Filtration Membrane Discs
Thin, precut membrane rounds for high-throughput, fast filtration of liquid and gas samples. Gridded and non-gridded discs. Various materials including mixed cellulose ester, polycarbonate, PTFE, nylon, and PVDF. For air monitoring/analytical research.
Sizes
Filter membranes are made in a range of diameters, typically designed to fit a specific holder or manifold.
Materials
Filter membrane can be made from cellulose, mixed cellulose esters (MCE), polyvinylidene fluoride (PVDF), polyethersulfone (PES), polyvinyl chloride (PVC), polytetrafluoroethylene (PTFE), nylon, polycarbonate (PC), polyester, polyethylene terephthalate (PET), and polypropylene (PP). Other membrane materials include aluminum oxide, gelatin, porcelain, and glass.
Pore Size
The size of membrane pores determines which particles will be retained by the filter. A pore size of 0.2 µm is small enough to remove microbes from solutions; a 0.45 µm ore size can remove larger particulates.
Color and Grids
White membrane filters may be plain or marked with square grids (outlined in black) that can help with enumerating particles. Gridded or plain black membrane filters may be helpful when filtering light-colored particulates.
Sterility
Filter membranes may be pre-sterilized or may be sterilized using ethylene oxide, gamma irradiation, or autoclaves. The need for sterility is determined by the application, which are many and varied:
- Light microscopy samples
- Cytology sample preparation
- Electron microscopy samples
- Air quality and other environmental monitoring
- Water analysis and water quality testing
- Microbiology colony counting and quality control
- Chemotaxis
- Sterile preparation of buffers, tissue culture media, microbiological media, and other biological fluids
- (1)
- (4)
- (5)
- (1)
- (4)
- (31)
- (127)
- (46)
- (3)
- (24)
- (195)
- (39)
- (10)
- (22)
- (6)
- (87)
- (7)
- (18)
- (50)
- (17)
- (1)
- (6)
- (5)
- (2)
- (3)
- (15)
- (23)
- (2)
- (59)
- (5)
- (23)
- (11)
- (1)
- (72)
- (8)
- (161)
- (3)
- (3)
- (1)
- (173)
- (1)
- (3)
- (5)
- (57)
- (28)
- (18)
- (93)
- (1)
- (1)
- (45)
- (14)
- (87)
- (4)
- (6)
- (6)
- (21)
- (1)
- (1)
- (504)
- (114)
- (1)
- (2)
- (1)
- (2)
- (335)
- (3)
- (5)
- (3)
- (160)
- (323)
- (3)
Filtered Search Results
Cytiva Whatman™ 90 mm Nuclepore™ Polycarbonate Track-Etched Membranes
Manufactured from high-quality polycarbonate film and track-etched for high pore size precision. Whatman™ Polycarbonate Hydrophilic Membranes combine high flow rates and chemical and thermal resistance with sharply defined pores, making them suitable for microscopy, cytology, parasitology, and certain air and oceanography analyses.
| Flow Rate | High |
|---|---|
| Diameter (Metric) | 90 mm |
| Material | Nucleopore Polycarbonate |
| Hydrophobicity | Hydrophilic |
| For Use With (Application) | Epifluorescence microscopy, environmental analysis, cell biology |
Cytiva Whatman™ 47 mm Nuclepore™ Polycarbonate Track-Etched Membranes
Manufactured from high-quality polycarbonate film and track-etched for high pore size precision. Whatman™ 47mm Nuclepore™ Polycarbonate Hydrophilic Membranes combine high flow rates and chemical and thermal resistance with sharply defined pores, making them suitable for microscopy, cytology, parasitology, and certain air and oceanography analyses.
| Flow Rate | High |
|---|---|
| Diameter (Metric) | 47 mm |
| Material | Nucleopore Polycarbonate |
| Hydrophobicity | Hydrophilic |
| For Use With (Application) | Epifluorescence microscopy, environmental analysis, cell biology |
GVS Poretics™ 13 mm Polycarbonate Disc
Made from a thin, microporous polycarbonate film material. It is ideally suited for use in blood assays and high-purity and general filtration. Though polycarbonate is hydrophobic, the membrane is treated with a wetting agent to make it hydrophilic.
| Disposable | Limited-use |
|---|---|
| Type | Disc Membrane |
| Format | Disc |
| Material | PCTE |
| Filter Type | Membrane Filter |
| Sterility | Non-sterile |
Thermo Scientific™ Nalgene™ Membrane and Prefilter Disks
Greener Choice
Offers one or more environmental benefits itemized in the U.S. FTC Green Guides.
