Please call Customer Service at 1-800-234-7437 or send an email to help@thermofisher.com for assistance.

Experience accurate, specific, and sensitive quantification of endotoxin, proteins, and nucleic acids and measure up to eight samples simultaneously with reproducible results in seconds.

Qubit Flex Endotoxin Detection Starter Kit contents

  • Qubit Flex Fluorometer (Cat. No. Q33327)
  • Qubit Flex Pyrogen Free Assay Tubes Strips, 120 strips (Cat. No. Q32893)
  • Qubit Endotoxin Detection Assay Kit, 80 assays (Cat. No. Q32891)
  • Qubit Flex System Verification Assay Kit (Cat. No. Q33254)
  • WiFi Dongle (Cat. No. A26774)
  • Qubit Flex SmartStart Digital Educational Experience—includes interactive visual demonstrations of how to install, operate, and maintain your instrument

Qubit Flex Fluorometer

The Qubit Flex Fluorometer is designed for highly accurate and sensitive quantification of DNA, RNA, microRNA, protein, and endotoxin. This benchtop fluorometer offers the flexibility to directly measure fluorescence of up to eight samples simultaneously, which reduces assay variability. Paired with Qubit reagents, the Qubit Flex Fluorometer is part of an optimized workflow generating highly accurate and reproducible results. The fluorometer has a large screen and intuitive user interface, making it easy to select and run your desired assay with results displayed in just a few seconds.

Features of the Qubit Flex Fluorometer include:

  • Improved throughput—measure multiple samples and quantify DNA, RNA, protein, and endotoxin up to 50% faster than single-sample readers
  • Flexibility—measure up to eight samples simultaneously using 1–20 μL of sample
  • Complete optimized system—works seamlessly with Qubit reagents to generate reliable, sensitive, and specific results
  • On-board calculators—quickly generates Qubit working solution preparation instructions and determines the molarity of your samples
  • Easy to use—a large 8-inch, state-of-the-art color touchscreen and intuitive user interface results in easy workflow navigation
  • Data export flexibility—data is transferred easily as a CSV or PDF using the included Wi-Fi dongle, a USB drive, or connection to your network drive
  • Several languages available—choices include English, French, Spanish, Italian, German, simplified Chinese, and Japanese
  • Verification test—a pre-loaded program is included to verify performance of the instrument
  • Qubit Flex SmartStart Digital Educational Experience—includes interactive visual demonstrations of how to install, operate, and maintain your instrument

Comprehensive warranty options

The Qubit Flex Fluorometer comes with a standard 1-year warranty that covers repair costs including shipping, parts and labor. Service plans can be bundled with new instrument purchases to provide a 3-year warranty. The Starter Kit is offered with a choice of service plans:

  • Three-year Rapid Exchange (REX) Warranty—replacement shipped out in ~1 business day for labs with critical timelines
  • Three-year AB Repair Center (ABRC) Warranty—instrument repaired and returned in ~3 weeks, ideal for regulated labs required to maintain asset tagging consistency

21 CFR Part 11 Software Module

The Qubit Flex Security Software supports compliance with 21 CFR Part 11 FDA guidelines for security, auditing, and electronic (SAE) signatures using the SAE administration console. The 21 CFR Part 11 software can be purchased separately (Cat. No. Q31994).

Qubit Endotoxin Detection Assay Kit

The Qubit Endotoxin Detection Assay Kit is a sensitive and easy-to-use fluorescent endpoint assay for use on the Qubit Flex Fluorometer that uses amebocyte lysates to quantify endotoxin in protein, peptide, antibody, or nucleic acid samples. Amebocyte lysates are widely used as a simple and sensitive assay for the detection of endotoxin lipopolysaccharide (LPS), the membrane component of gram-negative bacteria.

Features of the Qubit Endotoxin Detection Assay Kit include:

  • Highly sensitive with a broad range—detect as little as 0.01 EU/mL to 10.0 EU/mL
  • Flexible—suitable for wide range of samples, including DNA, RNA, plasmids, antibodies, and more
  • Easy to use—when paired with the Qubit Flex Fluorometer, calculations are performed automatically, helping reduce the potential for error

Specifications

Content And Storage Qubit Flex Endotoxin Detection Starter Kits include:

•Qubit Flex Fluorometer (Cat. No. Q33327)
•Qubit Flex Pyrogen Free Assay Tubes Strips, 120 strips (Cat. No. Q32893)
•Qubit Endotoxin Detection Assay Kit, 80 assays (Cat. No. Q32891)
•Qubit Flex System Verification Assay Kit (Cat. No. Q33254)
•WiFi Dongle (Cat. No. A26774)
•Qubit Flex SmartStart Digital Educational Experience—includes interactive visual demonstrations of how to install, operate, and maintain your instrument
Detection Method Fluorescence
Excitation Wavelength 460 to 480 nm (Blue LED), 620 to 640 nm (Red LED)
For Use With (Equipment) Qubit Flex Fluorometer
Product Line Qubit
Type Benchtop Fluorometer
For Use With (Application) DNA, RNA, Protein and Endotoxin Quantification
Quantity 1 Kit
Warranty Standard Warranty
Does the Qubit Flex NGS Starter Kit (Cat. No. Q45893) include the Qubit Flex System Verification Assay Kit (Cat. No. Q33254)?

