TDS, salinity and temperature testing using durable Elite CTS pin-sensor pocket testers for a variety of applications including hydroponics, pools, spas and more!
| Compensation thermique | Yes |
|---|---|
| Résolution de la température | 0.1°C, 0.1°F |
| Étalonnage de la sonde de température | 1 point |
| Résolution (salinité) | 0.10 ppt |
| Gamme (TDS) | 0.00 to 10.00 ppt |
| Résolution (TDS) | 0.1 ppm for 0.0 to 100.0 ppm; 1 ppm for 100 to 1000 ppm; 0.01 ppt for 0.10 to 10.00 ppt |
| Measurement Modes | Conductivity,TDS,Salinity,Temperature |
| Points d’étalonnage (conductivité) | 1 to 3 |
| Modes de mesure de la salinité | Per practical salinity curve |
| Résolution (conductivité) | 0.1 μS/cm for 0.0 to 200.0 μS/cm; 1 μS/cm for200 to 2000 μS/cm; 0.01 mS/cm for 2.00 to 20.00 mS/cm |
| Gamme (salinité) | 0.00 to 10.00 ppt |
| Température (métrique) en fonctionnement | 5°C to 45°C (ambient) |
| Gamme de facteurs TDS | 0.40 to 1.00 (selectable) |
| Gamme d’humidité relative | 5 to 85 %, non-condensing |
| Précision de la température | ±0.6°C, ±1.0°F for 0.0 to 50.0°C; ±1.1°C, ±1.9°F for 50.1 to 60.0°C |
| Précision (TDS) | ± 1% full scale |
| Plage de températures (impériale) | 32.0°F to 140.0°F |
| Gamme (conductivité) | 0.00 to 20.00 mS/cm |
| Précision (salinité) | ± 1% full scale |
| Précision (conductivité) | ± 1% full scale |
Mettler Toledo™ Seven2Go S7 Conductivity Meter
The Seven2Go portables are engineered to provide users with fast quality data, one-handed operation, and durability, making them ideally suited for mobile applications in the laboratory, at-line, and outdoors.
| Certifications/Conformité | ISO 9001:2000 |
|---|---|
| Compensation thermique | Automatic or Manual |
| Dimensions (L x l x H) | 222 x 70 x 35 mm |
| Résolution (TDS) | 0.01 to 1 |
| Measurement Modes | Conductivity |
| Canaux | 1 |
| Modèle | Single channel; conductivity, TDS, salinity |
| Gamme (salinité) | 0.00 to 42 psu |
| Type de batterie | 4 x 1.5 V AA or 1.3 V NiMH acc. |
| Indice IP | IP67 |
| Gamme (résistivité) | 0.00 to 100.0 Mohm/cm |
| Poids (métrique) | 290 g |
| Précision (conductivité) | ±0.5% |
| Constante de cellule | Manual entry |
| Résolution (salinité) | 0.01 to 0.1 |
| Gamme (TDS) | 0.01 mg/L to 600 g/L |
| Points d’étalonnage | 1 |
| Entrées | LTW 7-pin (sensor) |
| Résolution (conductivité) | 0.01 |
| Type d’affichage | Color Graphic |
| Plage de températures (métrique) | -5°C to +105°C |
| Autonomie de la batterie | 200 to 250 hr. |
| Gamme (pH) | 0 to 14 |
| Précision (TDS) | ±0.5% |
| Gamme (conductivité) | 0.01 μS/cm to 1000 mS/cm |
| Précision (salinité) | ±0.5% |
Thermo Scientific™ Orion Star™ A123 Dissolved Oxygen Portable Meter
Take simple dissolved oxygen and temperature measurements with this portable meter with easy operation for basic field testing.
| Certifications/Conformité | CE, TUV 3-1, FCC Class A |
|---|---|
| Clavier | Simple with highlighted measure key, scroll and shortcut keys |
| Sélection de la température | Automatic with ATC temperature probe |
| Correction de la pression barométrique | 450 to 850mmHg, automatic with manual entry |
| Garantie | 3 Year Meter Warranty |
| Dimensions (L x l x H) | 24 cm x 10 cm x 6.5 cm (9.5 in. x 3.9 in. x 2.6 in.) |
| Adaptateur secteur | Universal 50-60 Hz, 100-240 VAC power adapter (sold separately, Cat. No. 1010003) |
| Précision (OD par mesure polarographique) | ±0.2mg/L or ±2% of reading, whichever is greater |
| Measurement Modes | Dissolved Oxygen (% Saturation),Dissolved Oxygen (mg/L with Temperature) |
| Canaux | 1 |
| Langues | English |
| Type de batterie | Four AA (included) |
| Température (impériale) en fonctionnement | 41°F to 113°F (ambient) |
| Sorties | None |
| Stabilité | Smart Stability and Smart Averaging |
| Détails de la gestion des données | Internal data point memory |
| Indice IP | IP-67 |
| Gamme (OD par mesure polarographique) | 0.00 to 20.00 mg/L |
| Percent Saturation Relative Accuracy (Polarographic DO) | ±2 % saturation or ±2% of reading whichever is greater |
| Types de capteur | Polarographic Dissolved Oxygen Sensor |
| Points de données | 50 |
| Poids (métrique) | 0.5 kg |
| Gamme de pression | 450 to 850mmHg (manual entry) |
| Étalonnage de la sonde de température | 1 point temperature offset calibration |
| Type de fonction d’enregistrement | Automatic with Auto-Read Measure Mode, Manual with Continuous Measure Mode |
| Percent Saturation Range Polarographic DO | 0.0 to 200.0 % saturation |
| Précision (température) | ±0.1°C |
| Modes d’étalonnage | Water-saturated air, manual (Winkler titration) |
| Résolution (OD par mesure polarographique) | 0.01, 0.1mg/L |
| Entrées | 9 pin MiniDIN (polarographic DO sensor with built-in temperature) |
| Type d’affichage | LCD |
| Alimentation électrique | 4 AA batteries (included) or universal AC adapter (sold separately) |
| Mémoire | Non-volatile memory preserves log and settings |
| Plage (métrique) de températures | 0.0°C to 50.0°C |
| Température (métrique) en fonctionnement | 5°C to 45°C (ambient) |
| Percent Saturation Resolution (Polarographic DO) | 0.1, 1 % saturation |
| Poids (impériale) | 2 lb. |
| Autonomie de la batterie | 2000 hours |
| Gamme d’humidité relative | 5 to 85 %, non-condensing |
| Facteur de salinité | 0 to 45 ppt, automatic correction using manual entry of sample salinity |
| Résolution (température) | 0.1°C (0.1°F) |
| Percent Saturation Range (Polarographic DO) | 0.0 to 200.0 % saturation |