Real Time PCR Products
Filtered Search Results
Applied Biosystems™ TaqPath™ BactoPure™ Microbial Detection Master Mix, no Rox
TaqPath™ BactoPure™ Microbial Detection Master Mix is optimized for rapid low-level microbial detection even in the presence of PCR inhibitors. Does not contain a passive reference, recommended for use with assays utilizing JUN dye or higher order multiplexing (> three targets).
| InhibitorToleranceSimple | Very High |
|---|---|
| For Use With (Application) | Microbial Detection |
| PCR Method | qPCR |
| Multiplex Capability | Up to 4-plex |
| Detection Method | Primer-probe |
| Includes | dUTP, UNG/UDG |
| Thermostability | 72 hr., Assembled Reaction |
| Sensitivity | Down to 1 copy |
| Passive Reference Dye | None |
| For Use With (Equipment) | 7500 Fast System, 7500 System, 7900HT Fast System, 7900HT System, QuantStudio™ 12k Flex Dx, QuantStudio™ 12k Flex, QuantStudio™ 3, QuantStudio™ 5, QuantStudio 5 Dx, QuantStudio 6 Pro, QuantStudio™ 6 Flex, QuantStudio™ 7 Flex, QuantStudio 7 Pro, QuantStudio 7 Pro Dx, ViiA™ 7 System, ViiA 7 Dx, QuantStudio™ Dx, StepOnePlus™ System, 7500 Fast Dx System, StepOne™ System |
| Sample Type | DNA |
| Reaction Speed | Fast or Standard |
| Target Specificity | cDNA or gDNA only |
| Product Line | TaqPath |
Applied Biosystems™ TaqPath™ 1-Step RT-qPCR Master Mix, CG
TaqPath 1-Step RT-qPCR Master Mix, CG, is designed for robust and reproducible one-step pathogen detection and gene expression workflows. The single-tube 4X formulation contains thermostable MMLV reverse transcriptase, dNTPs, UNG, ROX dye, and thermostable Fast DNA polymerase.
| Reverse Transcriptase | M-MLV |
|---|---|
| Form | Liquid |
| InhibitorToleranceSimple | High |
| Concentration | 4X |
| For Use With (Application) | Microbial Detection,DNA Quantification,Presence/Absence |
| PCR Method | 1-step RT-qPCR |
| Multiplex Capability | Up to 3-plex |
| Detection Method | Primer-probe |
| Includes | dUTP, UNG/UDG |
| Thermostability | Not Applicable |
| Polymerase | Fast DNA Polymerase |
| Sensitivity | Down to 10 copies |
| Passive Reference Dye | ROX (Pre-mixed) |
| For Use With (Equipment) | 7500 Fast System, 7500 System, 7900HT System, QuantStudio™ 12k Flex, QuantStudio™ 3, QuantStudio™ 5, QuantStudio™ 6 Flex, QuantStudio™ 7, StepOne™, StepOnePlus™, ViiA™ 7 System, 7500 Fast Dx System, QuantStudio™ Dx |
| Sample Type | RNA, cDNA, DNA |
| Reaction Speed | Fast or Standard |
| Target Specificity | RNA only, Both RNA and DNA |
| Hot Start | Built-In Hot Start |
| Product Line | TaqPath |
Applied Biosystems™ TaqMan™ Fast Virus 1-Step Master Mix for qPCR
TaqMan Fast Virus 1-Step Master Mix is designed for fast, highly sensitive real-time RT-PCR, even in the presence of challenging PCR inhibitors.
| Shipping Condition | Dry Ice |
|---|---|
| Reverse Transcriptase | M-MLV |
| Form | Liquid |
| InhibitorToleranceSimple | High |
| For Use With (Application) | Microbial Detection,Gene Expression,DNA Quantification,Presence/Absence |
| PCR Method | 1-step RT-qPCR |
| Multiplex Capability | Up to 3-plex |
| Detection Method | Primer-probe |
| Thermostability | Not Applicable |
| Polymerase | AmpliTaq Fast DNA Polymerase |
| Format | Tube |
| Product Type | 1-Step Master Mix |
| Passive Reference Dye | ROX (Pre-mixed) |
| For Use With (Equipment) | 7500 Fast System, 7500 System, 7900HT System, QuantStudio 12k Flex, QuantStudio 3, QuantStudio 5, QuantStudio 6 Flex, QuantStudio 6 Pro, QuantStudio 7 Pro, QuantStudio 7 Flex, StepOne, StepOnePlus, ViiA 7 System |
| Sample Type | Total RNA, Viral DNA, Viral RNA, mRNA |
| Reaction Speed | Fast or Standard |
| Target Specificity | RNA only, Both RNA and DNA |
| Hot Start | Built-In Hot Start |
| Product Line | TaqMan |
Applied Biosystems™ TaqMan™ Universal Master Mix II, no UNG
TaqMan Universal Master Mix II is a convenient mix of components (except primers, probes, template, and water) necessary to perform a real-time polymerase chain reaction (PCR).
