Fisherbrand™ accumet™ AP125 Portable pH/Ion/mV/Temperature Meter
Accurate measurements any time, anywhere
| Précision | Multiple |
|---|---|
| Type de produit | Meter Only |
| Garantie | 3 Years |
| Résolution (pH) | Adjustable |
| Measurement Modes | pH,Ion,mV,Temperature |
| Points d’étalonnage | 10 |
| Résolution | Multiple |
| Gamme (mV) | 0 to ±2000 mV |
| À utiliser avec (application) | pH, Ion concentration, mV, Temperature |
| Type d’affichage | LCD |
| Précision (mV) | 0 to ±2000mV |
| Plage de températures (métrique) | -5°C to +100°C |
| Indice IP | IP67 |
| Plage | -2 to +20pH |
| Comprend | Meter, 9V battery, manual |
| Gamme (pH) | 2 to 20 |
| Plage de températures (impériale) | 23°F to 212°F |
| Points de données | 200 |
Fisherbrand™ accumet™ AP125 Portable pH/Ion/mV/Temperature Meter Kit
Accurate measurements any time, anywhere
Fisherbrand™ Traceable™ pH/ORP/Temperature Meter
Measure critical water quality parameters — without the need to carry multiple units.
Fisherbrand™ accumet™ XL600 Benchtop Dual pH/ISE, Conductivity and Dissolved Oxygen Meters
Provide advanced measurements with simple operation and offer a large, vivid color touch-screen display. Fisherbrand accumet XL600 pH/ISE/conductivity/DO benchtop meters offer advanced features with simple operation to help ensure your measurements are reliable and your laboratory processes are efficient.
| Certifications/Conformité | NIST, ISO, FDA, USDA, EPA |
|---|---|
| Précision (résistivité) | ± 1% full scale |
| Longueur (impériale) | 9.68 in. |
| Détails de la gestion des données | 3 to 86400 sec. |
| Tension | 100/240 V |
| Précision de la température | ±0.2°C (±0.3°F) |
| Gamme de détection | Multiple |
| Points d’étalonnage (pH) | Up to 6 preset or 5 custom |
| Poids (métrique) | 1.13 kg |
| Gamme (OD) | 0 to 20mg/L (0 to 1272mbar), 0 to 200% saturation with 13-620-SSP electrode |
| Résolution (pH) | 0.1/0.01/0.001 |
| Entrées | 2 BNC, 2 ATC |
| Résolution (conductivité) | 0.001/0.01/0.1mS |
| Type d’affichage | LCD |
| Précision (DO) | 0.1 +1 LSD |
| Poids (impériale) | 2.5 lb. |
| Résolution (mV) | 0.1mV |
| Précision (TDS) | ± 1% full scale |
| Précision (salinité) | ± 1% full scale |
| Hauteur (impériale) | 3.89 in. |
| Précision | Multiple |
| Résolution de la température | 0.1°C |
| Résolution (ionométrie) | 2/3/4 Digits |
| Précision (pH) | ±0.002 |
| Dimensions (L x l x H) | 24.6 x 17.3 x 9.9cm (9.7 x 6.8 x 3.9 in.) |
| Garantie | 3 Years |
| Résolution (TDS) | 0.01/0.1ppm, 0.001/0.01/0.1ppt |
| Gamme (ions spécifiques) | ±2000 mV |
| Points d’étalonnage (conductivité) | Automatic (4 points), maximum 1/range, manual (5 points), maximum 1/range |
| Résolution (OD) | 0.01mg/L (0.1mbar), 0.1% saturation |
| Gamme (salinité) | 0 to 80 ppt |
| Fréquence | 50/60Hz |
| Sorties | RS232, USB-A, Mini-B USB, RJ45, stirrer port (2) |
| Gamme (résistivité) | 3 W to 100 MW over 4 ranges: 0 to 20 kW, 20 to 200 kW, 200 kW to 2 MW, 2 to 100 MW |
| Points de données | 2000 |
| Points d’étalonnage (ionométrie) | 2 to 6 |
| Précision (conductivité) | ±1% FS |
| Longueur (métrique) | 24.6 cm |
| Constante de cellule | 0.01 to 10 |
| Résolution (salinité) | 0.01/0.1ppm, 0.001/0.01/0.1ppt |
| Résolution (résistivité) | 0.01/0.1W, 0.001/0.1kW, 0.01MW |
| Gamme (TDS) | 0.050 ppm to 500 ppt (at TDS factor 1.00) |
| Résolution | Multiple |
| Gamme (mV) | ±2000 mV |
| Hauteur (métrique) | 9.9 cm |
| Largeur (métrique) | 17.3 cm |
| Précision (mV) | ±0.2 mV |
| Gamme (pH) | -2 to 20 |
| Gamme (conductivité) | 0 to 500 mS |
| Précision (ions spécifiques) | 0.5% full scale (monovalent ion), 1% full scale (divalent ion) |
Fisherbrand™ accumet™ XL200 Benchtop pH/Conductivity Meters
Provide advanced measurements with simple operation and offer a large, vivid color touch-screen display that allows for dynamic functionality. Fisherbrand accumet XL200 pH/Conductivity benchtop meters offer advanced features with simple operation to help ensure your measurements are reliable and your laboratory processes are efficient.
