Multiparameter Meters
- (2)
- (16)
- (1)
- (4)
- (2)
- (4)
- (15)
- (12)
- (6)
- (1)
- (2)
- (33)
- (16)
- (4)
- (1)
- (2)
- (15)
- (1)
- (4)
- (11)
- (1)
- (13)
- (2)
- (8)
- (5)
- (23)
- (3)
- (1)
- (1)
- (7)
- (1)
- (8)
- (3)
- (2)
- (7)
- (40)
- (64)
- (2)
- (2)
- (8)
- (2)
- (35)
- (2)
- (19)
- (6)
- (2)
- (8)
- (13)
- (11)
- (11)
- (29)
- (13)
- (24)
- (2)
- (6)
- (21)
- (24)
- (30)
- (41)
- (77)
- (1)
- (4)
- (2)
- (3)
- (9)
- (57)
- (8)
- (21)
- (1)
Filtered Search Results
Fisherbrand™ accumet™ XL600 Benchtop Dual pH/ISE, Conductivity and Dissolved Oxygen Meters
Provide advanced measurements with simple operation and offer a large, vivid color touch-screen display. Fisherbrand accumet XL600 pH/ISE/conductivity/DO benchtop meters offer advanced features with simple operation to help ensure your measurements are reliable and your laboratory processes are efficient.
| Length (Metric) | 24.6 cm |
|---|---|
| Range (Resistivity) | 3 W to 100 MW over 4 ranges: 0 to 20 kW, 20 to 200 kW, 200 kW to 2 MW, 2 to 100 MW |
| Detection Range | Multiple |
| Length (English) | 9.68 in. |
| Cell Constant | 0.01 to 10 |
| Range (pH) | -2 to 20 |
| Width (Metric) | 17.3 cm |
| Accuracy (pH) | ±0.002 |
| Range (ISE) | ±2000 mV |
| Range (Salinity) | 0 to 80 ppt |
| Accuracy | Multiple |
| Data Management Details | 3 to 86400 sec. |
| Display Type | LCD |
| Accuracy (Salinity) | ± 1% full scale |
| Resolution (Salinity) | 0.01/0.1ppm, 0.001/0.01/0.1ppt |
| Voltage | 100/240 V |
| Accuracy (Conductivity) | ±1% FS |
| Resolution (mV) | 0.1mV |
| Resolution (DO) | 0.01mg/L (0.1mbar), 0.1% saturation |
| Data Points | 2000 |
| Certifications/Compliance | NIST, ISO, FDA, USDA, EPA |
| Inputs | 2 BNC, 2 ATC |
| Weight (Metric) | 1.13 kg |
| Height (English) | 3.89 in. |
| Calibration Points (Conductivity) | Automatic (4 points), maximum 1/range, manual (5 points), maximum 1/range |
| Height (Metric) | 9.9 cm |
| Accuracy (mV) | ±0.2 mV |
| Accuracy (ISE) | 0.5% full scale (monovalent ion), 1% full scale (divalent ion) |
| Warranty | 3 Years |
| Temperature Accuracy | ±0.2°C (±0.3°F) |
| Calibration Points (ISE) | 2 to 6 |
| Accuracy (DO) | 0.1 +1 LSD |
| Resolution (Resistivity) | 0.01/0.1W, 0.001/0.1kW, 0.01MW |
| Resolution (Conductivity) | 0.001/0.01/0.1mS |
| Range (Conductivity) | 0 to 500 mS |
| Accuracy (Resistivity) | ± 1% full scale |
| Range (TDS) | 0.050 ppm to 500 ppt (at TDS factor 1.00) |
| Resolution (TDS) | 0.01/0.1ppm, 0.001/0.01/0.1ppt |
| Dimensions (L x W x H) | 24.6 x 17.3 x 9.9cm (9.7 x 6.8 x 3.9 in.) |
| Accuracy (TDS) | ± 1% full scale |
| Outputs | RS232, USB-A, Mini-B USB, RJ45, stirrer port (2) |
| Frequency | 50/60Hz |
| Calibration Points (pH) | Up to 6 preset or 5 custom |
| Weight (English) | 2.5 lb. |
| Range (mV) | ±2000 mV |
| Range (DO) | 0 to 20mg/L (0 to 1272mbar), 0 to 200% saturation with 13-620-SSP electrode |
| Temperature Resolution | 0.1°C |
| Resolution | Multiple |
Fisherbrand™ Traceable™ pH/ORP/Temperature Meter
Measure critical water quality parameters — without the need to carry multiple units.
