Industrial Hygiene and Environmental Monitoring
Résultats de la recherche filtrée
| Longueur (métrique) | 20cm |
|---|---|
| Hauteur (impériale) | 2.25 in. |
| Type de produit | Beta sample box |
| Capacité | 36 Tubes |
| Matériau | Acrylic |
| Dimensions (L x l x H) | 8 x 4 x 2.25 in. (20 x 10 x 5.7cm) |
| À utiliser avec (application) | To allow icing of samples if desired, store and transport samples |
| Longueur (impériale) | 8 in. |
| Couleur | Clear |
| Largeur (métrique) | 10cm |
| Hauteur (métrique) | 5.7cm |
| Épaisseur (impériale) | 0.37 in. |
| Comprend | Radiation label, non-skid feet |
| Largeur (impériale) | 4 in. |
Fisherbrand™ Mobile Beta Storage Container
Suitable for beta protection and industrial mobile storage.
Fisherbrand™ Traceable™ Sound Level Meter
Meter receives sound through a 1/2 in. condenser microphone.
Thermo Scientific™ TVA2020 Toxic Vapor Analyzer - Dual FID/PID with Enhanced & Sampling Probes
Quickly detect organic and inorganic compounds in demanding applications such as Method 21 monitoring and site remediation.
| Hauteur (impériale) | 11.5 in. |
|---|---|
| Certifications/Conformité | USA: Class I, Division 1, Groups A,B,C,D T3; Canada: Class I, Zone 1, Ex db ib IIC T3 Gb; ATEX: CE0359 Ex II 2 G Ex db ib IIC T3 Gb; IECEx: Ex db ib IIC T3 Gb |
| Précision | FID Instrument - ±10% of reading or ±1.0 ppm, whichever is greater, from 1.0 to 10,000 ppm; PID Instrument - ±20 % of reading or ±0.5 ppm, whichever is greater, from 0.5 to 500 ppm |
| Garantie | One year from date of shipment |
| Temps de réponse | FID: Less than 3.5 seconds for 90% of final value, using 10,000 ppm of methane; PID: Less than 3.5 seconds for 90% of final value, using 500 ppm of isobutylene |
| Fréquence | 50/60 Hz |
| Type de batterie | Lithium-ion |
| Interface série | USB |
| Profondeur (impériale) | 4 in. |
| Tension | 120 V |
| Largeur (impériale) | 9 in. |
| Reproductibilité | FID: ±2% at 500 ppm of methane; PID: ±1% at 100 ppm of isobutylene |
| Points de données | Auto mode - 1 per second to 1 per 999 minutes, user selectable; VOC or FE Mode - 2 to 30 seconds, user selectable |
| Composants mesurés | Most Organic and Inorganic Compounds |
| Débit | 1 L/min., nominal at sample probe inlet |
| Contraintes informatiques | USB port, Windows XP operating system or higher |
| Limites de détection | FID: 0.5 ppm of methane; PID: 0.5 ppm of isobutylene |
| Concentration | FID: 0 to 30,000 ppm (methane); PID: 0 to 2000 ppm (isobutylene) |
| Largeur (métrique) | 22.9 cm |
| Hauteur (métrique) | 29.2 cm |
| Combustible | 99.99% H2 for FID |
| Autonomie en mode portable | Minimum 10 hours |
| Plage de températures (métrique) | -10°C to 45°C |
| Autonomie de la batterie | 10 hours at 0°C |
| Plage de températures (impériale) | 14°F to 113°F |
| Type de détecteur | Dual Configured with FID and PID |
| Profondeur (métrique) | 10.2 cm |
Thermo Scientific™ TVA2020 Toxic Vapor Analyzer - Dual FID/PID (No Probes)
Quickly detect organic and inorganic compounds in demanding applications such as Method 21 monitoring and site remediation.