| Hauteur (impériale) | 3.89 in. |
|---|---|
| Certifications/Conformité | NIST, ISO, FDA, USDA, EPA |
| Précision (résistivité) | ± 1% full scale |
| Précision | Multiple |
| Résolution de la température | 0.1°C |
| Précision (pH) | ±0.002 |
| Dimensions (L x l x H) | 24.6 x 17.3 x 9.9cm (9.7 x 6.8 x 3.9 in.) |
| Garantie | 3 Years |
| Résolution (TDS) | 0.01/0.1ppm, 0.001/0.01/0.1ppt |
| Points d’étalonnage (conductivité) | Automatic (4 points), maximum 1/range, manual (5 points), maximum 1/range |
| Gamme (salinité) | 0 to 80 ppt |
| Fréquence | 50/60Hz |
| Longueur (impériale) | 9.68 in. |
| Sorties | RS232, USB-A, Mini-B USB, RJ45, stirrer port (2) |
| Détails de la gestion des données | 3 to 86400 sec. |
| Tension | 100/240 V |
| Précision de la température | ±0.2°C |
| Gamme (résistivité) | 3 W to 100 MW over 4 ranges: 0 to 20 kW, 20 to 200 kW, 200 kW to 2 MW, 2 to 100 MW |
| Gamme de détection | Multiple |
| Points de données | 2000 |
| Points d’étalonnage (pH) | Up to 6 preset or 5 custom |
| Poids (métrique) | 1.13 kg |
| Précision (conductivité) | ±1% FS |
| Longueur (métrique) | 24.6 cm |
| Constante de cellule | 0.01 to 10 |
| Résolution (salinité) | 0.01/0.1ppm, 0.001/0.01/0.1ppt |
| Résolution (résistivité) | 0.01/0.1W, 0.001/0.1kW, 0.01MW |
| Résolution (pH) | 0.1/0.01/0.001 |
| Gamme (TDS) | 0.050 ppm to 500 ppt (at TDS factor 1.00) |
| Résolution | Multiple |
| Entrées | BNC, ATC |
| Gamme (mV) | ±2000 mV |
| Résolution (conductivité) | 0.001/0.01/0.1mS |
| Type d’affichage | LCD |
| Hauteur (métrique) | 9.9 cm |
| Largeur (métrique) | 17.3 cm |
| Poids (impériale) | 2.5 lb. |
| Précision (mV) | ±0.2 mV |
| Résolution (mV) | 0.1mV |
| Gamme (pH) | -2 to 20 |
| Précision (TDS) | ± 1% full scale |
| Gamme (conductivité) | 0 to 500 mS |
| Précision (salinité) | ± 1% full scale |
Thermo Scientific™ Elite PCTS pH / Conductivity / TDS / Salinity Pocket Testers and Replacement Sensors
Flexible on-the-go pH, conductivity, TDS, salinity and temperature testing using durable Elite PCTS pocket testers for a variety of applications including agriculture, aquaculture, hydroponics and more!
