GC Capillary Columns
- (1)
- (3)
- (31)
- (13)
- (18)
- (4)
- (1)
- (134)
- (1)
- (6)
- (10)
- (5)
- (39)
- (2)
- (5)
- (2)
- (1)
- (1)
- (2)
- (44)
- (15)
- (15)
- (3)
- (5)
- (2)
- (12)
- (1)
- (1)
- (1)
- (3)
- (1)
- (1)
- (78)
- (40)
- (54)
- (21)
- (9)
- (11)
- (1)
- (38)
Filtered Search Results
Thermo Scientific™ TraceGOLD TG-5MS AMINE GC Columns
Thermo Scientific™ TraceGOLD TG-5MS AMINE GC Column enables analysis of ppm levels of amines without column priming.
| Max. Temperature | 300/315°C |
|---|---|
| Stationary Phase | TraceGOLD™ TG-5 MS Amine |
| Polarity | Low-Polar |
| For Use With (Application) | GC/MS for Analysis of Amines and Other Basic Compounds, Including Alkylamines, Diamines, Triamines, and Ethanolamines,GC/MS for Nitrogen-Containing Heterocyclics |
Thermo Scientific™ TRACE™ TR-1 GC Columns
Use this non-polar GC column for method development and analysis of chlorinated and nitroaromatic compounds and environmental samples.
| Stationary Phase | TR-1 |
|---|
| Max. Temperature | 330/360°C |
|---|---|
| Polarity | Mid-Polar |
| USP Type | G42 |
Thermo Scientific™ TRACE™ TR-5MS GC Columns, 0.25μm, 0.25mm I.D., 30m length
Thermo Scientific™ TRACE TR-5MS GC Columns feature a popular GCMS phase for many applications.
Thermo Scientific™ TRACE™ TR-BioDiesel GC Columns
Determine methanol, fatty acid methyl esters (FAMEs) and glycerides in biodiesel analysis with high performance and reproducibility.
| Max. Temperature | 300/320°C |
|---|---|
| Stationary Phase | Trace™ TR-BioDiesel |
| USP Type | G1, G2, G38 |
| Product Line | TRACE |
Thermo Scientific™ TRACE™ GC Columns for Pesticides
Identify organophosphate and organochlorine pesticides with high performance, sensitivity and reproducibility.
| Max. Temperature | 280/300°C |
|---|---|
| Length (Metric) | 30 m |
| Diameter (Metric) | 0.25 mm |
| Diameter (Metric) Inner | 0.25 mm |
| For Use With (Application) | Pesticides Analysis |
| Film Thickness | 0.25 μm |
| USP Type | G43 |
| Product Line | TRACE |
Thermo Scientific™ TraceGOLD TG-5SilMS GC Columns
Incorporates phenyl groups in the polymer backbone for improved thermal stability, reduced bleed and reduced susceptibility to oxidation.
| Max. Temperature | 330/350°C |
|---|---|
| Stationary Phase | TraceGOLD™ TG-5 SilMS |
| Polarity | Low-Polar |
| For Use With (Application) | GC/MS Applications Using Ion-Trap Systems,GC/MS for Polycyclic Aromatics, Phthalates, Phenols, Amines, and Organophosphates,GC/MS for Hydrocarbons Including Chlorinated Hydrocarbons |
| USP Type | G27, G36 |
MilliporeSigma™ Supelco™ SPB™-5 Capillary GC Column, df 1.5 μm
Non-polar general purpose column provides primarily a boiling point elution order with a slight increase in selectivity, especially for aromatic compounds.
| Type | Capillary GC |
|---|---|
| Packing Material | Poly(5% diphenyl/95% dimethyl siloxane) |
| Diameter (Metric) Inner | 0.53 mm |
| Material | Fused Silica |
| For Use With (Application) | Gas Chromatography (GC) |
| Film Thickness | 1.5 μm |
| Product Line | SPB |
MilliporeSigma™ Supelco™ SLB™-1ms Capillary GC Column, df 0.25 μm
Commonly used column for many petrochemical appplications, or anywhere a low bleed non-polar column is required.
| Max. Temperature | -60°C to +340°C (isothermal) or 360°C (programmed) |
|---|---|
| Type | Capillary GC |
| Packing Material | Poly(dimethyl siloxane) |
| Polarity | Non-Polar |
| Material | Fused Silica |
| For Use With (Application) | Gas Chromatography (GC) |
| Film Thickness | 0.25 μm |
| USP Type | G1, G2, G9 |
| Product Line | SLB |
MilliporeSigma™ Supelco™ SPB™-5 Capillary GC Column, 0.25 μm, df 0.25 μm
Non-polar general purpose column provides primarily a boiling point elution order with a slight increase in selectivity, especially for aromatic compounds.
| Type | Capillary GC |
|---|---|
| Packing Material | Poly(5% diphenyl/95% dimethyl siloxane) |
| Material | Fused Silica |
| For Use With (Application) | Gas Chromatography (GC) |
| Film Thickness | 0.25 μm |
| Product Line | SPB |
MilliporeSigma™ Supelco™ SE-54 Capillary GC Column
Popular GC column for analyzing polynuclear aromatics and underivatized phenolics.
MilliporeSigma™ Supelco™ Petrocol™ DH Capillary GC Column, df 0.50 μm
Designed for the analysis of complex hydrocarbon mixtures.
MilliporeSigma™ Supelco™ Mol Sieve 5A PLOT Capillary GC Column
Porous-layer open-tubular (PLOT) columns are a powerful tool used in gas chromatography for analysis of fixed gases, light hydrocarbons and volatile solvents. They are mostly preferred over traditional columns.
| Max. Temperature | Subambient to 300°C (isothermal or programmed) |
|---|---|
| Type | Capillary GC |
| Length (Metric) | 30 m |
| Packing Material | Aluminosilicate |
| Material | Fused Silica |
| For Use With (Application) | Gas Chromatography (GC) |
| USP Type | None |
MilliporeSigma™ Supelco™ Carboxen™-1010 PLOT Capillary GC Column, df 15 μm
Porous-layer open-tubular (PLOT) columns are a powerful tool used in gas chromatography for analysis of fixed gases, light hydrocarbons and volatile solvents. They are mostly preferred over traditional columns.
MilliporeSigma™ Supelco™ γ-DEX™ 325 Capillary GC Column, df 0.25 μm
Capillary GC column is also known as open tubular column. The carrier gas flows through the central aperture and is unrestricted throughout the length of the column.