Real Time PCR Master Mixes
- (4)
- (128)
- (105)
- (1)
- (31)
- (13)
- (5)
- (16)
- (13)
- (203)
- (7)
- (28)
- (5)
- (3)
- (194)
- (62)
- (52)
- (17)
- (1)
- (2)
- (28)
- (4)
- (19)
- (39)
- (2)
- (2)
- (36)
- (96)
- (101)
- (165)
- (1)
- (7)
Filtered Search Results
Applied Biosystems™ TaqPath™ ProAmp™ Master Mix
TaqPath ProAmp Master Mix is for high-throughput genotyping and copy number variation protocols requiring uncompromising reliability and accuracy, even in the presence of inhibitors commonly found in clinical samples.
| Shipping Condition | Wet Ice |
|---|---|
| Content And Storage | Store at 2°C to 8°C in the dark. |
| For Use With (Application) | Genotyping |
| PCR Method | qPCR |
| Multiplex Capability | 4-plex |
| Detection Method | Primer-probe |
| Includes | dUTP, UNG/UDG |
| Thermostability | 72 hr., Assembled Reaction |
| Polymerase | Taq DNA Polymerase |
| Product Type | qPCR Master Mix |
| Passive Reference Dye | ROX (Pre-mixed) |
| For Use With (Equipment) | 7500 Fast System, QuantStudio 12k Flex, QuantStudio 3, QuantStudio 5, QuantStudio 6 Flex, QuantStudio 7 Flex, ViiA 7 System, ViiA 7 Dx, QuantStudio Dx, StepOnePlus System, StepOne System |
| Reaction Speed | Fast or Standard |
| Inhibitor Tolerance (Simple) | Very High |
| Target Specificity | cDNA or gDNA only |
| Product Line | TaqPath |
Applied Biosystems™ Absolute Q™ DNA Digital PCR Master Mix (5X)
Applied Biosystems Absolute Q DNA Digital PCR Master Mix (5X) is optimized for use with the QuantStudio Absolute Q Digital PCR System and Applied Biosystems digital PCR (dPCR) assays in a simple workflow with minimal processing steps.
Applied Biosystems™ Absolute Q™ 1-step RT-dPCR Master Mix (4X)
Applied Biosystems Absolute Q 1-step RT-dPCR Master Mix (4X) is optimized for use with the QuantStudio Absolute Q Digital PCR System in a simple workflow with minimal processing steps.
Applied Biosystems™ TaqMan™ Fast Advanced Master Mix for qPCR, no UNG
TaqMan Fast Advanced Master Mix delivers accurate quantification and dependability in a short time.
| Shipping Condition | Wet Ice |
|---|---|
| GC-Rich PCR Performance | High |
| Fidelity (vs. Taq) | 2 X |
| Form | Liquid |
| Concentration | 2X |
| For Use With (Application) | Gene Expression,DNA Quantification,Presence/Absence |
| PCR Method | qPCR |
| Multiplex Capability | Duplex |
| Detection Method | Primer-probe |
| Includes | dUTP |
| Thermostability | 72 hr., Assembled Reaction |
| Polymerase | AmpliTaq Fast DNA Polymerase |
| Product Type | Fast Advanced Master Mix |
| Passive Reference Dye | ROX (Pre-mixed) |
| For Use With (Equipment) | 7500 Fast System, 7500 System, 7900HT System, QuantStudio™ 12k Flex, QuantStudio™ 3, QuantStudio™ 5, QuantStudio™ 6 Flex, QuantStudio™ 6 Pro, QuantStudio™ 7 Flex, QuantStudio™ 7 Pro, StepOne™, StepOnePlus™, ViiA™ 7 System |
| Sample Type | DNA |
| Reaction Speed | Fast or Standard |
| Inhibitor Tolerance (Simple) | High |
| Target Specificity | cDNA or gDNA only |
| Product Line | TaqMan |
Applied Biosystems™ TaqPath™ DuraPlex™ 1-Step RT-qPCR Master Mix, no ROX™
Applied Biosystems TaqPath DuraPlex 1-Step RT-qPCR Master Mix is a benchtop-stable, single-tube master mix optimized for rapid, sensitive, and reproducible detection of viral and bacterial pathogens even in the presence of PCR inhibitors.
