Filtration Membrane Discs
Thin, precut membrane rounds for high-throughput, fast filtration of liquid and gas samples. Gridded and non-gridded discs. Various materials including mixed cellulose ester, polycarbonate, PTFE, nylon, and PVDF. For air monitoring/analytical research.
Sizes
Filter membranes are made in a range of diameters, typically designed to fit a specific holder or manifold.
Materials
Filter membrane can be made from cellulose, mixed cellulose esters (MCE), polyvinylidene fluoride (PVDF), polyethersulfone (PES), polyvinyl chloride (PVC), polytetrafluoroethylene (PTFE), nylon, polycarbonate (PC), polyester, polyethylene terephthalate (PET), and polypropylene (PP). Other membrane materials include aluminum oxide, gelatin, porcelain, and glass.
Pore Size
The size of membrane pores determines which particles will be retained by the filter. A pore size of 0.2 µm is small enough to remove microbes from solutions; a 0.45 µm ore size can remove larger particulates.
Color and Grids
White membrane filters may be plain or marked with square grids (outlined in black) that can help with enumerating particles. Gridded or plain black membrane filters may be helpful when filtering light-colored particulates.
Sterility
Filter membranes may be pre-sterilized or may be sterilized using ethylene oxide, gamma irradiation, or autoclaves. The need for sterility is determined by the application, which are many and varied:
- Light microscopy samples
- Cytology sample preparation
- Electron microscopy samples
- Air quality and other environmental monitoring
- Water analysis and water quality testing
- Microbiology colony counting and quality control
- Chemotaxis
- Sterile preparation of buffers, tissue culture media, microbiological media, and other biological fluids
- (4)
- (5)
- (14)
- (6)
- (28)
- (5)
- (3)
- (5)
- (1)
- (14)
- (14)
- (3)
- (2)
- (7)
- (1)
- (7)
- (101)
- (1)
- (58)
- (23)
- (3)
- (1)
- (1)
- (24)
- (1)
- (21)
- (3)
Filtered Search Results
Cytiva Whatman™ Mixed Cellulose Ester Membrane Filters
Whatman™ Mixed Cellulose Ester Membrane Filters are biologically inert and offers high degree of internal surface area for greater product adsorption.
| Material | MCE |
|---|---|
| Autoclavable | Autoclavable |
| Sterility | Sterile |
MilliporeSigma™ MF-Millipore™ Mixed Cellulose Ester Membranes, Triton-free
MF-Millipore™ Mixed Cellulose Ester Membranes, Triton-free composed of mixed cellulose esters (nitrate and acetate).
| Disposable | Reusable |
|---|---|
| Wettability | Hydrophilic |
| Format | Disc |
| Color | White |
| Material | MCE |
| Filter Type | Membrane Filter |
| For Use With (Application) | Clarification of fluids, Sterilizing filtration of tissue culture media, additives, antibiotics, Air monitoring, Particulate analysis, Particulate removal, Biological assays (receptor binding studies, TCA precipitates, etc.). |
| Autoclavable | Not Autoclavable |
| Sterility | Non-sterile |
| Membrane Type | Plain |
MilliporeSigma™ MF-™ Mixed Cellulose Ester Membranes: Triton-free
Composed of mixed cellulose esters (nitrate and acetate) with minimal amounts of wetting agent. MilliporeSigma™ MF-Millipore™ Mixed Cellulose Ester Membranes: Triton-free are designed for critical applications involving sensitive biological solutions, cell contact or very small volumes.
Cytiva Whatman™ ME 25 Plain Mixed Cellulose Ester Membranes
Facilitates the counting process and minimizes eye fatigue with color contrast between the surface and the colonies. Whatman™ ME 25 Plain Mixed Cellulose Ester Membranes are characterized by a smooth and more uniform surface.
| Thickness (Metric) | 145 μm |
|---|---|
| Includes | Interleaving paper |
| Pore Size | 0.45 μm |
| Bubble Point | 2.8 bar |
| Flow Rate | 12.5 sec./100 mL/12.5 cm2 |
| Material | Cellulose Acetate, Cellulose Nitrate |
| Autoclavable | Autoclavable |
| Membrane Type | ME25 |
Cytiva Whatman™ ME 24 Plain Mixed Cellulose Ester Membranes
Enables the uptake of growth media to the bacterial colonies without chemically inhibiting their growth. Whatman™ ME 24 Plain Mixed Cellulose Ester Membranes are composed of cellulose acetate and cellulose nitrate, which provides a more uniform surface.
| Thickness (Metric) | 135 μm |
|---|---|
| Includes | Interleaving paper |
| Pore Size | 0.2 μm |
| Bubble Point | 3.7bar |
| Flow Rate | 20s/100mL/12.5cm2 |
| Grid Color | Plain |
| Material | MCE |
| Autoclavable | Autoclavable |
| Membrane Type | ME24 |
Cytiva Whatman™ Sterile Mixed Cellulose Ester Gridded Membranes
Composed of cellulose acetate and cellulose nitrate.
