Gas Generators and Accessories
- (2)
- (2)
- (2)
- (2)
- (1)
- (2)
- (1)
- (1)
Résultats de la recherche filtrée
Fisherbrand™ High Purity Hydrogen Gas Generators For GC Fuel Gas Accessory, PM Kit
For use with High Purity Hydrogen Gas Generators for GC Fuel Gas.
| À utiliser avec (équipement) | High Purity Hydrogen Gas Generators For GC Fuels |
|---|---|
| À utiliser avec (application) | Gas chromatography, fuel gas, flame ionization detector (GC-FID) flame photometric detector (GC-FPD), Electrolytic Conductivity Detector (ELCD & Hall ELCD), other combustion detectors |
Fisherbrand™ Ultra High Purity Hydrogen Gas Generators Accessory, Preventative Maintenance Kit
For use with Ultra High Purity Hydrogen Gas Generators for GC Carrier and Fuel Gas.
| À utiliser avec (équipement) | Ultra High Purity Hydrogen Gas Generators For GC Carrier and Fuel Gas |
|---|---|
| À utiliser avec (application) | Gas chromatography, fuel gas, carrier gas, flame ionization detector (GC-FID) flame photometric detector (GC-FPD), nitrogen phosphorous detector carrier gas (NPD), thermal conductivity detector carrier gas (TCD), Electrolytic Conductivity Detector reactio |
Fisherbrand™ Ultra High Purity Hydrogen Gas Generators for GC Carrier and Fuel Gas
Ultra High Purity Range of hydrogen gas generators offer convenient and safe alternatives to cylinder gas for gas chromatography and fuel can carrier gas applications.
| Hauteur (impériale) | 18 in. |
|---|---|
| Certifications/Conformité | CE, cULus |
| À utiliser avec (équipement) | Gas Chromatograph |
| Pression de sortie | 10 to 100 psig |
| Garantie | 12 months on system, 24 months on PEM cell |
| Port de sortie | compression fitting |
| Raccordements | 1/8 in. Compression |
| Pression | 10 to 100 psig |
| À utiliser avec (application) | Gas chromatography, fuel gas, carrier gas, flame ionization detector (GC-FID) flame photometric detector (GC-FPD), nitrogen phosphorous detector carrier gas (NPD), thermal conductivity detector carrier gas (TCD), Electrolytic Conductivity Detector reactio |
| Fréquence | 50/60 Hz |
| Type | Hydrogen Carrier Gas Generator |
| Alimentation électrique | Universal (90V - 264V 50/60Hz) |
| Largeur (métrique) | 34.2 cm |
| Hauteur (métrique) | 45.6 cm |
| Profondeur (impériale) | 18.5 in. |
| Température ambiante max. de fonctionnement | 5°C to 40°C (41°F to104°F) |
| Comprend | US, UK and EU power cord, Water drain tube, DI cartridge, User guide |
| Tension | 90-264 Universal Power Supply |
| Largeur (impériale) | 13.5 in. |
| Profondeur (métrique) | 47 cm |
Fisherbrand™ Zero Air Generators
Zero air gas generators provide a convenient and safe alternative to cylinder gas for gas chromatography combustion applications. These systems remove organic impurities from existing compressed air sources allowing the user to eliminate expensive bottled zero grade air from their lab.
