Fisherbrand™ Traceable™ pH/ORP/Temperature Meter
Measure critical water quality parameters — without the need to carry multiple units.
Fisherbrand™ accumet™ XL600 Benchtop Dual pH/ISE, Conductivity and Dissolved Oxygen Meters
Provide advanced measurements with simple operation and offer a large, vivid color touch-screen display. Fisherbrand accumet XL600 pH/ISE/conductivity/DO benchtop meters offer advanced features with simple operation to help ensure your measurements are reliable and your laboratory processes are efficient.
| Certifications/Conformité | NIST, ISO, FDA, USDA, EPA |
|---|---|
| Précision (résistivité) | ± 1% full scale |
| Dimensions (L x l x H) | 24.6 x 17.3 x 9.9cm (9.7 x 6.8 x 3.9 in.) |
| Longueur (impériale) | 9.68 in. |
| Détails de la gestion des données | 3 to 86400 sec. |
| Tension | 100/240 V |
| Précision de la température | ±0.2°C (±0.3°F) |
| Points d’étalonnage (pH) | Up to 6 preset or 5 custom |
| Poids (métrique) | 1.13 kg |
| Gamme (OD) | 0 to 20mg/L (0 to 1272mbar), 0 to 200% saturation with 13-620-SSP electrode |
| Résultats | RS232, USB-A, Mini-B USB, RJ45, stirrer port (2) |
| Résolution (pH) | 0.1/0.01/0.001 |
| Entrées | 2 BNC, 2 ATC |
| Résolution (conductivité) | 0.001/0.01/0.1mS |
| Précision (DO) | 0.1 +1 LSD |
| Poids (impériale) | 2.5 lb. |
| Résolution (mV) | 0.1mV |
| Précision (TDS) | ± 1% full scale |
| Précision (salinité) | ± 1% full scale |
| Type d’écran | LCD |
| Hauteur (impériale) | 3.89 in. |
| Précision | Multiple |
| Résolution de la température | 0.1°C |
| Résolution (ionométrie) | 2/3/4 Digits |
| Précision (pH) | ±0.002 |
| Garantie | 3 Years |
| Précision (ionométrie) | 0.5% full scale (monovalent ion), 1% full scale (divalent ion) |
| Résolution (TDS) | 0.01/0.1ppm, 0.001/0.01/0.1ppt |
| Points d’étalonnage (conductivité) | Automatic (4 points), maximum 1/range, manual (5 points), maximum 1/range |
| Résolution (OD) | 0.01mg/L (0.1mbar), 0.1% saturation |
| Gamme (salinité) | 0 to 80 ppt |
| Fréquence | 50/60Hz |
| Gamme (résistivité) | 3 W to 100 MW over 4 ranges: 0 to 20 kW, 20 to 200 kW, 200 kW to 2 MW, 2 to 100 MW |
| Gamme (ionométrie) | ±2000 mV |
| Points de données | 2000 |
| Points d’étalonnage (ionométrie) | 2 to 6 |
| Précision (conductivité) | ±1% FS |
| Longueur (métrique) | 24.6 cm |
| Constante de cellule | 0.01 to 10 |
| Résolution (salinité) | 0.01/0.1ppm, 0.001/0.01/0.1ppt |
| Résolution (résistivité) | 0.01/0.1W, 0.001/0.1kW, 0.01MW |
| Gamme (TDS) | 0.050 ppm to 500 ppt (at TDS factor 1.00) |
| Résolution | Multiple |
| Gamme (mV) | ±2000 mV |
| Hauteur (métrique) | 9.9 cm |
| Largeur (métrique) | 17.3 cm |
| Précision (mV) | ±0.2 mV |
| Gamme (pH) | -2 to 20 |
| Gamme (conductivité) | 0 to 500 mS |
| Échelle de lecture | Multiple |
Fisherbrand™ accumet™ AP125 Portable pH/Ion/mV/Temperature Meter
Accurate measurements any time, anywhere
| Précision | Multiple |
|---|---|
| Type de produit | Meter Only |
| Garantie | 3 Years |
| Résolution (pH) | Adjustable |
| Points d’étalonnage | 10 |
| Modes de mesure | pH,Ion,mV,Temperature |
| Résolution | Multiple |
| Gamme (mV) | 0 to ±2000 mV |
| À utiliser avec (application) | pH, Ion concentration, mV, Temperature |
| Précision (mV) | 0 to ±2000mV |
| Plage de températures (métrique) | -5°C to +100°C |
| Indice IP | IP67 |
| Plage | -2 to +20pH |
| Comprend | Meter, 9V battery, manual |
| Gamme (pH) | 2 to 20 |
| Plage de températures (impériale) | 23°F to 212°F |
| Type d’écran | LCD |
| Points de données | 200 |
OHAUS™ Aquasearcher™ Multi-Parameter Analyzer AB33M1
The Aquasearcher™ Multi-Parameter Analyzer AB33M1 is easy-to-use and accurate, capable of measuring up to seven parameters including pH, ORP, conductivity, TDS, salinity, resistivity, and temperature.
