Thermo Scientific™ Pierce™ 6 Protein Digest, equimolar, LC-MS grade
Calibrate and maintain quality control for mass spectrometry (MS) analysis of proteomic samples using the Thermo Scientific™ Pierce™ 6 Protein Digest Standard, Equimolar, LC-MS Grade, a highly validated equimolar protein digest mixture.
Thermo Scientific™ Pierce™ LTQ Velos ESI Positive Ion Calibration Solution
Calibrate LTQ Velos, LTQ Orbitrap and other mass spectrometers using a mixture of highly purified ionizable molecules designed for positive mode calibration.
Thermo Scientific™ Pierce™ BSA Protein Digest, MS grade
Calibrate and maintain quality control for liquid chromatography (LC) and mass spectrometry (MS) analysis of proteomic samples using the carefully validated Thermo Scientific™ Pierce™ BSA Protein Digest Standard, LC-MS Grade.
Thermo Scientific™ SureQuant™ IP-MS Sample Preparation Kits
Thermo Scientific SureQuant IP-MS Sample Preparation Kits provide an optimized solution for the immunoprecipitation and MS peptide preparation of samples upstream of LC-MS/MS analysis.
| Content And Storage | Store trypsin at 4°C. Store trypsin storage solution at -20°C. |
|---|---|
| Workflow Step | Sample prep enrichment |
| For Use With (Equipment) | Mass spectrometer |
| Quantity | 20 Reactions |
| For Use With (Application) | MS-compatible immunoprecipitation |
| Starting Material | Cells,Tissue |
| Detection Method | Mass Spectrometry |
| Product Line | SureQuant |
Thermo Scientific™ Pierce™ Peptide Retention Time Calibration Mixture
15 synthetic heavy peptides mixed in equimolar ratio to test and calibrate reverse-phase liquid chromatography (LC) and mass spectrometry (LC-MS) equipment.
Thermo Scientific™ Pierce™ Reserpine Standard for LC-MS
An exact solution of reserpine specifically designed for performance evaluation of mass spectrometers, including the Thermo Scientific™ ion trap and TSQ series of instruments.
Thermo Scientific™ Pierce™ HeLa Protein Digest Standard
Use this standard, a highly validated mammalian protein digest, as a quality control sample for mass spectrometry (MS) analysis of complex proteomic samples.
| Form | Solid |
|---|---|
| Final Product Type | Peptides |
| Product Type | Protein Digest Standard |
| For Use With (Equipment) | Mass Spectrometer |
| Reagent Type | Standard |
| Starting Material | Peptides |
| Detection Method | Mass Spectrometry |
| Product Line | Pierce |
Thermo Scientific™ 96-Well Plates for Pierce™ Quantitative Fluorometric Peptide Assay
Measure total peptide concentration by a mix-and-read fluorescent microplate method that provides improved sensitivity, reproducibility, and ease using the Thermo Scientific™ Pierce™ Quantitative Fluorescent Peptide Assay.
Thermo Scientific™ Pierce™ Quantitative Peptide Assays & Standards
Pierce colorimetric or fluorescent quantitative peptide assays and standards are easy-to-use microplate assays designed specifically to improve the sensitivity and reproducibility of peptide quantitation for use with mass spectrometry analysis.
| Workflow Step | In-Process Testing |
|---|---|
| For Use With (Equipment) | Microplate Reader |
| Starting Material | Peptides,Protease-digested Protein |
| Product Line | Pierce |
Thermo Scientific™ Pierce™ High pH Reversed-Phase Peptide Fractionation Kit
Increase protein identification from LC/MS analysis through orthogonal peptide fractionation of complex peptide samples using Thermo Scientific™ Pierce™ High pH Reversed-Phase Peptide Fractionation Kit.
Thermo Scientific™ Pierce™ Peptide Desalting Spin Columns
Pierce Peptide Desalting Spin Columns provide a convenient and reproducible way to desalt and remove contaminants from peptide samples prior to analysis by mass spectrometry.
| Shipping Condition | Room Temperature |
|---|---|
| Content And Storage | Store at 2–8°C. |
| Format | Spin Column |
| Final Product Type | Peptide |
| Product Type | Spin Desalting Column |
| Detection Method | Mass Spectrometry |
| Product Line | Pierce |
Thermo Scientific™ Pierce™ C18 Spin Tips & Columns
Thermo Scientific Pierce C18 Spin Columns (10–150 μL) and Spin Tips (10–100 μL) effectively remove interfering contaminants, while also maintaining excellent binding and recovery of peptide samples for use upstream of mass spectrometry and other high sensitivity detection methods.
| Content And Storage | Store at room temperature. |
|---|---|
| Workflow Step | Sample Clean Up |
| Final Product Type | Peptides |
| For Use With (Equipment) | Microcentrifuge, Mass Spectrometer |
| Starting Material | Peptides,Protease-digested Protein |
| Detection Method | Mass Spectrometry |
| Product Line | Pierce |
Thermo Scientific™ Pierce™ Albumin Serum Depletion Kits
Optimize serum sample prep by depleting unwanted albumin and IgG serum proteins for protein-profiling methods using quality depletion kits.
| Final Product Type | Protein |
|---|---|
| Starting Material | Plasma,Serum |
| Product Line | Pierce |
Thermo Scientific™ MALDI Matrix Sample Pack, Single-Use
Highly purified, recrystallized CHCA, DHB and SA reagents in single-use tubes for mass spectrometry by matrix-assisted laser desorption ionization (MALDI).
Thermo Scientific™ SA MALDI Matrix, Single-Use
Highly purified, recrystallized CHCA, DHB and SA reagents in single-use tubes for mass spectrometry by matrix-assisted laser desorption ionization (MALDI).