Real Time PCR Master Mixes
- (89)
- (4)
- (38)
- (105)
- (35)
- (17)
- (3)
- (14)
- (2)
- (3)
- (9)
- (7)
- (13)
- (163)
- (31)
- (12)
- (50)
- (39)
- (3)
- (10)
- (1)
- (14)
- (2)
- (14)
- (1)
- (4)
- (2)
- (10)
- (4)
- (1)
- (22)
- (10)
- (5)
- (16)
- (13)
- (9)
- (3)
- (202)
- (2)
- (5)
- (40)
- (31)
- (55)
- (101)
- (1)
- (13)
- (7)
- (152)
Résultats de la recherche filtrée
Applied Biosystems™ TaqPath™ ProAmp™ Multiplex Master Mix
TaqPath ProAmp Multiplex Master Mix is for higher multiplexing (up to four targets) in high-throughput genotyping and copy number variation protocols requiring uncompromising reliability and accuracy, even in the presence of inhibitors commonly found in clinical samples.
| Thermostabilité | 72 hr., Assembled Reaction |
|---|---|
| Capacité multiplex | Up to 4-plex |
| Méthode de détection | Primer-probe |
| À utiliser avec (équipement) | QuantStudio 3 or 5, QuantStudio 6/QuantStudio 7 Flex, QuantStudio 12K Flex, QuantStudio Dx, ViiA 7 Real-Time PCR System ViiA 7 Dx, 7500 Fast, StepOne or StepOnePlus |
| Vitesse de réaction | Fast or Standard |
| Type de produit | qPCR Master Mix |
| Colorant de référence passive | Mustang Purple |
| InhibitorToleranceSimple | Very High |
| Méthode PCR | qPCR |
| Conditions d’expédition | Wet Ice |
| À utiliser avec (application) | Genotyping,Pharmacogenomics |
| Contenu et stockage | Store at 2°C to 8°C in the dark. |
| Polymérase | Taq DNA Polymerase |
| Gamme de produits | TaqPath |
| Comprend | dUTP, UNG/UDG |
| Spécificité cible | cDNA or gDNA only |
Applied Biosystems™ TaqMan™ Gene Expression Master Mix
Precise and reliable real-time qPCR quantification over 9 logs of linear dynamic range with Applied Biosystems™ TaqMan™ Gene Expression Master Mix.
| Polymérase | AmpliTaq Gold DNA Polymerase |
|---|---|
| Méthode de détection | Primer-probe |
| À utiliser avec (équipement) | 7000 System, 7300 System, 7500 System, 7900HT System, Applied Biosystems StepOnePlus™ Fast Real-Time PCR SystemStepOne™, Standard Mode, StepOnePlus™, Standard Mode |
| Vitesse de réaction | Standard |
| Colorant de référence passive | ROX (Pre-mixed) |
| Pureté ou qualité | UP (Ultra Pure) |
| Gamme de produits | TaqMan |
| Type d’échantillon | DNA (Genomic), cDNA |
| Méthode PCR | qPCR |
| À utiliser avec (application) | Gene Expression |
Applied Biosystems™ TaqMan™ Fast Virus 1-Step Master Mix for qPCR
TaqMan Fast Virus 1-Step Master Mix is designed for fast, highly sensitive real-time RT-PCR, even in the presence of challenging PCR inhibitors.
| Thermostabilité | Not Applicable |
|---|---|
| Capacité multiplex | Up to 3-plex |
| Méthode de détection | Primer-probe |
| À utiliser avec (équipement) | 7500 Fast System, 7500 System, 7900HT System, QuantStudio 12k Flex, QuantStudio 3, QuantStudio 5, QuantStudio 6 Flex, QuantStudio 6 Pro, QuantStudio 7 Pro, QuantStudio 7 Flex, StepOne, StepOnePlus, ViiA 7 System |
| Vitesse de réaction | Fast or Standard |
| Type de produit | 1-Step Master Mix |
| Colorant de référence passive | ROX (Pre-mixed) |
| Type d’échantillon | Total RNA, Viral DNA, Viral RNA, mRNA |
| InhibitorToleranceSimple | High |
| Méthode PCR | 1-step RT-qPCR |
| Conditions d’expédition | Dry Ice |
| À utiliser avec (application) | Microbial Detection,Gene Expression,DNA Quantification,Presence/Absence |
| Forme | Liquid |
| Polymérase | AmpliTaq Fast DNA Polymerase |
| Format | Tube |
| Hot Start | Built-In Hot Start |
| Gamme de produits | TaqMan |
| Spécificité cible | RNA only, Both RNA and DNA |
| Transcriptase inverse | M-MLV |
Applied Biosystems™ TaqPath™ 1-Step RT-qPCR Master Mix, CG
TaqPath 1-Step RT-qPCR Master Mix, CG, is designed for robust and reproducible one-step pathogen detection and gene expression workflows. The single-tube 4X formulation contains thermostable MMLV reverse transcriptase, dNTPs, UNG, ROX dye, and thermostable Fast DNA polymerase.