| GC-Rich PCR Performance | High |
|---|---|
| Content And Storage | Store at 2°C to 8°C in the dark. Guaranteed minimum shelf life is 60 days (exact expiry date printed on product and CofA). |
| Fidelity (vs. Taq) | 2 X |
| Purity or Quality Grade | UP (Ultra Pure) |
| Concentration | 2X |
| For Use With (Application) | Gene Expression,Genotyping,miRNA analysis |
| PCR Method | qPCR |
| Detection Method | Primer-probe |
| Polymerase | AmpliTaq Gold DNA Polymerase |
| Product Type | Universal Master Mix II |
| Passive Reference Dye | ROX (Pre-mixed) |
| For Use With (Equipment) | 7300 System, 7500 System, 7900HT System,Applied Biosystems StepOnePlus™ Fast Real-Time PCR System, StepOne™, Standard Mode, StepOnePlus™, Standard Mode, ViiA™ 7 System |
| Sample Type | DNA (Genomic), cDNA |
| Reaction Speed | Standard |
| Product Line | TaqMan |
Applied Biosystems™ SYBR™ Select Master Mix for CFX
A cost-effective solution for real-time PCR applications.
| GC-Rich PCR Performance | High |
|---|---|
| Purity or Quality Grade | UP (Ultra Pure) |
| Form | Liquid |
| Concentration | 2X |
| For Use With (Application) | Gene Expression |
| PCR Method | qPCR |
| Detection Method | SYBR |
| Polymerase | AmpliTaq DNA Polymerase |
| Format | Vial |
| Product Type | Real Time PCR SYBR Master Mix |
| Passive Reference Dye | ROX (Pre-mixed) |
| For Use With (Equipment) | AB 7900HT, Standard Mode, AB StepOne™, Fast Mode, AB 7500, Standard Mode, AB 7500, Fast Mode, Bio-Rad CFX96 Touch™, AB StepOnePlus™, Fast Mode, AB 7900HT, Fast Mode, AB StepOne™, Standard Mode, Bio-Rad CFX Connect™, AB 7900 HT 384-Well System, Bio-Rad CFX384 Touch™, AB StepOnePlus™, Standard Mode |
| Sample Type | DNA (Genomic), cDNA |
| Reaction Speed | Fast or Standard |
| Label or Dye | SYBR GreenER |
| Hot Start | Built-In Hot Start |
| Product Line | SYBR |
Applied Biosystems™ TaqPath™ ProAmp™ Multiplex Master Mix
TaqPath ProAmp Multiplex Master Mix is for higher multiplexing (up to four targets) in high-throughput genotyping and copy number variation protocols requiring uncompromising reliability and accuracy, even in the presence of inhibitors commonly found in clinical samples.
| Shipping Condition | Wet Ice |
|---|---|
| Content And Storage | Store at 2°C to 8°C in the dark. |
| InhibitorToleranceSimple | Very High |
| For Use With (Application) | Genotyping,Pharmacogenomics |
| PCR Method | qPCR |
| Multiplex Capability | Up to 4-plex |
| Detection Method | Primer-probe |
| Includes | dUTP, UNG/UDG |
| Thermostability | 72 hr., Assembled Reaction |
| Polymerase | Taq DNA Polymerase |
| Product Type | qPCR Master Mix |
| Passive Reference Dye | Mustang Purple |
| For Use With (Equipment) | QuantStudio 3 or 5, QuantStudio 6/QuantStudio 7 Flex, QuantStudio 12K Flex, QuantStudio Dx, ViiA 7 Real-Time PCR System ViiA 7 Dx, 7500 Fast, StepOne or StepOnePlus |
| Reaction Speed | Fast or Standard |
| Target Specificity | cDNA or gDNA only |
| Product Line | TaqPath |
Applied Biosystems™ Power SYBR™ Green PCR Master Mix
Offers superior sensitivity and reproducibility, detecting as few as two copies of a target gene over a broad range of template concentrations.
| GC-Rich PCR Performance | High |
|---|---|
| Purity or Quality Grade | LD (Low DNA) |
| Concentration | 2X |
| For Use With (Application) | Gene Expression |
| PCR Method | qPCR |
| Detection Method | SYBR |
| Polymerase | AmpliTaq Gold DNA Polymerase, AmpliTaq Gold LD |
| Product Type | Real Time PCR SYBR Master Mix |
| Passive Reference Dye | ROX (Pre-mixed) |
| For Use With (Equipment) | 7300 System, 7500 System, 7700 System, 7900HT Fast System,Applied Biosystems StepOnePlus™ Fast Real-Time PCR System, QuantStudio™ 12k Flex, QuantStudio™ 3, QuantStudio™ 5, QuantStudio™ 6 Flex, QuantStudio™ 7, StepOne™, Standard Mode, StepOnePlus™, Standard Mode, ViiA™ 7 System |
| Sample Type | DNA (Genomic), cDNA |
| Reaction Speed | Standard |
| Label or Dye | SYBR Green |
| Product Line | SYBR |
Invitrogen™ Platinum™ Quantitative PCR SuperMix-UDG w/ROX
qPCR SuperMixes with ROX for ABI instruments are ready-to-use reaction mixes for high-specificity, real-time amplification of cDNA, genomic DNA or plasmid DNA.