| Compensation thermique | Yes |
|---|---|
| Résolution de la température | 0.1°C, 0.1°F |
| Étalonnage de la sonde de température | 1 point |
| Précision (pH) | ±0.02 |
| Résolution (salinité) | 0.10 ppt |
| Résolution (pH) | 0.01 |
| Gamme (TDS) | 0.00 to 10.00 ppt |
| Résolution (TDS) | 0.1 ppm for 0.0 to 100.0 ppm; 1 ppm for 100 to 1000 ppm; 0.01 ppt for 0.10 to 10.00 ppt |
| Measurement Modes | pH,Conductivity,TDS,Salinity,Temperature |
| Modes d’étalonnage | pH, conductivity, TDS, salinity, temperature |
| Points d’étalonnage (conductivité) | 1 to 3 |
| Modes de mesure de la salinité | Per practical salinity curve |
| Résolution (conductivité) | 0.1 μS/cm for 0.0 to 200.0 μS/cm; 1 μS/cm for200 to 2000 μS/cm; 0.01 mS/cm for 2.00 to 20.00 mS/cm |
| Gamme (salinité) | 0.00 to 10.00 ppt |
| Température (métrique) en fonctionnement | 5°C to 45°C (ambient) |
| Gamme de facteurs TDS | 0.40 to 1.00 (selectable) |
| Gamme d’humidité relative | 5 to 85 %, non-condensing |
| Gamme (pH) | -1.00 to 15.00 |
| Précision de la température | ±0.6°C, ±1.0°F for 0.0 to 50.0°C; ±1.1°C, ±1.9°F for 50.1 to 60.0°C |
| Précision (TDS) | ± 1% full scale |
| Plage de températures (impériale) | 32.0°F to 140.0°F |
| Gamme (conductivité) | 0.00 to 20.00 mS/cm |
| Précision (salinité) | ± 1% full scale |
| Points d’étalonnage (pH) | 1 to 3 |
| Précision (conductivité) | ± 1% full scale |
Thermo Scientific™ Elite CTS Conductivity / TDS / Salinity Cup-sensor Pocket Testers and Replacement Sensors
Flexible on-the-go conductivity, TDS, salinity and temperature testing using durable Elite CTS cup-sensor pocket testers for a variety of applications including agriculture, aquariums and more!
| Compensation thermique | Yes |
|---|---|
| Résolution de la température | 0.1°C, 0.1°F |
| Étalonnage de la sonde de température | 1 point |
| Résolution (salinité) | 0.10 ppt |
| Gamme (TDS) | 0.00 to 10.00 ppt |
| Résolution (TDS) | 0.1 ppm for 0.0 to 100.0 ppm; 1 ppm for 100 to 1000 ppm; 0.01 ppt for 0.10 to 10.00 ppt |
| Measurement Modes | Conductivity,TDS,Salinity,Temperature |
| Points d’étalonnage (conductivité) | 1 to 3 |
| Modes de mesure de la salinité | Per practical salinity curve |
| Résolution (conductivité) | 0.1 μS/cm for 0.0 to 200.0 μS/cm; 1 μS/cm for200 to 2000 μS/cm; 0.01 mS/cm for 2.00 to 20.00 mS/cm |
| Gamme (salinité) | 0.00 to 10.00 ppt |
| Température (métrique) en fonctionnement | 5°C to 45°C (ambient) |
| Gamme de facteurs TDS | 0.40 to 1.00 (selectable) |
| Gamme d’humidité relative | 5 to 85 %, non-condensing |
| Précision de la température | ±0.6°C, ±1.0°F for 0.0 to 50.0°C; ±1.1°C, ±1.9°F for 50.1 to 60.0°C |
| Précision (TDS) | ± 1% full scale |
| Plage de températures (impériale) | 32.0°F to 140.0°F |
| Gamme (conductivité) | 0.00 to 20.00 mS/cm |
| Précision (salinité) | ± 1% full scale |
| Précision (conductivité) | ± 1% full scale |
Thermo Scientific™ Orion Star™ A324 pH/ISE Portable Multiparameter Meter
Accurately monitor pH, ion concentration, mV, ORP and temperature with our pH/ISE portable meter for challenging field testing.