| Thermostabilité | Not Applicable |
|---|---|
| Capacité multiplex | Up to 3-plex |
| Méthode de détection | Primer-probe |
| À utiliser avec (équipement) | 7500 Fast System, 7500 System, 7900HT System, QuantStudio™ 12k Flex, QuantStudio™ 3, QuantStudio™ 5, QuantStudio™ 6 Flex, QuantStudio™ 7, StepOne™, StepOnePlus™, ViiA™ 7 System, 7500 Fast Dx System, QuantStudio™ Dx |
| Vitesse de réaction | Fast or Standard |
| Colorant de référence passive | ROX (Pre-mixed) |
| Type d’échantillon | RNA, cDNA, DNA |
| InhibitorToleranceSimple | High |
| Méthode PCR | 1-step RT-qPCR |
| Concentration | 4X |
| À utiliser avec (application) | Microbial Detection,DNA Quantification,Presence/Absence |
| Forme | Liquid |
| Polymérase | Fast DNA Polymerase |
| Hot Start | Built-In Hot Start |
| Gamme de produits | TaqPath |
| Sensibilité | Down to 10 copies |
| Comprend | dUTP, UNG/UDG |
| Spécificité cible | RNA only, Both RNA and DNA |
| Transcriptase inverse | M-MLV |
Applied Biosystems™ TaqMan™ Universal Master Mix II, no UNG
TaqMan Universal Master Mix II is a convenient mix of components (except primers, probes, template, and water) necessary to perform a real-time polymerase chain reaction (PCR).
| GC-Rich PCR Performance | High |
|---|---|
| Méthode de détection | Primer-probe |
| À utiliser avec (équipement) | 7300 System, 7500 System, 7900HT System,Applied Biosystems StepOnePlus™ Fast Real-Time PCR System, StepOne™, Standard Mode, StepOnePlus™, Standard Mode, ViiA™ 7 System |
| Vitesse de réaction | Standard |
| Type de produit | Universal Master Mix II |
| Colorant de référence passive | ROX (Pre-mixed) |
| Pureté ou qualité | UP (Ultra Pure) |
| Type d’échantillon | DNA (Genomic), cDNA |
| Méthode PCR | qPCR |
| Concentration | 2X |
| À utiliser avec (application) | Gene Expression,Genotyping,miRNA analysis |
| Contenu et stockage | Store at 2°C to 8°C in the dark. Guaranteed minimum shelf life is 60 days (exact expiry date printed on product and CofA). |
| Polymérase | AmpliTaq Gold DNA Polymerase |
| Fidélité (par rapport à Taq) | 2 X |
| Gamme de produits | TaqMan |
Applied Biosystems™ TaqMan™ Multiplex Master Mix
Applied Biosystems™ TaqMan™ Multiplex Master Mix is formulated to amplify up to 4 targets in a single reaction, delivering shorter run times (less than 40 minutes).
| Polymérase | AmpliTaq Fast DNA Polymerase |
|---|---|
| GC-Rich PCR Performance | High |
| Méthode de détection | Primer-probe |
| Fidélité (par rapport à Taq) | 2 X |
| Vitesse de réaction | Fast |
| Type de produit | Multiplex Master Mix |
| Gamme de produits | TaqMan |
| Type d’échantillon | DNA |
| Méthode PCR | Multiplex qPCR |
| Concentration | 2X |
| À utiliser avec (application) | Gene Expression,Virus Detection |
Applied Biosystems™ TaqMan™ Universal PCR Master Mix, no AmpErase™ UNG
TaqMan™ Universal PCR Master Mix, No AmpErase™ UNG is the ideal reagent solution when you need a Master Mix for multiple 5' nuclease DNA applications.