Fisherbrand™ accumet™ AP125 Portable pH/Ion/mV/Temperature Meter
Accurate measurements any time, anywhere
| Accuracy (mV) | 0 to ±2000mV |
|---|---|
| Warranty | 3 Years |
| Measurement Modes | pH,Ion,mV,Temperature |
| Range (pH) | 2 to 20 |
| Range | -2 to +20pH |
| For Use With (Application) | pH, Ion concentration, mV, Temperature |
| Includes | Meter, 9V battery, manual |
| Calibration Points | 10 |
| Accuracy | Multiple |
| Display Type | LCD |
| Product Type | Meter Only |
| IP Rating | IP67 |
| Temperature Range (English) | 23°F to 212°F |
| Data Points | 200 |
| Temperature Range (Metric) | -5°C to +100°C |
| Range (mV) | 0 to ±2000 mV |
| Resolution | Multiple |
Mettler Toledo™ pH/Ion Meter SevenDirect SD50
Greener Choice
Offers one or more environmental benefits itemized in the U.S. FTC Green Guides.
Learn More
Offers one or more environmental benefits itemized in the U.S. FTC Green Guides.
Learn More
The SevenDirect SD50 is an accurate and flexible benchtop meter for the determination of pH, ORP and ion concentrations. The instrument is the replacement of the SevenCompact and is delivered with an EasyPlace sensor arm.
| Temperature Accuracy | ±0.1°C between 0°C and 100°C |
|---|---|
| Memory | 2000 Standard Measurements |
| Measurement Modes | pH |
| Range (pH) | -2.000 to 20.000 |
| Accuracy (Ion) | 0.5 % |
| Accuracy (pH) | 0.002 |
| Dimensions (L x W x H) | 195 x 205 x 65 mm |
| Data Management Details | PC, Printer, USB Stick |
| Display Type | Color TFT |
| IP Rating | IP54 |
| Resolution (Ion) | 3 or 4 digits (auto-range) |
| Temperature Range (English) | -22°F to +266°F |
| Range (Ion) | -2,000 to 20,000 pX, 0 to 999,999 mg/L (ppm) |
| Temperature Range (Metric) | -30°C to +130°C |
| Range (mV) | -2000 to 2000 mV |
| Temperature Resolution | 0.1°C |
Thermo Scientific™ Elite CTS Conductivity / TDS / Salinity Pin-sensor Pocket Testers and Replacement Sensors
Flexible on-the-go conductivity, TDS, salinity and temperature testing using durable Elite CTS pin-sensor pocket testers for a variety of applications including hydroponics, pools, spas and more!
