Filtered Search Results
MilliporeSigma™ Supelco™ Ascentis™ RP-Amide HPLC Column, 5 μm Particle Size
Ascentis™ RP-Amide is a new generation ultra low bleed, embedded polar group (EPG) phase that provides orthogonal selectivity and increased resolution for HPLC and LC-MS analysis of polar compounds. The Ascentis™ RP-Amide is the first choice in embedded polar group HPLC phases.
| Pore Size | 100 Å |
|---|---|
| Particle Size | 5 μm |
| Stationary Phase | Amide, Alkyl |
| Phase | Reversed Phase |
| Matrix | Amide, Alkyl Phase/Fused-Core Particle Platform |
| Endcapped | Yes |
| pH | 2 to 8 |
| Technique | Fused-Core HPLC |
| Surface Area | 450 m2/g |
| Product Line | Ascentis |
TSKgel™ ODS-120T HPLC Column, 5 μm Particle Size, Sold by MilliporeSigma™ Supelco™
Shipped in 70% methanol, 30% water
TSKgel™ SuperH6000 HPLC Column, 5 μm Particle Size, Sold by MilliporeSigma™ Supelco™
Packed with rigid, porous polymer beads and used for the non-aqueous separation of polymers with molecular weights less than 40,000,000 Da (Estimate).
TSKgel™ SuperQ-5PW HPLC Column, 10 μm Particle Size, Sold by MilliporeSigma™ Supelco™
TSKgel SuperQ-5PW Columns are packed with porous hydrophilic polymer beads which are modified with a strong anion exchanger. Columns are used for the separation and analysis of proteins, oligonucleotides, and other biologically active molecules.
| Particle Size | 10 μm |
|---|---|
| Solvents | ≤ 20% Organic Solvent |
| Stationary Phase | Ammonium Ion (Quaternary Phase) |
| Temperature | ≤45°C |
| Length (Metric) | 7.5 cm |
| Ion Exchange Group | Cl- |
| pH | 2 to 12 |
| Technique | Anion Exchange |
| Max. Pressure | 200 bar |
| Product Line | TSKgel |
| USP Type | L23 |
TSKgel™ Ether-5PW HPLC Column, 10 μm Particle Size, Sold by MilliporeSigma™ Supelco™
An excellent choice for separating hydrophobic molecules such as membrane proteins, or monoclonal antibodies such as IgG or IgM.
| Particle Size | 10 μm |
|---|---|
| Solvents | ≤ 50% Organic Solvent |
| Stationary Phase | Ether |
| Temperature | 10°C to 50°C |
| Matrix | Ether Phase/Hydroxylated Methacrylic Polymer |
| pH | 2 to 12 |
| Technique | HIC HPLC |
| Product Line | TSKgel |
TSKgel™ SuperHZM-M HPLC Column, 3 μm Particle Size, Sold by MilliporeSigma™ Supelco™
TSKgel™ SuperHZM-M Mixed-Bed Columns are packed with rigid, porous, polymer beads each having a varying mean pore diameter. They are used for the non-aqueous separation of solvent-soluble high molecular weight polymers less than 4,000,000 Da.
| Particle Size | 3 μm |
|---|---|
| Stationary Phase | Polystyrene-divinylbenzene |
| Temperature | 80°C |
| Length (Metric) | 15 cm |
| Material | Stainless Steel |
| Technique | SEC |
| Max. Pressure | 20 bar |
| Product Line | TSKgel |
TSKgel™ SuperAW2500 HPLC Column, 4 μm Particle Size, Sold by MilliporeSigma™ Supelco™
Packed with rigid, porous, polymer beads which show minimal shrinkage or swelling in different solvent systems. Used for the separation of polymers that are soluble in polar organic solvents. Exclusion Limit (DMF): Polyethylene Oxide 2,000 Da.
TSKgel™ ODS-80Ts QA HPLC Column, 5 μm Particle Size, Sold by MilliporeSigma™ Supelco™
TSKgel™ ODS-80Ts QA columns were developed specifically for use by QA/QC departments that require highly reproducible separations.
| Shipping Condition | Shipped in 70% Methanol, 30% Water |
|---|---|
| Solvents | 0-100% Organic Solvent |
| Stationary Phase | C18 (octadecyl) |
| Temperature | 10°C to 50°C |
| Phase | Reversed Phase |
| Endcapped | Yes |
| Material | Stainless Steel |
| Particle Size | 5 μm |
| Carbon Load | 15% |
| Matrix | C18 (octadecyl) Phase/Spherical Silica |
| pH | 2 to 7.5 |
| Particle Shape | Sphere |
| Product Line | TSKgel |
| USP Type | L1 |
TSKgel™ Alpha-2500 HPLC Column, 7 μm Particle Size, Sold by MilliporeSigma™ Supelco™
Packed with rigid, porous polymer beads which show minimal shrinkage or swelling in different solvent systems. Columns are best used for the separation of polymers that are soluble in polar organic solvents.