| Résolution (ionométrie) | 0.01 pH |
|---|---|
| Résultats | RS232, USB Device (Included) |
| Résolution (pH) | 0.1/0.01 pH |
| Gamme (TDS) | 0.1 mg/L to 199.9 g/L |
| Modes de mesure | Auto-stop,Continuous |
| Canaux | pH, Conductivity |
| Gamme (mV) | -2000 to 2000 mV |
| Gamme (salinité) | 0 to 100 psu |
| Plage de températures (métrique) | -5°C to +110°C |
| Indice IP | None |
| Gamme (pH) | -2 to 20 |
| Gamme (résistivité) | 2 to 100 MΩ-cm |
| Gamme (conductivité) | 0.01 μS/cm to 500 mS/cm |
| Type d’écran | LCD |
Thermo Scientific™ Elite ORP Pocket Testers and Replacement Sensors
Flexible on-the-go ORP testing using durable Elite ORP pocket testers with replaceable sensors for a variety of applications including hydroponics, food and beverage, environmental and more!
Thermo Scientific™ Elite pH Spear Pocket Testers and Replacement Sensors
Flexible on-the-go pH testing using durable Elite spear pocket testers with replaceable sensors for a variety of applications include food, beverage, agriculture and more!
| Résolution de la température | 0.1°C, 0.1°F |
|---|---|
| Température (métrique) en fonctionnement | 5°C to 45°C (ambient) |
| Précision (pH) | ±0.02 |
| Plage de températures (métrique) | 0.0°C to 60.0°C |
| Résolution (pH) | 0.01 |
| Gamme (pH) | -1 to 15 |
| Précision de la température | Manual input |
| Modes de mesure | pH |
| Plage de températures (impériale) | 32.0°F to 140.0°F |
Fisherbrand™ accumet™ AR450 pH/ion/Conductivity Meter with Stand
Designed to deliver precise and reliable electrochemistry testing, the accumet AR450 offers enhanced performance in a streamlined design. Ideal for laboratories requiring dependable measurement capabilities.
Thermo Scientific™ Orion™ Pro Star MP218 pH/ion, Conductivity and DO Bench Meter
Designed to provide accurate and reliable pH, ORP, ion, conductivity, TDS, salinity, resistivity, DO, barometric pressure and temperature analysis, the Thermo Scientific™ Orion™ Pro Star MP218 bench meter is well suited for laboratories that desire a modern meter with advance performance.