| Certifications/Conformité | CE, TUV 3-1, FCC Class A |
|---|---|
| Clavier | Comprehensive with menu-specific function keys and dual purpose scroll/shortcut keys |
| Measurement Modes | pH,mV,Relative mV,ORP,Ion Concentration (ISE) with Temperature |
| Langues | English, Spanish, French, Italian, German and Chinese; Portuguese and Korean available with software update |
| Modèle | Orion Star A324 pH/ISE/mV/RmV/ORP/Temperature Portable Meter |
| Option de rétro-éclairage | Yes (Selectable) |
| Température (impériale) en fonctionnement | 41°F to 113°F (ambient) |
| Fonctions d’ionométrie avancées | Segmented (point-to-point) slope, non-linear selectable auto-blank, low concentration range stabilit |
| Détails de la gestion des données | Transfer single, range or all data points to printer or computer |
| Précision de la température | ±0.1°C |
| Points d’étalonnage (pH) | 1 to 5 |
| Poids (métrique) | 0.5 kg |
| Sorties d’alarme | High/low limit alarm, calibration due alarm |
| Type de fonction d’enregistrement | Automatic data logging with Auto-Read and Timed measure modes; manual data logging with Continuous m |
| Résolution (pH) | 0.1/0.01/0.001 |
| Entrées | BNC (pH, ORP or ion selective electrode), pin-tip (reference electrode), 8 pin MiniDIN (ATC temperature probe) |
| Étalonnage | pH with calibration editing option, ion concentration (ISE) with calibration editing option, relativ |
| Type d’affichage | LCD Graphic, Backlit |
| Alimentation électrique | 4 AA batteries (included) or universal AC adapter (sold separately) |
| Gamme (mV relative) | ±2000.0 mV |
| Mémoire | Non-volatile memory preserves data log, calibration log and meter settings |
| Poids (impériale) | 1.2 lb. |
| Température (métrique) en fonctionnement | 5°C to 45°C (ambient) |
| Résolution (mV) | 0.1mV |
| Plage de températures (métrique) | -5.0°C to +105.0°C |
| Autonomie de la batterie | 800 hr. |
| Gamme d’humidité relative | 5 to 85 %, non-condensing |
| Sélection de la température | Manual or automatic with ATC temperature probe |
| Résolution de la température | 0.1°C, 0.1°F |
| Gamme (rH) | ±2000.0 mV |
| Résolution (ionométrie) | 0.0001 minimum, 1 to 3 significant digits (user selectable) |
| Précision (pH) | ±0.002 |
| Dimensions (L x l x H) | 24cm x 10cm x 6.5cm (9.5 in. x 3.9 in. x 2.6 in.) |
| Garantie | 3 Year Meter |
| Gamme (ions spécifiques) | 0.0001 to 19900 with selectable units of ppm, Molar, mg/L, %, ppb or none |
| Adaptateur secteur | Universal 50-60 Hz, 100-240 VAC power adapter (sold separately, Cat. No. 1010003) |
| Point isopotentiel | 7.000pH |
| Canaux | 1 |
| Type de batterie | 4 AA (included) |
| Sorties | USB, RS232 |
| Stabilité | Selectable fast, medium, slow or Smart Stability setting; Selectable off or Automatic Smart averaging setting |
| Méthodes | 10 per channel with password protection |
| Indice IP | IP67 |
| Points de données | 5000 with Date and Time Stamp |
| Points d’étalonnage (ionométrie) | 1 to 5 |
| Étalonnage de la sonde de température | 1 point temperature offset calibration |
| Points d’étalonnage | 1 point relative mV (RmV) mode, 1 point ORP mode |
| Gamme (mV) | ±2000.0 mV |
| Précision (mV) | ±0.2 mV or ±0.05% of reading whichever is greater |
| Gamme (pH) | -2 to 20 |
| Plage de températures (impériale) | 22.0°F to 221.0° F |
| Précision (ions spécifiques) | ±0.2 mV or ±0.05% of reading whichever is greater |
Thermo Scientific™ Orion Star™ A326 pH/Dissolved Oxygen Portable Multiparameter Meter
Accurately measure pH, dissolved oxygen and temperature with our pH/DO/RDO portable meter for high performance in challenging field tests.