No. The Qubit Flex NGS Starter Kit (Cat. No. Q45893) does not include the Qubit Flex System Verification Assay Kit (Cat. No. Q33254). It must be purchased separately.

The description of the Qubit Flex Starter Packages (Cat. Nos. Q32894, Q45893, Q45894) can be found on the Qubit Flex Starter Packages product page.

Does the Qubit Flex Quantitation Starter Kit (Cat. No. Q45894) include a Qubit dsDNA Broad Range Assay Kit (Cat. No. Q33265, Q33266)?

No. The Qubit Flex Quantitation Starter Kit (Cat. No. Q45894) does not include a Qubit dsDNA Broad Range Assay Kit (Cat. No. Q33265, Q33266). It must be purchased separately.

The description of the Qubit Flex Starter Packages (Cat. Nos. Q32894, Q45893, Q45894) can be found on the Qubit Flex Starter Packages product page.

Can I use the Qubit Endotoxin Detection Assay Kit on the Qubit 4 Fluorometer?

No, the Qubit Endotoxin Detection Assay Kit is designed for use with the Qubit Flex Fluorometer and is not currently for use on the Qubit 4 Fluorometer.

To use the Qubit Endotoxin Detection Assay Kit on the Qubit Flex Fluorometer, do I need to perform a software update ?

Yes, the endotoxin detection assay program will be available on Qubit Flex Software version 1.8.0 or later. The latest software is available under the Resources section of www.thermofisher.com/qubit

How do I store the Qubit Endotoxin Detection Assay Kit?

The entire kit can be stored at 2-8 degrees C for 6 months. Reconstituted Endotoxin standard solutions are stable for 4 weeks at 2-8 degrees C and reconstituted dye can be stored for 4 weeks at 2-8 degrees C. Reconstituted amebocyte lysate solution is stable for 1 week at -20 degrees C or colder if frozen immediately after reconstitution.

Is the Qubit Flex Fluorometer (Cat. No. Q33327) compatible with custom assays?

No, the Qubit Flex Fluorometer does not have custom assay capability.

The settings options on my Qubit instrument are greyed out and I am being prompted to sign in. How can I resolve this?

Our Qubit 4 and Qubit Flex instruments will now require users to sign in to access certain menu options (i.e., instrument settings, software update, and system verification). This is necessary to adhere to cybersecurity legal standards that were put in place in 2020. Only when signed in, are all functions of the device are accessible.

Instructions for login:
- Turn on the device
- From the home screen, touch the person icon on the top left corner
- Touch the "Get Started" button
- Touch the "Create Profile" button
- Enter information for username and pin
- Log in by touching the person icon and entering the user info in the sign in fields

Which is the best DNA or RNA quantification instrument?

All of the DNA instruments offered by Thermo Fisher Scientific are of excellent quality. To find the right instrument to quantify DNA or RNA in your lab, explore the detailed comparison of UV-Vis spectrophotometers and fluorometers. Things like sensitivity, throughput and budget may be initial considerations when selecting a DNA quantification instrument. You may also consider whether you need target specificity, sample purity information, RNA quality information, or broad dynamic range.

What is the difference between UV and fluorescence DNA quantification? Which DNA quantification technology should I choose?

UV and fluorescence technologies work differently to quantify DNA. UV quantification relies on the intrinsic absorptivity of DNA and RNA molecules, while fluorescence quantification uses dyes that specifically bind to your molecule of choice. With UV technology, quantification isn't as sensitive, but it has a broader dynamic range and also gives data about sample purity‒plus it is faster because there is no reagent prep. With fluorescence technology you get higher sensitivity and molecule-specific data, but it has lower dynamic range and reagent prep is required. The technology you need will depend on what features are important for your lab and experimentation.

When using the Qubit Flex Fluorometer, do I have to use all 8 samples/wells?

No, the Qubit Flex Fluorometer allows you to select which wells will be used for the experiment. The standards and sample will only be read in the selected wells. If the option to select wells is not available on your Qubit Flex, please update to the current firmware version (download firmware from Technical Resources for Qubit Fluorometers). This feature was introduced in version 1.5.0.