| Shipping Condition | Dry Ice |
|---|---|
| GC-Rich PCR Performance | Medium |
| Content And Storage | Store at –15 to –25°C. Store at room temperature (24°C) for 1 week after first use and 4°C for 1 month after first use. |
| Form | Liquid |
| For Use With (Application) | Microbial Detection,Gene Expression,DNA Quantification,Presence/Absence |
| PCR Method | 1-step RT-qPCR |
| Multiplex Capability | Up to 6-plex |
| Detection Method | Primer-probe |
| Includes | dUTP |
| Thermostability | 8 hr., Assembled Reaction |
| Polymerase | Applied Biosystems™ AmpliTaq™ DNA Polymerase with Hot Start |
| Format | Single-Tube |
| Passive Reference Dye | None |
| Reaction Speed | Fast or Standard |
| Inhibitor Tolerance (Simple) | High |
| Target Specificity | RNA only, Both RNA and DNA |
| Hot Start | Antibody-based |
| Shelf Life | Two years from date of manufacture, with guaranteed minimum shelf life of ≥1 year upon receipt |
| Product Line | TaqPath |
Applied Biosystems™ Fast SYBR™ Green Master Mix
Designed for speed, SYBR™ Green Master Mix provides a fast, reliable, and cost-effective solution for RT-PCR application without compromising sensitivity, specificity, dynamic range, or PCR efficiency.
| GC-Rich PCR Performance | High |
|---|---|
| Purity or Quality Grade | UP (Ultra Pure) |
| Concentration | 2X |
| For Use With (Application) | Gene Expression |
| PCR Method | qPCR |
| Detection Method | SYBR |
| Polymerase | AmpliTaq Fast DNA Polymerase, AmpliTaq Fast UP |
| Product Type | Real Time PCR SYBR Master Mix |
| Passive Reference Dye | ROX (Pre-mixed) |
| For Use With (Equipment) | 7500 Fast System, 7900HT Fast System, StepOne™, Fast Mode, StepOnePlus™, Fast Mode |
| Sample Type | DNA (Genomic), cDNA |
| Reaction Speed | Fast |
| Label or Dye | SYBR Green |
| Product Line | SYBR |
Applied Biosystems™ PowerUp™ SYBR™ Green Master Mix for qPCR
Pre-formulated, optimized, universal 2X master mix for real-time PCR workflows.
| Shipping Condition | Wet Ice |
|---|---|
| Concentration | 2X |
| For Use With (Application) | Gene Expression |
| PCR Method | qPCR |
| Multiplex Capability | Single-plex |
| Detection Method | SYBR |
| Includes | dUTP, UNG/UDG |
| Thermostability | 72 hr., Assembled Reaction |
| Polymerase | Dual-Lock Taq DNA Polymerase |
| Format | Tube |
| Product Type | Real Time PCR SYBR Master Mix |
| Passive Reference Dye | ROX (Pre-mixed) |
| For Use With (Equipment) | 7500 Fast System, 7500 System, 7900HT System, QuantStudio 12k Flex, QuantStudio 3, QuantStudio 5, QuantStudio 6 Flex, QuantStudio 6 Pro, QuantStudio 7 Pro, QuantStudio 7 Flex, StepOne, StepOnePlus, ViiA 7 System, Roche LightCycler PRO System, Bio-Rad CFX Opus 96 Real-Time PCR System |
| Sample Type | DNA |
| Reaction Speed | Fast or Standard |
| Inhibitor Tolerance (Simple) | Medium |
| Target Specificity | cDNA or gDNA only |
| Product Line | PowerUP, SYBR |
Applied Biosystems™ TaqPath™ qPCR Master Mix, CG
TaqPath qPCR Master Mix, CG, is a 2X formulation designed for gene expression and miRNA analysis. It contains thermostable Fast DNA polymerase, uracil-N-glycosylase (UNG), dNTPs with dUTP, ROX dye (passive reference), and optimized buffer components for maximum robustness and reproducibility.
| Content And Storage | Store at 2°C to 8°C in the dark. |
|---|---|
| Form | Liquid |
| Concentration | 2X |
| For Use With (Application) | Gene Expression,Microbial Detection,DNA Quantification,Presence/Absence,miRNA analysis |
| PCR Method | qPCR |
| Multiplex Capability | Duplex |
| Detection Method | Primer-probe |
| Includes | dUTP, UNG/UDG |
| Thermostability | 48 hr., Assembled Reaction |
| Polymerase | Fast DNA Polymerase |
| Sensitivity | Down to 10 copies |
| Format | Bottle |
| Product Type | qPCR Master Mix |
| Passive Reference Dye | ROX (Pre-mixed) |
| For Use With (Equipment) | QuantStudio Dx, 7500 Fast Dx, Roche LightCycler PRO System, Bio-Rad CFX Opus 96 Real-Time PCR System |
| Sample Type | cDNA, DNA |
| Reaction Speed | Fast or Standard |
| Inhibitor Tolerance (Simple) | High |
| Target Specificity | cDNA or gDNA only |
| Hot Start | Built-In Hot Start |
| Product Line | TaqPath |
Applied Biosystems™ SYBR™ Green Universal Master Mix
Everything needed for SYBR™ Green dye-based PCR amplification and detection in a convenient, single-tube format.