| Hauteur (impériale) | 12 in. |
|---|---|
| Débit | 1 L/min. |
| Certifications/Conformité | CE, CSA, cULus |
| À utiliser avec (équipement) | Gas Chromatograph |
| Pureté | Gas purity: <0.1ppm total hydrocarbon as CH4 |
| Pression de sortie | Up to 135 psig depending on inlet pressure |
| Capacité | 1 L/min |
| Garantie | 12 months on system |
| Température max. de l’air d’admission | 104°F |
| Port de sortie | 1/4 in. NPT (female) |
| Raccordements | 1.4 in. NPT (female) |
| Pression | Varies with inlet. 5 psig less than inlet |
| À utiliser avec (application) | Gas chromatography, Flame ionization detector (GC-FID) flame photometric detector (GC-FPD), Electrolytic Conductivity Detector (ELCD & Hall ELCD), other combustion detectors |
| Fréquence | 60 Hz |
| Type | Zero Air Gas Generator |
| Largeur (métrique) | 25 cm |
| Hauteur (métrique) | 30 cm |
| Profondeur (impériale) | 3 in. |
| Température ambiante max. de fonctionnement | 5°C to 40°C (41°F to104°F) |
| Comprend | US power cord, User guide |
| Dimension de la sortie | 1/4 in. |
| Nbre de FID | 2-3 |
| Profondeur (métrique) | 8 cm |
| Poids (métrique) | 3 kg |
Fisherbrand™ Zero Air Generators Accessory, 24 month Catalyst Kits
For use with Zero Air Generators.
| Type | 24 Month Catalyst Kit |
|---|---|
| À utiliser avec (application) | Gas chromatography, flame support gas, flame ionization detector (GC-FID) flame photometric detector (GC-FPD) |
Fisherbrand™ High Purity Hydrogen Gas Generators For GC Fuel Gas Accessory, Desiccant Cartridge
For use with High Purity Hydrogen Gas Generators for GC Fuel Gas.
Fisherbrand™ Zero Air Generators For GC Fuel Accessory, 24 Month Fan Kits
For use with Zero Air Generators for GC Fuel.
| Type | 24 Month Fan Kit |
|---|---|
| À utiliser avec (équipement) | Zero Air Generators For GC Fuel (14950656, 14950658, 14950660, 14950662) |
| À utiliser avec (application) | Gas chromatography, flame support gas, flame ionization detector (GC-FID) flame photometric detector (GC-FPD) |
Fisherbrand™ Zero Air Generators For GC Fuels
Zero air generators produce a continuous stream of organic impurity-free air from external dry compressed air source and offer superior limits of detection over and above other modes of supply.
| Hauteur (impériale) | 18 in. |
|---|---|
| Certifications/Conformité | CE, cULus |
| À utiliser avec (équipement) | Gas Chromatograph |
| Pureté | Gas purity: <0.1ppm total hydrocarbon as CH4 |
| Pression de sortie | Up to 135 psig depending on inlet pressure |
| Garantie | 12 months on system |
| Température max. de l’air d’admission | 104°F |
| Port de sortie | Compression fitting |
| Pression | Varies with inlet. 5 psig less than inlet |
| À utiliser avec (application) | Gas chromatography, Flame support gas, Flame ionization detector (GC-FID) Flame photometric detector (GC-FPD) |
| Type | Zero Air Gas Generator |
| Largeur (métrique) | 34.2 cm |
| Hauteur (métrique) | 45.5 cm |
| Profondeur (impériale) | 16.7 in. |
| Température ambiante max. de fonctionnement | 5°C to 40°C (41°F to104°F) |
| Largeur (impériale) | 13.5 in. |
| Profondeur (métrique) | 42.5 cm |
| Poids (métrique) | 14.2 kg |
Fisherbrand™ High Purity Hydrogen Gas Generators For GC Fuel Gas
High purity range of hydrogen gas generators offer convenient and safe alternatives to cylinder gas for gas chromatography.