| Certifications/Conformité | CE, TUV 3-1, FCC Class A |
|---|---|
| Clavier | Comprehensive with menu-specific function keys and dual purpose scroll/shortcut keys |
| Measurement Modes | pH,mV,Relative mV,ORP with Temperature,Dissolved Oxygen (% Saturation),Dissolved Oxygen (mg/L with Temperature) |
| Langues | English, Spanish, French, Italian, German and Chinese; Portuguese and Korean available with software update |
| Modèle | Orion Star A326 pH/mV/RmV/ORP/RDO Optical/Dissolved Oxygen/Temperature Portable Meter |
| Option de rétro-éclairage | Yes (Selectable) |
| Température (impériale) en fonctionnement | 41°F to 113°F (ambient) |
| Détails de la gestion des données | Transfer single, range or all data points to printer or computer |
| Précision de la température | ±0.1°C |
| Points d’étalonnage (pH) | 1 to 5 |
| Poids (métrique) | 0.5 kg |
| Sorties d’alarme | High/low limit alarm, calibration due alarm |
| Résolution de la pression | 1mmHg |
| Type de fonction d’enregistrement | Automatic data logging with Auto-Read and Timed measure modes; manual data logging with Continuous m |
| Résolution (pH) | 0.1/0.01/0.001 |
| Percent Saturation Range Polarographic DO | 0.0 to 600.0 % saturation |
| Entrées | BNC (pH or ORP electrode), pin-tip (reference electrode), 8 pin MiniDIN (ATC temperature probe), 9 pin MiniDIN (RDO optical or polarographic DO sensor with built-in temperature) |
| Étalonnage | pH with calibration editing option, relative mV (RmV), ORP, dissolved oxygen and temperature |
| Type d’affichage | LCD Graphic, Backlit |
| Gamme (RDO) | 0.00 to 50.00mg/L |
| Alimentation électrique | 4 AA batteries (included) or universal AC adapter (sold separately) |
| Gamme (mV relative) | ±2000.0 mV |
| Mémoire | Non-volatile memory preserves data log, calibration log and meter settings |
| Poids (impériale) | 1.2 lb. |
| Température (métrique) en fonctionnement | 5°C to 45°C (ambient) |
| Précision (baromètre) | ±6mmHg |
| Résolution (mV) | 0.1mV |
| Plage de températures (métrique) | -5.0°C to +105.0°C |
| Autonomie de la batterie | 800 hr. |
| Gamme d’humidité relative | 5 to 85 %, non-condensing |
| Facteur de salinité | 0.0 to 45.0 ppt, automatic correction using manual entry of sample salinity |
| Plage de saturation en pourcentage (RDO) | 0.0 to 500.0 % saturation |
| Percent Saturation Relative Accuracy (RDO) | ±2 % saturation ≤ 200 % saturation, ±10 % saturation > 200 % saturation |
| Sélection de la température | Manual or automatic with ATC temperature probe |
| Résolution de la température | 0.1°C, 0.1°F |
| Gamme (rH) | ±2000.0 mV |
| Résolution du coefficient de saturation (RDO) | 0.1, 1 % saturation |
| Correction de la pression barométrique | 400 to 850mmHg, automatic using built-in barometer or manual entry |
| Précision (pH) | ±0.002 |
| Dimensions (L x l x H) | 24cm x 10cm x 6.5cm (9.5 in. x 3.9 in. x 2.6 in.) |
| Garantie | 3 Year Meter |
| Précision (OD par mesure polarographique) | ±0.2mg/L or ±2% of reading, whichever is greater |
| Adaptateur secteur | Universal 50-60 Hz, 100-240 VAC power adapter (sold separately, Cat. No. 1010003) |
| Point isopotentiel | 7.000pH |
| Canaux | 2 |
| Type de batterie | 4 AA (included) |
| Sorties | USB, RS232 |
| Stabilité | Selectable fast, medium, slow or Smart Stability setting; Selectable off or Automatic Smart averaging setting |
| Méthodes | 10 per channel with password protection |
| Gamme (OD par mesure polarographique) | 0.00 to 90.00mg/L |
| Indice IP | IP67 |
