Real Time PCR Master Mixes
- (4)
- (127)
- (105)
- (7)
- (28)
- (5)
- (3)
- (194)
- (62)
- (52)
- (17)
- (1)
- (31)
- (13)
- (5)
- (16)
- (13)
- (202)
- (2)
- (36)
- (95)
- (101)
- (165)
- (1)
- (7)
Filtered Search Results
Applied Biosystems™ Absolute Q™ MAP16 Plate Kit and 1-Step RT-dPCR Master Mix
A key component of the QuantStudio Absolute Q Digital PCR System which is powered by the patented microfluidic array plate (MAP) technology that enables consistent and automated sample separation.
Thermo Scientific™ Maxima Probe qPCR Master Mixes
Optimize qPCR with probe chemistry using standard cycling protocols with these ready-to-use qPCR master mixes.
Applied Biosystems™ TaqMan™ Fast Virus 1-Step Multiplex Master Mix for qPCR (No ROX)
TaqMan Fast Virus 1-Step Multiplex Master Mix (No ROX) is designed to enable dye flexibility for multiplexing up to four different RNA/DNA targets for high-throughput RT-qPCR.
| Shipping Condition | Dry Ice |
|---|---|
| InhibitorToleranceSimple | High |
| Concentration | 4X |
| For Use With (Application) | Microbial Detection,Gene Expression,DNA Quantification,Presence/Absence |
| PCR Method | 1-step RT-qPCR |
| Multiplex Capability | Up to 4-plex |
| Detection Method | Primer-probe |
| Thermostability | Not Applicable |
| Passive Reference Dye | None |
| For Use With (Equipment) | 7500 Fast System, 7500 System, 7900HT System, QuantStudio™ 12k Flex, QuantStudio™ 3, QuantStudio™ 5, QuantStudio™ 6 Flex, QuantStudio™ 6 Pro, QuantStudio™ 7 Flex, QuantStudio™ 7 Pro, StepOne™, StepOnePlus™, ViiA™ 7 System |
| Sample Type | RNA, DNA |
| Reaction Speed | Fast or Standard |
| Target Specificity | RNA only, Both RNA and DNA |
| Hot Start | Built-In Hot Start |
Applied Biosystems™ Absolute Q™ Universal DNA Digital PCR Master Mix (5X)
Absolute Q Universal DNA Digital PCR Master Mix is compatible with a broad range of applications and over 20 million Applied Biosystems predesigned TaqMan Assays, eliminating the need to design custom assays.
Thermo Scientific™ Maxima Probe qPCR Master Mix (2X), with separate ROX vial
Optimize qPCR with probe chemistry using standard cycling protocols with these ready-to-use qPCR master mixes.
| Polymerase | Taq DNA Polymerase |
|---|---|
| GC-Rich PCR Performance | High |
| Format | Tube |
| Product Type | qPCR Master Mix |
| For Use With (Equipment) | BioRad CFX96™, BioRad iCycler iQ, BioRad iQ5, BioRad MyiQ, MJ Chromo4, Eppendorf MasterCycler RealPlex, Corbett RotorGene, Bio-Rad CFX384 Touch™, Roche LightCycler 480, Cepheid SmartCycler, MJ Opticon |
| Sample Type | DNA, dsDNA |
| Reaction Speed | Standard |
| Concentration | 2X |
| For Use With (Application) | Gene Expression |
| PCR Method | qPCR |
| Product Line | Maxima |
| Detection Method | Primer-probe |
Applied Biosystems™ TaqPath™ DuraPlex™ 1-Step RT-qPCR Master Mix
Applied Biosystems TaqPath DuraPlex 1-Step RT-qPCR Master Mix is a benchtop-stable, single-tube master mix optimized for rapid, sensitive, and reproducible detection of viral and bacterial pathogens even in the presence of PCR inhibitors.
| Shipping Condition | Dry Ice |
|---|---|
| GC-Rich PCR Performance | Medium |
| Content And Storage | Store at -15°C to -25°C. Store at room temperature (24°C) for 1 week after first use and 4°C for 1 month after first use. |
| Form | Liquid |
| InhibitorToleranceSimple | High |
| Concentration | 4X |
| For Use With (Application) | Microbial Detection,Gene Expression,DNA Quantification,Presence/Absence |
| PCR Method | 1-step RT-qPCR |
| Multiplex Capability | Up to 5-plex |
| Detection Method | Primer-probe |
| Includes | dUTP |
| Thermostability | 8 hr., Assembled Reaction |
| Polymerase | Applied Biosystems™ AmpliTaq™ DNA Polymerase with Hot Start |
| Format | Single-Tube |
| Passive Reference Dye | ROX (Pre-mixed) |
| Reaction Speed | Fast or Standard |
| Target Specificity | RNA only, Both RNA and DNA |
| Hot Start | Antibody-based |
| Shelf Life | Two years from date of manufacture, with guaranteed minimum shelf life of ≥1 year upon receipt |
| Product Line | TaqPath |
Applied Biosystems™ TaqPath™ DuraPlex™ 1-Step RT-qPCR Master Mix, no ROX™
Applied Biosystems TaqPath DuraPlex 1-Step RT-qPCR Master Mix is a benchtop-stable, single-tube master mix optimized for rapid, sensitive, and reproducible detection of viral and bacterial pathogens even in the presence of PCR inhibitors.