| Salinity Measurement Modes | Per practical salinity curve |
|---|---|
| Temperature Accuracy | ±0.6°C, ±1.0°F for 0.0 to 50.0°C; ±1.1°C, ±1.9°F for 50.1 to 60.0°C |
| Resolution (Conductivity) | 0.1 μS/cm for 0.0 to 200.0 μS/cm; 1 μS/cm for200 to 2000 μS/cm; 0.01 mS/cm for 2.00 to 20.00 mS/cm |
| Range (Conductivity) | 0.00 to 20.00 mS/cm |
| Range (TDS) | 0.00 to 10.00 ppt |
| Measurement Modes | Conductivity,TDS,Salinity,Temperature |
| Resolution (TDS) | 0.1 ppm for 0.0 to 100.0 ppm; 1 ppm for 100 to 1000 ppm; 0.01 ppt for 0.10 to 10.00 ppt |
| TDS Factor Range | 0.40 to 1.00 (selectable) |
| Relative Humidity Range | 5 to 85 %, non-condensing |
| Range (Salinity) | 0.00 to 10.00 ppt |
| Temperature Compensation | Yes |
| Accuracy (TDS) | ± 1% full scale |
| Accuracy (Salinity) | ± 1% full scale |
| Resolution (Salinity) | 0.10 ppt |
| Accuracy (Conductivity) | ± 1% full scale |
| Temperature Range (English) | 32.0°F to 140.0°F |
| Temperature Probe Calibration | 1 point |
| Temperature (Metric) Operating | 5°C to 45°C (ambient) |
| Temperature Resolution | 0.1°C, 0.1°F |
| Calibration Points (Conductivity) | 1 to 3 |
Thermo Scientific™ Orion™ Versa Star Pro™ pH/ISE Benchtop Multiparameter Meter
Get premium performance and ultimate flexibility with our benchtop meter with pH/ISE module for pH, ion concentration, and temperature.
| Power Rating | DC input: 9VDC, 1A |
|---|---|
| Memory | Non-volatile memory preserves data log, calibration log and meter settings |
| Advanced ISE Functions | Segmented (point-to-point) slope, non-linear selectable auto-blank, low concentration range stabilit |
| Languages | English, Spanish, French, Italian, German, Chinese, Portuguese and Korean |
| Measurement Modes | pH,mV,Relative mV,ORP,Ion Concentration (ISE) with Temperature |
| Range (pH) | -2 to 20 |
| Accuracy (pH) | ±0.002 |
| Range (ISE) | 0.0001 to 19990 with selectable units of ppm, Molar, mg/L, %, ppb or none |
| Power Supply | Universal AC adapter (included) |
| Data Management Details | Transfer single, range or all data points to printer or computer |
| Display Type | Color graphic LCD with user-customizable options |
| Resolution (mV) | 0.1mV |
| Data Points | 2000 with Date and Time Stamp |
| Temperature Probe Calibration | 1 point temperature offset calibration |
| Certifications/Compliance | CE, TUV 3-1, FCC Class A |
| Weight (Metric) | 1.2 kg, modules add 0.2 kg each |
| Accuracy (mV) | ±0.2 mV or ±0.05% of reading whichever is greater |
| Accuracy (ISE) | ±0.2 mV or ±0.05% of reading whichever is greater |
| Warranty | 3 year meter and module warranty |
| Temperature Accuracy | ±0.1°C |
| Stability | Selectable fast, medium, slow or Smart Stability setting; Selectable off or Automatic Smart averaging setting |
| Calibration Points (ISE) | 1 to 6 |
| Temperature (English) Operating | 41°F to 113°F (ambient) |
| Isopotential Point | 7.000pH (adjustable), 1.000 ISE (adjustable) |
| AC Adapter | Universal 50-60 Hz, 100-240 VAC power adapter (Cat. No. STARA-PWR) |
| Log Function Type | Automatic data logging with Auto-Read, Timed and Single Shot measure modes; manual data logging with |
| Calibration | pH with calibration editing option, ion concentration (ISE) with calibration editing option, relativ |
| Relative Humidity Range | 5 to 85 %, non-condensing |
| Calibration Points | 1 point relative mV (RmV) mode, 1 point ORP mode |
| Alarm Output | Set point alarm, high/low limit alarm, calibration due alarm |
| Dimensions (L x W x H) | 28cm x 24cm x 10cm (11 in. x 9.5 in. x 3.9 in.), modules add ≤ 2cm (0.8 in.) L & H |
| Temperature Selection | Manual or automatic with ATC temperature probe |
| IP Rating | IP54 |
| Keypad | Numeric with menu-specific function keys and dual purpose scroll/shortcut keys |
| Outputs | USB (2), RS232 |
| Temperature Range (English) | 22.0°F to 221.0° F |
| Range (Relative mV) | ±2000.0 mV |
| Calibration Points (pH) | 1 to 6 |
| Backlight Option | Yes |
| Weight (English) | 2.5 lb., modules add 0.5 lb. each |
| Temperature (Metric) Operating | 5°C to 45°C (ambient) |
| Temperature Range (Metric) | -5.0°C to +105.0°C |
| Range (mV) | ±2000.0 mV |
| Range (ORP) | ±2000.0 mV |
| Methods | 10 per channel |
| Temperature Resolution | 0.1°C, 0.1°F |
Thermo Scientific™ Elite pH Pocket Testers and Replacement Sensors
Flexible on-the-go pH and temperature testing using durable Elite pocket testers with replaceable sensors for a variety of applications including environmental monitoring, pools, spas and more!