TSKgel™ GMHHR-H HT HPLC Columns, 13 μm Particle Size, Sold by MilliporeSigma™ Supelco™
TSKgel HT (High Temperature) Columns for the analysis of organic-soluble polymers at temperatures up to 140°C.
TSKgel™ Super-Phenyl HPLC Column, 2.3 μm Particle Size, Sold by MilliporeSigma™ Supelco™
TSKgel™ Super-Phenyl Columns are packed with monodispersed 2 μm (nominal, mean particle size is 2.3 μm) spherical silica particles covalently bonded with phenyl groups.
| Shipping Condition | Shipped in 50% Acetonitrile, 50% Water |
|---|---|
| Particle Size | 2.3 μm |
| Solvents | 0-100% Organic Solvent |
| Carbon Load | 3% |
| Stationary Phase | Phenyl |
| Temperature | 10°C to 50°C |
| Phase | Reversed Phase |
| Matrix | Phenyl Phase/Silica Particle Platform |
| Endcapped | Yes |
| pH | 2 to 7.5 |
| Surface Area | 100 m2/g |
| Product Line | TSKgel |
Thermo Scientific™ BetaSil™ C6 HPLC Columns, 5μm Particle Size
High surface area with high bonded phase coverage
| Pore Size | 100 Å |
|---|---|
| Particle Size | 5 μm |
| Carbon Load | 11% |
| Stationary Phase | C6 |
| Phase | Reversed Phase |
| Endcapped | Yes |
| Column Type | Reversed Phase |
| USP Type | L15 |
| Column Format | Analytical Column |
MilliporeSigma™ Supelco™ Ascentis™ Express 90 Å Biphenyl HPLC Column, 5 μm Particle Size
Ascentis™ Express 90 Å Biphenyl columns can be used for basic, acidic, or neutral compounds with alternate selectivity from C18 and is especially useful for separating peaks that elute early on C18 and other phenyl phases.
| Pore Size | 90 Å |
|---|---|
| Particle Size | 5 μm |
| Stationary Phase | Biphenyl (Dimethylbiphenyl) Bonding |
| Phase | Reversed Phase |
| Matrix | Biphenyl (Dimethylbiphenyl) Bonding Phase/Fused-Core Particle Platform |
| Endcapped | Yes |
| pH | 2 to 9 |
| Technique | Fused-Core HPLC |
| Surface Area | 90 m2/g |
| Product Line | Ascentis |
Thermo Scientific™ EASY-Spray™ PepMap™ Neo UHPLC Columns
Separate challenging peptide mapping samples with Thermo Scientific™ EASY-Spray™ PepMap™ Neo UHPLC columns.
| Pore Size | 100 Å |
|---|---|
| Stationary Phase | C18 |
| Temperature | 60°C |
| Phase | Reversed Phase |
| Endcapped | Yes |
| Column Type | Reversed Phase |
| For Use With (Application) | Bottom-up Proteomics, LC-MS |
| Surface Area | 450 m2/g |
| Max. Pressure | 22,000 psi (1500 bar) |
| Column Format | Analytical Column, EASY-Spray™ |
| Particle Size | 2 μm |
| Carbon Load | 15% |
| Packing Material | Spherical, Fully Porous, Ultrapure Silica |
| Diameter (Metric) | 75 μm |
| pH | 2 to 8 |
| Product Line | Easy Spray |
| USP Type | L1 |
MilliporeSigma™ Supelco™ Ascentis™ Express Peptide ES-C18 HPLC Column, 2.7 μm Particle Size
Ascentis™ Express Peptide ES-C18 columns are specifically engineered to separate higher molecular weight compounds such as peptides and small proteins.
| Pore Size | 160 Å |
|---|---|
| Particle Size | 2.7 μm |
| Stationary Phase | C18 (octadecyl) |
| Phase | Reversed Phase |
| Matrix | C18 (octadecyl) Phase/Fused-Core Particle Platform |
| Endcapped | No |
| pH | 1 to 9 |
| Technique | Fused-Core HPLC |
| Surface Area | 80 m2/g |
| Product Line | Ascentis |