| Certifications/Conformité | CE, TUV 3-1, FCC Class A |
|---|---|
| Clavier | Capacitive touchscreen user interface |
| Précision (résistivité) | ±0.5% reading |
| Dimensions (L x l x H) | 218.9 x 153.2 x 91.33 mm; 8.62 x 6.03 x 3.60 in. |
| Gamme de coefficients de saturation (OD par mesure polarographique) | 0.0 to 600.0% saturation |
| Langues | Chinese, English, French, German, Italian, Japanese, Korean, Portuguese, Spanish |
| Option de rétro-éclairage | Yes |
| Fonctions d’ionométrie avancées | Single known addition, single known subtraction, double known addition, double known subtraction, analyte addition and analyte subtraction |
| Précision de la température | ±0.3°C, ±0.5°F |
| Gamme de pressions | 400.0 to 850.0 mmHg; 0.533 to 1.133 bar |
| Points d’étalonnage (pH) | 1 to 5 points |
| Poids (métrique) | 1.00 kg |
| Gamme (OD) | 0.0 to 600.0% saturation; 0.01 to 90.0 mg/L or ppm |
| Sorties d’alarme | Calibration reminder alarm, high and low limit alarm per parameter |
| Résultats | USB flash drive, computer or printer (STARA-106) |
| Type de fonction d’enregistrement | Automatic with Auto-Read and Timed Read Modes, Manual with Continuous Read Mode |
| Résolution (pH) | 0.1, 0.01 or 0.001 pH |
| Résolution (rH) | 0.1 mV |
| Précision relative du coefficient de saturation (OD par mesure polarographique) | ±2% saturation |
| Entrées | Channel 1: BNC for pH, ORP or ISE, 8-pin MiniDIN for ATC, pin-tip for reference; Channel 2: 8-pin MiniDIN for conductivity with ATC; Channel 3: 9-pin MiniDIN for dissolved oxygen with ATC |
| Étalonnage | pH, ORP, Ion Concentration, Conductivity, TDS, Salinity, DO, Barometric Pressure, Temperature |
| Température (métrique) de référence | 5, 10, 15, 20, 25 or 30°C |
| Résolution (conductivité) | 0.001 μS/cm minimum, auto-ranging, up to 4 digits |
| Gamme (RDO) | 0.0 to 600.0% saturation; 0.01 to 90.0 mg/L or ppm |
| Résolution du coefficient de saturation (OD par mesure polarographique) | 0.1, 1% saturation |
| Gamme (mV relative) | -2000 to 2000 mV |
| Mémoire | Non-volatile |
| Précision (DO) | ±2% saturation; ±0.02 mg/L or ppm |
| Poids (impériale) | 2.20 lbs. |
| Précision (baromètre) | ±6.0 mmHg; ±0.008 bar |
| Résolution (mV) | 0.1 mV |
| Plage de températures (métrique) | -30.0°C to +130.0°C |
| Facteur de salinité | 0.0 to 50.0 ppt; automatic with conductivity measurement or manual entry |
| Précision (TDS) | ±0.5% reading |
| Précision (salinité) | ±0.5% reading |
| Type d’écran | 7-in. High-resolution Color Graphic LCD |
| Sélection de la température | Automatic with ATC temperature sensor, ambient or manual |
| Compensation thermique | Linear (0.00 to 10.00 %/°C), nLFn (non-linear natural water), nLFu (non-linear ultra-pure water), EP/USP or off |
| Type de sonde | Polarographic or optical DO electrode |
| Résolution de la température | 0.1°C, 0.1°F |
| Gamme (rH) | -2000 to 2000 mV |
| Résolution (ionométrie) | 0.0001 minimum, 1 to 5 digits |
| Résolution du coefficient de saturation (RDO) | 0.1, 1% saturation |
| Correction de la pression barométrique | Yes, automatic with built-in barometer or manual |
| Résolution (ion) | 0.0001 minimum, 1 to 5 digits |
| Précision (pH) | ±0.002 pH |
| Garantie | 2 year meter warranty |