Thermo Scientific™ Orion Star™ A221 Portable pH Meter
Reliably measure pH, mV, ORP and temperature with our portable pH meter for advanced field analysis and printer or computer interfacing.
Thermo Scientific™ Expert CTS Pocket Tester
Ensure accurate measurements of Conductivity, TDS, Salinity, and Temperature using the easy-to-use, large 4-digit display pocket tester for many applications.
Thermo Scientific™ Elite CTS Conductivity / TDS / Salinity Cup-sensor Pocket Testers and Replacement Sensors
Flexible on-the-go conductivity, TDS, salinity and temperature testing using durable Elite CTS cup-sensor pocket testers for a variety of applications including agriculture, aquariums and more!
| Salinity Measurement Modes | Per practical salinity curve |
|---|---|
| Temperature Accuracy | ±0.6°C, ±1.0°F for 0.0 to 50.0°C; ±1.1°C, ±1.9°F for 50.1 to 60.0°C |
| Resolution (Conductivity) | 0.1 μS/cm for 0.0 to 200.0 μS/cm; 1 μS/cm for200 to 2000 μS/cm; 0.01 mS/cm for 2.00 to 20.00 mS/cm |
| Range (Conductivity) | 0.00 to 20.00 mS/cm |
| Range (TDS) | 0.00 to 10.00 ppt |
| Measurement Modes | Conductivity,TDS,Salinity,Temperature |
| Resolution (TDS) | 0.1 ppm for 0.0 to 100.0 ppm; 1 ppm for 100 to 1000 ppm; 0.01 ppt for 0.10 to 10.00 ppt |
| TDS Factor Range | 0.40 to 1.00 (selectable) |
| Relative Humidity Range | 5 to 85 %, non-condensing |
| Range (Salinity) | 0.00 to 10.00 ppt |
| Temperature Compensation | Yes |
| Accuracy (TDS) | ± 1% full scale |
| Accuracy (Salinity) | ± 1% full scale |
| Resolution (Salinity) | 0.10 ppt |
| Accuracy (Conductivity) | ± 1% full scale |
| Temperature Range (English) | 32.0°F to 140.0°F |
| Temperature Probe Calibration | 1 point |
| Temperature (Metric) Operating | 5°C to 45°C (ambient) |
| Temperature Resolution | 0.1°C, 0.1°F |
| Calibration Points (Conductivity) | 1 to 3 |
Thermo Scientific™ Expert pH Pocket Tester
Perform on-the-go, fuss-free measurements for applications such as water treatment, environmental monitoring, education, hydroponics, agriculture, aquaculture, food & beverage and many more!
Fisherbrand™ accumet™ AR450 pH/ion/Conductivity Meter Kit
Designed to deliver precise and reliable electrochemistry testing, the accumet AR450 offers enhanced performance in a streamlined design. Ideal for laboratories requiring dependable measurement capabilities.
