UserName
Omegawax™ capillary GC column may be used for herbicide determination using In-tube Solid-phase microextraction (SPME).
Capillary GC column is also known as open tubular column. The carrier gas flows through the central aperture and is unrestricted throughout the length of the column.
Polar column that is suitable for the analyses of solvents, fatty acid methyl esters (FAMEs), food, flavor and fragrance compounds, alcohols, and aromatics.
Épaisseur du film | 1 μm |
---|---|
Type | Capillary GC |
Matériau | Fused Silica |
Gamme de produits | SUPELCOWAX |
Matériau de remplissage | Poly(ethylene glycol) |
À utiliser avec (application) | Gas Chromatography (GC) |
Revêtement | Fused Silica |
---|---|
Type d’USP | G43 |
Température max. | 240°C |
Phase stationnaire | Rtx™-624 |
Plage de températures | -20°C to +240°C |
À utiliser avec (application) | Volatile Organic Pollutants Analysis |
Give greater stability and inertness at elevated temperatures and when working with highly active compounds with Thermo Scientific™ TraceGOLD™ TG-5MT Metal GC Columns.
Type d’USP | G27, G36 |
---|---|
Polarité | Low-Polar |
Température max. | 330/350°C (Standard Columns), 430°C (Metal Columns) |
Produce consistent results with this low-bleed, stable column produces.
Type d’USP | G14, G15, G16, G20, G39 |
---|---|
Granulométrie | 0.25 μm |
Phase stationnaire | TraceGOLD™ TG-WAXMS |
Plage de températures | 40°C°C to 260°C |
À utiliser avec (application) | GC/MS |
Perform fast, highly sensitive analysis of multi-class contaminants with Thermo Scientific™ TraceGOLD™ TG-Contaminants GC columns.
Optimize volatile organics analysis with this low-bleed, midpolarity GC column with high thermal stability.
Extend column life with the integrated guard of the this GC column.
Longueur (métrique) | 30 m |
---|---|
Type d’USP | G2 |
Polarité | Non-Polar |
Température max. | 330/350°C (Standard Columns), 430°C (Metal Columns) |
Phase stationnaire | TraceGOLD™ TG-1 MS |
À utiliser avec (application) | GC/MS for Optimal Signal-to-Noise Ratio, Sensitivity, and MS Integrity |
Extend column lifetime and get more consistent results over a longer period of time.
Type d’USP | G27, G36 |
---|---|
Polarité | Low-Polar |
Température max. | 330/350°C (Standard Columns), 430°C (Metal Columns) |
Phase stationnaire | TraceGOLD™ TG-5 MS |
Plage de températures | -60°C to +330/350°C |
À utiliser avec (application) | Active Compounds Analysis,GC/MS for Analysis of Active Compounds |
The Thermo Scientific™ TraceGOLD™ TG-5SILMS Guard GC Columns with SafeGuard offer the benefit of an integrated SafeGuard for extended column lifetime.
Type d’USP | G27, G36 |
---|---|
Polarité | Low-Polar |
Température max. | 330/350°C |
Phase stationnaire | TraceGOLD™ TG-5 SILMS |
À utiliser avec (application) | GC/MS Applications Using Ion-Trap Systems,GC/MS for Polycyclic Aromatics, Phthalates, Phenols, Amines, and Organophosphates,GC/MS for Hydrocarbons Including Chlorinated Hydrocarbons |
Ensure excellent column-to-column reproducibility using the Thermo Scientific™ TraceGOLD™ TG-WaxMT GC Columns.
Type d’USP | G14, G15, G16, G20, G39 |
---|---|
Polarité | Polar |
Température max. | 260°C |
Phase stationnaire | TraceGOLD™ TG-WAXMS |
Plage de températures | 40°C°C to 260°C |
À utiliser avec (application) | GC for EPA Method 603 for Acrolein/Acrylonitrile,GC for Fatty Acid Methyl Esters (FAMEs), Flavor Compounds, Essential Oils, Amines, Solvents, and Xylene Isomers |
Optimize volatile organics analysis with this low-bleed, midpolarity GC column with high thermal stability.
Optimize volatile organics analysis with this low-bleed, midpolarity GC column with high thermal stability.
Highly specialized column that offers both polar and polarizable features.