| Précision (ionométrie) | ±0.2 mV or ±0.05% of the reading, whichever is greater |
| Précision (rH) | ±0.2 mV or ±0.05% of the reading, whichever is greater |
| Résolution (TDS) | 0.001 ppm or mg/L minimum, auto-ranging, up to 4 digits |
| Précision (OD par mesure polarographique) | ±2% saturation; ±0.02 mg/L or ppm |
| Adaptateur secteur | Universal 100-240 V 50/60 Hz power supply with wall plugs for US/Japan, Euro, UK/Singapore, Australia/New Zealand and China outlets |
| Point isopotentiel | 7.000 pH; 1.000 ion concentration |
| Canaux | 3 |
| Points d’étalonnage (conductivité) | 1 to 5 points |
| Résolution (OD) | 0.1, 1% saturation; 0.01, 0.1 mg/L or ppm |
| Modes de mesure de la salinité | Natural Seawater (ppt), Practical Salinity Units (PSU), or % NaCl |
| Gamme (salinité) | 0.010 to 80.00 ppt; 0.01 to 42.00 PSU; or 0.01 to 400.0% NaCl |
| Méthodes | 10 per channel (30 total) |
| Gamme de facteurs TDS | Linear (0.01 to 10.00), ISO/EN 27888, 442, NaCl |
| Gamme (OD par mesure polarographique) | 0.0 to 600.0% saturation; 0.01 to 90.0 mg/L or ppm |
| Indice IP | IP54 |
| Gamme (résistivité) | 1.0Ω to 100.0 MΩ |
| Gamme (ionométrie) | 0.0001 to 19999 |
| Points de données | 10,000 with Date and Time Stamp |
| Points d’étalonnage (ionométrie) | Up to 5 |
| Précision (conductivité) | ±0.5% reading |
| Gamme de coefficients de saturation (RDO) | 0.0 to 600.0% saturation |
| Étalonnage de la sonde de température | 1 or 2 point temperature offset calibration |
| Constante de cellule | 0.100 cm-1, 0.475 cm-1, 0.550 cm-1, 1.000 cm-1, 10.00 cm-1 or user-defined from 0.001 to 199.9 cm-1 |
| Résolution (salinité) | 0.001 ppt minimum; 0.01 PSU minimum; or 0.01% NaCl minimum, auto-ranging |
| Résolution (résistivité) | 0.1 Ωminimum, auto-ranging |
| Gamme (TDS) | 0.010 ppm to 500.0 ppt (TDS factor of 1.00); or 0.010 mg/L to 500.0 g/L (TDS factor of 1.00) |
| Résolution (OD par mesure polarographique) | 0.1, 1% saturation; 0.01, 0.1 mg/L or ppm |
| Points d’étalonnage | 1 to 5 (pH), 1 (ORP), 1 to 5 (ion), 1 to 5 (conductivity), 1 to 5 (TDS), 1 (salinity), 1 to 2 (DO), 1 (barometer), 1 to 2 (temperature) |
| Modes d’étalonnage | Water-saturated air (100% and 0% saturation), air-saturated water (100% and 0% saturation) or custom concentration value (Winkler) |
| Modes de mesure | pH,ORP,mV,Ion Concentration (ISE),Conductivity,Dissolved Oxygen (mg/L),Temperature,Barometric Pressure |
| Gamme (ion) | 0.0001 to 19999 |
| Gamme (mV) | -2000 to 2000 mV |
| Précision relative du coefficient de saturation (RDO) | ±2% saturation |
| Précision (mV) | ±0.2 mV or ±0.05% of the reading, whichever is greater |
| Résolution (RDO) | 0.1, 1% saturation; 0.01, 0.1 mg/L or ppm |
| Gamme (pH) | -2 to 20 |
| Plage de températures (impériale) | -22.0°F to +266.0°F |
| Gamme (conductivité) | 0.010 μS/cm to 3000 mS/cm |
| Précision (RDO) | ±2% saturation; ±0.02 mg/L or ppm |
METTLER TOLEDO™ SevenExcellence™ S500 pH/ISE Benchtop Meter
The S500 meter performs ion selective (ISE), pH, redox/ORP, and ISFET measurements. It can be expanded with additional modules to measure conductivity, resistivity, DO, salinity, TDS, and BOD. It has an intuitive touchscreen and the ability to create measurement shortcuts.