Learn More
Offers one or more environmental benefits itemized in the U.S. FTC Green Guides.
Learn More
Carry out particulate and microbial analysis with these filter membranes. Available in various forms for water quality work, cold sterilization or sample clean up.
MilliporeSigma™ Hydrophilic Nylon Membrane Filter
For use in clarification of aqueous solutions, particle removal and analysis.
MilliporeSigma Millipore Polypropylene Membrane Filter, 0.2 μm
Hydrophobic polypropylene filters in 25, 47, and 90 mm sizes offer reliable aqueous filtration, low extractables, and consistent flow for lab use
| Sterility | Non-sterile |
|---|
MilliporeSigma Millipore Polypropylene Membrane Filter, 0.45 μm
Hydrophobic polypropylene filters in 25, 47, and 90 mm sizes offer reliable aqueous filtration, low extractables, and consistent flow for lab use
| Sterility | Non-sterile |
|---|
MilliporeSigma Millipore Polypropylene Membrane Filter, 0.45 μm
Hydrophilic polypropylene filters in 25, 47, and 90 mm sizes offer reliable aqueous filtration, low extractables, and consistent flow for lab use
| Sterility | Non-sterile |
|---|
MilliporeSigma Millipore Polypropylene Membrane Filter, 0.2 μm
Hydrophilic polypropylene filters in 25, 47, and 90 mm sizes offer reliable aqueous filtration, low extractables, and consistent flow for lab use
| Sterility | Non-sterile |
|---|
Cytiva Whatman™ PTFE Membrane Circles
Provides clarification of corrosives, solvents, and aggressive fluids. Whatman™ PTFE Membrane Circles are particularly useful in HPLC analysis when solid particles can cause permanent damage to the column.
| Material | PTFE |
|---|---|
| Hydrophobicity | Hydrophobic |
MilliporeSigma™ MF-Millipore™ Membrane Filter, 0.1 μm
13 mm diameter, mixed cellulose esters (MCE) membrane, hydrophilic
| Thickness (Metric) | 105 μm |
|---|---|
| Pore Size | 0.1 μm |
| Flow Rate | 1.5 mL/min x cm2 |
| Wettability | Hydrophilic |
| Type | Filter Membranes |
| Color | White |
| Material | MCE |
| Autoclavable | Not Autoclavable |
| Sterility | Non-sterile |
MilliporeSigma™ MF-Millipore™ Membrane Filter, 0.05 μm
13 mm diameter, mixed cellulose esters (MCE) membrane, hydrophilic
| Thickness (Metric) | 105 μm |
|---|---|
| Pore Size | 0.05 μm |
| Flow Rate | 0.74 mL/min x cm2 |
| Wettability | Hydrophilic |
| Type | Filter Membranes |
| Color | White |
| Material | MCE |
| Autoclavable | Not Autoclavable |
| Sterility | Non-sterile |
MilliporeSigma™ MF-Millipore™ Membrane Filter, 1.2 μm
Mixed cellulose esters (MCE) membrane, hydrophilic
| Pore Size | 1.2 μm |
|---|---|
| Flow Rate | 270 mL/min x cm2 |
| Wettability | Hydrophilic |
| Type | Filter Membranes |
| Color | White |
| Material | MCE |
| Hydrophobicity | Hydrophilic |
| Autoclavable | Not Autoclavable |
| Sterility | Non-sterile |
| Membrane Type | Plain |
Cytiva Whatman™ Nylon Membranes
Flexible and durable for easier handling. Cytiva Nylon Membranes are naturally hydrophilic, eliminating need for wetting agents and prewetting when filtering aqueous solutions.
| Material | Nylon |
|---|---|
| Hydrophobicity | Hydrophilic |
| Autoclavable | Autoclavable |
MilliporeSigma™ MF-Millipore™ Membrane Filter, 0.025 μm
MF-Millipore™ Membrane Filter is a 13 mm diameter, mixed cellulose esters (MCE) membrane, hydrophilic.
| Thickness (Metric) | 105 μm |
|---|---|
| Pore Size | 0.025 μm |
| Disposable | Reusable |
| Flow Rate | 0.15 mL/min. x cm2 |
| Wettability | Hydrophilic |
| Type | Filter Membranes |
| Format | Disc |
| Material | MCE |
| Filter Type | Membrane Filter |
| Autoclavable | Not Autoclavable |
| Sterility | Non-sterile |