| Polymérase | AmpliTaq Gold DNA Polymerase |
|---|---|
| GC-Rich PCR Performance | High |
| Méthode de détection | Primer-probe |
| À utiliser avec (équipement) | 7000 System, 7300 System, 7500 System, 7700 System, 7900HT System,Applied Biosystems StepOnePlus™ Fast Real-Time PCR System, GeneAmp 9600, StepOne™, Standard Mode, StepOnePlus™, Standard Mode |
| Vitesse de réaction | Standard |
| Type de produit | Universal PCR Master Mix |
| Colorant de référence passive | ROX (Pre-mixed) |
| Gamme de produits | TaqMan |
| Type d’échantillon | DNA (Genomic), cDNA |
| Méthode PCR | qPCR |
| Conditions d’expédition | Wet Ice |
| À utiliser avec (application) | Gene Expression,Genotyping,miRNA analysis |
Applied Biosystems™ SYBR™ Green Universal Master Mix
Everything needed for SYBR™ Green dye-based PCR amplification and detection in a convenient, single-tube format.
| Polymérase | AmpliTaq Gold DNA Polymerase |
|---|---|
| GC-Rich PCR Performance | High |
| Méthode de détection | SYBR |
| Vitesse de réaction | Standard |
| Format | Tube |
| Type de produit | Real Time PCR SYBR Master Mix |
| Colorant de référence passive | ROX (Pre-mixed) |
| Gamme de produits | SYBR |
| Méthode PCR | qPCR |
| Concentration | 2X |
| À utiliser avec (application) | Gene Expression |
| Marqueur ou colorant | SYBR Green |
Applied Biosystems™ Path-ID™ qPCR Master Mix
Ambion™ Path-ID™ qPCR Master Mix is a convenient enzyme, buffer, and dNTP mix for TaqMan™ probe-based, real-time PCR detection of DNA targets.
| Polymérase | AmpliTaq Gold DNA Polymerase |
|---|---|
| Méthode de détection | Primer-probe |
| Vitesse de réaction | Fast or Standard |
| Format | Tube |
| Colorant de référence passive | ROX (Pre-mixed) |
| Pureté ou qualité | UP (Ultra Pure) |
| Hot Start | Built-In Hot Start |
| Gamme de produits | Ambion, Path-ID |
| Type d’échantillon | DNA (Genomic), cDNA |
| Méthode PCR | qPCR |
| Conditions d’expédition | Dry Ice |
| À utiliser avec (application) | Animal Health,Pathogen Detection |
| Forme | Liquid |
Applied Biosystems™ Path-ID™ qPCR Master Mix with Manual
Ambion™ Path-ID™ qPCR Master Mix is a convenient enzyme, buffer, and dNTP mix for TaqMan™ probe-based, real-time PCR detection of DNA targets.
| Méthode de détection | Primer-probe |
|---|---|
| Vitesse de réaction | Fast or Standard |
| Type de produit | qPCR Master Mix |
| Colorant de référence passive | ROX (Pre-mixed) |
| Pureté ou qualité | UP (Ultra Pure) |
| Méthode PCR | qPCR |
| Concentration | 2X |
| À utiliser avec (application) | Animal Health,Pathogen Detection |
| Forme | Liquid |
| Contenu et stockage | 2X qPCR Master Mix is stored at –20°C. Nuclease-free water may be stored at any temperature. |
| Polymérase | AmpliTaq Gold DNA Polymerase |
| Format | Tube |
| Hot Start | Built-In Hot Start |
| Gamme de produits | Ambion, Path-ID |
Applied Biosystems™ TaqMan™ Universal Master Mix II, with UNG
TaqMan Universal Master Mix II is a convenient mix of components (except primers, probes, template, and water) necessary to perform a real-time polymerase chain reaction (PCR).