| Résolution de la température | 0.1°C |
|---|---|
| Résolution (ionométrie) | 0.001 to 1 |
| Précision (pH) | ±0.002 |
| Résolution (TDS) | 0.001 to 1 |
| Langues | Chinese, Chinese (TW), Croatian, Czech, Danish, Dutch, English (GB), English (US), French, German, Hungarian, Indonesian, Italian, Japanese, Korean, Norwegian, Polish, Portuguese (BR), Russian, Slovak, Slovenian, Spanish, Swedish, Thai, Turkish, Vietnamese |
| Canaux | 1 |
| Points d’étalonnage (conductivité) | 13 Pre defined and 20 user defined standard |
| Gamme (salinité) | 0.001 μS/cm to 2000 mS/cm |
| Précision (concentration) | ±0.5% |
| Précision de la température | ±0.1°C |
| Gamme (résistivité) | 0.001 μS/cm to 2000 mS/cm |
| Gamme (ionométrie) | 0 to 999999mg/L |
| Points de données | 20,000 |
| Points d’étalonnage (pH) | Max. 5 points, 8 pre defined and 20 user defined buffer group |
| Points d’étalonnage (ionométrie) | Max. 5 points, 8 pre defined and 20 user defined buffer group |
| Résultats | RS232, USB-A, USB-B, LAN, Mini-LTW, Mini-DIN, BNC, Cinch/RCA |
| Résolution (salinité) | 0.001 to 1 |
| Résolution (résistivité) | 0.001 to 1 |
| Résolution (pH) | 0.001/0.01/0.1 |
| Gamme (TDS) | 0.001 μS/cm to 2000 mS/cm |
| Gamme (mV) | -2000 to 2000 mV |
| Résolution (conductivité) | 0.001 to 1 |
| Mémoire | 250 analyses (20.000 data points) |
| Précision (mV) | ±0.1mV |
| Résolution (mV) | 0.1/1mV |
| Plage de températures (métrique) | -30°C to +130°C |
| Gamme (concentration) | 0.001 to 999999mg/L ppm, 0.0001 to 100mol/L %, 0.001 to 100000mmol/L |
| Gamme (pH) | -2 to 20 |
| Gamme (conductivité) | 0.001 μS/cm to 2000 mS/cm |
| Type d’écran | TFT |
Mettler Toledo™ Seven2Go S7 Conductivity Meter
The Seven2Go portables are engineered to provide users with fast quality data, one-handed operation, and durability, making them ideally suited for mobile applications in the laboratory, at-line, and outdoors.
| Certifications/Conformité | ISO 9001:2000 |
|---|---|
| Compensation thermique | Automatic or Manual |
| Dimensions (L x l x H) | 222 x 70 x 35 mm |
| Résolution (TDS) | 0.01 to 1 |
| Canaux | 1 |
| Modèle | Single channel; conductivity, TDS, salinity |
| Gamme (salinité) | 0.00 to 42 psu |
| Type de batterie | 4 x 1.5 V AA or 1.3 V NiMH acc. |
| Autonomie des piles | 200 to 250 hr. |
| Indice IP | IP67 |
| Gamme (résistivité) | 0.00 to 100.0 Mohm/cm |
| Poids (métrique) | 290 g |
| Précision (conductivité) | ±0.5% |
| Constante de cellule | Manual entry |
| Résolution (salinité) | 0.01 to 0.1 |
| Gamme (TDS) | 0.01 mg/L to 600 g/L |
| Points d’étalonnage | 1 |
| Modes de mesure | Conductivity |
| Entrées | LTW 7-pin (sensor) |
| Résolution (conductivité) | 0.01 |
| Plage de températures (métrique) | -5°C to +105°C |
| Gamme (pH) | 0 to 14 |
| Précision (TDS) | ±0.5% |
| Gamme (conductivité) | 0.01 μS/cm to 1000 mS/cm |
| Précision (salinité) | ±0.5% |
| Type d’écran | Color Graphic |
Thermo Scientific™ Orion™ Versa Star Pro™ Benchtop Meter Without Modules
For the ultimate flexibility, combine the Thermo Scientific™ Orion™ Versa Star Pro™ Benchtop Meter Without Modules with up to four measurement modules to build your ideal system.