Thermo Scientific™ Orion Star™ A324 pH/ISE Portable Multiparameter Meter
Accurately monitor pH, ion concentration, mV, ORP and temperature with our pH/ISE portable meter for challenging field testing.
| Memory | Non-volatile memory preserves data log, calibration log and meter settings |
|---|---|
| Advanced ISE Functions | Segmented (point-to-point) slope, non-linear selectable auto-blank, low concentration range stabilit |
| Languages | English, Spanish, French, Italian, German and Chinese; Portuguese and Korean available with software update |
| Measurement Modes | pH,mV,Relative mV,ORP,Ion Concentration (ISE) with Temperature |
| Range (pH) | -2 to 20 |
| Accuracy (pH) | ±0.002 |
| Range (ISE) | 0.0001 to 19900 with selectable units of ppm, Molar, mg/L, %, ppb or none |
| Power Supply | 4 AA batteries (included) or universal AC adapter (sold separately) |
| Data Management Details | Transfer single, range or all data points to printer or computer |
| Battery Life | 800 hr. |
| Display Type | LCD Graphic, Backlit |
| Resolution (mV) | 0.1mV |
| Data Points | 5000 with Date and Time Stamp |
| Temperature Probe Calibration | 1 point temperature offset calibration |
| Certifications/Compliance | CE, TUV 3-1, FCC Class A |
| Inputs | BNC (pH, ORP or ion selective electrode), pin-tip (reference electrode), 8 pin MiniDIN (ATC temperature probe) |
| Weight (Metric) | 0.5 kg |
| Accuracy (mV) | ±0.2 mV or ±0.05% of reading whichever is greater |
| Accuracy (ISE) | ±0.2 mV or ±0.05% of reading whichever is greater |
| Warranty | 3 Year Meter |
| Temperature Accuracy | ±0.1°C |
| Stability | Selectable fast, medium, slow or Smart Stability setting; Selectable off or Automatic Smart averaging setting |
| Calibration Points (ISE) | 1 to 5 |
| Temperature (English) Operating | 41°F to 113°F (ambient) |
| Isopotential Point | 7.000pH |
| AC Adapter | Universal 50-60 Hz, 100-240 VAC power adapter (sold separately, Cat. No. 1010003) |
| Log Function Type | Automatic data logging with Auto-Read and Timed measure modes; manual data logging with Continuous m |
| Calibration | pH with calibration editing option, ion concentration (ISE) with calibration editing option, relativ |
| Battery Type | 4 AA (included) |
| Relative Humidity Range | 5 to 85 %, non-condensing |
| Calibration Points | 1 point relative mV (RmV) mode, 1 point ORP mode |
| Alarm Output | High/low limit alarm, calibration due alarm |
| Dimensions (L x W x H) | 24cm x 10cm x 6.5cm (9.5 in. x 3.9 in. x 2.6 in.) |
| Temperature Selection | Manual or automatic with ATC temperature probe |
| IP Rating | IP67 |
| Keypad | Comprehensive with menu-specific function keys and dual purpose scroll/shortcut keys |
| Model | Orion Star A324 pH/ISE/mV/RmV/ORP/Temperature Portable Meter |
| Outputs | USB, RS232 |
| Temperature Range (English) | 22.0°F to 221.0° F |
| Range (Relative mV) | ±2000.0 mV |
| Calibration Points (pH) | 1 to 5 |
| Backlight Option | Yes (Selectable) |
| Weight (English) | 1.2 lb. |
| Temperature (Metric) Operating | 5°C to 45°C (ambient) |
| Temperature Range (Metric) | -5.0°C to +105.0°C |
| Range (mV) | ±2000.0 mV |
| Range (ORP) | ±2000.0 mV |
| Methods | 10 per channel with password protection |
| Temperature Resolution | 0.1°C, 0.1°F |
Thermo Scientific™ Orion Star™ A326 pH/Dissolved Oxygen Portable Multiparameter Meter
Accurately measure pH, dissolved oxygen and temperature with our pH/DO/RDO portable meter for high performance in challenging field tests.
