missing translation for 'onlineSavingsMsg'
Learn More

Thermo Scientific™ TraceGOLD TG-1301MS GC Columns

Catalog No. 260914080
Change view
Click to view available options
Length (Metric):
30 m
60 m
Diameter (Metric) Inner:
0.25 mm
0.32 mm
0.53 mm
Film Thickness:
0.25 μm
1 μm
1.4 μm
1.5 μm
1.8 μm
3 μm
13 product options available for selection
Product selection table with 13 available options. Use arrow keys to navigate and Enter or Space to select.
Catalog No. Length (Metric) Diameter (Metric) Inner Film Thickness
260914080 60 m 0.53 mm 3 μm
260911420 30 m 0.25 mm 0.25 μm
260911430 30 m 0.32 mm 0.25 μm
260911540 60 m 0.25 mm 0.25 μm
260912960 30 m 0.25 mm 1 μm
260912970 30 m 0.32 mm 1 μm
260912980 30 m 0.53 mm 1 μm
260913080 60 m 0.25 mm 1 μm
260913330 60 m 0.25 mm 1.4 μm
260913350 30 m 0.32 mm 1.5 μm
260913390 30 m 0.32 mm 1.8 μm
260913410 60 m 0.32 mm 1.8 μm
260913960 30 m 0.53 mm 3 μm
Use arrow keys to navigate between rows. Press Enter or Space to select a product option. 13 options available.
13 options
Catalog No. 260914080 Supplier Thermo Scientific™ Supplier No. 260914080
Only null left

Provides low-bleed, excellent reproducibility and column-to-column consistency even with sensitive detectors like ECDs and MS.

Thermo Scientific™ TraceGOLD TG-1301MS GC Columns provide low-bleed, excellent reproducibility and column-to-column consistency even with sensitive detectors like ECDs and MS.

  • Low to mid-polarity phase, 6% cyanopropylphenyl/94% dimethyl polysiloxane
  • Long lifetime
  • Excellent inertness
  • Equivalent to USP G43 phase
  • Similar to: Rtx-1301, DB-1301, BP-624, HP-1301, HP-624, SPB-1301, SPB-624, VP-1301, BF-624ms, CP-1301, CP-Select 624 CB

Recommended for:

  • Alcohols
  • Volatile organics
  • Oxygenates
  • Residual solvents

Specifications

Diameter (Metric) Inner 0.53 mm
Stationary Phase TraceGOLD™ TG-1301 MS
Product Line TraceGOLD
Max. Temperature 260/280°C
USP Type G43
Diameter (Metric) 0.53 mm
For Use With (Application) Residual Solvents Analysis, ECD and GC/MS for Volatile Organics, ECD and GC/MS for Oxygenates, ECD and GC/MS for Residual Solvents
Film Thickness 3 μm
Length (Metric) 60 m
Polarity Mid-Polar
Description 3 um Thickness; 0.53 mm ID; 60 m Length
Show More Show Less

Limited warranty period: Subject to all warranty requirements and exclusions set out in our Terms and Conditions of Sale, this product is warranted from the date we ship the product and for ninety (90) days thereafter. Disclaimer to internal research use restriction: Any restrictions on the purchaser to utilize the product(s) for internal research purposes only does not apply to the product(s) on the web pages associated with this statement.