Ohaus™ Starter ST20M-C Multi-Parameter Pen Meter
Compact design for fast, convenient electrochemistry reading. Measure conductivity, pH, temperature and salinity with the same meter. IP67, automatic temperature compensation, 3-point calibration and auto-off after 6 minutes of non-use
Thermo Scientific™ Orion Star™ A325 pH/Conductivity Portable Multiparameter Meter
Accurately measure pH, conductivity and temperature with our pH/conductivity portable meter for high performance in challenging field tests.
| Certifications/Conformité | CE, TUV 3-1, FCC Class A |
|---|---|
| Clavier | Comprehensive with menu-specific function keys and dual purpose scroll/shortcut keys |
| Précision (résistivité) | 0.5% of reading ±1 digit |
| Dimensions (L x l x H) | 24cm x 10cm x 6.5cm (9.5 in. x 3.9 in. x 2.6 in.) |
| Langues | English, Spanish, French, Italian, German and Chinese; Portuguese and Korean available with software update |
| Modèle | Orion Star A325 pH/mV/RmV/ORP/Conductivity/TDS/Salinity/Resistivity/Temperature Portable Meter |
| Option de rétro-éclairage | Yes (Selectable) |
| Température (impériale) en fonctionnement | 41°F to 113°F (ambient) |
| Autonomie des piles | 800 hr. |
| Détails de la gestion des données | Transfer single, range or all data points to printer or computer |
| Précision de la température | ±0.1°C |
| Points d’étalonnage (pH) | 1 to 5 |
| Poids (métrique) | 0.5 kg |
| Sorties d’alarme | High/low limit alarm, calibration due alarm |
| Résultats | USB, RS232 |
| Type de fonction d’enregistrement | Automatic data logging with Auto-Read and Timed measure modes; manual data logging with Continuous m |
| Résolution (pH) | 0.1/0.01/0.001 |
| Entrées | BNC (pH or ORP electrode), pin-tip (reference electrode), 8 pin MiniDIN (conductivity sensor with built-in temperature or ATC temperature probe) |
| Étalonnage | pH with calibration editing option, relative mV (RmV), ORP, conductivity with calibration editing op |
| Température (métrique) de référence | 5, 10, 15, 20, 25°C |
| Résolution (conductivité) | 0.001 μS minimum, auto ranging up to 4 significant digits |
| Alimentation électrique | 4 AA batteries (included) or universal AC adapter (sold separately) |
| Gamme (mV relative) | ±2000.0 mV |
| Mémoire | Non-volatile memory preserves data log, calibration log and meter settings |
| Poids (impériale) | 1.2 lb. |
| Température (métrique) en fonctionnement | 5°C to 45°C (ambient) |
| Résolution (mV) | 0.1mV |
| Plage de températures (métrique) | -5.0°C to +105.0°C |
| Gamme d’humidité relative | 5 to 85 %, non-condensing |
| Précision (TDS) | 0.5% of reading ±1 digit |
| Précision (salinité) | 0.5% of reading ±1 digit |
| Type d’écran | LCD Graphic, Backlit |
| Sélection de la température | Manual or automatic with ATC temperature probe |
| Compensation thermique | Linear, nLFn (non-linear ultra pure water), nLFu (non-linear ultra pure degassed water), EP (off with warning) or off |
| Résolution de la température | 0.1°C, 0.1°F |
| Gamme (rH) | ±2000.0 mV |
| Précision (pH) | ±0.002 |
| Garantie | 3 Year Meter |
| Résolution (TDS) | 0.001 ppm minimum, auto ranging up to 4 significant digits |
