Filtration Membrane Discs
Thin, precut membrane rounds for high-throughput, fast filtration of liquid and gas samples. Gridded and non-gridded discs. Various materials including mixed cellulose ester, polycarbonate, PTFE, nylon, and PVDF. For air monitoring/analytical research.
Sizes
Filter membranes are made in a range of diameters, typically designed to fit a specific holder or manifold.
Materials
Filter membrane can be made from cellulose, mixed cellulose esters (MCE), polyvinylidene fluoride (PVDF), polyethersulfone (PES), polyvinyl chloride (PVC), polytetrafluoroethylene (PTFE), nylon, polycarbonate (PC), polyester, polyethylene terephthalate (PET), and polypropylene (PP). Other membrane materials include aluminum oxide, gelatin, porcelain, and glass.
Pore Size
The size of membrane pores determines which particles will be retained by the filter. A pore size of 0.2 µm is small enough to remove microbes from solutions; a 0.45 µm ore size can remove larger particulates.
Color and Grids
White membrane filters may be plain or marked with square grids (outlined in black) that can help with enumerating particles. Gridded or plain black membrane filters may be helpful when filtering light-colored particulates.
Sterility
Filter membranes may be pre-sterilized or may be sterilized using ethylene oxide, gamma irradiation, or autoclaves. The need for sterility is determined by the application, which are many and varied:
- Light microscopy samples
- Cytology sample preparation
- Electron microscopy samples
- Air quality and other environmental monitoring
- Water analysis and water quality testing
- Microbiology colony counting and quality control
- Chemotaxis
- Sterile preparation of buffers, tissue culture media, microbiological media, and other biological fluids
- (1)
- (4)
- (5)
- (1)
- (4)
- (31)
- (122)
- (46)
- (3)
- (24)
- (192)
- (39)
- (10)
- (22)
- (6)
- (87)
- (7)
- (19)
- (50)
- (17)
- (1)
- (6)
- (1)
- (5)
- (2)
- (3)
- (15)
- (23)
- (2)
- (61)
- (5)
- (1)
- (23)
- (11)
- (1)
- (73)
- (8)
- (161)
- (3)
- (3)
- (1)
- (175)
- (1)
- (3)
- (5)
- (59)
- (28)
- (20)
- (93)
- (1)
- (1)
- (45)
- (14)
- (89)
- (4)
- (1)
- (21)
- (1)
- (1)
- (494)
- (116)
- (1)
- (2)
- (1)
- (2)
- (1)
- (326)
- (3)
- (5)
- (2)
- (3)
- (160)
- (313)
- (3)
Filtered Search Results
| Material | MCE |
|---|---|
| For Use With (Application) | For all analytical, ultracleaning, and sterilizing applications at temperatures below 75°C (167°F) – except those involving esters, ether-alcohols, ketones, nitroparaffins or strong acids and bases. |
| Autoclavable | Autoclavable |
MilliporeSigma™ MF-Millipore™ Membrane Filter, 5 μm
MF-Millipore™ Membrane Filter are mixed cellulose esters (MCE) membrane, hydrophilic.
| Pore Size | 5 μm |
|---|---|
| Disposable | Reusable |
| Color | White |
| Material | MCE |
| Sterility | Non-sterile |
| Thickness (Metric) | 135 μm |
| Bubble Point | ≥0.42 bar, air with water |
| Flow Rate | 580 mL/min. x cm2 |
| Wettability | Hydrophilic |
| Type | Filter Membranes |
| Format | Disc |
| Filter Type | Membrane Filter |
| Autoclavable | Not Autoclavable |
| Membrane Type | Plain |
| Gas Flow Rate | 32 L/min./cm2 |
MilliporeSigma™ MF-Millipore™ Membrane Filter, 0.45 μm
MF-Millipore™ Membrane Filter are mixed cellulose esters (MCE) membrane, hydrophilic.
| Thickness (Metric) | 150 μm |
|---|---|
| Pore Size | 0.45 μm |
| Disposable | Reusable |
| Flow Rate | 60 mL/min. x cm2 |
| Wettability | Hydrophilic |
| Type | Filter Membranes |
| Material | MCE |
| Filter Type | Membrane Filter |
| Autoclavable | Not Autoclavable |
| Sterility | Non-sterile |
MilliporeSigma™ Durapore™ Membrane Filters, 0.22 μm
Recommended when maximum recovery is important. Durapore™ PVDF Membranes: 0.22μ Pore Size provide high flow rates and throughput, low extractables, broad chemical compatibility and low protein binding. Available in diameters ranging from 13mm to 142mm.
| Pore Size | 0.22 μm |
|---|---|
| Type | Filter Membranes |
| Color | White |
| Material | PVDF |
| Filter Type | Screen Filter |
| Autoclavable | Not Autoclavable |
| Sterility | Non-sterile |
Cytiva Whatman™ Nylon Membranes
Flexible and durable for easier handling. Cytiva Nylon Membranes are naturally hydrophilic, eliminating need for wetting agents and prewetting when filtering aqueous solutions.
| Material | Nylon |
|---|---|
| Hydrophobicity | Hydrophilic |
| Autoclavable | Autoclavable |
Sartorius Cellulose Nitrate Membrane Filter
Greener Choice
Offers one or more environmental benefits itemized in the U.S. FTC Green Guides.