| Hauteur (impériale) | 11.5 in. |
|---|---|
| Certifications/Conformité | USA: Class I, Division 1, Groups A,B,C,D T3; Canada: Class I, Zone 1, Ex db ib IIC T3 Gb; ATEX: CE0359 Ex II 2 G Ex db ib IIC T3 Gb; IECEx: Ex db ib IIC T3 Gb |
| Précision | FID Instrument - ±10% of reading or ±1.0 ppm, whichever is greater, from 1.0 to 10,000 ppm; PID Instrument - ±20 % of reading or ±0.5 ppm, whichever is greater, from 0.5 to 500 ppm |
| Garantie | One year from date of shipment |
| Temps de réponse | FID: Less than 3.5 seconds for 90% of final value, using 10,000 ppm of methane; PID: Less than 3.5 seconds for 90% of final value, using 500 ppm of isobutylene |
| Fréquence | 50/60 Hz |
| Type de batterie | Lithium-ion |
| Interface série | USB |
| Profondeur (impériale) | 4 in. |
| Tension | 120 V |
| Largeur (impériale) | 9 in. |
| Reproductibilité | FID: ±2% at 500 ppm of methane; PID: ±1% at 100 ppm of isobutylene |
| Points de données | Auto mode - 1 per second to 1 per 999 minutes, user selectable; VOC or FE Mode - 2 to 30 seconds, user selectable |
| Composants mesurés | Most Organic and Inorganic Compounds |
| Débit | 1 L/min., nominal at sample probe inlet |
| Contraintes informatiques | USB port, Windows XP operating system or higher |
| Limites de détection | FID: 0.5 ppm of methane; PID: 0.5 ppm of isobutylene |
| Concentration | FID: 0 to 30,000 ppm (methane); PID: 0 to 2000 ppm (isobutylene) |
| Largeur (métrique) | 22.9 cm |
| Hauteur (métrique) | 29.2 cm |
| Combustible | 99.99% H2 for FID |
| Autonomie en mode portable | Minimum 10 hours |
| Plage de températures (métrique) | -10°C to 45°C |
| Autonomie de la batterie | 10 hours at 0°C |
| Plage de températures (impériale) | 14°F to 113°F |
| Type de détecteur | Dual Configured with FID and PID |
| Profondeur (métrique) | 10.2 cm |
Thermo Scientific™ TVA2020 Toxic Vapor Analyzer - Dual FID/PID with Sampling Probe
Quickly detect organic and inorganic compounds in demanding applications such as Method 21 monitoring and site remediation.
| Hauteur (impériale) | 11.5 in. |
|---|---|
| Certifications/Conformité | USA: Class I, Division 1, Groups A,B,C,D T3; Canada: Class I, Zone 1, Ex db ib IIC T3 Gb; ATEX: CE0359 Ex II 2 G Ex db ib IIC T3 Gb; IECEx: Ex db ib IIC T3 Gb |
| Précision | FID Instrument - ±10% of reading or ±1.0 ppm, whichever is greater, from 1.0 to 10,000 ppm; PID Instrument - ±20 % of reading or ±0.5 ppm, whichever is greater, from 0.5 to 500 ppm |
| Garantie | One year from date of shipment |
| Temps de réponse | FID: Less than 3.5 seconds for 90% of final value, using 10,000 ppm of methane; PID: Less than 3.5 seconds for 90% of final value, using 500 ppm of isobutylene |
| Fréquence | 50/60 Hz |
| Type de batterie | Lithium-ion |
| Interface série | USB |
| Profondeur (impériale) | 4 in. |
| Tension | 120 V |
| Largeur (impériale) | 9 in. |
| Reproductibilité | FID: ±2% at 500 ppm of methane; PID: ±1% at 100 ppm of isobutylene |
| Points de données | Auto mode - 1 per second to 1 per 999 minutes, user selectable; VOC or FE Mode - 2 to 30 seconds, user selectable |
| Composants mesurés | Most Organic and Inorganic Compounds |
| Débit | 1 L/min., nominal at sample probe inlet |
| Contraintes informatiques | USB port, Windows XP operating system or higher |
| Limites de détection | FID: 0.5 ppm of methane; PID: 0.5 ppm of isobutylene |
| Concentration | FID: 0 to 30,000 ppm (methane); PID: 0 to 2000 ppm (isobutylene) |
| Largeur (métrique) | 22.9 cm |
| Hauteur (métrique) | 29.2 cm |
| Combustible | 99.99% H2 for FID |
| Autonomie en mode portable | Minimum 10 hours |
| Plage de températures (métrique) | -10°C to 45°C |
| Autonomie de la batterie | 10 hours at 0°C |
| Plage de températures (impériale) | 14°F to 113°F |
| Type de détecteur | Dual Configured with FID and PID |
| Profondeur (métrique) | 10.2 cm |
Thermo Scientific™ TVA2020 Toxic Vapor Analyzer - FID Only with Sampling Probe
Quickly detect organic and inorganic compounds in demanding applications such as Method 21 monitoring and site remediation.