| Polymerase | AmpliTaq Gold DNA Polymerase |
|---|---|
| GC-Rich PCR Performance | High |
| Format | Tube |
| Product Type | Real Time PCR SYBR Master Mix |
| Passive Reference Dye | ROX (Pre-mixed) |
| Reaction Speed | Standard |
| Label or Dye | SYBR Green |
| Concentration | 2X |
| For Use With (Application) | Gene Expression |
| PCR Method | qPCR |
| Product Line | SYBR |
| Detection Method | SYBR |
Applied Biosystems™ TaqMan™ Fast Virus 1-Step Multiplex Master Mix for qPCR (No ROX)
TaqMan Fast Virus 1-Step Multiplex Master Mix (No ROX) is designed to enable dye flexibility for multiplexing up to four different RNA/DNA targets for high-throughput RT-qPCR.
| Shipping Condition | Dry Ice |
|---|---|
| Concentration | 4X |
| For Use With (Application) | Microbial Detection,Gene Expression,DNA Quantification,Presence/Absence |
| PCR Method | 1-step RT-qPCR |
| Multiplex Capability | Up to 4-plex |
| Detection Method | Primer-probe |
| Thermostability | Not Applicable |
| Passive Reference Dye | None |
| For Use With (Equipment) | 7500 Fast System, 7500 System, 7900HT System, QuantStudio 12k Flex, QuantStudio 3, QuantStudio 5, QuantStudio 6 Flex, QuantStudio 6 Pro, QuantStudio 7 Flex, QuantStudio 7 Pro, StepOne, StepOnePlus, ViiA 7 System, Roche LightCycler PRO System, Bio-Rad CFX Opus 96 Real-Time PCR System |
| Sample Type | RNA, DNA |
| Reaction Speed | Fast or Standard |
| Inhibitor Tolerance (Simple) | High |
| Target Specificity | RNA only, Both RNA and DNA |
| Hot Start | Built-In Hot Start |
Applied Biosystems™ PowerTrack™ SYBR Green Master Mix for qPCR
PowerTrack SYBR Green Master Mix is a pre-formulated, optimized, universal 2X master mix for real-time PCR workflows with built-in visual dye–based indicators for accurate reaction set up.
| Shipping Condition | Dry Ice |
|---|---|
| Content And Storage | • PowerTrack SYBR Green Master Mix • 40X Yellow Sample Buffer Store at -20±5°C in the dark. |
| Concentration | 2X |
| For Use With (Application) | Gene Expression,Microbial Detection |
| PCR Method | qPCR |
| Multiplex Capability | Single-plex |
| Detection Method | SYBR |
| Includes | dUTP, UNG/UDG |
| Thermostability | 8 hr., Assembled Reaction |
| Polymerase | Taq DNA Polymerase |
| Format | Tube |
| Product Type | Real Time PCR SYBR Master Mix |
| Passive Reference Dye | ROX (Pre-mixed) |
| For Use With (Equipment) | 7500 Fast System, 7500 System, 7900HT Fast System, 7900HT System, QuantStudio 3, QuantStudio 5, QuantStudio 6 Flex, QuantStudio 6 Pro, QuantStudio 7 Flex, QuantStudio 7 Pro, QuantStudio 12K Flex, Bio-Rad CFX Connect, Bio-Rad CFX384 Touch, Bio-Rad CFX96 Touch, BioRad CFX96, BioRad iCycler iQ, BioRad iQ5, BioRad MyiQ, ViiA 7 System, StepOne System, MJ Chromo4, MJ Opticon, StepOnePlus System, Roche LightCycler 480, Stratagene Mx3000P, Stratagene Mx3005P, Stratagene Mx4000 |
| Sample Type | DNA |
| Reaction Speed | Fast or Standard |
| Inhibitor Tolerance (Simple) | High |
| Target Specificity | cDNA or gDNA only |
| Product Line | Applied Biosystems |
Applied Biosystems™ TaqMan™ Universal PCR Master Mix, no AmpErase™ UNG
TaqMan™ Universal PCR Master Mix, No AmpErase™ UNG is the ideal reagent solution when you need a Master Mix for multiple 5' nuclease DNA applications.
