Filtering Microplates
- (7)
- (71)
- (50)
- (21)
- (2)
- (5)
- (5)
- (78)
- (3)
- (8)
- (18)
- (1)
- (7)
- (2)
- (5)
- (34)
- (7)
- (71)
Filtered Search Results
MilliporeSigma™ MultiScreen™ Solvinert Filter Plates
Optimized for drug discovery applications. MultiScreen™ Solvinert Filter Plates are solvent compatible and feature a unique one-piece design. 96-well plates are available in deep well (2mL) format (with or without pre-filter) and standard (500μL) format, with hydrophobic or hydrophilic membranes.
| Pore Size | 0.45 μm |
|---|---|
| Array | 8 x 12 |
| No. of Wells | 96 |
| Format | Standard |
| Length (Metric) | 1.28 cm |
| Color | Clear |
| Material | Polyolefin Copolymer |
| For Use With (Application) | Solid phase synthesis and cleanup, in plate protein precipitation, sample recovery following in-plate compound cleavage, peptide synthesis |
| Width (Metric) | 8.55 cm |
| Sterility | Non-sterile |
MilliporeSigma™ MultiScreen™ 96-Well Assay Plates
Provide tools to perform high-throughput studies of ADME processes—the investigation of the adsorption, distribution, metabolism, and excretion of potential drugs
| Array | 8 x 12 |
|---|---|
| No. of Wells | 96 |
| Format | Standard |
| Sterility | Non-sterile |
MilliporeSigma™ MultiScreen™ High Volume Filter Plates
Multiwell solutions for discovery research and sample prep
| Array | 8 x 12 |
|---|---|
| Height (Metric) | 4.7 cm |
| Dimensions (L x W x H) | 0.5 x 3.37 x 1.85 in. (1.27 x 8.56 x 4.7 cm) |
| No. of Wells | 96 |
| Format | Standard |
| Length (Metric) | 1.27 cm |
| Color | Opaque |
| Material | Polypropylene |
| Volume (Metric) Well | 2 mL |
| Width (Metric) | 8.56 cm |
| Sterility | Non-sterile |
MilliporeSigma™ MultiScreen™-Mesh Filter Plates with 96-Well Receiver Plates
Ideal for target screening and other applications that evaluate new compounds using multicellular organisms as the in vivo model
| Array | 8 x 12 |
|---|---|
| No. of Wells | 96 |
| Format | Standard |
| Color | Clear |
| Quantity | 10/Pk. |
| Membrane | Nylon Mesh |
| Material | Styrene |
| For Use With (Application) | Whole organism screening |
| Sterility | Non-sterile |
MilliporeSigma™ MultiScreen™ Solvinert Filter Plates
Optimized for drug discovery applications. MultiScreen™ Solvinert Filter Plates are solvent compatible and feature a unique one-piece design. 96-well plates are available in deep well (2mL) format (with or without pre-filter) and stand
MilliporeSigma™ MultiScreenHTS Solubility Filter Plate
96-well filter plate designed and optimized for aqueous solubility assays
| Pore Size | 0.4 μm |
|---|---|
| Array | 8 x 12 |
| No. of Wells | 96 |
| Format | Standard |
| Color | Clear |
| Membrane | Polycarbonate |
| Material | Styrene |
| For Use With (Application) | Aqueous solubility assays |
| Sterility | Non-sterile |
MilliporeSigma™ MultiScreenHTS 384-Well Filter Plates
Use in automated, high throughput applications, including biological assays and sample preparation. MultiScreenHTS 384-Well Filter Plates are non-sterile, single use plates available in several mesh materials and pore sizes to meet the needs of different applications.
| Array | 16 x 24 |
|---|---|
| Height (Metric) | 1.44 cm |
| Dimensions (L x W x H) | 1.28 x 8.55 x 1.44 cm |
| No. of Wells | 384 |
| Format | Standard |
| Length (Metric) | 1.28 cm |
| Color | Opaque,White Bottom |
| Membrane | Glass Fiber, Polyester Mesh |
| Material | Barex |
| Width (Metric) | 8.55 cm |
| Sterility | Non-sterile |
MilliporeSigma™ MultiScreen™ 96-Well Assay Plates for ELISPOT Assays
Give optimal results in immunological ELISPOT (enzyme-linked immunospot) assays by providing high protein-binding capacity with low background staining
| Pore Size | 0.45 μm |
|---|---|
| Array | 8 x 12 |
| No. of Wells | 96 |
| Format | Standard |
| For Use With (Application) | ELISPOT Assays |
| Filtration Area | 0.28 cm2 |
| Product Line | MultiScreen |
MilliporeSigma™ MultiScreen™ 96-Well Assay Plates for Sample Preparation
For the isolation, purification, and preparation of samples prior to testing in drug discovery processes and protein and DNA applications
| Array | 8 x 12 |
|---|---|
| No. of Wells | 96 |
| Format | Standard |
MilliporeSigma™ MultiScreen™ 96-Well Assay Plates for Cell-Based Assays
Offer formats that allow a wide range of functional cell-based and whole-organism assays to be performed
| Array | 8 x 12 |
|---|---|
| No. of Wells | 96 |
| Format | Standard |
| Color | Clear |
| Surface Treatment | Tissue Culture |
| Membrane | Polycarbonate |
| Material | Styrene |
| For Use With (Application) | Migration, invasion and chemotaxis |
| Sterility | Sterile |
MilliporeSigma™ MultiScreen™ HTS 96-Well Filter Plates with MCE Membrane
Commonly used for Elispot assays, bacterial screening, ELISA or viral infection studies
| Pore Size | 0.45 μm |
|---|---|
| Array | 8 x 12 |
| No. of Wells | 96 |
| Format | Standard |
| Membrane | Mixed Cellulose Esters |
| For Use With (Application) | Solid phase RIA, DNA hybridization, ELISA, protein binding |
MilliporeSigma™ MultiScreenHTS Durapore™ 96-Well Filter Plates
Designed for full automation compatibility. MultiScreenHTS Durapore™ 96-Well Filter Plates are innovative plates ideal for bead based assays. Opaque Barex™ and clear, sterile or non-sterile styrene and racks are available in a range of pore sizes.
| Array | 8 x 12 |
|---|---|
| No. of Wells | 96 |
| Format | Standard |
| Membrane | Hydrophilic PVDF |
| Certifications/Compliance | ANSI, SBS |
MilliporeSigma™ MultiScreen™HTS 96-Well Filter Plates for Clearing
Designed to meet specific performance criteria for sample preparation methodology
| Array | 8 x 12 |
|---|---|
| No. of Wells | 96 |
| Format | Standard |
| Color | Clear |
| Sterility | Non-sterile |
MilliporeSigma™ MultiScreenHTS 96-Well Filter Plates
Non-sterile, clear 96-well filter plate with 0.45μm pore size Hydrophobic PVDF membrane for protein interaction assays, Avidin-biotin Linkages, DNA-binding proteins.
MilliporeSigma™ MultiScreenHTS 96-Well Filter Plates
For filtration-based solubility determination. MultiScreenHTS 96-Well Filter Plates are specifically developed for use with automation