| Hauteur (impériale) | 11.5 in. |
|---|---|
| Certifications/Conformité | USA: Class I, Division 1, Groups A,B,C,D T3; Canada: Class I, Zone 1, Ex db ib IIC T3 Gb; ATEX: CE0359 Ex II 2 G Ex db ib IIC T3 Gb; IECEx: Ex db ib IIC T3 Gb |
| Précision | ±10% of reading or ±1.0 ppm, whichever is greater, from 1.0 to 10,000 ppm |
| Garantie | One year from date of shipment |
| Temps de réponse | Less than 3.5 seconds for 90% of final value, using 10,000 ppm of methane |
| Fréquence | 50/60 Hz |
| Type de batterie | Lithium-ion |
| Interface série | USB |
| Profondeur (impériale) | 4 in. |
| Tension | 120 V |
| Largeur (impériale) | 9 in. |
| Reproductibilité | ±2% at 500 ppm of methane |
| Points de données | Auto mode - 1 per second to 1 per 999 minutes, user selectable; VOC or FE Mode - 2 to 30 seconds, user selectable |
| Composants mesurés | Most Organic and Inorganic Compounds |
| Débit | 1 L/min., nominal at sample probe inlet |
| Contraintes informatiques | USB port, Windows XP operating system or higher |
| Limites de détection | 0.5 ppm of methane |
| Concentration | 0 to 30,000 ppm (methane) |
| Largeur (métrique) | 22.9 cm |
| Hauteur (métrique) | 29.2 cm |
| Combustible | 99.99% H2 for FID |
| Autonomie en mode portable | Minimum 10 hours |
| Plage de températures (métrique) | -10°C to 45°C |
| Autonomie de la batterie | 10 hours at 0°C |
| Plage de températures (impériale) | 14°F to 113°F |
| Type de détecteur | Flame Ionization Detector (FID) |
| Profondeur (métrique) | 10.2 cm |
Thermo Scientific™ TVA2020 Toxic Vapor Analyzer - Dual FID/PID with Enhanced Probe
Quickly detect organic and inorganic compounds in demanding applications such as Method 21 monitoring and site remediation.
| Hauteur (impériale) | 11.5 in. |
|---|---|
| Certifications/Conformité | USA: Class I, Division 1, Groups A,B,C,D T3; Canada: Class I, Zone 1, Ex db ib IIC T3 Gb; ATEX: CE0359 Ex II 2 G Ex db ib IIC T3 Gb; IECEx: Ex db ib IIC T3 Gb |
| Précision | FID Instrument - ±10% of reading or ±1.0 ppm, whichever is greater, from 1.0 to 10,000 ppm; PID Instrument - ±20 % of reading or ±0.5 ppm, whichever is greater, from 0.5 to 500 ppm |
| Garantie | One year from date of shipment |
| Temps de réponse | FID: Less than 3.5 seconds for 90% of final value, using 10,000 ppm of methane; PID: Less than 3.5 seconds for 90% of final value, using 500 ppm of isobutylene |
| Fréquence | 50/60 Hz |
| Type de batterie | Lithium-ion |
| Interface série | USB |
| Profondeur (impériale) | 4 in. |
| Tension | 120 V |
| Largeur (impériale) | 9 in. |
| Reproductibilité | FID: ±2% at 500 ppm of methane; PID: ±1% at 100 ppm of isobutylene |
| Points de données | Auto mode - 1 per second to 1 per 999 minutes, user selectable; VOC or FE Mode - 2 to 30 seconds, user selectable |
| Composants mesurés | Most Organic and Inorganic Compounds |
| Débit | 1 L/min., nominal at sample probe inlet |
| Contraintes informatiques | USB port, Windows XP operating system or higher |
| Limites de détection | FID: 0.5 ppm of methane; PID: 0.5 ppm of isobutylene |
| Concentration | FID: 0 to 30,000 ppm (methane); PID: 0 to 2000 ppm (isobutylene) |
| Largeur (métrique) | 22.9 cm |
| Hauteur (métrique) | 29.2 cm |
| Combustible | 99.99% H2 for FID |
| Autonomie en mode portable | Minimum 10 hours |
| Plage de températures (métrique) | -10°C to 45°C |
| Autonomie de la batterie | 10 hours at 0°C |
| Plage de températures (impériale) | 14°F to 113°F |
| Type de détecteur | Dual Configured with FID and PID |
| Profondeur (métrique) | 10.2 cm |
Thermo Scientific™ TVA2020 Toxic Vapor Analyzer - FID Only with Enhanced Probe
Quickly detect organic and inorganic compounds in demanding applications such as Method 21 monitoring and site remediation.
