HPLC Columns
- (4)
- (10)
- (7)
- (1)
- (5)
- (13)
- (1)
- (62)
- (1)
- (2)
- (15)
- (70)
- (10)
- (2)
- (2)
- (1)
- (2)
- (1)
- (113)
- (978)
- (3)
- (43)
- (1)
- (28)
- (20)
- (4)
- (11)
- (2)
- (622)
- (16)
- (2)
- (28)
- (14)
- (4)
- (293)
- (16)
- (1,256)
- (2)
- (7)
- (1)
- (7)
- (7)
- (35)
- (9)
- (30)
- (9)
- (100)
- (1)
- (8)
- (9)
- (6)
- (11)
- (5)
- (322)
- (174)
- (343)
- (7)
- (1)
- (1)
- (63)
- (1)
- (491)
- (431)
- (1)
- (55)
- (1)
- (2)
- (12)
- (12)
- (1)
- (381)
- (12)
- (333)
- (126)
- (1)
- (21)
- (156)
- (1)
- (53)
- (19)
- (1)
- (2)
- (10)
- (4)
- (2)
- (12)
- (15)
- (2)
- (315)
- (17)
- (305)
- (10)
- (1)
- (3)
- (15)
- (2)
- (3)
- (129)
- (1)
- (6)
- (2)
- (2)
- (3)
- (31)
- (5)
- (70)
- (322)
- (7)
- (1)
- (33)
- (3)
- (13)
- (156)
- (25)
- (15)
- (7)
- (14)
- (133)
- (412)
- (61)
- (704)
- (30)
- (21)
- (5)
- (68)
- (24)
- (1,542)
- (3)
- (5)
- (22)
- (17)
- (17)
- (24)
- (4)
- (1)
- (1)
- (4)
- (543)
- (1)
- (1)
- (3)
- (456)
- (10)
- (1)
- (499)
- (18)
- (57)
- (2)
- (11)
- (2)
- (23)
- (2)
- (5)
- (82)
- (2)
- (11)
- (150)
- (241)
- (46)
- (38)
- (5)
- (70)
- (58)
- (3)
- (42)
- (5)
- (142)
- (2)
- (11)
- (16)
- (7)
- (11)
- (46)
- (3)
- (5)
- (127)
- (1)
- (1)
- (509)
- (22)
- (201)
- (6)
- (8)
- (4)
- (64)
- (84)
- (411)
- (41)
- (63)
- (11)
- (28)
- (104)
- (11)
- (2)
- (12)
- (40)
- (27)
- (12)
- (1)
- (31)
- (1)
- (2)
- (45)
- (2,210)
- (30)
- (11)
- (1)
- (9)
- (8)
- (10)
- (52)
- (6)
- (2)
- (4)
- (126)
- (1)
- (1)
- (9)
Filtered Search Results
Thermo Scientific™ Acclaim™ Trinity Q1 LC Columns
Greener Choice
Offers one or more environmental benefits itemized in the U.S. FTC Green Guides.
Learn More
Offers one or more environmental benefits itemized in the U.S. FTC Green Guides.
Learn More
Use to separate the herbicides diquat and paraquat.
| Green Features | FSC |
|---|---|
| Product Line | Acclaim |
Thermo Scientific™ BetaSil™ Phenyl HPLC Columns, 3μm Particle Size
Thermo ScientificTM BetaSilTM Phenyl HPLC Columns are available in limited dimensions. Please contact Customer Service for more details.
| Pore Size | 100 Å |
|---|---|
| Particle Size | 3 μm |
| Carbon Load | 11% |
| Stationary Phase | Phenyl (Ph) |
| Phase | Reversed Phase |
| For Use With | LC/MS |
| Endcapped | Yes |
| Packing Material | Silica |
| Column Type | Reversed Phase |
| pH | 2 to 9 |
| USP Type | L11 |
TSKgel™ UP-SW3000 HPLC Column, 2 μm Particle Size, Sold by MilliporeSigma™ Supelco™
TSKgel™ UP-SW3000 columns deliver dramatically increased resolution between fragments, monomers, and aggregates.