| GC-Rich PCR Performance | High |
|---|---|
| Méthode de détection | Primer-probe |
| À utiliser avec (équipement) | 7300 System, 7500 System, 7900HT System,Applied Biosystems StepOnePlus™ Fast Real-Time PCR System, StepOne™, Standard Mode, StepOnePlus™, Standard Mode, ViiA™ 7 System |
| Vitesse de réaction | Standard |
| Type de produit | Universal Master Mix II |
| Colorant de référence passive | ROX (Pre-mixed) |
| Pureté ou qualité | UP (Ultra Pure) |
| Type d’échantillon | DNA (Genomic), cDNA |
| Méthode PCR | qPCR |
| Concentration | 2X |
| À utiliser avec (application) | Gene Expression,Genotyping,miRNA analysis |
| Contenu et stockage | Store at 2°C to 8°C in the dark. Guaranteed minimum shelf life is 60 days (exact expiry date printed on product and CofA). |
| Polymérase | AmpliTaq Gold DNA Polymerase |
| Fidélité (par rapport à Taq) | 2 X |
| Gamme de produits | TaqMan |
| GC-Rich PCR Performance | High |
|---|---|
| Méthode de détection | SYBR |
| Vitesse de réaction | Fast or Standard |
| Type de produit | Real Time PCR SYBR Master Mix |
| Colorant de référence passive | ROX (Pre-mixed) |
| Pureté ou qualité | UP (Ultra Pure) |
| Type d’échantillon | DNA (Genomic), cDNA |
| Méthode PCR | qPCR |
| Concentration | 2X |
| À utiliser avec (application) | Gene Expression |
| Forme | Liquid |
| Contenu et stockage | The 2x mix contains SYBR™ GreenER™ dye, AmpliTaq™ DNA Polymerase UP, dNTPs with dUTP/dTTP blend, heat-labile UDG, ROX passive reference dye and optimized buffer components. Contains 1 X 1 mL tube, sufficient for 100, 20 μL reactions (10 μL Master Mix per reaction). Store at 2–8°C. Guaranteed minimum shelf life is 60 days (exact expiry date printed on product and CofA). See user guide for primer concentration recommendations for the StepOne and StepOnePlus systems. |
| Polymérase | AmpliTaq DNA Polymerase |
| Format | Vial |
| Suffisant pour | 100 Reactions of 20 μL |
| Hot Start | Built-In Hot Start |
| Gamme de produits | SYBR |
| Marqueur ou colorant | SYBR GreenER |
Invitrogen™ Platinum™ Quantitative PCR SuperMix-UDG
Is a ready-to-use mixture for high-specificity, real-time quantitative DNA amplification, containing UDG to prevent carryover contamination (1,2).
| GC-Rich PCR Performance | High |
|---|---|
| Méthode de détection | Primer-probe |
| À utiliser avec (équipement) | 7500 System, BioRad iCycler iQ, BioRad iQ5, Stratagene Mx4000, MJ Chromo4, MJ Opticon, Stratagene Mx3000P, Stratagene Mx3005P, Cepheid SmartCycler, BioRad MyiQ |
| Vitesse de réaction | Standard |
| Type de produit | Quantitative PCR SuperMix-UDG |
| Gamme de produits | Platinum |
| Type d’échantillon | DNA (Genomic), cDNA |
| Méthode PCR | qPCR |
| Conditions d’expédition | Dry Ice |
| À utiliser avec (application) | Gene Expression |
Thermo Scientific™ Maxima Probe qPCR Master Mix (2X), with separate ROX vial
Optimize qPCR with probe chemistry using standard cycling protocols with these ready-to-use qPCR master mixes.
| Polymérase | Taq DNA Polymerase |
|---|---|
| GC-Rich PCR Performance | High |
| Méthode de détection | Primer-probe |
| À utiliser avec (équipement) | BioRad CFX96™, BioRad iCycler iQ, BioRad iQ5, BioRad MyiQ, MJ Chromo4, Eppendorf MasterCycler RealPlex, Corbett RotorGene, Bio-Rad CFX384 Touch™, Roche LightCycler 480, Cepheid SmartCycler, MJ Opticon |
| Vitesse de réaction | Standard |
| Format | Tube |
| Type de produit | qPCR Master Mix |
| Gamme de produits | Maxima |
| Type d’échantillon | DNA, dsDNA |
| Méthode PCR | qPCR |
| Concentration | 2X |
| À utiliser avec (application) | Gene Expression |
Applied Biosystems™ TaqPath™ 1-Step Multiplex Master Mix (No ROX)
TaqPath 1-Step Multiplex Master Mix (No ROX) is a fast, single-tube, 4X RT-qPCR mix that provides for sensitive, reproducible detection of up to four different RNA/DNA targets in a single multiplex reaction.
| Thermostabilité | Not Applicable |
|---|---|
| Capacité multiplex | Up to 4-plex |
| Méthode de détection | Primer-probe |
| À utiliser avec (équipement) | QuantStudio 6 Pro or QuantStudio 7 Pro, QuantStudio 3 or 5, QuantStudio 6/QuantStudio 7 Flex, QuantStudio 12K Flex, QuantStudio Dx, ViiA 7, 7500, 7500 Fast, 7500 Fast Dx, or use a compatible real-time PCR instrument from another supplier |
| Vitesse de réaction | Fast or Standard |
| Colorant de référence passive | None |
| Type d’échantillon | DNA, RNA |
| InhibitorToleranceSimple | High |
| Méthode PCR | 1-step RT-qPCR |
| Conditions d’expédition | Dry Ice |
| À utiliser avec (application) | Microbial Detection,DNA Quantification,Presence/Absence |
| Format | Tube |
| Gamme de produits | TaqPath |
| Sensibilité | Down to 10 copies |
| Comprend | dUTP, UNG/UDG |
| Spécificité cible | RNA only, Both RNA and DNA |