| Hauteur (impériale) | 11.5 in. |
|---|---|
| Certifications/Conformité | USA: Class I, Division 1, Groups A,B,C,D T3; Canada: Class I, Zone 1, Ex db ib IIC T3 Gb; ATEX: CE0359 Ex II 2 G Ex db ib IIC T3 Gb; IECEx: Ex db ib IIC T3 Gb |
| Précision | ±10% of reading or ±1.0 ppm, whichever is greater, from 1.0 to 10,000 ppm |
| Garantie | One year from date of shipment |
| Temps de réponse | Less than 3.5 seconds for 90% of final value, using 10,000 ppm of methane |
| Fréquence | 50/60 Hz |
| Type de batterie | Lithium-ion |
| Interface série | USB |
| Profondeur (impériale) | 4 in. |
| Tension | 120 V |
| Largeur (impériale) | 9 in. |
| Reproductibilité | ±2% at 500 ppm of methane |
| Points de données | Auto mode - 1 per second to 1 per 999 minutes, user selectable; VOC or FE Mode - 2 to 30 seconds, user selectable |
| Composants mesurés | Most Organic and Inorganic Compounds |
| Débit | 1 L/min., nominal at sample probe inlet |
| Contraintes informatiques | USB port, Windows XP operating system or higher |
| Limites de détection | 0.5 ppm of methane |
| Concentration | 0 to 30,000 ppm (methane) |
| Largeur (métrique) | 22.9 cm |
| Hauteur (métrique) | 29.2 cm |
| Combustible | 99.99% H2 for FID |
| Autonomie en mode portable | Minimum 10 hours |
| Plage de températures (métrique) | -10°C to 45°C |
| Autonomie de la batterie | 10 hours at 0°C |
| Plage de températures (impériale) | 14°F to 113°F |
| Type de détecteur | Flame Ionization Detector (FID) |
| Profondeur (métrique) | 10.2 cm |
Thermo Scientific™ TVA2020 Toxic Vapor Analyzer - FID Only (No Probes)
Quickly detect organic and inorganic compounds in demanding applications such as Method 21 monitoring and site remediation.
| Hauteur (impériale) | 11.5 in. |
|---|---|
| Certifications/Conformité | USA: Class I, Division 1, Groups A,B,C,D T3; Canada: Class I, Zone 1, Ex db ib IIC T3 Gb; ATEX: CE0359 Ex II 2 G Ex db ib IIC T3 Gb; IECEx: Ex db ib IIC T3 Gb |
| Précision | ±10% of reading or ±1.0 ppm, whichever is greater, from 1.0 to 10,000 ppm |
| Garantie | One year from date of shipment |
| Temps de réponse | Less than 3.5 seconds for 90% of final value, using 10,000 ppm of methane |
| Fréquence | 50/60 Hz |
| Type de batterie | Lithium-ion |
| Interface série | USB |
| Profondeur (impériale) | 4 in. |
| Tension | 120 V |
| Largeur (impériale) | 9 in. |
| Reproductibilité | ±2% at 500 ppm of methane |
| Points de données | Auto mode - 1 per second to 1 per 999 minutes, user selectable; VOC or FE Mode - 2 to 30 seconds, user selectable |
| Composants mesurés | Most Organic and Inorganic Compounds |
| Débit | 1 L/min., nominal at sample probe inlet |
| Contraintes informatiques | USB port, Windows XP operating system or higher |
| Limites de détection | 0.5 ppm of methane |
| Concentration | 0 to 30,000 ppm (methane) |
| Largeur (métrique) | 22.9 cm |
| Hauteur (métrique) | 29.2 cm |
| Combustible | 99.99% H2 for FID |
| Autonomie en mode portable | Minimum 10 hours |
| Plage de températures (métrique) | -10°C to 45°C |
| Autonomie de la batterie | 10 hours at 0°C |
| Plage de températures (impériale) | 14°F to 113°F |
| Type de détecteur | Flame Ionization Detector (FID) |
| Profondeur (métrique) | 10.2 cm |
Thermo Scientific™ TVA2020 Toxic Vapor Analyzer - FID Only with Enhanced & Sampling Probes
Quickly detect organic and inorganic compounds in demanding applications such as Method 21 monitoring and site remediation.