| Shipping Condition | Wet Ice |
|---|---|
| Polymerase | AmpliTaq Gold DNA Polymerase |
| GC-Rich PCR Performance | High |
| Product Type | Universal PCR Master Mix |
| Passive Reference Dye | ROX (Pre-mixed) |
| For Use With (Equipment) | 7000 System, 7300 System, 7500 System, 7700 System, 7900HT System,Applied Biosystems StepOnePlus™ Fast Real-Time PCR System, GeneAmp 9600, StepOne™, Standard Mode, StepOnePlus™, Standard Mode |
| Sample Type | DNA (Genomic), cDNA |
| Reaction Speed | Standard |
| For Use With (Application) | Gene Expression,Genotyping,miRNA analysis |
| PCR Method | qPCR |
| Product Line | TaqMan |
| Detection Method | Primer-probe |
Applied Biosystems™ TaqMan™ Fast Advanced Master Mix for qPCR
TaqMan Fast Advanced Master Mix delivers accurate quantification and dependability in less time on an array of qPCR instrument platforms.
| Shipping Condition | Wet Ice |
|---|---|
| GC-Rich PCR Performance | High |
| Fidelity (vs. Taq) | 2 X |
| Form | Liquid |
| Concentration | 2X |
| For Use With (Application) | Gene Expression,DNA Quantification,Presence/Absence,miRNA analysis |
| PCR Method | qPCR |
| Multiplex Capability | Duplex |
| Detection Method | Primer-probe |
| Includes | dUTP, UNG/UDG |
| Thermostability | 72 hr., Assembled Reaction |
| Polymerase | AmpliTaq Fast DNA Polymerase |
| Product Type | Fast Advanced Master Mix |
| Passive Reference Dye | ROX (Pre-mixed) |
| For Use With (Equipment) | 7500 Fast System, 7500 System, 7900HT System, QuantStudio 12k Flex, QuantStudio 3, QuantStudio 5, QuantStudio 6 Flex, QuantStudio 6 Pro, QuantStudio 7 Flex, QuantStudio 7 Pro, StepOne, StepOnePlus, ViiA 7 System, Roche LightCycler PRO System, Bio-Rad CFX Opus 96 Real-Time PCR System |
| Sample Type | DNA (Genomic), cDNA |
| Reaction Speed | Fast |
| Inhibitor Tolerance (Simple) | High |
| Target Specificity | cDNA or gDNA only |
| Product Line | TaqMan |
Applied Biosystems™ TaqMan™ Gene Expression Master Mix
Precise and reliable real-time qPCR quantification over 9 logs of linear dynamic range with Applied Biosystems™ TaqMan™ Gene Expression Master Mix.
| Polymerase | AmpliTaq Gold DNA Polymerase |
|---|---|
| Purity or Quality Grade | UP (Ultra Pure) |
| Passive Reference Dye | ROX (Pre-mixed) |
| For Use With (Equipment) | 7000 System, 7300 System, 7500 System, 7900HT System, Applied Biosystems StepOnePlus™ Fast Real-Time PCR SystemStepOne™, Standard Mode, StepOnePlus™, Standard Mode |
| Sample Type | DNA (Genomic), cDNA |
| Reaction Speed | Standard |
| For Use With (Application) | Gene Expression |
| PCR Method | qPCR |
| Product Line | TaqMan |
| Detection Method | Primer-probe |
Applied Biosystems™ TaqMan™ Environmental Master Mix 2.0
Accurate, real-time PCR-based pathogen detection in the presence of high levels of inhibitors.
| Purity or Quality Grade | UP (Ultra Pure) |
|---|---|
| Concentration | 2X |
| For Use With (Application) | Gene Expression,Genotyping,Pathogen Detection,Virus Detection |
| PCR Method | qPCR |
| Detection Method | Primer-probe |
| Polymerase | AmpliTaq Gold DNA Polymerase |
| Format | Bottle |
| Product Type | qPCR Master Mix |
| Passive Reference Dye | ROX (Pre-mixed) |
| For Use With (Equipment) | 7000 System, 7300 System, 7500 Fast System, 7500 System, 7900HT Fast System, 7900HT System, StepOne™, Standard Mode |
| Sample Type | Environmental Sample, Food |
| Reaction Speed | Standard |
| Hot Start | Built-In Hot Start |
| Product Line | TaqMan |