Applied Biosystems™ Triethylamine Acetate (TEAA) 2.0 M
This 2.0 M Triethylamine Acetate solution is used with OPC™ cartridges (Cat. No. 400771), for oligonucleotide purification.
Applied Biosystems™ TaqMan™ QSY and QSY2 Probes
Greener Choice
Offers one or more environmental benefits itemized in the U.S. FTC Green Guides.
Learn More
Offers one or more environmental benefits itemized in the U.S. FTC Green Guides.
Learn More
Applied Biosystems TaqMan QSY and QSY2 probes are dual-labeled probes used for real-time PCR. TaqMan QSY and QSY2 Probes are designed for optimal sensitivity and performance in multiplexed qPCR experiments for detection of up to 6 targets.
| Shipping Condition | Room Temperature |
|---|---|
| Purification Method | HPLC |
| Format | Tube |
| Internal Probe Modification | None |
| Form | Liquid or Dried Down |
| PCR Method | qPCR |
| Product Line | TaqMan |
| Detection Method | Primer-probe |
Applied Biosystems™ MagMAX™ Pure Bind Beads
Greener Choice
Offers one or more environmental benefits itemized in the U.S. FTC Green Guides.
Learn More
Offers one or more environmental benefits itemized in the U.S. FTC Green Guides.
Learn More
MagMAX Pure Bind Beads are ready-to-use magnetic beads that provide optimized size selection and PCR cleanup, removing small fragments such as dNTPs, salts, primers, and primer-dimers.
| GC-Rich PCR Performance | High |
|---|---|
| Form | Beads in Suspension |
| For Use With (Application) | NGS Cleanup, PCR Cleanup, PCR Purification, DNA Purification, Sequencing |
| Test Time | 20 min. |
Applied Biosystems™ TaqMan™ Exogenous Internal Positive Control Reagents
Greener Choice
Offers one or more environmental benefits itemized in the U.S. FTC Green Guides.
Learn More
Offers one or more environmental benefits itemized in the U.S. FTC Green Guides.
Learn More
TaqMan™ Exogenous Internal Positive Control Reagents contain a pre-optimized internal positive control (IPC) with pre-designed primers and TaqMan™ probe.
| GC-Rich PCR Performance | Low |
|---|---|
| Format | Tube(s) |
| Internal Probe Modification | TAMRA™ Quencher (3'), VIC™ (5') |
| Product Type | Exogenous Internal Positive Control Reagent |
| Reaction Speed | Standard |
| PCR Method | qPCR |
| Product Line | TaqMan |
Applied Biosystems™ TaqMan™ Array Human NFKB Pathway
Easy to use - Since the primer/probe is supplied in a dry state, Just add the master mix and sample.
Applied Biosystems™ Retainer & Base Set (Fast) for 3500/3500xL Genetic Analyzers, 96 well
This 96-well plate Retainer and Base Set is for use with Fast (0.1mL) 96-well samples pates on the 3500 series Genetic Analyzers.
Applied Biosystems™ Sequencing Chemistry Installation Kit for 3500xL Series Genetic Analyzer
The 3500 platform can run a wide variety of applications
Applied Biosystems™ MagMAX™ DNA Multi-Sample Ultra Kit (with extra proteinase K and DNA binding beads)
The MagMAX™ DNA Multi-Sample Ultra Kit is optimized to isolate genomic DNA (gDNA) from a variety of samples, such as whole blood, buccal cells, saliva, urine, blood cards, mouth rinse, and tissue.
| Target | Genomic DNA |
|---|---|
| Format | Kit |
| Product Type | DNA Multi-Sample Ultra Kit |
| Sample Type | Blood,Buccal Samples,Cells,Liquid Samples (e.g. Serum),Tissue |
| High-throughput Compatibility | High-throughput Compatible, Manual Protocols, Automated Protocols |
| For Use With (Application) | Next-Generation Sequencing, Real-Time Quantitative PCR (qPCR) |
| Product Line | MagMAX |
Applied Biosystems™ ProFlex™ PCR System, 2 x 96-well
The ProFlex 2 x 96-well PCR system is the latest in our line of Applied Biosystems thermal cyclers. The ProFlex system combines the reliability and performance you've come to expect from Applied Biosystems instruments with the flexible configuration and control features that adapt to your research needs.