| Resolution (Polarographic DO) | 0.01, 0.1mg/L |
|---|---|
| Pressure Range | 400 to 850mmHg |
| Memory | Non-volatile memory preserves data log, calibration log and meter settings |
| Languages | English, Spanish, French, Italian, German and Chinese; Portuguese and Korean available with software update |
| Measurement Modes | pH,mV,Relative mV,ORP with Temperature,Dissolved Oxygen (% Saturation),Dissolved Oxygen (mg/L with Temperature) |
| Power Supply | 4 AA batteries (included) or universal AC adapter (sold separately) |
| Barometric Pressure Correction | 400 to 850mmHg, automatic using built-in barometer or manual entry |
| Data Management Details | Transfer single, range or all data points to printer or computer |
| Battery Life | 800 hr. |
| Display Type | LCD Graphic, Backlit |
| Resolution (mV) | 0.1mV |
| Data Points | 5000 with Date and Time Stamp |
| Calibration Modes | Water-saturated air, air-saturated water, manual (Winkler titration), zero point |
| Temperature Probe Calibration | 1 point temperature offset calibration |
| Certifications/Compliance | CE, TUV 3-1, FCC Class A |
| Salinity Factor | 0.0 to 45.0 ppt, automatic correction using manual entry of sample salinity |
| Accuracy (mV) | ±0.2 mV or ±0.05% of reading whichever is greater |
| Warranty | 3 Year Meter |
| Temperature Accuracy | ±0.1°C |
| Stability | Selectable fast, medium, slow or Smart Stability setting; Selectable off or Automatic Smart averaging setting |
| Log Function Type | Automatic data logging with Auto-Read and Timed measure modes; manual data logging with Continuous m |
| Battery Type | 4 AA (included) |
| Relative Humidity Range | 5 to 85 %, non-condensing |
| Range (RDO) | 0.00 to 50.00mg/L |
| Dimensions (L x W x H) | 24cm x 10cm x 6.5cm (9.5 in. x 3.9 in. x 2.6 in.) |
| Temperature Selection | Manual or automatic with ATC temperature probe |
| Percent Saturation Range (RDO) | 0.0 to 500.0 % saturation |
| Keypad | Comprehensive with menu-specific function keys and dual purpose scroll/shortcut keys |
| Outputs | USB, RS232 |
| Temperature Range (English) | 22.0°F to 221.0° F |
| Range (Relative mV) | ±2000.0 mV |
| Calibration Points (pH) | 1 to 5 |
| Backlight Option | Yes (Selectable) |
| Percent Saturation Relative Accuracy (RDO) | ±2 % saturation ≤ 200 % saturation, ±10 % saturation > 200 % saturation |
| Range (Polarographic DO) | 0.00 to 90.00mg/L |
| Range (mV) | ±2000.0 mV |
| Accuracy (Barometer) | ±6mmHg |
| Range (ORP) | ±2000.0 mV |
| Methods | 10 per channel with password protection |
| Pressure Resolution | 1mmHg |
| Range (pH) | -2 to 20 |
| Accuracy (pH) | ±0.002 |
| Resolution (RDO) | 0.01, 0.1mg/L |
| Percent Saturation Resolution (RDO) | 0.1, 1 % saturation |
| Percent Saturation Relative Accuracy (Polarographic DO) | ±2 % saturation or ±2% of reading whichever is greater |
| Inputs | BNC (pH or ORP electrode), pin-tip (reference electrode), 8 pin MiniDIN (ATC temperature probe), 9 pin MiniDIN (RDO optical or polarographic DO sensor with built-in temperature) |
| Weight (Metric) | 0.5 kg |
| Temperature (English) Operating | 41°F to 113°F (ambient) |
| Isopotential Point | 7.000pH |
| Accuracy (Polarographic DO) | ±0.2mg/L or ±2% of reading, whichever is greater |
| AC Adapter | Universal 50-60 Hz, 100-240 VAC power adapter (sold separately, Cat. No. 1010003) |
| Calibration | pH with calibration editing option, relative mV (RmV), ORP, dissolved oxygen and temperature |
| Calibration Points | 1 point relative mV (RmV) mode, 1 point ORP mode |
| Alarm Output | High/low limit alarm, calibration due alarm |
| IP Rating | IP67 |
| Percent Saturation Resolution (Polarographic DO) | 0.1, 1 % saturation |
| Model | Orion Star A326 pH/mV/RmV/ORP/RDO Optical/Dissolved Oxygen/Temperature Portable Meter |
| Weight (English) | 1.2 lb. |
| Temperature (Metric) Operating | 5°C to 45°C (ambient) |
| Temperature Range (Metric) | -5.0°C to +105.0°C |
| Percent Saturation Range (Polarographic DO) | 0.0 to 600.0 % saturation |
| Temperature Resolution | 0.1°C, 0.1°F |
| Accuracy (RDO) | ±0.1mg/L up to 8mg/L, ±0.2mg/L from 8 to 20mg/L, ±10% of reading up to 50mg/L |
Thermo Scientific™ Orion Star™ A329 pH/ISE/Conductivity/Dissolved Oxygen Portable Multiparameter Meter
Accurately measure pH, ion concentration, conductivity, dissolved oxygen and temperature with our pH/ISE/conductivity/RDO/DO portable meter.