| Hauteur (impériale) | 11.5 in. |
|---|---|
| Certifications/Conformité | USA: Class I, Division 1, Groups A,B,C,D T3; Canada: Class I, Zone 1, Ex db ib IIC T3 Gb; ATEX: CE0359 Ex II 2 G Ex db ib IIC T3 Gb; IECEx: Ex db ib IIC T3 Gb |
| Précision | ±10% of reading or ±1.0 ppm, whichever is greater, from 1.0 to 10,000 ppm |
| Garantie | One year from date of shipment |
| Temps de réponse | Less than 3.5 seconds for 90% of final value, using 10,000 ppm of methane |
| Fréquence | 50/60 Hz |
| Type de batterie | Lithium-ion |
| Interface série | USB |
| Profondeur (impériale) | 4 in. |
| Tension | 120 V |
| Largeur (impériale) | 9 in. |
| Reproductibilité | ±2% at 500 ppm of methane |
| Points de données | Auto mode - 1 per second to 1 per 999 minutes, user selectable; VOC or FE Mode - 2 to 30 seconds, user selectable |
| Composants mesurés | Most Organic and Inorganic Compounds |
| Débit | 1 L/min., nominal at sample probe inlet |
| Contraintes informatiques | USB port, Windows XP operating system or higher |
| Limites de détection | 0.5 ppm of methane |
| Concentration | 0 to 30,000 ppm (methane) |
| Largeur (métrique) | 22.9 cm |
| Hauteur (métrique) | 29.2 cm |
| Combustible | 99.99% H2 for FID |
| Autonomie en mode portable | Minimum 10 hours |
| Plage de températures (métrique) | -10°C to 45°C |
| Autonomie de la batterie | 10 hours at 0°C |
| Plage de températures (impériale) | 14°F to 113°F |
| Type de détecteur | Flame Ionization Detector (FID) |
| Profondeur (métrique) | 10.2 cm |
Thermo Scientific™ Nalgene™ Acrylic Beta Waste Shields
Produit Greener Choice
Ce produit offre un ou plusieurs avantages environnementaux détaillés dans les Guides Verts du FTC aux États-Unis.
Découvrez le programme Greener Choice
Ce produit offre un ou plusieurs avantages environnementaux détaillés dans les Guides Verts du FTC aux États-Unis.
Découvrez le programme Greener Choice
Completely enclose a large container holding solid or liquid radioactive waste with these acrylic beta waste shields, which are collapsible for convenient storage.
| Matériau | Acrylic |
|---|---|
| Épaisseur (impériale) | 0.37 in. |
| Épaisseur (métrique) | 9 mm |
Thermo Scientific™ Nalgene™ Acrylic Benchtop Beta Radiation Shield
Produit Greener Choice
Ce produit offre un ou plusieurs avantages environnementaux détaillés dans les Guides Verts du FTC aux États-Unis.
Découvrez le programme Greener Choice
Ce produit offre un ou plusieurs avantages environnementaux détaillés dans les Guides Verts du FTC aux États-Unis.
Découvrez le programme Greener Choice
Protect lab workers with these benchtop radiation shields, specifically designed for use during procedures which require the handling of beta-emitting isotopes.
| Certifications/Conformité | Both shields meet OSHA Standard 29CFR Part 1910.1030 for use as protection against bloodborne pathogens. |
|---|---|
| Description | Angled-top, Beta Radiation Shield |
| Profondeur (impériale) intérieure | 12 in. |
| Matériau | Acrylic |
| Épaisseur (impériale) | 0.37 in. |
| Profondeur (métrique) intérieure | 30 cm |
| Épaisseur (métrique) | 9 mm |