| Programs | Auto re-start (after Power Outages), Program Overwrite Protection |
|---|---|
| Thermal Uniformity | <0.5°C (20 sec. after reaching 95°C) |
| Block Configurations | 2 x 96-well Isothermal Blocks |
| Memory | USB and On-board |
| User Interface | USB, WiFi, Cloud, Ethernet |
| Dimensions | 22 x 13 x 10.6 in. (56.5 x 33 x 27 cm) |
| Block Format | Interchangeable |
| Max. Ramp Rate | 3°C/sec. (Block), 1.6°C/sec. (Sample) |
| For Use With (Application) | PCR |
| High-throughput Compatibility | High-throughput Compatible |
| Thermal Range | 0°C to 100°C |
| Display Type | 8.4 in. Color TFT LCD Touchscreen |
| Product Type | Thermal Cycler |
| Capacity | 2 x 96-well, 0.2 mL Tubes |
| Reaction Speed | Fast, Standard |
| Voltage | 100/240 V |
| Thermal Accuracy | ±0.25°C (35°C to 99.9°C) |
Applied Biosystems™ ProFlex™ PCR System, 96-well
The ProFlex 96-well PCR system is the latest in our line of Applied Biosystems thermal cyclers. The ProFlex system combines the reliability and performance you've come to expect from Applied Biosystems instruments with the flexible configuration and control features that adapt to your research needs.
| Programs | Auto re-start (after Power Outages), Program Overwrite Protection |
|---|---|
| Thermal Uniformity | <0.5°C (20 sec. after reaching 95°C) |
| Block Configurations | 96-well, 6-Zone VeriFlex Block |
| Memory | USB and On-board |
| User Interface | USB, WiFi, Cloud, Ethernet |
| Dimensions | 22 x 13 x 10.6 in. (56.5 x 33 x 27 cm) |
| Block Format | Interchangeable |
| Max. Ramp Rate | 6°C/sec. (Block), 4.4°C/sec. (Sample) |
| For Use With (Application) | PCR |
| High-throughput Compatibility | High-throughput Compatible |
| Weight | 41 lb. (18.8 kg) |
| Thermal Range | 0°C to 100°C |
| Display Type | 8.4 in. Color TFT LCD Touchscreen |
| Product Type | Thermal Cycler |
| Reaction Speed | Fast, Standard |
| Voltage | 100/240 V |
| Thermal Accuracy | ±0.25°C (35°C to 99.9°C) |
Applied Biosystems™ PowerUp™ SYBR™ Green Master Mix for qPCR
Pre-formulated, optimized, universal 2X master mix for real-time PCR workflows.
| Shipping Condition | Wet Ice |
|---|---|
| InhibitorToleranceSimple | Medium |
| Concentration | 2X |
| For Use With (Application) | Gene Expression |
| PCR Method | qPCR |
| Multiplex Capability | Single-plex |
| Detection Method | SYBR |
| Includes | dUTP, UNG/UDG |
| Thermostability | 72 hr., Assembled Reaction |
| Polymerase | Dual-Lock Taq DNA Polymerase |
| Format | Tube |
| Product Type | Real Time PCR SYBR Master Mix |
| Passive Reference Dye | ROX (Pre-mixed) |
| For Use With (Equipment) | 7500 Fast System, 7500 System, 7900HT System, QuantStudio 12k Flex, QuantStudio 3, QuantStudio 5, QuantStudio 6 Flex, QuantStudio 6 Pro, QuantStudio 7 Pro, QuantStudio 7 Flex, StepOne, StepOnePlus, ViiA 7 System |
| Sample Type | DNA |
| Reaction Speed | Fast or Standard |
| Target Specificity | cDNA or gDNA only |
| Product Line | PowerUP, SYBR |
Applied Biosystems™ ProFlex™ PCR System, 2 x 384-well
ProFlex™ PCR Systems are the latest in our line of Applied Biosystems™ thermal cyclers, providing the reliability and performance you've come to expect from Applied Biosystems instruments.
| Programs | Auto re-start (after Power Outages), Program Overwrite Protection |
|---|---|
| Thermal Uniformity | <0.5°C (20 sec. after reaching 95°C) |
| Block Configurations | 2 x 384-well Isothermal Blocks |
| Memory | USB and On-board |
| User Interface | USB, WiFi, Cloud, Ethernet |
| Dimensions | 22 x 13 x 10.6 in. (56.5 x 33 x 27 cm) |
| Max. Ramp Rate | 3°C/sec. (Block), 1.6°C/sec. (Sample) |
| For Use With (Application) | PCR |
| High-throughput Compatibility | High-throughput Compatible |
| Weight | 45 lb. (20.4 kg) |
| Thermal Range | 0°C to 100°C |
| Display Type | 8.4 in. Color TFT LCD Touchscreen |
| Product Type | Thermal Cycler |
| Capacity | 768 x 20 μL Tubes, 2 x 384-well Plate |
| Reaction Speed | Fast, Standard |
| Voltage | 100/240 V |
| Thermal Accuracy | ±0.25°C (35°C to 99.9°C) |
| Product Line | ProFlex |