| Pore Size | 250 Å |
|---|---|
| Particle Size | 2 μm |
| Solvents | 0 to 30% aqueous soluble organic solvents |
| Flow Rate | 0.35 mL/min. |
| Stationary Phase | Diol |
| Temperature | 10°C to 30°C |
| Phase | Size Exclusion |
| Matrix | Silica Particle Platform |
| Diameter (Metric) | 4.6 mm |
| pH | 2.5 - 7.5 |
| Max. Pressure | 340 bar |
| Product Line | TSKgel |
| USP Type | L20, L59 |
Thermo Scientific™ Accucore™ XL C8 HPLC Columns
Improve laboratory productivity using Thermo Scientific™ Accucore™ XL C8 Columns.
| Pore Size | 80 Å |
|---|---|
| Particle Size | 4 μm |
| Carbon Load | 4% |
| Stationary Phase | C8 |
| Temperature | 60°C |
| Phase | Reversed Phase |
| Endcapped | Yes |
| pH | 2 to 9 |
| Surface Area | 90 m²/g |
| Max. Pressure | 8700 psi (600 bar) |
| USP Type | L7 |
TSKgel™ SuperHZ3000 HPLC Column, 3 μm Particle Size, Sold by MilliporeSigma™ Supelco™
TSKgel SuperHZ3000 Columns are packed with rigid, porous, polymer beads. They are used for the non-aqueous separation of solvent-soluble small molecules and oligomers less than 60,000 Da.
| Pore Size | 75 Å |
|---|---|
| Particle Size | 3 μm |
| Stationary Phase | Polystyrene-divinylbenzene |
| Temperature | 60°C |
| Matrix | Polystyrene-divinylbenzene Phase/Polymer Particle Platform |
| Length (Metric) | 15 cm |
| Material | Stainless Steel Hardware |
| Technique | SEC |
| Max. Pressure | 30 bar |
| Product Line | TSKgel |
Thermo Scientific™ Accucore™ PFP HPLC Columns
Use these solid core particle columns to analyze difficult-to-resolve mixtures including DOA and pharmaceuticals.
| Pore Size | 80 Å |
|---|---|
| Particle Size | 2.6 μm |
| Carbon Load | 5% |
| Stationary Phase | PFP |
| Temperature | 70°C |
| Phase | Reversed Phase |
| Endcapped | Yes |
| Packing Material | Ultrapure Silica |
| pH | 2 to 8 |
| Surface Area | 130 m²/g |
| Max. Pressure | 14500 psi (1000 bar) |
| Product Line | Accucore |
| USP Type | L43 |
MilliporeSigma™ Supelco™ Kromasil™ Eternity™ C18 HPLC Column, 100 Å, 5 μm Particle Size
Kromasil™ Eternity™ and Eternity™XT can be used in a wider pH window than regular silica-based HPLC materials, giving more flexibility than ever when running analytical applications or optimizing for large-scale applications.
| Pore Size | 100 Å |
|---|---|
| Particle Size | 5 μm |
| Stationary Phase | C18 (octadecyl) |
| Phase | Reversed Phase |
| Matrix | C18 (octadecyl) Phase |
| Surface Area | 330 m2/g |
| Product Line | Kromasil Eternity |
Thermo Scientific™ Hypersil™ BDS Cyano HPLC Columns
For reliable, general purpose cyano columns, choose the base-deactivated silica Thermo Scientific™ Hypersil™ BDS Cyano LC Columns.