| Percent Saturation Relative Accuracy (Polarographic DO) | ±2 % saturation or ±2% of reading whichever is greater |
| Points de données | 5000 with Date and Time Stamp |
| Gamme de pression | 400 to 850mmHg |
| Étalonnage de la sonde de température | 1 point temperature offset calibration |
| Résolution (OD par mesure polarographique) | 0.01, 0.1mg/L |
| Points d’étalonnage | 1 point relative mV (RmV) mode, 1 point ORP mode |
| Modes d’étalonnage | Water-saturated air, air-saturated water, manual (Winkler titration), zero point |
| Gamme (mV) | ±2000.0 mV |
| Percent Saturation Resolution (Polarographic DO) | 0.1, 1 % saturation |
| Précision (mV) | ±0.2 mV or ±0.05% of reading whichever is greater |
| Résolution (RDO) | 0.01, 0.1mg/L |
| Gamme (pH) | -2 to 20 |
| Plage de températures (impériale) | 22.0°F to 221.0° F |
| Précision (RDO) | ±0.1mg/L up to 8mg/L, ±0.2mg/L from 8 to 20mg/L, ±10% of reading up to 50mg/L |
| Percent Saturation Range (Polarographic DO) | 0.0 to 600.0 % saturation |
Thermo Scientific™ Orion™ Pro Star PC215 pH/ion and Conductivity Bench Meter with Stand
Designed to provide accurate and reliable pH, ORP, ion concentration, conductivity, TDS, salinity, resistivity and temperature analysis, the Thermo Scientific™ Orion™ Pro Star PC215 bench meter is well suited for laboratories that desire a modern meter with advance performance.
| Certifications/Conformité | CE, TUV 3-1, FCC Class A |
|---|---|
| Clavier | Capacitive touchscreen user interface |
| Précision (résistivité) | ±0.5% reading |
| Langues | Chinese, English, French, German, Italian, Japanese, Korean, Portuguese, Spanish |
| Option de rétro-éclairage | Yes |
| Fonctions d’ionométrie avancées | Single known addition, single known subtraction, double known addition, double known subtraction, analyte addition and analyte subtraction |
| Précision de la température | ±0.3°C, ±0.5°F |
| Points d’étalonnage (pH) | 1 to 5 points |
| Poids (métrique) | 1.00 kg |
| Sorties d’alarme | Calibration reminder alarm, high and low limit alarm per parameter |
| Type de fonction d’enregistrement | Automatic with Auto-Read and Timed Read Modes, Manual with Continuous Read Mode |
| Résolution (pH) | 0.1, 0.01 or 0.001 pH |
| Résolution (rH) | 0.1 mV |
| Entrées | Channel 1: BNC for pH, ORP or ISE, 8-pin MiniDIN for ATC, pin-tip for reference; Channel 2: 8-pin MiniDIN for conductivity with ATC |
| Étalonnage | pH, ORP, Ion Concentration, Conductivity, TDS, Salinity, Temperature |
| Température (métrique) de référence | 5, 10, 15, 20, 25 or 30°C |
| Résolution (conductivité) | 0.001 μS/cm minimum, auto-ranging, up to 4 digits |
| Type d’affichage | 7-in. High-resolution Color Graphic LCD |
| Gamme (mV relative) | -2000 to 2000 mV |
| Mémoire | Non-volatile |
| Poids (impériale) | 2.20 lbs. |
| Résolution (mV) | 0.1 mV |
| Plage de températures (métrique) | -30.0°C to +130.0°C |
| Précision (TDS) | ±0.5% reading |
| Précision (salinité) | ±0.5% reading |
| Sélection de la température | Automatic with ATC temperature sensor, ambient or manual |
| Compensation thermique | Linear (0.00 to 10.00 %/°C), nLFn (non-linear natural water), nLFu (non-linear ultra-pure water), EP/USP or off |
| Résolution de la température | 0.1°C, 0.1°F |
| Gamme (rH) | -2000 to 2000 mV |
| Résolution (ionométrie) | 0.0001 minimum, 1 to 5 digits |
| Résolution (ion) | 0.0001 minimum, 1 to 5 digits |
| Précision (pH) | ±0.002 pH |
| Dimensions (L x l x H) | 218.9 x 153.2 x 91.33 mm; 8.62 x 6.03 x 3.60 in. |