| Hauteur (impériale) | 18 in. |
|---|---|
| Certifications/Conformité | CE, CSA, cULus |
| À utiliser avec (équipement) | Gas Chromatograph |
| Pression de sortie | 10 to 100 psig |
| Garantie | 12 months on system, 24 months on PEM cell |
| Port de sortie | compression fitting |
| Raccordements | 1/8 in. Compression |
| Pression | 10 to 100 psig |
| À utiliser avec (application) | Gas chromatography, fuel gas, flame ionization detector (GC-FID) flame photometric detector (GC-FPD), Electrolytic Conductivity Detector (ELCD & Hall ELCD), other combustion detectors |
| Fréquence | 50/60 Hz |
| Type | Hydrogen Fuel Gas Generator |
| Alimentation électrique | Universal (90V - 264V 50/60Hz) |
| Largeur (métrique) | 34.2 cm |
| Hauteur (métrique) | 45.6 cm |
| Profondeur (impériale) | 17 in. |
| Température ambiante max. de fonctionnement | 5°C to 40°C (41°F to104°F) |
| Comprend | US, UK and EU power cord, Water drain tube, DI cartridge, User Guide |
| Tension | 90-264 Universal Power Supply |
| Dimension de la sortie | 1/8 in. |
| Largeur (impériale) | 13.5 in. |
| Profondeur (métrique) | 43.7 cm |
| Poids (métrique) | 23 kg (Full of water) |
MilliporeSigma™ Supelco™ domnick hunter™ Zero Air Generator
Produces a continuous supply of air that is virtually free of hydrocarbons, including methane
| Certifications/Conformité | CE Approved |
|---|---|
| Type | Air Generator |
| Comprend | 0.01 μm Filter |
| À utiliser avec (application) | Producing a Continuous Supply of Air |
MilliporeSigma™ Supelco™ domnick hunter™ NITROX™ UHP Hydrogen Generator
A safe and economic alternative to high pressure gas cylinders
| Type | Hydrogen Gas Generator |
|---|---|
| À utiliser avec (équipement) | Any Laboratory Instrument Requiring a Supply of Ultra High Purity Hydrogen |
| Pureté | 99.999% Pure Hydrogen |
| À utiliser avec (application) | Carrier Gas and Fuel Gas Applications |
| Hauteur (impériale) | 17.9 in. |
|---|---|
| Certifications/Conformité | CE, CSA, UL |
| Garantie | 2 Years |
| Port de sortie | 0.125 in. compression fitting |
| Pression | 0 to 100 psi |
| Fréquence | 50/60 Hz |
| Pureté de l’azote | 99.9995% |
| Type | Hydrogen Fuel Gas Generator |
| Alimentation électrique | 90 to 264V 50/60Hz |
| Hauteur (métrique) | 45.6 cm |
| Profondeur (impériale) | 17.2 in. |
| Température ambiante max. de fonctionnement | 5°C to 40°C |
| Tension | 90/264 V |
| Largeur (impériale) | 13.5 in. |
| Profondeur (métrique) | 34.2 cm |
| Poids (métrique) | 23 kg |
Parker domnick hunter™ Oil-XPlus™ Filter Elements for Gas Generators
Replacement elements for >Oil-XPlus Compressed Air Filters used with Zero Air Generators
| Certifications/Conformité | ISO 8573-1 |
|---|---|
| À utiliser avec (équipement) | Uhp-10za and uhp-35za |
Parker domnick hunter™ Ultra-High Purity Hydrogen Generators for GC and GC/MS
Ultra-high purity, low maintenance generators supply hydrogen for GC and GC/MS carrier gas applications, plus all commonly used combustion detectors used routinely in GC
| Hauteur (impériale) | 17.9 in. |
|---|---|
| Certifications/Conformité | CE, CSA, UL |
| Pureté | 99.9999% |
| Port de sortie | 0.125 in. compression fitting |
| Pression | 10 to 100 psi |
| Fréquence | 50/60 Hz |
| Type | Hydrogen Carrier Gas Generator |
| Alimentation électrique | 90 to 264V 50/60Hz |
| Hauteur (métrique) | 45.6 cm |
| Profondeur (impériale) | 18.5 in. |
| Température ambiante max. de fonctionnement | 5°C to 40°C |
| Tension | 90/264 V |
| Largeur (impériale) | 13.5 in. |
| Profondeur (métrique) | 47 cm |
| Poids (métrique) | 25 kg |