| Pore Size | 130 Å |
|---|---|
| Carbon Load | 4% |
| Stationary Phase | Cyano (CN) |
| Temperature | 60°C |
| Endcapped | Yes |
| Column Type | Mixed Mode |
| Surface Area | 170 m²/g |
| Max. Pressure | 5800 psi (400 bar) |
| USP Type | L10 |
MilliporeSigma™ Supelco™ ChromegaChiral™ Chiral CCA HPLC Column, 10 μm Particle Size
A polysaccharide coated chiral stationary phase and columns which are produced using a unique production process of coating the proven chiral selector, tris-(3,5-di- methylphenyl) carbamoyl amylose on high purity silica gel.
| Pore Size | 1000 Å |
|---|---|
| Particle Size | 10 μm |
| Stationary Phase | carbamoyl |
| Phase | Chiral |
| Matrix | carbamoyl Phase |
| Technique | Chiral HPLC |
| Product Line | ChromegaChiral |
Thermo Scientific™ MAbPac™ HIC-20 HPLC Columns
Greener Choice
Offers one or more environmental benefits itemized in the U.S. FTC Green Guides.
Learn More
Offers one or more environmental benefits itemized in the U.S. FTC Green Guides.
Learn More
Use this column to separate monoclonal antibodies (mAbs), mAb fragments and oxidized variants by hydrophobic interaction chromatography (HIC).
| Pore Size | 1000 Å |
|---|---|
| Particle Size | 5 μm |
| Temperature | 60°C |
| Phase | Hydrophobic Interaction |
| Packing Material | Spherical, High Purity Silica |
| pH | 2 to 9 |
| Product Line | MAbPac |
TSKgel™ G6000PWXL-CP HPLC Column, 13 μm Particle Size, Sold by MilliporeSigma™ Supelco™
TSKgel PWXL-CP columns were specifically developed for the analysis of water-soluble cationic polymers. Composed of polymethacrylate beads, cationic groups are introduced on the surface of the packing material to prevent adsorption of cationic polymers and allow elution under low salt conditions.
TSKgel™ Amide-80 HPLC Column, 5 μm Particle Size, Sold by MilliporeSigma™ Supelco™
TSKgel™ Amide-80 columns are used for the analysis of saccharides, glycans, oligosaccharides, peptides and polar compounds from natural products.
MilliporeSigma™ Supelco™ SUPELCOSIL™ LC-Diol HPLC Column, 5 μm Particle Size
LC-Diol columns can be used to separate proteins by gel filtration chromatography.
| Pore Size | 120 Å |
|---|---|
| Particle Size | 5 μm |
| Stationary Phase | Diol |
| Phase | Reversed Phase |
| Matrix | Diol Phase/Silica Gel, Spherical Particle Platform |
| Length (Metric) | 25 cm |
| Endcapped | No |
| Surface Area | 170 m2/g |
| Product Line | SUPELCOSIL |
MilliporeSigma™ Supelco™ SUPELCOSIL™ LC-NH2 HPLC Column, 5 μm Particle Size
The amino column is most often employed for the separation of mono- and disaccharides.
| Pore Size | 120 Å |
|---|---|
| Particle Size | 5 μm |
| Stationary Phase | Amino (NH2) |
| Phase | Reversed Phase |
| Matrix | Amino (NH2) Phase/Silica Gel, Spherical Particle Platform |
| Length (Metric) | 25 cm |
| Endcapped | Yes |
| Surface Area | 170 m2/g |
| Product Line | SUPELCOSIL |
MilliporeSigma™ Supelco™ Ascentis™ Express C8 HPLC Column, 2.7 μm Particle Size
Ascentis™ Express HPLC columns, through the use of Fused-Core™ particle technology, can provide you with both the high speed and high efficiencies of sub-2 μm particles while maintaining lower backpressures.
| Pore Size | 90 Å |
|---|---|
| Particle Size | 2.7 μm |
| Stationary Phase | C8 (Octyl) |
| Phase | Reversed Phase |
| Matrix | C8 (Octyl) Phase/Fused-Core Particle Platform |
| Endcapped | Yes |
| pH | 2 to 9 |
| Technique | Fused-Core HPLC |
| Product Line | Ascentis |