| Adaptateur secteur | Universal 50-60 Hz, 100-240 VAC power adapter (sold separately, Cat. No. 1010003) |
| Point isopotentiel | 7.000pH |
| Canaux | 2 |
| Points d’étalonnage (conductivité) | Up to 5 |
| Modes de mesure de la salinité | Practical salinity (psu) or natural sea water (ppt) |
| Gamme (salinité) | 0.06 to 80.00 psu, 0.05 to 42.00 ppt |
| Type de batterie | 4 AA (included) |
| Stabilité | Selectable fast, medium, slow or Smart Stability setting; Selectable off or Automatic Smart averaging setting |
| Méthodes | 10 per channel with password protection |
| Gamme de facteurs TDS | Linear (0.02 to 9.99) |
| Indice IP | IP67 |
| Gamme (résistivité) | 2 ohm to 100.0 meg-ohm |
| Points de données | 5000 with Date and Time Stamp |
| Précision (conductivité) | 0.5% of reading ±1 digit > 3 μS; 0.5% of reading ±0.01 μS ≤ 3 μS |
| Étalonnage de la sonde de température | 1 point temperature offset calibration |
| Constante de cellule | 0.001 to 199.9cm-1 |
| Résolution (salinité) | 0.01 psu or 0.01 ppt minimum, auto ranging |
| Résolution (résistivité) | 1 ohm or 0.1 meg-ohm, auto ranging |
| Gamme (TDS) | 0.001 ppm to 200.0 ppt |
| Points d’étalonnage | 1 point relative mV (RmV) mode, 1 point ORP mode |
| Modes de mesure | pH,mV,Relative mV,TDS,ORP with Temperature,Salinity,Conductivity,Resistivity with Temperature |
| Gamme (mV) | ±2000.0 mV |
| Précision (mV) | ±0.2 mV or ±0.05% of reading whichever is greater |
| Gamme (pH) | -2 to 20 |
| Plage de températures (impériale) | 22.0°F to 221.0° F |
| Gamme (conductivité) | 0.001 μS/cm to 3000 mS/cm |
METTLER TOLEDO™ S600 SevenExcellence™ Dissolved Oxygen Benchtop Meter Kit
The S600 meter kit includes a meter, electrode, and accessories to measure disolved oxygen (DO). The meter can be expanded with additional modules to measure pH, conductivity, and ISE. It has an intuitive touchscreen, measurement shortcuts, and can export data to a printer, Excel, or LIMS system.
Thermo Scientific™ Orion™ Versa Star Pro™ pH/Conductivity Multiparameter Benchtop Meter
Get premium performance and flexibility with our benchtop meter with pH and conductivity modules for simultaneous pH, conductivity, and temperature.
| Certifications/Conformité | CE, TUV 3-1, FCC Class A |
|---|---|
| Clavier | Numeric with menu-specific function keys and dual purpose scroll/shortcut keys |
| Précision (résistivité) | 0.5% of reading ±1 digit |
| Dimensions (L x l x H) | 28cm x 24cm x 10cm (11 in. x 9.5 in. x 3.9 in.), modules add ≤ 2cm (0.8 in.) L & H |
| Langues | English, Spanish, French, Italian, German, Chinese, Portuguese and Korean |
| Option de rétro-éclairage | Yes |
| Température (impériale) en fonctionnement | 41°F to 113°F (ambient) |
| Détails de la gestion des données | Transfer single, range or all data points to printer or computer |
| Précision de la température | ±0.1°C |
| Points d’étalonnage (pH) | 1 to 6 |
| Poids (métrique) | 1.2 kg, modules add 0.2 kg each |
| Sorties d’alarme | Set point alarm, high/low limit alarm, calibration due alarm |
| Résultats | USB (2), RS232 |
| Type de fonction d’enregistrement | Automatic data logging with Auto-Read, Timed and Single Shot measure modes; manual data logging with |