| Shipping Condition | Dry Ice |
|---|---|
| GC-Rich PCR Performance | Medium |
| Content And Storage | Store at –15 to –25°C. Store at room temperature (24°C) for 1 week after first use and 4°C for 1 month after first use. |
| Form | Liquid |
| InhibitorToleranceSimple | High |
| For Use With (Application) | Microbial Detection,Gene Expression,DNA Quantification,Presence/Absence |
| PCR Method | 1-step RT-qPCR |
| Multiplex Capability | Up to 6-plex |
| Detection Method | Primer-probe |
| Includes | dUTP |
| Thermostability | 8 hr., Assembled Reaction |
| Polymerase | Applied Biosystems™ AmpliTaq™ DNA Polymerase with Hot Start |
| Format | Single-Tube |
| Passive Reference Dye | None |
| Reaction Speed | Fast or Standard |
| Target Specificity | RNA only, Both RNA and DNA |
| Hot Start | Antibody-based |
| Shelf Life | Two years from date of manufacture, with guaranteed minimum shelf life of ≥1 year upon receipt |
| Product Line | TaqPath |
Applied Biosystems™ PowerTrack™ SYBR Green Master Mix for qPCR
PowerTrack SYBR Green Master Mix is a pre-formulated, optimized, universal 2X master mix for real-time PCR workflows with built-in visual dye–based indicators for accurate reaction set up.
| Shipping Condition | Dry Ice |
|---|---|
| Content And Storage | • PowerTrack SYBR Green Master Mix • 40X Yellow Sample Buffer Store at -20±5°C in the dark. |
| InhibitorToleranceSimple | High |
| Concentration | 2X |
| For Use With (Application) | Gene Expression,Microbial Detection |
| PCR Method | qPCR |
| Multiplex Capability | Single-plex |
| Detection Method | SYBR |
| Includes | dUTP, UNG/UDG |
| Thermostability | 8 hr., Assembled Reaction |
| Polymerase | Taq DNA Polymerase |
| Format | Tube |
| Product Type | Real Time PCR SYBR Master Mix |
| Passive Reference Dye | ROX (Pre-mixed) |
| For Use With (Equipment) | 7500 Fast System, 7500 System, 7900HT Fast System, 7900HT System, QuantStudio 3, QuantStudio 5, QuantStudio 6 Flex, QuantStudio 6 Pro, QuantStudio 7 Flex, QuantStudio 7 Pro, QuantStudio 12K Flex, Bio-Rad CFX Connect, Bio-Rad CFX384 Touch, Bio-Rad CFX96 Touch, BioRad CFX96, BioRad iCycler iQ, BioRad iQ5, BioRad MyiQ, ViiA 7 System, StepOne System, MJ Chromo4, MJ Opticon, StepOnePlus System, Roche LightCycler 480, Stratagene Mx3000P, Stratagene Mx3005P, Stratagene Mx4000 |
| Sample Type | DNA |
| Reaction Speed | Fast or Standard |
| Target Specificity | cDNA or gDNA only |
| Product Line | Applied Biosystems |
Applied Biosystems™ TaqMan™ Environmental Master Mix 2.0
Accurate, real-time PCR-based pathogen detection in the presence of high levels of inhibitors.
| Purity or Quality Grade | UP (Ultra Pure) |
|---|---|
| Concentration | 2X |
| For Use With (Application) | Gene Expression,Genotyping,Pathogen Detection,Virus Detection |
| PCR Method | qPCR |
| Detection Method | Primer-probe |
| Polymerase | AmpliTaq Gold DNA Polymerase |
| Format | Bottle |
| Product Type | qPCR Master Mix |
| Passive Reference Dye | ROX (Pre-mixed) |
| For Use With (Equipment) | 7000 System, 7300 System, 7500 Fast System, 7500 System, 7900HT Fast System, 7900HT System, StepOne™, Standard Mode |
| Sample Type | Environmental Sample, Food |
| Reaction Speed | Standard |
| Hot Start | Built-In Hot Start |
| Product Line | TaqMan |
Invitrogen™ Platinum™ Quantitative PCR SuperMix-UDG
Is a ready-to-use mixture for high-specificity, real-time quantitative DNA amplification, containing UDG to prevent carryover contamination (1,2).