| Salinity Measurement Modes | Practical salinity (psu) or natural sea water (ppt) |
|---|---|
| Resolution (Polarographic DO) | 0.01, 0.1mg/L |
| Pressure Range | 400 to 850mmHg |
| Range (Resistivity) | 2 ohm to 100.0 meg-ohm |
| Memory | Non-volatile memory preserves data log, calibration log and meter settings |
| Advanced ISE Functions | Segmented (point-to-point) slope, non-linear selectable auto-blank, low concentration range stabilit |
| Languages | English, Spanish, French, Italian, German and Chinese; Portuguese and Korean available with software update |
| Measurement Modes | pH,mV,Relative mV,TDS,ORP with Temperature,Salinity,Conductivity,Resistivity with Temperature |
| Power Supply | 4 AA batteries (included) or universal AC adapter (sold separately) |
| Barometric Pressure Correction | 400 to 850mmHg, automatic using built-in barometer or manual entry |
| Data Management Details | Transfer single, range or all data points to printer or computer |
| Battery Life | 800 hr. |
| Display Type | LCD Graphic, Backlit |
| Resolution (mV) | 0.1mV |
| Data Points | 5000 with Date and Time Stamp |
| Calibration Modes | Water-saturated air, air-saturated water, manual (Winkler titration), zero point |
| Temperature Probe Calibration | 1 point temperature offset calibration |
| Certifications/Compliance | CE, TUV 3-1, FCC Class A |
| Salinity Factor | 0.0 to 45.0 ppt, automatic correction using conductivity reading or manual entry of sample salinity |
| Accuracy (mV) | ±0.2 mV or ±0.05% of reading whichever is greater |
| Accuracy (ISE) | ±0.2 mV or ±0.05% of reading whichever is greater |
| Warranty | 3 Year Meter |
| Temperature Accuracy | ±0.1°C |
| Stability | Selectable fast, medium, slow or Smart Stability setting; Selectable off or Automatic Smart averaging setting |
| Calibration Points (ISE) | 1 to 5 |
| Resolution (Conductivity) | 0.001 μS minimum, auto ranging up to 4 significant digits |
| Range (Conductivity) | 0.001 μS/cm to 3000 mS/cm |
| Log Function Type | Automatic data logging with Auto-Read and Timed measure modes; manual data logging with Continuous m |
| Battery Type | 4 AA (included) |
| Relative Humidity Range | 5 to 85 %, non-condensing |
| Range (RDO) | 0.00 to 50.00mg/L |
| Dimensions (L x W x H) | 24cm x 10cm x 6.5cm (9.5 in. x 3.9 in. x 2.6 in.) |
| Accuracy (TDS) | 0.5% of reading ±1 digit |
| Temperature Selection | Manual or automatic with ATC temperature probe |
| Percent Saturation Range (RDO) | 0.0 to 500.0 % saturation |
| Keypad | Comprehensive with menu-specific function keys and dual purpose scroll/shortcut keys |
| Outputs | USB, RS232 |
| Temperature Range (English) | 22.0°F to 221.0° F |
| Range (Relative mV) | ±2000.0 mV |
| Calibration Points (pH) | 1 to 5 |
| Backlight Option | Yes (Selectable) |
| Percent Saturation Relative Accuracy (RDO) | ±2 % saturation ≤ 200 % saturation, ±10 % saturation > 200 % saturation |
