missing translation for 'onlineSavingsMsg'
Learn More
Learn More
Isopropanol (IPA), Optima™ for HPLC, Fisher Chemical™
Description
High purity mobile phase for HPLC and extraction solvent
- Screened for fluorescing and UV-absorbing contaminants to reduce interferences for smoother baselines
- Also meets ACS specifications
- Intended for research use only
Specifications
Specifications
| pH | 7 |
| Melting Point | -89.5°C |
| Absorbance | 0.015 AU max. at 254nm, 0.10 AU max. at 230nm, 0.20 AU max. at 220nm, 1.00 AU max. at 205nm |
| Color | Colorless |
| Density | 0.785g/cm³ |
| Boiling Point | 81°C |
| Quantity | 1 L |
| Identification | Pass Test |
| Packaging | Amber Soda Lime Glass |
| Physical Form | Liquid |
| Show More |
Safety and Handling
| Hazard Statement | DANGER! |
| Precautionary Statement | Emergency Overview Flammable liquid and vapor. Cannot be made non-poisonous. Vapor harmful. Toxic by inhalation, in contact with skin and if swallowed. Irritating to eyes and skin. May cause irritation of respiratory tract. Toxic: danger of very serious irreversible effects through inhalation, in contact with skin and if s. Explosive. Use personal protective equipment. Keep away from open flames, hot surfaces and sources of ignition. Use only under a chemical fume hood. Wash off immediately with plenty of water for at least 15 minutes. Wash off immediately with plenty of water for at least 15 minutes. Immediate medical attention is required. NFPA Health:1 Flammability:3 Instability:0 |
| DOTInformation | DOT Class 3, : Flammable Liquid |