Ricca VeriSpec™ KCl Conductivity Standard, Certified Reference Material
ISO 17025/17034 KCl Conductivity Standard Certified Reference Materials provide the highest level of quality assurance. A certificate of analysis providing the specified property value, uncertainty, and traceability is available with every bottle.
| Boiling Point | 100°C |
|---|---|
| Color | Colorless |
| pH | Approximately 7 |
| Quantity | 500 mL |
| Grade | Certified |
| Solution Type | Conductivity Standard |
Traceable™ Conductivity Calibration Standards Certified Reference Material (CRM), NIST tested, Fisherbrand™
Use NIST-traceable reference materials for the highest accuracy available. Traceable™ Conductivity Calibration Standards Certified Reference Material (CRM) offer easy calibration with included instructions and temperature chart.
| Type | Conductivity Standard |
|---|---|
| For Use With (Equipment) | Conductivity Meter |
| Solubility | Soluble in water |
| Color | Clear |
| Packaging | Bottle |
| Chemical Name or Material | Conductivity Standard |
| Certifications/Compliance | ISO 17034 |
| Technique | Calibration of Conductivity Instrument |
| Solution Type | Calibration Solution |
Conductivity Standards for METTLER TOLEDO Conductivity Probes, METTLER TOLEDO™
Recommended NIST traceable solutions for calibrating or verifying METTLER TOLEDO conductivity electrodes.
| Type | Conductivity Standard |
|---|---|
| For Use With (Equipment) | Conductivity Electrodes |
| Recommended Storage | Ambient |
| Solution Type | Conductivity Standard |
Thermo Scientific™ Orion™ Conductivity Calibration Standards
High-accuracy conductivity calibration standards traceable to NIST™ standard reference materials, designed for reliable and reproducible measurements in lab and field. Available in a wide range of conductivity values to support consistent calibration, reliable measurements and regulatory.
| Boiling Point | 100°C |
|---|---|
| Type | Conductivity Calibration Standard |
| Description | Conductivity Standard |
| Solubility | Soluble |
| Color | Clear |
| Traceability to NIST | Yes |
| Solution Type | Standard Solution |
Traceable™ One-Shot™ Conductivity Calibration Standards Certified Reference Material Producer (CRM), Fisherbrand™
Ideal for lab or field applications
| For Use With (Equipment) | Conductivity Meter |
|---|---|
| Solubility | Soluble in water |
| Color | Clear |
| Packaging | 6/Pk. |
| Chemical Name or Material | Conductivity Standard |
| Boiling Point | 100°C |
|---|---|
| Type | Conductivity Standard |
| Name Note | 10mS/cm ((10, 000μmho/cm) at 25°C, 5400ppm as NaCl |
| Concentration or Composition (by Analyte or Components) | 5400ppm as NaCl |
| CAS | 7732-18-5 |
| Color | Colorless |
| Physical Form | Liquid |
| CAS Min % | 0.53 |
| Chemical Name or Material | Conductivity/TDS Standard |
| Solution Type | Conductivity Standard |
| CAS Max % | 0.55 |
| Boiling Point | 100°C |
|---|---|
| Type | Conductivity Standard |
| Color | Colorless |
| pH | 6.7 to 7.3 |
| Physical Form | Liquid |
| Chemical Name or Material | Conductivity Standard |
| Odor | Odorless |
| Solution Type | Conductivity Standard |
Traceable™ Conductivity Calibration Standards Certified Reference Material (CRM), Fisherbrand™
Use NIST-traceable reference materials for the highest accuracy available. TraceableTM Conductivity Calibration Standards Certified Reference Material (CRM) offer easy calibration with included instructions and temperature chart.