| Range (Polarographic DO) | 0.00 to 90.00mg/L |
| Range (mV) | ±2000.0 mV |
| Accuracy (Barometer) | ±6mmHg |
| Range (ORP) | ±2000.0 mV |
| Methods | 10 per channel with password protection |
| Pressure Resolution | 1mmHg |
| Cell Constant | 0.001 to 199.9cm-1 |
| Temperature (Metric) Reference | 5, 10, 15, 20, 25°C |
| Range (pH) | -2 to 20 |
| TDS Factor Range | Linear (0.02 to 9.99) |
| Accuracy (pH) | ±0.002 |
| Range (ISE) | 0.0001 to 19900 with selectable units of ppm, Molar, mg/L, %, ppb or none |
| Range (Salinity) | 0.06 to 80.00 psu, 0.05 to 42.00 ppt |
| Resolution (RDO) | 0.01, 0.1mg/L |
| Temperature Compensation | Linear, nLFn (non-linear ultra pure water), nLFu (non-linear ultra pure degassed water), EP (off with warning) or off |
| Accuracy (Salinity) | 0.5% of reading ±1 digit |
| Resolution (Salinity) | 0.01 psu or 0.01 ppt minimum, auto ranging |
| Percent Saturation Resolution (RDO) | 0.1, 1 % saturation |
| Accuracy (Conductivity) | 0.5% of reading ±1 digit > 3 μS; 0.5% of reading ±0.01 μS ≤ 3 μS |
| Percent Saturation Relative Accuracy (Polarographic DO) | ±2 % saturation or ±2% of reading whichever is greater |
| Inputs | BNC (pH or ORP electrode), pin-tip (reference electrode), 8 pin MiniDIN (conductivity sensor with built-in temperature or ATC temperature probe), 9 pin MiniDIN (RDO optical or polarographic DO sensor with built-in temperature) |
| Weight (Metric) | 0.5 kg |
| Calibration Points (Conductivity) | Up to 5 |
| Temperature (English) Operating | 41°F to 113°F (ambient) |
| Resolution (Resistivity) | 1 ohm or 0.1 meg-ohm, auto ranging |
| Isopotential Point | 7.000pH |
| Accuracy (Polarographic DO) | ±0.2mg/L or ±2% of reading, whichever is greater |
| Accuracy (Resistivity) | 0.5% of reading ±1 digit |
| AC Adapter | Universal 50-60 Hz, 100-240 VAC power adapter (sold separately, Cat. No. 1010003) |
| Range (TDS) | 0.001 ppm to 200.0 ppt |
| Resolution (TDS) | 0.001 ppm minimum, auto ranging up to 4 significant digits |
| Calibration | pH with calibration editing option, ion concentration (ISE) with calibration editing option, relativ |
| Calibration Points | 1 point relative mV (RmV) mode, 1 point ORP mode |
| Alarm Output | High/low limit alarm, calibration due alarm |
| IP Rating | IP67 |
| Percent Saturation Resolution (Polarographic DO) | 0.1, 1 % saturation |
| Model | Orion Star A329 pH/ISE/mV/RmV/ORP/Conductivity/TDS/Salinity/Resistivity/RDO Optical/Dissolved Oxygen/Temperature Portable Meter |
| Weight (English) | 1.2 lb. |
| Temperature (Metric) Operating | 5°C to 45°C (ambient) |
| Temperature Range (Metric) | -5.0°C to +105.0°C |
| Percent Saturation Range (Polarographic DO) | 0.0 to 600.0 % saturation |
| Temperature Resolution | 0.1°C, 0.1°F |
| Accuracy (RDO) | ±0.1mg/L up to 8mg/L, ±0.2mg/L from 8 to 20mg/L, ±10% of reading up to 50mg/L |