| Shipping Condition | Dry Ice |
|---|---|
| GC-Rich PCR Performance | High |
| Product Type | Quantitative PCR SuperMix-UDG |
| For Use With (Equipment) | 7500 System, BioRad iCycler iQ, BioRad iQ5, Stratagene Mx4000, MJ Chromo4, MJ Opticon, Stratagene Mx3000P, Stratagene Mx3005P, Cepheid SmartCycler, BioRad MyiQ |
| Sample Type | DNA (Genomic), cDNA |
| Reaction Speed | Standard |
| For Use With (Application) | Gene Expression |
| PCR Method | qPCR |
| Product Line | Platinum |
| Detection Method | Primer-probe |
Invitrogen™ Platinum™ Quantitative PCR SuperMix-UDG w/ROX
qPCR SuperMixes with ROX for ABI instruments are ready-to-use reaction mixes for high-specificity, real-time amplification of cDNA, genomic DNA or plasmid DNA.
| Shipping Condition | Dry Ice |
|---|---|
| Polymerase | Platinum Taq DNA Polymerase |
| GC-Rich PCR Performance | High |
| Fidelity (vs. Taq) | 2 X |
| Product Type | Quantitative PCR SuperMix-UDG |
| For Use With (Equipment) | 7000 System, 7300 System, 7700 System, 7900HT System |
| Sample Type | DNA (Genomic), cDNA |
| Reaction Speed | Standard |
| Concentration | 2X |
| For Use With (Application) | Gene Expression |
| PCR Method | qPCR |
| Product Line | Platinum |
| Detection Method | Primer-probe |
Invitrogen™ EXPRESS qPCR Supermix, universal
EXPRESS qPCR SuperMix kits are compatible with fast-cycling instruments for probe-based qPCR assays.
| GC-Rich PCR Performance | High |
|---|---|
| Format | Tube |
| Product Type | Express qPCR Supermix |
| Sample Type | DNA (Genomic), cDNA |
| Reaction Speed | Fast or Standard |
| For Use With (Application) | Gene Expression |
| PCR Method | qPCR |
| Detection Method | Primer-probe |
Applied Biosystems™ VetMAX™ Fast Multiplex Mastermix, with ROX
VetMAX Fast Multiplex Master Mix with ROX is designed to be a fast-cycling-capable, multiplex-assay-compatible one-step RT-PCR master mix for animal molecular diagnostics.
| Polymerase | AmpliTaq™ Fast DNA Polymerase |
|---|---|
| Activation Time | 5 min. |
| Final Product Type | Mastermix |
| Form | Liquid |
| Reaction Speed | Fast |
| Label or Dye | ROX |
| Hot Start | Built-in Hot Start |
| Concentration | 2X |
| Starting Material | DNA/RNA |
| Compatibility | TaqMan™ |
| For Use With (Application) | Animal Health |
| PCR Method | 1-step RT-qPCR |
| Detection Method | Primer-probe |
Applied Biosystems™ TaqMan™ Gene Expression Master Mix
Precise and reliable real-time qPCR quantification over 9 logs of linear dynamic range with Applied Biosystems™ TaqMan™ Gene Expression Master Mix.
| Polymerase | AmpliTaq Gold DNA Polymerase |
|---|---|
| Purity or Quality Grade | UP (Ultra Pure) |
| Passive Reference Dye | ROX (Pre-mixed) |
| For Use With (Equipment) | 7000 System, 7300 System, 7500 System, 7900HT System, Applied Biosystems StepOnePlus™ Fast Real-Time PCR SystemStepOne™, Standard Mode, StepOnePlus™, Standard Mode |
| Sample Type | DNA (Genomic), cDNA |
| Reaction Speed | Standard |
| For Use With (Application) | Gene Expression |
| PCR Method | qPCR |
| Product Line | TaqMan |
| Detection Method | Primer-probe |
Applied Biosystems™ TaqMan™ Genotyping Master Mix
Optimized for end-point fluorescence detection in SNP genotyping applications.
| GC-Rich PCR Performance | High |
|---|---|
| Fidelity (vs. Taq) | 2 X |
| Purity or Quality Grade | UP (Ultra Pure) |
| Concentration | 2X |
| For Use With (Application) | Genotyping |
| PCR Method | qPCR |
| Detection Method | Primer-probe |
| Polymerase | AmpliTaq Gold DNA Polymerase |
| Genotyping Target | Copy Number Variants, SNPs (Unknown or Numerous), Drug Metabolizing Enzymes, SNPs (Known) |
| Product Type | Genotyping Master Mix |
| Passive Reference Dye | ROX (Pre-mixed) |
| For Use With (Equipment) | Applied Biosystems StepOnePlus™ Fast Real-Time PCR System, QuantStudio™ 12k Flex, QuantStudio™ 3, QuantStudio™ 5, QuantStudio™ 6 Flex, QuantStudio™ 7 |
| Sample Type | DNA (Genomic) |
| Reaction Speed | Standard |
| Technique | SNP Genotyping (Real-Time PCR-Based), CNV (Copy Number Variation) |
| Product Line | TaqMan |