| Shipping Condition | Dry Ice |
|---|---|
| Polymerase | Platinum Taq DNA Polymerase |
| GC-Rich PCR Performance | High |
| Fidelity (vs. Taq) | 2 X |
| Product Type | Quantitative PCR SuperMix-UDG |
| For Use With (Equipment) | 7000 System, 7300 System, 7700 System, 7900HT System |
| Sample Type | DNA (Genomic), cDNA |
| Reaction Speed | Standard |
| Concentration | 2X |
| For Use With (Application) | Gene Expression |
| PCR Method | qPCR |
| Product Line | Platinum |
| Detection Method | Primer-probe |
Invitrogen™ EXPRESS qPCR Supermix, with premixed ROX
EXPRESS qPCR SuperMix kits are compatible with fast-cycling instruments for your probe-based qPCR assays.
| GC-Rich PCR Performance | High |
|---|---|
| Content And Storage | EXPRESS qPCR SuperMix kits are provided as a 2X qPCR SuperMix with ROX premixed or in a separate tube. Store at -20°C upon receipt. Once thawed, the EXPRESS qPCR SuperMix can be stored for up to 1 month at +4·C. Product is guaranteedstable for 6 months when properly stored. Guaranteed minimum shelf life is 60 days (exact expiry date printed on product and CofA). |
| Format | Tube |
| Product Type | Express qPCR Supermix |
| For Use With (Equipment) | 7000 System, 7300 System, 7700 System, 7900HT Fast System, 7900HT System, Eppendorf™ MasterCycler™ RealPlex, StepOne™, Fast Mode, StepOne™, Standard Mode |
| Sample Type | DNA (Genomic), cDNA |
| Reaction Speed | Fast or Standard |
| For Use With (Application) | Gene Expression |
| PCR Method | qPCR |
| Detection Method | Primer-probe |
Applied Biosystems™ TaqMan™ Universal Master Mix II, with UNG
TaqMan Universal Master Mix II is a convenient mix of components (except primers, probes, template, and water) necessary to perform a real-time polymerase chain reaction (PCR).
| GC-Rich PCR Performance | High |
|---|---|
| Content And Storage | Store at 2°C to 8°C in the dark. Guaranteed minimum shelf life is 60 days (exact expiry date printed on product and CofA). |
| Fidelity (vs. Taq) | 2 X |
| Purity or Quality Grade | UP (Ultra Pure) |
| Concentration | 2X |
| For Use With (Application) | Gene Expression,Genotyping,miRNA analysis |
| PCR Method | qPCR |
| Detection Method | Primer-probe |
| Polymerase | AmpliTaq Gold DNA Polymerase |
| Product Type | Universal Master Mix II |
| Passive Reference Dye | ROX (Pre-mixed) |
| For Use With (Equipment) | 7300 System, 7500 System, 7900HT System,Applied Biosystems StepOnePlus™ Fast Real-Time PCR System, StepOne™, Standard Mode, StepOnePlus™, Standard Mode, ViiA™ 7 System |
| Sample Type | DNA (Genomic), cDNA |
| Reaction Speed | Standard |
| Product Line | TaqMan |
Applied Biosystems™ TaqMan™ Environmental Master Mix 2.0
Accurate, real-time PCR-based pathogen detection in the presence of high levels of inhibitors.
| Purity or Quality Grade | UP (Ultra Pure) |
|---|---|
| Concentration | 2X |
| For Use With (Application) | Gene Expression,Genotyping,Pathogen Detection,Virus Detection |
| PCR Method | qPCR |
| Detection Method | Primer-probe |
| Polymerase | AmpliTaq Gold DNA Polymerase |
| Format | Bottle |
| Product Type | qPCR Master Mix |
| Passive Reference Dye | ROX (Pre-mixed) |
| For Use With (Equipment) | 7000 System, 7300 System, 7500 Fast System, 7500 System, 7900HT Fast System, 7900HT System, StepOne™, Standard Mode |
| Sample Type | Environmental Sample, Food |
| Reaction Speed | Standard |
| Hot Start | Built-In Hot Start |
| Product Line | TaqMan |
Thermo Scientific™ Maxima Probe qPCR Master Mixes
Optimize qPCR with probe chemistry using standard cycling protocols with these ready-to-use qPCR master mixes.
Applied Biosystems™ VetMAX™-Plus qPCR Master Mix
For use with VetMAX™ Reagents and VetMAX™ Controls.
Applied Biosystems™ Absolute Q™ Universal DNA Digital PCR Master Mix (5X)
Absolute Q Universal DNA Digital PCR Master Mix is compatible with a broad range of applications and over 20 million Applied Biosystems predesigned TaqMan Assays, eliminating the need to design custom assays.
Applied Biosystems™ PowerUp™ SYBR™ Green & Endura™ 384-well Plates Bundle
Bundle and save up to 50% off PowerUp SYBR Green Master Mix and Plates