Conductivity Solution, Oakton™
Use this conductivity solution for accurate test results in the field or lab. Oakton™ Conductivity Solutions have KCl, NaCl and 442 conversions printed on the bottle for ease of use.
| Boiling Point | 100°C (212°F) |
|---|---|
| Type | Conductivity Standard |
| For Use With (Equipment) | Conductivity Meter |
| Solubility | Soluble |
| Color | Clear |
| pH | 4.7 to 7.8 |
| Packaging | Bottle |
| Quantity | 500 mL |
| Chemical Name or Material | Cole-Parmer Conductivity Standards |
| Technique | Calibration of Conductivity Instrument |
| Solution Type | Conductivity Standard |
Potassium Chloride Conductivity Standard, 20,000 μS/cm (20 mS/cm) at 25°C, Ricca Chemical
CAS: 7447-40-7 Molecular Formula: ClK Molecular Weight (g/mol): 74.55 MDL Number: MFCD00011360 InChI Key: WCUXLLCKKVVCTQ-UHFFFAOYSA-M PubChem CID: 4873 ChEBI: CHEBI:32588 IUPAC Name: potassium chloride SMILES: [Cl-].[K+]
| PubChem CID | 4873 |
|---|---|
| CAS | 7447-40-7 |
| Molecular Weight (g/mol) | 74.55 |
| ChEBI | CHEBI:32588 |
| MDL Number | MFCD00011360 |
| SMILES | [Cl-].[K+] |
| IUPAC Name | potassium chloride |
| InChI Key | WCUXLLCKKVVCTQ-UHFFFAOYSA-M |
| Molecular Formula | ClK |
Potassium Chloride Conductivity Standard, 50,000 μS/cm (50 mS/cm) at 25°C, Ricca Chemical
CAS: 7447-40-7 Molecular Formula: ClK Molecular Weight (g/mol): 74.55 MDL Number: MFCD00011360 InChI Key: WCUXLLCKKVVCTQ-UHFFFAOYSA-M PubChem CID: 4873 ChEBI: CHEBI:32588 IUPAC Name: potassium chloride SMILES: [Cl-].[K+]
| PubChem CID | 4873 |
|---|---|
| CAS | 7447-40-7 |
| Molecular Weight (g/mol) | 74.55 |
| ChEBI | CHEBI:32588 |
| MDL Number | MFCD00011360 |
| SMILES | [Cl-].[K+] |
| IUPAC Name | potassium chloride |
| InChI Key | WCUXLLCKKVVCTQ-UHFFFAOYSA-M |
| Molecular Formula | ClK |
Potassium Chloride Conductivity Standard, 10 μS/cm at 25°C, Ricca Chemical
CAS: 7447-40-7 Molecular Formula: ClK Molecular Weight (g/mol): 74.55 MDL Number: MFCD00011360 InChI Key: WCUXLLCKKVVCTQ-UHFFFAOYSA-M PubChem CID: 4873 ChEBI: CHEBI:32588 IUPAC Name: potassium chloride SMILES: [Cl-].[K+]
| PubChem CID | 4873 |
|---|---|
| CAS | 7447-40-7 |
| Molecular Weight (g/mol) | 74.55 |
| ChEBI | CHEBI:32588 |
| MDL Number | MFCD00011360 |
| SMILES | [Cl-].[K+] |
| IUPAC Name | potassium chloride |
| InChI Key | WCUXLLCKKVVCTQ-UHFFFAOYSA-M |
| Molecular Formula | ClK |
Conductivity Standard, METTLER TOLEDO
The 250 mL standard conductivity solution, with a precise conductivity, is ideal for calibrating conductivity meters used in laboratory and field applications.
| CAS | 7647-01-0 |
|---|
Potassium Chloride Conductivity Standard, 500 μS/cm at 25°C, Ricca Chemical
CAS: 7447-40-7 Molecular Formula: ClK Molecular Weight (g/mol): 74.55 MDL Number: MFCD00011360 InChI Key: WCUXLLCKKVVCTQ-UHFFFAOYSA-M PubChem CID: 4873 ChEBI: CHEBI:32588 IUPAC Name: potassium chloride SMILES: [Cl-].[K+]
| PubChem CID | 4873 |
|---|---|
| CAS | 7447-40-7 |
| Molecular Weight (g/mol) | 74.55 |
| ChEBI | CHEBI:32588 |
| MDL Number | MFCD00011360 |
| SMILES | [Cl-].[K+] |
| IUPAC Name | potassium chloride |
| InChI Key | WCUXLLCKKVVCTQ-UHFFFAOYSA-M |
| Molecular Formula | ClK |