Filtered Search Results
MilliporeSigma™ Supelco™ Sample Loop for Model 7725 Injector, Stainless Steel
Sample loop for model 7725 injector (volume 100 μL) is best suited for advanced fluid-handling solutions for broad range of analytical instrumentation and in vitro diagnostic systems. It is useful in high performance liquid chromatographic (HPLC) systems and is quite accurate and precise in injecting 1 μL-5 mL concentration of samples.
| For Use With (Equipment) | Model 7725 |
|---|---|
| Material | Stainless Steel |
MilliporeSigma™ Supelco™ Packing Reservoirs for Non-Jacketed LC columns
Supplied complete with all fittings necessary for connection to threaded columns. The top has 1/4 -28 fitting.
| For Use With (Application) | Liquid Chromatography |
|---|
MilliporeSigma™ Supelco™ OPTI-SOLV™ Mini, Micro, and Nano Filter
The OPTI-SOLV™ Mini Filter provides low-impact filtering in a package no longer that a finger tight fitting. Use them to prolong the life of your analytical column, or before your mass spectrometer as a last line of defense against debris.
| Type | Filter |
|---|---|
| Quantity | 5/Pk. |
| For Use With (Application) | Liquid Chromatography |
| For Use With (Equipment) | 9010, 9125, and 9725 Injectors |
|---|---|
| Material | PEEK |
| For Use With (Application) | HPLC |
|---|
MilliporeSigma™ Supelco™ Mobile Phase Solvent Debubbler with Bracket
Gas bubbles in the mobile phase reduce pump output and cause check valves to malfunction. The mobile phase debubbler removes bubbles from the pump inlet line. Bubbles in the incoming mobile phase rise in the debubbler, displacing an equal volume of liquid from the debubbler reservoir to the pump. When necessary, simply remove the cap and refill the reservoir -- the gas-liquid interface is visible through the housing.
| For Use With (Application) | Liquid Chromatography |
|---|
MilliporeSigma™ Supelco™ columnSaver Precolumn Filter
The new Supelco columnSaver offers all of the protection of conventional precolumn filters at much less the cost. With its convenient direct connect design, changeover time is measured in seconds, and requires no wrenches or tools to install.
| Description | 10/Pk. |
|---|
| For Use With (Application) | Liquid Chromatography |
|---|
MilliporeSigma™ Supelco™ SSI™ High Pressure Precolumn Filter
In-line installation. The 316 stainless steel filter disc (0.5 μm pores) is easily replaced without removing the column end fitting. For 1/16 in. tubing. Maximum operating pressure: 15,000 psi (1,054 kg/cm2).
Thermo Scientific™ Bottom-of-the-Bottle™ Solvent Filters
Protect your HPLC system with Thermo Scientific™ Bottom-of-the-Bottle™ Solvent Filters.
| Type | Filter Kit |
|---|
MilliporeSigma™ Supelco™ Miniature Regulator with Gauge
Reliable pressure regulation to 1 psig (0.07 kg/cm2), indicated on a 0-60 psi (4.2 kg/cm2) gauge. Easily connects to SCOTTY 14 cylinders with the 1/8-inch NPT connector provided. You can also attach the syringe adapter (Cat. No. 609010) to the regulator for low pressure sample removal. Aluminum body with acetyl resin bonnet. Maximum inlet pressure: 400 psi (28.1 kg/cm2).
MilliporeSigma™ Supelco™ Precolumn Filter Direct-Connect, PEEK
Direct-connect; protects analytical and guard columns.
MilliporeSigma™ Supelco™ PEEK Inline Microfilter
Install between 2 pieces of capillary tubing, using Microtight tubing sleeves. PEEK housing with special PEEK fitting that encases the 0.5 μm PEEK frit. Through hole 0.006 in., swept volume 0.24 μL. Includes 2 MicroFingertight nuts, and 5 frits (1 installed).
MilliporeSigma™ Supelco™ Rheodyne™ Model 9725i PEEK Injector
Manual with MBB and switch, Number of ports: 6, Number of positions: 2