GVS Mixed Cellulose Esters (MCE) Membrane
GVS Mixed Cellulose Esters (MCE) Membranes are hydrophilic and available in pore Sizes from 0.1 to 8 μm.
| Includes | Without Grid |
|---|---|
| Disposable | Single-use |
| Type | Membrane Filter |
| Color | White |
| Material | MCE |
| Filter Type | Microporous Filter |
| Sterility | Non-sterile |
Cytiva Whatman™ 1.2μm Pore Size (ME 28) Mixed Cellulose Ester Membranes
Cytiva Whatman 1.2um Pore Size (ME 28) Mixed Cellulose Ester Membranes, Diameter Filter: 47mm, Pore Size: 0.2um
| Pore Size | 1.2 μm |
|---|
Cytiva Whatman™ 3 μm Pore Size (ME 29) Mixed Cellulose Ester Membranes, Plain
Whatman™ (ME 29) Mixed Cellulose Ester Membranes, Plain are particularly effective in applications requiring higher flow rates and larger volume filtration including clarification or sterilization of aqueous solutions, particulate analysis and removal, air monitoring, and microbial analysis.
| Pore Size | 3 μm |
|---|---|
| Flow Rate | 1.2 sec./100 mL/12.5 cm² (at Δp = 0.9 bar) |
| Material (Membrane) | ME 29 |
| Material | MCE |
| Surface Type | Plain |
| For Use With (Application) | Filtration, cytology, air monitoring, aqueous HPLC samples, biological assays |
| Autoclavable | Autoclavable |
| Sterility | Non-sterile |
| Gas Flow Rate | 6.7 sec./100 mL (at Δp = 3 mbar) |
Cytiva Whatman™ 0.6 μm Pore Size (ME 26) Mixed Cellulose Ester Membranes, Plain
Whatman™ (ME 26) Mixed Cellulose Ester Membranes are particularly effective in applications requiring higher flow rates and larger volume filtration, including clarification or sterilization of aqueous solutions, particulate analysis and removal, air monitoring, and microbial analysis.
| Pore Size | 0.6 μm |
|---|---|
| Disposable | Single-use |
| Bubble Point | 3.7 bar |
| Flow Rate | 4.8 sec./100 mL/12.5cm² (at Δp = 0.9 bar) |
| Material (Membrane) | ME 26 |
| Grid Color | Plain |
| Material | MCE |
| Surface Type | Plain |
| For Use With (Application) | Filtration, cytology, air monitoring, aqueous HPLC samples, biological assays |
| Autoclavable | Autoclavable |
| Sterility | Non-sterile |
| Gas Flow Rate | 21 sec./100 mL (at Δp = 3 mbar) |
Cytiva Whatman™ 0.8 μm Pore Size (ME 27) Mixed Cellulose Ester Membranes, Plain
Whatman™ (ME 27) Mixed Cellulose Ester Membranes, Plain are particularly effective in applications requiring higher flow rates and larger volume filtration including clarification or sterilization of aqueous solutions, particulate analysis and removal, air monitoring, and microbial analysis.
| Pore Size | 0.8 μm |
|---|---|
| Bubble Point | 1.3 bar |
| Flow Rate | 2.8 sec./100 mL/12.5 cm⊃ (at Δp = 0.9 bar) |
| Material (Membrane) | ME 27 |
| Grid Color | Plain |
| Material | MCE |
| Surface Type | Plain |
| For Use With (Application) | Filtration, cytology, air monitoring, aqueous HPLC samples, biological assays |
| Autoclavable | Autoclavable |
| Sterility | Non-sterile |
| Gas Flow Rate | 11.6 sec./100 mL (at Δp = 3 mbar) |
Cytiva Whatman™ 0.8 μm Pore Size (ME 27) Mixed Cellulose Ester Membranes, White/Black Grid
Whatman™ (ME 27) Mixed Cellulose Ester Membranes, White/Black Grid are particularly effective in applications requiring higher flow rates and larger volume filtration. Supplied with clearly defined grid lines at regularly spaced intervals to assist in microbiological colony counting.
| Pore Size | 0.8 μm |
|---|---|
| Diameter (English) | 1.85 in. |
| Material (Membrane) | ME 27 |
| Color | White |
| Grid Color | Black |
| Quantity | 100 Pk. |
| Material | MCE |
| For Use With (Application) | Filtration, cytology, air monitoring, aqueous HPLC samples, biological assays |
| Sterility | Sterile |
| Thickness (Metric) | 140 μm |
| Bubble Point | 1.3 bar |
| Flow Rate | 2.8 sec./100 mL/12.5 cm2 (at Δp = 0.9 bar) |
| Diameter (Metric) | 47 mm |
| Thickness (English) | 0.006 in. |
| Autoclavable | Autoclavable |
| Size (Metric) Grid | 3.1 mm |
| Gas Flow Rate | 11.6 sec./100 mL (at Δp = 3 mbar) |
Cytiva Whatman™ 0.45 μm Pore Size (ME 25) Mixed Cellulose Ester Membranes, White/Black Grid
Whatman™ (ME 25) Mixed Cellulose Ester Membranes, White/Black Grid are particularly effective in applications requiring higher flow rates and larger volume filtration. Supplied with clearly defined grid lines at regularly spaced intervals to assist in microbiological colony counting.
GVS Nitrocellulose-Mixed Esters of Cellulose Membrane Filters
Uniform microporous structure has low extractables, low ash
| Material | MCE |
|---|---|
| Hydrophobicity | Hydrophilic |
| For Use With (Application) | Microbiological determinations; industrial hygiene procedures; clarifying aqueous solutions; determination of lead, chromium, cadmium, beryllium, arsenic, airborne asbestos and other particulates. |