| Garantie | 2 year meter warranty |
| Précision (rH) | ±0.2 mV or ±0.05% of the reading, whichever is greater |
| Résolution (TDS) | 0.001 ppm or mg/L minimum, auto-ranging, up to 4 digits |
| Gamme (ions spécifiques) | 0.0001 to 19999 |
| Adaptateur secteur | Universal 100-240 V 50/60 Hz power supply with wall plugs for US/Japan, Euro, UK/Singapore, Australia/New Zealand and China outlets |
| Point isopotentiel | 7.000 pH; 1.000 ion concentration |
| Canaux | 2 |
| Points d’étalonnage (conductivité) | 1 to 5 points |
| Modes de mesure de la salinité | Natural Seawater (ppt), Practical Salinity Units (PSU), or % NaCl |
| Gamme (salinité) | 0.010 to 80.00 ppt; 0.01 to 42.00 PSU; or 0.01 to 400.0% NaCl |
| Sorties | USB flash drive, computer or printer (STARA-106) |
| Méthodes | 10 per channel (20 total) |
| Gamme de facteurs TDS | Linear (0.01 to 10.00), ISO/EN 27888, 442, NaCl |
| Indice IP | IP54 |
| Gamme (résistivité) | 1.0 Ω to 100.0 MΩ |
| Points de données | 10,000 with Date and Time Stamp |
| Points d’étalonnage (ionométrie) | Up to 5 |
| Précision (conductivité) | ±0.5% reading |
| Étalonnage de la sonde de température | 1 or 2 point temperature offset calibration |
| Constante de cellule | 0.100 cm-1, 0.475 cm-1, 0.550 cm-1, 1.000 cm-1, 10.00 cm-1 or user-defined from 0.001 to 199.9 cm-1 |
| Résolution (salinité) | 0.001 ppt minimum; 0.01 PSU minimum; or 0.01% NaCl minimum, auto-ranging |
| Résolution (résistivité) | 0.1 Ω minimum, auto-ranging |
| Gamme (TDS) | 0.010 ppm to 500.0 ppt (TDS factor of 1.00); or 0.010 mg/L to 500.0 g/L (TDS factor of 1.00) |
| Points d’étalonnage | 1 to 5 (pH), 1 (ORP), 1 to 5 (ion), 1 to 5 (conductivity), 1 to 5 (TDS), 1 (salinity), 1 to 2 (temperature) |
| Gamme (ion) | 0.0001 to 19999 |
| Gamme (mV) | -2000 to 2000 mV |
| Précision (mV) | ±0.2 mV or ±0.05% of the reading, whichever is greater |
| Gamme (pH) | -2 to 20 |
| Plage de températures (impériale) | -22.0°F to +266.0°F |
| Gamme (conductivité) | 0.010 μS/cm to 3000 mS/cm |
| Précision (ions spécifiques) | ±0.2 mV or ±0.05% of the reading, whichever is greater |
Fisherbrand™ accumet™ AR425 pH/ion Meter with Stand
Designed to deliver precise and reliable electrochemistry testing, the accumet AR425 offers enhanced performance in a streamlined design. Ideal for laboratories requiring dependable measurement capabilities.
Thermo Scientific™ Expert CTS Pocket Tester
Ensure accurate measurements of Conductivity, TDS, Salinity, and Temperature using the easy-to-use, large 4-digit display pocket tester for many applications.
Ohaus™ Starter ST20M-B Multi-Parameter Pen Meter
Compact design for fast, convenient electrochemistry readings. Measure conductivity, pH, temperature and TDS with the same meter. IP67, automatic temperature compensation, 3-point calibration and auto-off after 6 minutes of non-use.
Ohaus™ Starter ST20M-C Multi-Parameter Pen Meter
Compact design for fast, convenient electrochemistry reading. Measure conductivity, pH, temperature and salinity with the same meter. IP67, automatic temperature compensation, 3-point calibration and auto-off after 6 minutes of non-use
METTLER TOLEDO™ S600 SevenExcellence™ Dissolved Oxygen Benchtop Meter Kit
The S600 meter kit includes a meter, electrode, and accessories to measure disolved oxygen (DO). The meter can be expanded with additional modules to measure pH, conductivity, and ISE. It has an intuitive touchscreen, measurement shortcuts, and can export data to a printer, Excel, or LIMS system.