Learn More
Offers one or more environmental benefits itemized in the U.S. FTC Green Guides.
Learn More
Cellulose nitrate membrane filters with 142 mm diameters are hydrophilic, have high flow rates thanks to their symmetrical structure and are compatible with aqueous solutions, hydrocarbons and several other organic solvents.
| Disposable | Single-use |
|---|---|
| Type | Membrane Filter |
| Format | Disc |
| Diameter (Metric) | 142 mm |
| Quantity | 25/Cs. |
| Material | Cellulose Nitrate |
| Filter Type | Membrane Filter |
| Sterility | Non-sterile |
Sartorius Gridded Sterile Cellulose Nitrate Membrane Filters: 1.2μm
Membrane Filters for Colony Counting, Particle Testing and Microscopy - Cellulose nitrate (cellulose ester), gridded, individually, sterile packaged
MilliporeSigma™ Isopore™ Membrane Filters, 5 μm
Use for analyses of airborne contaminants and other particles using optical or electron microscopy. Isopore™ Polycarbonate Membrane Filters have a smooth, glass-like surface for clearer sample observation. Available in a variety of pore sizes/flow rates, diameters and colors.
| Pore Size | 5 μm |
|---|---|
| Wettability | Hydrophilic |
| Type | Filter Membranes |
| Color | White |
| Material | Polycarbonate |
| Filter Type | Screen Filter |
| Hydrophobicity | Hydrophilic |
| For Use With (Application) | Air Analysis; Cell Biology; Cell Culture; Bioassays; Cytology; Environmental Analysis; Epifluorescence. |
| Autoclavable | Not Autoclavable |
| Sterility | Non-sterile |
| Gas Flow Rate | 50.0 L/min/cm2 |
MilliporeSigma™ MF-Millipore™ Membrane Filter, 0.3 μm
Mixed cellulose esters (MCE) membrane, hydrophilic
| Pore Size | 0.3 μm |
|---|---|
| Flow Rate | 32 mL/min x cm2 |
| Wettability | Hydrophilic |
| Type | Filter Membranes |
| Color | White |
| Material | MCE |
| Hydrophobicity | Hydrophilic |
| Autoclavable | Not Autoclavable |
| Sterility | Non-sterile |
MilliporeSigma™ Mitex™ Membrane Filters, Gridded
Unlaminated for extreme chemical or temperature conditions
| Thickness (Metric) | 125 μm |
|---|---|
| Wettability | Hydrophobic |
| Type | Filter Membranes |
| Color | White |
| Material | PTFE |
| Filter Type | Screen Filter |
| For Use With (Application) | Clarification of acids, bases, and cryogenic fluids; clarification of propellants; analysis of hydraulic fluids; RNA isolation. |
| Autoclavable | Not Autoclavable |
| Sterility | Non-sterile |
| Membrane Type | Gridded |
Sartorius Gridded Sterile Cellulose Nitrate Membrane Filters: 0.8 μm
Gridded Sterile Cellulose Nitrate Membrane Filters for colony counting, particle testing and microscopy. Cellulose nitrate (cellulose ester), gridded, individually, sterile packaged filters.
Sartorius Gridded Nonsterile Cellulose Nitrate Membrane Filters: 0.8μm Pore Size
The non-sterile Membrane Filters are made of cellulose nitrate (cellulose mixed ester), cellulose acetate or regenerated cellulose. They can be used for colony counting, particle testing and microscopy. Choose between gridded or non-gridded, membranes, either with or without hydrophobic edge.
| Pore Size | 0.8 μm |
|---|---|
| Disposable | Single-use |
| Type | Membrane Filter |
| Format | Disc |
| Quantity | 100 Pk. |
| Material | Cellulose Nitrate |
| Filter Type | Membrane Filter |
| For Use With (Application) | For Colony Count, Sterility Testing, Particle Count, Microscopy |
| Sterility | Non-sterile |
MilliporeSigma™ PVC Membrane Filters, 5 μm
For air monitoring applications to analyze silica, carbon black or quartz particulates
MilliporeSigma™ Fluoropore™ Membrane Filter, Pore Size: 5 μm
Unlike fibrous filter media that trap particles in their matrix, Fluoropore™ membranes collect particles on their surface. For use in airborne particle monitoring applications.
| Pore Size | 5.0 μm |
|---|---|
| Flow Rate | 122 mL/min x cm2 |
| Wettability | Hydrophobic |
| Type | Screen Filter |
| Material (Membrane) | Fluoropore |
| Material | PTFE |
| Filter Type | Screen Filter |
| Hydrophobicity | Hydrophobic |
| Autoclavable | Autoclavable |
| Sterility | Non-sterile |
| Pore Size | 0.65 μm |
|---|---|
| Flow Rate | >6 mL/min x cm2 |
| Wettability | Hydrophilic |
| Type | Filter Membranes |
| Color | White |
| Material | PVDF |
| Filter Type | Screen Filter |
| Hydrophobicity | Hydrophilic |
| Autoclavable | Not Autoclavable |
| Sterility | Non-sterile |