| Résolution (pH) | 0.1/0.01/0.001 |
| Entrées | BNC (pH or ORP electrode), pin-tip (reference electrode), 8 pin MiniDIN (ATC temperature probe), 8 pin MiniDIN (conductivity sensor with built-in temperature), two stirrer inputs (stirrer probe) |
| Étalonnage | pH with calibration editing option, relative mV (RmV), ORP, conductivity with calibration editing op |
| Température (métrique) de référence | 5, 10, 15, 20, 25°C |
| Résolution (conductivité) | 0.001 μS minimum, auto ranging up to 4 significant digits |
| Alimentation électrique | Universal AC adapter (included) |
| Gamme (mV relative) | ±2000.0 mV |
| Mémoire | Non-volatile memory preserves data log, calibration log and meter settings |
| Puissance nominale | DC input: 9VDC, 1A |
| Poids (impériale) | 2.5 lb., modules add 0.5 lb. each |
| Température (métrique) en fonctionnement | 5°C to 45°C (ambient) |
| Résolution (mV) | 0.1mV |
| Plage de températures (métrique) | -5.0°C to +105.0°C |
| Gamme d’humidité relative | 5 to 85 %, non-condensing |
| Précision (TDS) | 0.5% of reading ±1 digit |
| Précision (salinité) | 0.5% of reading ±1 digit |
| Type d’écran | Color graphic LCD with user-customizable options |
| Sélection de la température | Manual or automatic with ATC temperature probe |
| Compensation thermique | Linear, nLFn (non-linear ultra pure water), nLFu (non-linear ultra pure degassed water), EP (off with warning) or off |
| Résolution de la température | 0.1°C, 0.1°F |
| Gamme (rH) | ±2000.0 mV |
| Précision (pH) | ±0.002 |
| Garantie | 3 year meter and module warranty |
| Résolution (TDS) | 0.001 ppm minimum, auto ranging up to 4 significant digits |
| Adaptateur secteur | Universal 50-60 Hz, 100-240 VAC power adapter (Cat. No. STARA-PWR) |
| Point isopotentiel | 7.000pH (adjustable) |
| Canaux | 4 (Customizable with modules) |
| Points d’étalonnage (conductivité) | Up to 6 |
| Modes de mesure de la salinité | Practical salinity (psu) or natural sea water (ppt) |
| Gamme (salinité) | 0.06 to 80.00 psu, 0.05 to 42.00 ppt |
| Stabilité | Selectable fast, medium, slow or Smart Stability setting; Selectable off or Automatic Smart averaging setting |
| Méthodes | 10 per channel |
| Gamme de facteurs TDS | Linear (0.02 to 9.99) |
| Indice IP | IP54 |
| Gamme (résistivité) | 2 ohm to 100.0 meg-ohm |
| Points de données | 2000 with Date and Time Stamp |
| Précision (conductivité) | 0.5% of reading ±1 digit > 3 μS; 0.5% of reading ±0.01 μS ≤ 3 μS |
| Étalonnage de la sonde de température | 1 point temperature offset calibration |
| Constante de cellule | 0.001 to 199.9cm-1 |
| Résolution (salinité) | 0.01 psu or 0.01 ppt minimum, auto ranging |
| Résolution (résistivité) | 1 ohm or 0.1 meg-ohm, auto ranging |
| Gamme (TDS) | 0.001 ppm to 200.0 ppt |
| Points d’étalonnage | 1 point relative mV (RmV) mode, 1 point ORP mode |
| Modes de mesure | pH,mV,Relative mV,TDS,ORP with Temperature,Salinity,Conductivity,Resistivity with Temperature |
| Gamme (mV) | ±2000.0 mV |
| Précision (mV) | ±0.2 mV or ±0.05% of reading whichever is greater |
| Gamme (pH) | -2 to 20 |
| Plage de températures (impériale) | 22.0°F to 221.0° F |
| Gamme (conductivité) | 0.001 μS/cm to 3000 mS/cm |